BC200/BC201 Regenerative Drive Adjustable Speed DC Control

Similar documents
BC203 Regenerative Drive Adjustable Speed DC Control

BC138 BC139 DC CONTROL

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE FULL WAVE 4 QUADRANT REV S/LT NLT R33 AC LINE FUSE ARMATURE F2 FUSE TB2

for Catalog BC354 6/15 Installation & Operating Manual MN731

BC160 NEMA 4X / IP65 Adjustable Speed DC Control

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL


BC141, BC142, BC142-5 & BC142-6 DC Control

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

KBPC-240D (Part Nos and 9342) Installation and Operation Manual Supplement

INSTALLATION AND OPERATION MANUAL SUPPLEMENT KBPC-225 (PART NOS & 9392)

17429X.00 SERIES MODELS:

Boston Gear Ratiotrol DC Motor Speed Control

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Installation and Operation Manual. *See page 6 for CE Information

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

Installation & Operation Manual

CONTROL FEATURES AVAILABLE OPTIONS

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

Boston Gear Ratiotrol DC Motor Speed Control

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

Boston Gear Ratiotrol

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

Boston Gear Ratiotrol DC Motor Speed Control

KBMD-240D MULTI-DRIVE

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

CABINET REEL OPERATING INSTRUCTIONS

An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

CABINET REEL OPERATING INSTRUCTIONS

Copyright 2013 Automationdirect.com Incorporated All Rights Reserved

Installation and Operating Manual

Boston Gear Ratiotrol

Series 2330MKII. Single-Phase. Adjustable-Speed. DC Motor Controllers (1/6 3 HP) BOOK 0958-B

KBVF Adjustable Frequency Drive

BALDOR ELECTRIC COMPANY PRODUCT OVERVIEW

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455

DORNER Conveyor Speed Control

MM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

KBIC SCR DC Motor Speed Controls

MaxPak Plus Analog DC V S Drive

SAFTRONICS DF8 PLUS SERIES

TABLE OF CONTENTS STANDARD FEATURES

SERIES 2600/2610 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-5 HP)

Installation and Operation Manual

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Fincor Series 2230 MKII/2240

PALLET MASTER (PMD) OPERATING INSTRUCTIONS

Series 5 Inverter NEMA 4X, IP-65 Installation and Operating Manual

WarninG TraDeMarkS Copyright 2013, 2018 Automationdirect.com Incorporated All Rights Reserved

KBAC SERIES Adjustable Frequency Drives for 3-Phase AC Motors NEMA-4X / IP-65

Installation & Operation Manual DA SERIES

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

USER S MANUAL VFD05-D230-PCM VFDP4X04-D230-PCM VFDA4X04-D230-PCM VFDF4X04-D230-PCM VFDS4X05-D230-PCM

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

STRAIGHTENER OPERATING INSTRUCTIONS

STRAIGHTENER OPERATING INSTRUCTIONS

TABLE OF CONTENTS WARRANTY. 1 INTRODUCTION. 2 CONTROL FEATURES. 2 HEATSINK DIMENSIONS. 2 SPEEDPOT KIT ASSEMBLY. 3 MOUNTING PROCEDURE.

Straightener operating instructions

*** A Complete Line of Motor Drives

Boston Gear. Adjustable-Speed Regenerative DC Motor Controllers. Installation and Operation Manual. Doc. No RBA-RG VEA-RG Series

DC Variable Speed Drive Panel

Filtered PWM Speed Control for Permanent Magnet DC Motors

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

Boston Gear Ratiotrol

5001TCP SPEED CONTROLLER

SCR THYRISTOR MOTOR CONTROLS , , , , , , M , M , M OPERATION MANUAL

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

PowerOhm Installation Manual for LG ATV Series Braking Modules

2013 Migration Patterns traffic flow by state/province

USER S MANUAL. Variable-frequency drive for 3-phase and single-phase AC motors

USER S MANUAL

An American Control Electronics Brand. RG6xU SERIES USER MANUAL RG60U RG61U.

2016 Migration Patterns traffic flow by state/province

DC Drive Selection Guide

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

INSTALLATION AND OPERATION MANUAL KBAC SERIES. Adjustable Frequency Drive for 3-Phase AC Motors NEMA 4X / IP65

730 CONTROL SERIES. Instruction Manual CONTROLS. Low Voltage DC Brushless Control. Phone (317) Fax (317)

XP Series USER MANUAL PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC XP02-115AC XP02-115AC-Q XP05-115AC XP10-115AC.

PowerOhm Installation Manual for BM R Series Braking Modules

MM23xx1C Series USER MANUAL MM23001C MM23001C-Q MM23011C MM23011C-Q MM23101C MM23111C MM23201C MM23211C MM23401C MM23411C.

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

DC3N Non-Regenerative DC Drives

RG500 SERIES USER S MANUAL. SCR, Dual Voltage, Adjustable-Speed Regenerative Drives for DC Brush Motors

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

Boston Gear Ratiotrol

MHS Series USER MANUAL MHS MHS MHS MHS443-10

Transcription:

BC200/BC201 Regenerative Drive Adjustable Speed DC Control 6/15 Installation & Operating Manual MN716

Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download the latest version of this manual in Adobe Acrobat PDF format.

