FOR PROPER AND SAFE INSTALLATION OF THIS PRODUCT, PLEASE READ THE FOLLOWING INSTRUCTIONS.

Similar documents
Installation Instructions for Appleton Mercmaster LED Luminaire

INSTRUCTION SHEET. Installation Instructions for Mercmaster LED Luminaire. Applications. Agency Ratings. Product Safety

Industrial Mercmaster LED Low Profile Luminaires For Ordinary Locations

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

F1-1. HID Lighting: Enclosed