Table of Contents Chapter 1 Introduction Introduction... 1-1 Safety Notice... 1-1 Receiving... 1-2 Chapter 2 Installation Mounting...1 Electrical Connections...3 AC LINE...3 Ground Connection...3 Motor Armature Connection...3 Motor Field Connection (Shunt Wound Motors Only)...4 Full Voltage Field Connection (Shunt Wound Motors Only)...4 Half Voltage Field Connection (Shunt Wound Motors Only)...4 Main Speed Potentiometer Connection...5 Voltage Following...5 Enable...6 Start/Stop Circuit...6 OUTPUT RELAY...6 DC Tachometer Input...7 Startup and Adjustments...7 Motor Type...7 Torque Requirements...7 Set Jumpers...7 J3 - Motor Armature Voltage... 8 J4 Tachometer Voltage... 8 J5 - FEEDBACK TYPE...8 J6 - Current Limit Mode...9 J7 - Speed or Torque Control...9 J8 - Speed Linear Torque (S/L) and Non Linear Torque (NLT)...9 Startup...9 Trimpot Adjustments...10 Forward Acceleration (FWD ACCEL)...10 Reverse Acceleration (REV ACCEL)... 10 Offset...10 Deadband (DB)...10 Forward Current Limit (FWD CL) and Reverse Current Limit (REV CL)...11 IR Compensation (IR Comp)................................................... 11 Maximum Speed (MAX)...12 Response (RESP)...12 Timed Current Limit (TCL) Trimpot...12 Operation...12 Troubleshooting...14 MN716 i

ii MN716

Chapter 1 Introduction Introduction Thank you for purchasing the BC200/BC201 chassis style DC drive. Baldor is committed to providing total customer satisfaction by producing quality products that are easy to install and operate. The BC200/BC201 is manufactured with Surface Mount components (SMT), incorporating advanced circuitry and technology. The BC200/BC201 is a full-wave regenerative drive capable of operating DC PM or Shunt motors in a bidirectional mode. Its 4-quadrant operation provides forward and reverse torque in both directions. This allows the control to maintain constant speed with overhauling loads and provides rapid instant reversing and controlled braking. Because of its excellent controllability and response time, the BC200/BC201 can replace servos in many applications. The control is factory set for armature feedback, which can provide 1% load regulation over a motor base speed of 50:1. However, tachometer feedback is also available if superior regulation is required. By resetting mode jumper J7 to the TRQ position, the BC200/BC201 can be changed from a speed control to a torque control. The BC200/BC201 can be operated with either a two (2) or three (3) wire start/stop circuit, or can be started from the AC line. A set of dedicated relay contacts are provided which are activated via the start/stop circuit. They can be used to turn on or off corresponding equipment or to sound an alarm if the drive stops. SAFETY NOTICE A Warning statement indicates a potentially hazardous situation which, if not avoided, could result in injury or death. A Caution statement indicates a potentially hazardous situation which, if not avoided, could result in damage to property. A Note indicates additional information that is not critical to the installation or operation. WARNING: This equipment may contain voltages as high as 1000 volts! Electrical shock can cause serious or fatal injury. Only qualified personnel should attempt the start-up procedure or troubleshoot this equipment. WARNING: Be sure the system is properly grounded before applying power. Do not apply AC power before you ensure that all grounding instructions have been followed. Electrical shock can cause serious or fatal injury. WARNING: Electrical shock can cause serious or fatal injury. Be sure that all power is disconnected and there is no voltage present from this equipment or equipment to which it is or will be connected. Electrical shock can cause serious or fatal injury. Only qualified personnel should attempt the installation and start-up procedures. WARNING: Electrical shock can cause serious or fatal injury. Verify there is no voltage phase-to-phase or phaseto-neutral at the motor leads before connecting motor to this control. Motor may have high voltage present even when disconnected from this control. WARNING: Do not use motor overload relays with an automatic reset feature. These are dangerous since the process may injure someone if a sudden or unexpected automatic restart occurs. If manual reset relays are not available, disable the automatic restart feature using external control wiring. WARNING: This unit has an automatic restart feature that will start the motor whenever input power is applied and a RUN (FWD or REV) command is issued. If an automatic restart of the motor could cause injury to personnel, the automatic restart feature should be disabled. WARNING: Using a jumper to eliminate the start/stop function will cause the motor to run at the Main Speed Potentiometer setting when the AC line is applied. WARNING: If possible, do not adjust trim pots with the main power applied. Electrical shock can cause serious or fatal injury. If adjustments are made with the main power applied, an insulated adjustment tool must be used to prevent shock hazard and safety glasses must be worn. WARNING: Do not use this drive in an explosive environment. An explosion can cause serious or fatal injury. This drive is not explosion proof. WARNING: When the Enable jumper is installed, the drive and motor will start and run when AC power is applied, when power is restored after a momentary power loss, or after an overload or TCL fault is reset. The user must ensure that automatic start up of the driven equipment will not cause injury to operating personnel or damage to the driven equipment. The user is responsible for providing suitable audible or visual alarms or other devices to indicate that the drive may start at any moment. Failure to observe this warning could result in severe bodily injury or loss of life. WARNING: Do not use start/stop, inhibit or enable functions as a safety disconnect. Use only an AC line disconnect for that purpose. Failure to observe this warning could result in severe bodily injury or loss of life. MN716 1-1

SAFETY NOTICE Continued Caution: Disconnect motor leads (A1 and A2) from control before you perform a Dielectric Withstand test on the motor. Failure to disconnect motor from the control will result in extensive damage to the control. The control is tested at the factory for high voltage / leakage resistance as part of Underwriter Laboratory requirements. Caution: Do not connect AC power to the Motor terminals A1 and A2. Connecting AC power to these terminals may damage the control. Caution: Baldor recommends not to use Grounded Leg Delta transformer power leads that may create ground loops. Instead, we recommend using a four wire Wye. Caution: Suitable for use on a circuit capable of delivering not more than 5,000 RMS symmetrical short circuit amperes listed here at rated voltage. Caution: Adjusting the current limit above 150% of the motor nameplate rating can cause overheating and demagnetization of the PM motor. Caution: Do not leave the motor in a locked rotor condition for more than a few seconds since motor damage may occur. Caution: Shunt wound motors may be damaged if field windings remain energized for an extended period of time without armature rotation. Receiving Each control is thoroughly tested at the factory and carefully packaged for shipment. When you receive your control, there are several things you should do immediately. 1. Observe the condition of the shipping container and report any damage immediately to the commercial carrier that delivered your control. 2. Verify that the part number you received is the same as the part number listed on your purchase order. 3. Do not unpack until ready for use. Table 1-1 Electrical Ratings Model Number BC200 BC201 Input Volts (VAC) Max. Line Current (Amps RMS) Armature (VDC) Max. Current (ADC) Max. Field Current @ 200/100 VDC Max Power HP, (kw) 115 16-90 to +90 11 3 1, (.75) 230 16-180 to +180 11 3 2, (1.5) 115 24-90 to +90 16 3 1-1/2, (1) 230 24-180 to +180 16 3 3, (2) Table 1-2 Performance Specifications Parameter Specification Factory Setting AC Line Input Voltage (VAC ±10%, Single Phase, 50/60Hz) 115 or 230 230 Arm Voltage Range at 115VAC Line (VDC) -90 to +90 - Arm Voltage Range at 230VAC Line (VDC) -180 to +180 180 Field Voltage at 115VAC Line (VDC) 100/50 - Field Voltage at 230VAC Line (VDC) 200/100 - Service Factor 1.0 - Duty Continuous - Max Load Capacity (% for 2 minutes) 150 - Ambient Temperature Range ( C) 0-50* - Speed Range (Ratio) 50:1 - Arm Feedback Load Regulation (% Base Speed) ±1 - Tach Feedback Load Regulation (% Set Speed) ±1 - Current Ranges (ADC) 2.5, 5.0, 7.5, 10, 15** 15 or 10 FWD and REV Accel Range (Secs.) 0.1-15 1 Dead Band Range (% Base Speed) -3 to +3 0 Max Speed Trimpot Range (% Base Speed) 70-110 100 IR Comp Range at 115VAC Line (VDC) 0-15 5 IR Comp Range at 230VAC Line (VDC) 0-30 10 FWD and REV CL Range (% Range Setting) 0-150 150 Timed CL Range (Sec.) 1-15 5 Voltage Following Input Range (VDC) *** -10 to +10-10 to +10 Voltage Following Linearity (% Base Speed) ±0.5 - Tachometer Voltage Input (Volts/1000 RPM) 7, 20/30, 50 50 1-2 MN716

F1 Chapter 2 Installation WARNING: Do not use this drive in an explosive environment. An explosion can cause serious or fatal injury. This drive is not explosion proof. Mounting Mount the BC200/BC201 in a vertical position (connection terminals in down or up position) on a flat surface free of moisture, metal chips, or corrosive atmosphere. Mount the control in such a manner that there is unrestricted air flow through the heatsink cooling fins. Note: If drive is mounted in other than a vertical position, decrease maximum allowable ambient temperature by 10 C. A 5K ohm Remote Speed potentiometer is provided with each control. Install potentiometer using hardware provided. Be sure to install insulating disk between potentiometer and inside of front panel. Enclosure - When mounting the BC200 or BC201 in an enclosure, it must be large enough to allow for proper heat dissipation. A 12x12x24 enclosure is suitable for the BC200 at full rating and a 12x24x36 enclosure is suitable for the BC201 at full rating. Smaller enclosures may be used if full rating is not required or if adequate ventilation, or auxiliary cooling methods are used. Figure 2-1A Mounting Hole Locations 10.00 [254.00] 8.00 [203.20] FWD ACC REV ACC DB OFFSET RG LOGIC (SMT) T1 CON3 MAX SPD RESP IR COMP REV CL FWD CL TCL RO.089 [R2.3] (4 PL.) 0.324 [8.2] (4 PL) RO.172 [R4.4] (4 PL) K1 1 2 3 4 5 6 7 8 9 10 11 12 13 CON1 CON2 L2 L1 A2 A1 COM +20V B4 B3 B2 B1 F1 F2 L1 L2 M1 M2 7.10 7.70 [180.34] [195.58] 0.30 [7.62] 0.60 [14.7] 3.440 [87.4] Note: CONTROL SHOWN ABOVE IS MODEL BC201. HEIGHT OF MODEL BC200 IS 2.57" (65mm). MN716 2-1

F1 J3 J6 J8 Figure 2-1B Control Board Component Location FWD ACC REV ACC DB OFFSET MAX SPD RESP IR COMP REV CL FWD CL TCL CON3 FWD ACC REV ACC DB OFFSET MAX SPD RESP IR COMP REV CL FWD CL TCL CON3 RG LOGIC (SMT) F1 K1 FWD EN REV EN FWD ENABLE (LED) REV J2 ENABLE (LED) POWER ON (LED) J7 POWER ON T1 J1A J1B K1 J7 T1 J1A, J1B J4 CL CL LED J5 J2 J5 J6 J8 J4 J3 1 2 3 4 5 6 7 8 9 10 11 12 13 CON1 L2 L1 A2 A1 COM CON2 +20V B4 B3 B2 B1 F1 F2 L1 L2 M1 M2 GROUND SCREW F1 TB2 F2 (F+ F-) (L1 L2 M1 M2) 2-2 MN716

Electrical Connections To avoid erratic operation, do not bundle the AC line and motor wires with signal or control wiring. Do not bundle motor wires from multiple controls in the same conduit. Use shielded cables on all signal wiring over 12 (30 cm). The shield should be earth grounded on the control side only. Wire the control in accordance with the National Electrical Code requirements and other local codes that may apply. AC LINE Verify the AC line voltage matches the line voltage of the control. Connections are shown in Figure 2-2. The BC200/BC201 has a single AC line fuse connected in series with terminal L1. Fuse (F1) is 25A for BC201 and 20A for BC200). Be sure to fuse each conductor which is not at ground potential (do not fuse neutral or grounded conductors). A separate AC line switch or contactor must be connected as a disconnect switch so that contacts open each ungrounded conductor. See Table 2-1. Table 2-1 Terminal Block Wiring Information Terminal Block Designation Connection Designation Minimum Supply Wire Gauge (AWG - Copper) Maximum Maximum Tightening Torque (lbs- in) (Power Board) F+, F- 22 14 3.5 TB2 (Power Board) L1, L2, M1, M2, GND 18 10 3.5 (Logic Board) Logic Connections 22 14 3.5 Figure 2-2 Power Connections F1 AC LINE FUSE TB2 F+ F- L1 L2 M1 M2 FIELD AC LINE INPUT + - A ARMATURE Ground Connection Connect all ground wires (earth) to the green ground screw that is provided on the inside of the control to the right side of (not shown), tighten to correct torque, Table 2-1. Motor Armature Connection Connect the motor armature positive lead (+) to Terminal M1 and negative lead (-) to Terminal M2, as shown in Figure 2-2. An armature fuse (F2) is also provided with a rating equal to the maximum RMS rating of the control. It is recommended that the correct size armature fuse be installed, depending on the rating of the motor and form factor (RMS/AVG current). Fuse type should be Littlefuse 326 ceramic or Buss ABC, or equivalent. A fuse chart is presented in Table 2-2, which suggests appropriate armature fuse ratings. However, the specific application may require larger fuse ratings based on ambient temperature, CL set point and duty cycle of operation. MN716 2-3

Table 2-2 Armature Fuse Chart (F2 Power Board) Motor Horsepower Approximate DC Motor Fuse Rating 90VDC 180VDC Current Amps (AC Amps) 1/8 1/4 1.3 2 1/6 1/3 1.7 2-1/2 1/4 1/2 2.5 4 1/3 3/4 3.3 5 1/2 1 5.0 8 3/4 1-1/2 7.5 12 1 2 10.0 15, 20 * 1-1/2 3 15.0 25 The Logic Control board contains a low amperage fuse F1 (.150 amp Littlefuse 3AG, normal blow or equivalent), which protects the control transformer and other components against catastrophic failure, Figure 2-1. Under normal circumstances, this fuse should never blow. If the fuse should blow, refer to Troubleshooting Guide. Motor Field Connection (Shunt Wound Motors Only) Full Voltage Field Connection (Shunt Wound Motors Only) Do not use F+ and F- terminals for any other motor type. Connect the motor field leads to F1 (+) and F2 (-) terminals of TB2 as shown in Figure 2-2 and Table 2-3. CAUTION! Do not connect motor armature leads to Terminals F+ and F-. Do not use Terminals F+ and F- for any purpose other than to power the field of a shunt wound motor. Shunt wound motors may be damaged if the field remains energized without armature rotation for an extended period of time. Table 2-3 Field Connections (Shunt Wound Motors Only) AC Line Voltage (VAC) Armature Voltage (VDC) Field Voltage (VDC) Field Connections 115 90 100 F+ and F- 115 90 50 F+ and L1 230 180 200 F+ and F- 230 180 100 F+ and L1 230 90* 100 F+ and L1 Half Voltage Field Connection (Shunt Wound Motors Only) Do not use F+ and F- terminals for any other motor type. Connect the motor field leads to F1 (+) and L1 (-) terminals of TB2, as shown in Figure 2-3 and Table 2-3. Figure 2-3 Half Voltage Field Connection F1 AC LINE FUSE TB2 F+ F- L1 L2 M1 M2 + A - FIELD AC LINE INPUT ARMATURE 2-4 MN716

Main Speed Potentiometer Connection The main speed potentiometer can be connected in several ways using terminals 10, 11, 12, 13. (A 5K ohm potentiometer is supplied with control. A 10K potentiometer can also be used.) Caution: Terminals 10, 11, 12 and 13 are not isolated from AC line. Do not ground (earth). A. Unidirectional operation only - Connect potentiometer to terminals 10, 12, 13 for forward direction. Connect to terminals 11, 12, 13. for reverse direction. See Figures 2-4A and 2-4B. B. Bidirectional operation using user supplied, SPDT, FWD/REV Switch - Connect potentiometer and switch to terminals 10, 11, 12, 13. See Figure 2-4C. C. Bidirectional operation with potentiometer - Connect potentiometer to terminals 10, 11, 12. See Figure 2-4D. Figure 2-4 Main Speed Potentiometer Connections Figure 2-4A Forward Figure 2-4B Reverse 10 11 12 13 11 12 13 Main Speed Pot Figure 2-4C BiDirectional with Reversing Contact Main Speed Pot Figure 2-4D BiDirectional with Speed Pot 10 11 12 13 FWD REV Main Speed Pot Main Speed Pot 10 11 12 13 Voltage Following An isolated analog voltage can be used in lieu of main speed potentiometer. Connect signal to terminals 12 and 13. See Figure 4-5. Figure 2-5 Voltage Following 12 13 ~ ± ISOLATED VOLTAGE SOURCE Note: Terminal 13 is common. A positive signal with respect to terminal 13 will produce a positive output to motor. A negative signal with respect to terminal 13 will produce a negative output. A 0 to ±10 VDC is required to operate control from 0 to ± full output. If required, use the (Optional) BC212, Signal Isolator. MN716 2-5

Enable Warning: When the Enable jumper is installed, the drive and motor will start and run when AC power is applied, when power is restored after a momentary power loss, or after an overload or TCL fault is reset. The user must ensure that automatic start up of the driven equipment will not cause injury to operating personnel or damage to the driven equipment. The user is responsible for providing suitable audible or visual alarms or other devices to indicate that the drive may start at any moment. Failure to observe this warning could result in severe bodily injury or loss of life. Control may be started and stopped with the Enable circuit. To use this feature, install a jumper across, terminals 5 and 7, (Start/Stop circuit), and connect Enable contacts to, terminals 8 and 9. When the contacts close the control is in the Enable state and the motor will start and run. When the Enable contacts open, the control is in the Inhibit state and the motor will coast to rest. See Figure 2-6A. Note: If Enable is not used, install a jumper between terminals 8 and 9 or control will not operate. Start/Stop Circuit A standard 3-wire start/stop push button control station may be connected to terminals 5, 6, and 7, allowing remote start/stop control. If AC input power is cycled On/Off, or if the timed current limit mode has timed out, the start push button must be used to restart the motor. See Figure 2-6B. Note: The Start/Stop function may be bypassed by connecting a jumper wire across the Start and Com terminals of. Note: The Timed CL function will operate only when the Start/Stop mode is used. Note: The Control will not start if the input AC line voltage is below 20% of nominal, (190 VAC on 230 VAC input). OUTPUT RELAY S.P.S.T. relay contacts (terminals 3 and 4) are used to signal a warning or to shut other equipment down if control goes to an Inhibit state. Rating of contacts are 1A-28VDC, 0.5A-115VAC. See Table 4-4 for relay control state vs. contact state. See Figure 4-6C. Figure 2-6 Enable, Start/Stop and Relay Circuit Wiring Figure 4-6A - Enable Figure 4-6B - Start/Stop Circuits Figure FIGURE 4-6C C - RELAY CONTACTS Relay Contacts 8 9 CLOSE TO RUN OPEN TO COAST STOP COAST TO STOP (NORMALLY CLOSED) 5 6 7 START (NORMALLY OPEN) 3 4 RELAY CONTACTS Table 2-4 Control State vs. Relay Contact State Description of Control State Relay Contact State Using Start / Stop Start / Stop Bypassed Power Off O O Power Applied O X Control in Stop Mode O N/A Control is started with Start button X N/A Control has Timed Out in TCL O N/A O = Open, X = Closed, NA = Not Applicable 2-6 MN716

DC Tachometer Input If Tachometer Feedback is used, Jumper J5 must be in the TFB position and an analog tach signal must be connected to, terminals 1 and 2. The IR COMP Trimpot must be set to minimum, fully CCW. Connect the tachometer so that when the motor rotates in the desired forward direction the positive tach voltage lead is connected to terminal 1 and the negative lead to terminal 2. See Figure 2-7. Figure 2-7 Tachometer Connection 1 2 G + - Note: If the Tachometer leads are connected backwards, the motor will run at full speed and will not respond to a speed reference signal. Verify position of Jumper J5 is in TFB and the tach signal polarity is correct. Startup and Adjustments Motor Type The BC200/BC201 is a full wave regenerative, bi-directional control used to operate Permanent Magnet, (PM), and Shunt Wound DC motors. Do not use the control in applications where specified ratings would be exceeded. Torque Requirements When replacing an AC induction motor with a DC motor and speed control, consideration must be given to the maximum torque requirements. The full load torque rating of the DC motor must be equal to, or greater than, that of the AC motor. Set Jumpers The BC200/BC201 have selectable jumpers which must be set before the control can be used. Refer to Figure 2-1 for jumper locations. J1A, J1B - Input AC Line Voltage Select proper input line voltage, 115VAC or 230VAC, by placing both jumpers (J1A and J1B) in the correct corresponding position, 115 or 230. Factory set for 230VAC shown in Figure 2-8. Figure 2-8 AC Line Voltage Select J2 - Armature Current Select the J2 position (2.5, 5, 7.5, 10, 15) closest to the rated motor current. See Figure 2-8 and Table 2-5. Note: The maximum output current is set to 150% of the J2 position, which may be readjusted using the FWD CL and REV CL trimpots. On Model BC200, position 10A is factory setting. Figure 2-9 J2 Position MN716 2-7

Table 2-5 J2 Position vs Motor Horsepower Jumper J2 Position Motor Current Motor Horsepower (DC AMPS) 90VDC 180VDC 15A (1) 1-1/2 3 10A 1 2 7.5A 3/4 1-1/2 5.0A 1/2, 1/3 1. 3/4 2.5A 1/4 1/2 J3 - Motor Armature Voltage Select the desired armature voltage by placing J3 in the proper position, 90 or 180. See Figure 2-1. Note: For 115 volt AC line input, the armature voltage must be set to 90. For 230 volt input, the armature voltage normally is set for 180. However, it is also possible to set the armature voltage to 90 for step-down operation. Table 2-6 Relationship of Voltage and Jumper Position AC Input Voltage J1A, J1B Position J3 Position Motor Voltage 115 115 90 90 230 230 180 180 230 230 90* 90* * A 90VDC motor can be used with a 230VAC line. However, speed range may be reduced and motor overheating may result. J4 Tachometer Voltage Place J4 in the position 7V, 20/30, 50V that corresponds to the tachometer voltage in Volts/1000. See Figure 2-9. Note: Selection of the jumper position is not required if armature feedback is used.) The tach voltage jumper position is based on motor speed of 1,800 RPM. For example, if the tach is 25V/1000 and the motor speed is 3,600 RPM, use the 50V position. For other tach voltages and motor speeds, an external resistor (RT) may be used as follows: 1. Place J4 in 7V position 2. Calculate the value of (RT) as follows: RT = [(5.4 x VT x S) 68,000] ohms VT = Tach Voltage in Volts/1000 RPM S = Base speed of motor in RPM Note: Choose the closest standard 1/2 watt resistor value to the calculated value. 3. Install resistor (RT) in series with either tachometer lead. Note: For tachometer feedback, Jumper J5 must be in the TFB position. J5 - FEEDBACK TYPE The BC200/BC201 can be operated in either armature feedback, AFB or tachometer feedback, TFB. Armature feedback provides adequate load regulation for most applications. For very precise performance, tachometer feedback, TFB should be used. Notes: 1. If tach feedback is desired, an external DC tachometer must be used and connected. 2. The IR Comp trimpot must be set to the minimum setting [CCW] for tachometer feedback. 2-8 MN716

J6 - Current Limit Mode (Factory set for TCL). The BC200/BC201 contains electronic current limiting which limits the maximum DC current to the motor, (the current limit set point is established with the setting of the CL trimpot). Two modes of current limit operation are provided: Timed Current Limit, TCL Note: For the Timed Current Limit feature to operate, the Start/Stop control circuit must be used. Also, the Timed Current Limit feature cannot be used in either torque mode since nuisance tripping will occur. In Timed Current Limit mode the drive will turn off after being in current limit for a preset time. This time period is adjustable with the TCL trimpot from 0.5 15 seconds and is factory set for approximately 5 seconds. To restart the control after it has timed out, the start button must be pressed. Non-Timed Current Limit, NTCL In this mode, the drive will reach preset Current Limit during overload and stay at that level until drive is turned off or fuse blows. If Non-Timed CL is desired, move jumper J6 from the factory set TCL position to the NTCL position. The NTCL position must be used when operating in the torque mode. J7 - Speed or Torque Control Described in Operation section of this chapter. J8 - Speed Linear Torque (S/L) and Non Linear Torque (NLT) Described in Operation section of this chapter. Startup After the control has been mounted properly and electrical connections have been completed and jumpers are correctly set, start the control as follows: 1. Verify the speed adjust potentiometer is set fully counterclockwise. 2. Apply AC power. 3. Observe the Power ON LED indicator is illuminated. If not on, refer to troubleshooting. 4. Verify correct direction of motor rotation. Start the control. The motor shaft should begin to rotate as the potentiometer knob is turned clockwise, or the analog speed reference signal is increased. Verify the motor shaft is rotating in the desired forward direction. If the direction of rotation is incorrect, stop the control and disconnect AC power. Switch the motor lead connections at the A+ and A- terminals. If a tachometer is connected, the leads may also need to be switched for correct signal polarity. If the CL LED is on, refer to troubleshooting. WARNING: If possible, do not adjust trim pots with the main power applied. Electrical shock can cause serious or fatal injury. If adjustments are made with the main power applied, an insulated adjustment tool must be used to prevent shock hazard and safety glasses must be worn. MN716 2-9

Trimpot Adjustments The BC200/BC201 contains trimpots, which are factory set for most applications. Figure 2-1 illustrates the location of the trimpots and their approximate calibrated positions. Some applications may require readjustment of the trimpots to tailor the control for a specific requirement. Readjust trimpots as needed. Forward Acceleration (FWD ACCEL) The FWD ACC trimpot determines the amount of time it takes the control voltage to reach full output in the forward direction. It also determines the amount of time it takes for the control voltage, in the reverse direction, to reach zero output. (FWD ACCEL also sets the Reverse Decel.) Reverse Acceleration (REV ACCEL) The REV ACC trimpot determines the amount of time it takes the control voltage to reach full output in the reverse direction and the time it takes for the control voltage, in the forward direction, to reach zero output. (REV ACC is the Forward Decel) The FWD and REV ACC trimpots are factory adjusted to 1 second. The acceleration times are adjustable to a maximum of 15 seconds. Notes: 1. The FWD and REV CL trimpots settings may override the rapid accel and decel settings. 2. BC211 4-quadrant ACC / DECEL accessory module is available as an option. It provides separate control of FORWARD acceleration and deceleration and REVERSE acceleration and deceleration. See Figure 2-10. Figure 2-10 Accel/Decel Trimpot Adjustment 100 Speed (%) 0-100 FWD ACCEL REV DECEL REV ACCEL Time FWD DECEL Offset This trimpot determines the amount of bias in the forward or reverse direction. The trimpot is factory set to provide approximately zero offset, which means neither the forward nor the reverse speed is favored. Adjust offset to suit application requirement. See Figure 2-11. Deadband (DB) The DB trimpot sets the amount of main speed potentiometer rotation required to initiate control voltage output. It is factory adjusted to approximately 25% of rotation. Adjust Deadband to suit application requirements by rotating the DB trimpot cw, (increase) or ccw (decrease). See Figure 2-12. The DB trimpot also determines the amount of delay that will occur before regeneration starts. (Regeneration occurs when the applied load torque is in the same direction as the motor rotation.) To readjust the DB to factory setting: a. Set Main Speed pot to zero speed position. b. Set DB trimpot to full CCW position. c. Adjust DB trimpot CW until motor hum is eliminated. 2-10 MN716

Figure 2-11 Offset Trimpot Adjustment 100 b a (%) SPEED c Figure 2-12 Deadband Trimpot Adjustment 100 a (%) SPEED b -100 (%) 100 MAIN SPEED POT ROTATION -100 CURVE OFFSET (a) None (b) Forward (c) Reverse -100 b a 100-100 Curve (a): No Deadband Curve (b): Max. Deadband Note: If the deadband trimpot is set too low (CCW direction), the motor may oscillate between forward and reverse. Adjust deadband trimpot CW until the instability disappears. (Oscillation may also occur due to response setting. Forward Current Limit (FWD CL) and Reverse Current Limit (REV CL) Caution: Adjusting the CL above 150% of motor rating can cause overheating and demagnetization of some PM motors. Consult motor manufacturer. Sets the maximum DC motor current for both the forward and reverse directions. The amount of DC current determines the amount of maximum motor torque in both the Speed Control Mode and Torque Mode. These CL trimpots are factory set at 150% of the motor current. The value can be reduced by adjustment of the CL trimpots. Some applications require a lower torque limiting value to prevent damage to the process material or the drive train. Re-Adjust the CL trimpots as follows: a. Turn CL trimpot to MIN (CCW) position. Be sure jumper J2 is in proper position approximately equal to the motor DC ampere rating. b. Connect in a DC ammeter in series with armature lead. Load shaft of motor in accordance with application requirements. c. Apply power; Rotate CL trimpot CW until desired CL setting is reached (factory setting is 1.5 times rated motor current). Be sure control is in Forward direction for FWD CL trimpot adjustment and likewise with REV CL. Note: do not stall motor shaft for more than 2-3 seconds, to prevent motor damage. IR Compensation (IR Comp) The IR Comp is used to stabilize motor speed under varying loads. If control is in Tach Feedback mode, the IR Comp should be set to minimum -CCW. Note: Too much IR Comp will cause unstable (oscillatory) operation. Re-Adjust the IR Comp trimpot as follows: a. Run motor at approximately 30-50% of rated speed under no load and measure actual speed. b. Load motor to rated current. Rotate IR Comp trimpot so that loaded speed is the same as the unloaded speed measured in the previous step. Control is now compensated so that minimal speed change will occur over a wide range of motor loads. MN716 2-11

Maximum Speed (MAX) The MAX trimpot is used to set the maximum output voltage of the control which, in turn, sets the maximum speed of the motor. In the Torque Control Mode, the MAX trimpot setting determines the unloaded motor speed. Adjust the MAX trimpot as follows: a. Rotate Main Speed potentiometer to full speed (CW). b. Adjust MAX trimpot to desired maximum motor speed. Note: Do not exceed maximum rated RPM of motor since unstable operation may result. Response (RESP) This trimpot determines the dynamic response of the control. The factory setting is approximately 50% of full rotation. The setting may be increased if a faster response is required. Note: If response is made too fast, unstable operation may result. Timed Current Limit (TCL) Trimpot Trimpot is used only when control is connected for 3-wire Start/Stop and J6 is in the TCL position. The TCL trimpot sets the delay time for the Timed Current Limit. The trimpot is adjustable over a time range of 1 15 seconds and is factory set for approximately 5 seconds. See Table 2-7. Calibrate the TCL trimpot by setting the trimpot to the approximate desired delay time. Table 2-7 Current Limit Timer Settings Approximate Trip Time (Seconds) Trimpot Position 1 Full CCW 8 Midway 15 Full CW Operation The input voltage can be derived from the wiper of the main speed potentiometer or from an isolated analog input (voltage following mode). Since the BC200/BC201 are 4-quadrant regenerative drives, the motor speed will follow both a positive and negative wiper voltage and drive the motor in both the forward direction and reverse direction. In addition, it will apply both forward and reverse torque to stabilize motor speed. The BC200/BC201 can be operated as speed control or torque control by setting the position of jumper J7. The main speed potentiometer controls the magnitude of the mode selected. Set jumper J7 to SPD for speed control or to TRQ for torque control. Speed or Torque Control When jumper J7 is set to the SPD position, motor speed is a function of the voltage on input terminals 12 (signal) and 13 (common). Note: When J7 is set for speed control (SPD), J8 must be set to S/L position (factory setting). Table 2-8 Summary of Control (REGEN) Operation Quadrant Type of Operation Motor Rotation Direction Motor Torque Direction Applied Load Direction I Motoring CW CW CCW II Regeneration CCW CW CCW III Motoring CCW CCW CW IV Regeneration CW CCW CW 2-12 MN716

Torque Control Mode When Jumper J7 is set to TRQ position, the BC200/BC201 will control motor torque. Two types of torque characteristics are selectable with jumper J8, Speed Linear Torque (S/L) and Non Linear Torque (NLT). In the S/L position (factory setting), both output torque and motor speed vary linearly as a function of the analog input signal. The S/L type of torque is most suitable for take up and payout winders where the speed and torque requirements vary as the winder roll diameter changes. The S/L torque characteristics are shown in Figure 2-13. Figure 2-13 Linear Torque Curve 100 90 80 70 60 50 40 30 MOTOR SPEED (%) 20 10 0 HIGHER TORQUE SETTING LOWER TORQUE SETTING 0 10 20 30 40 50 60 70 80 90 100 TORQUE (%) In the NL position, only torque (not speed) is varied by the input signal. The motor output torque remains constant over the motor s full speed range unless the load is less than the set torque. If the load torque decreases below the set torque, the motor will rapidly increase to full speed. This type of torque control is applicable to processes where the torque must remain constant over a wide motor speed range. The NL torque characteristics are shown in Figure 2-14. Figure 2-14 Non-Linear Torque Curve 100 80 SPEED 60 40 LOWER TORQUE SETTING HIGHER TORQUE SETTING 20 0 0 10 20 30 40 50 60 70 80 90 100 TORQUE (%) Because the BC200/BC201TM are regenerative controls, torque will be applied in both forward and reverse directions. The maximum torque can be set with the FWD CL and REV CL trimpots, and by using the FWD ACC and REV ACC trimpots, the rate of change of torque can be made more or less gradual. The maximum speed trimpot can be used to set the maximum motor speed under a no load condition. MN716 2-13

Troubleshooting The control has LEDs to display the control s operational status. A. Power On This lamp indicates AC power is applied to the control. B. CURRENT LIMIT (CL) Indicates that the drive is in Current Limit. If set in the timed Current Limit mode (J6 set to TCL) and has timed out, the LED 2 will remain ON until the drive is restarted. C. Forward Enable (FWD EN) Indicates that the drive is engaged in the forward direction. [Enable circuit closed, (terminals 8 and 9), the start circuit asserted and a forward speed command.] The FWD EN lamp will also be lighted in the reverse direction if the control is in regeneration. D. Reverse Enable (REV EN) Indicates that the drive is engaged in the reverse direction. [Enable circuit closed (terminals 8 and 9), the start circuit asserted and a reverse speed command.] The REV EN lamp will also be lighted in the forward direction if the control is in regeneration. Table 2-9 Troubleshooting Guide Indication / Symptom Motor is not running and Power On LED indicator is illuminated. Power ON LED indicator is not illuminated. Motor runs then stops after a short time or, The Drive trips due to overload (TCL Fault). Line fuse blows or circuit breaker trips. Logic Control Board fuse, F1, blows. Possible Soloutions Start-Stop switch is in the STOP position. If this mode is used, place the switch in the START position. The Main Speed Potentiometer is set to zero speed. Set the Main Speed Potentiometer for the desired speed. The Main Speed Potentiometer, signal input, or motor connections are open. Verify Main Speed Potentiometer, signal input, or motor connections. Check AC Line connections have been made. Verify correct wiring. Check AC Line fuse. The drive must be manually restarted by disconnecting and reconnecting the AC power. Reduce load. The line fuse or circuit breaker installed is the incorrect rating. See Table 1-4 for the correct line fuse or circuit breaker rating. Check for loose or damaged wiring. Check to see if signal or control wiring is not shorted or grounded. Verify Start/Stop switch, Enable switch, and Speed Adjust pot are operating properly and are not shorted or grounded. Motor is overloaded. Check motor amps with DC ammeter in series with armature. (If motor is shunt type, field may be open or not receiving proper voltage.) CL LED indicator is illuminated. Check motor for shorts or grounds. Motor may be defective. Check position of CL trimpot. The CL may be set too low. Rapid Acceleration change will cause the LED to illuminate. Verify potentiometer setting. Motor runs at high speed and does not respond to Check field wiring. If using tachometer feedback, check main adjust speed pot or reference signal. tachometer signal. Note: For any other problems, consult your local Baldor District Office. 2-14 MN716

UNITED STATES ARIZONA PHOENIX 4211 S 43RD PLACE PHOENIX, AZ 85040 PHONE: 602-470-0407 FAX: 602-470-0464 ARKANSAS CLARKSVILLE 706 WEST MAIN STREET CLARKSVILLE, AR 72830 PHONE: 479-754-9108 FAX: 479-754-9205 CALIFORNIA LOS ANGELES 6480 FLOTILLA STREET COMMERCE, CA 90040 PHONE: 323-724-6771 FAX: 323-721-5859 HAYWARD 21056 FORBES STREET HAYWARD, CA 94545 PHONE: 510-785-9900 FAX: 510-785-9910 COLORADO DENVER 3855 FOREST STREET DENVER, CO 80207 PHONE: 303-623-0127 FAX: 303-595-3772 CONNECTICUT WALLINGFORD 65 SOUTH TURNPIKE ROAD WALLINGFORD, CT 06492 PHONE: 203-269-1354 FAX: 203-269-5485 FLORIDA TAMPA/PUERTO RICO/ VIRGIN ISLANDS 3906 EAST 11TH AVENUE TAMPA, FL 33605 PHONE: 813-248-5078 FAX: 813-241-9514 GEORGIA ATLANTA 62 TECHNOLOGY DRIVE ALPHARETTA, GA 30005 PHONE: 770-772-7000 FAX: 770-772-7200 ILLINOIS CHICAGO 340 REMINGTON BLVD. BOLINGBROOK, IL 60440 PHONE: 630-296-1400 FAX: 630-226-9420 Baldor District Offices INDIANA INDIANAPOLIS 5525 W. MINNESOTA STREET INDIANAPOLIS, IN 46241 PHONE: 317-246-5100 FAX: 317-246-5110 IOWA DES MOINES 1943 HULL AVENUE DES MOINES, IA 50313 PHONE: 515-263-6929 FAX: 515-263-6515 MARYLAND BALTIMORE 7071A DORSEY RUN RD ELKRIDGE, MD 21075 PHONE: 410-579-2135 FAX: 410-579-2677 MASSACHUSETTS BOSTON 6 PULLMAN STREET WORCESTER, MA 01606 PHONE: 508-854-0708 FAX: 508-854-0291 MICHIGAN DETROIT 5993 PROGRESS DRIVE STERLING HEIGHTS, MI 48312 PHONE: 586-978-9800 FAX: 586-978-9969 MINNESOTA MINNEAPOLIS 13098 GEORGE WEBER DR, SUITE 400 ROGERS, MN 55374 PHONE: 763-428-3633 FAX: 763-428-4551 MISSOURI ST LOUIS 13678 LAKEFRONT DRIVE EARTH CITY, MO 63045 PHONE: 314-373-3032 FAX: 314-373-3038 KANSAS CITY 9810 INDUSTRIAL BLVD. LENEXA, KS 66215 PHONE: 816-587-0272 FAX: 816-587-3735 NEW YORK AUBURN ONE ELLIS DRIVE AUBURN, NY 13021 PHONE: 315-255-3403 FAX: 315-253-9923 NORTH CAROLINA GREENSBORO 1220 ROTHERWOOD ROAD GREENSBORO, NC 27406 PHONE: 336-272-6104 FAX: 336-273-6628 OHIO CINCINNATI 2929 CRESCENTVILLE ROAD WEST CHESTER, OH 45069 PHONE: 513-771-2600 FAX: 513-772-2219 OHIO (Continued) CLEVELAND 8929 FREEWAY DRIVE MACEDONIA, OH 44056 PHONE: 330-468-4777 FAX: 330-468-4778 OKLAHOMA TULSA 5555 E. 71ST ST., SUITE 9100 TULSA, OK 74136 PHONE: 918-366-9320 FAX: 918-366-9338 OREGON PORTLAND 16201 SE 98TH AVENUE CLACKAMAS, OR 97015 PHONE: 503-691-9010 FAX: 503-691-9012 PENNSYLVANIA PHILADELPHIA 103 CENTRAL AVENUE SUITE 400B MOUNT LAUREL, NJ 08054 PHONE: 856-840-8011 FAX: 856-840-0811 PITTSBURGH 159 PROMINENCE DRIVE NEW KENSINGTON, PA 15068 PHONE: 724-889-0092 FAX: 724-889-0094 TENNESSEE MEMPHIS 4000 WINCHESTER ROAD MEMPHIS, TN 38118 PHONE: 901-365-2020 FAX: 901-365-3914 TEXAS DALLAS 2920 114TH STREET SUITE 100 GRAND PRAIRIE, TX 75050 PHONE: 214-634-7271 FAX: 214-634-8874 HOUSTON 10355 W. LITTLE YORK ROAD SUITE 300 HOUSTON, TX 77041 PHONE: 281-977-6500 FAX: 281-977-6510 UTAH SALT LAKE CITY 2230 SOUTH MAIN STREET SALT LAKE CITY, UT 84115 PHONE: 801-832-0127 FAX: 801-832-8911 WISCONSIN MILWAUKEE 1960 SOUTH CALHOUN ROAD NEW BERLIN, WI 53151 PHONE: 262-784-5940 FAX: 262-784-1215 INTERNATIONAL SALES FORT SMITH, AR P.O. BOX 2400 FORT SMITH, AR 72902 PHONE: 479-646-4711 FAX: 479-648-5895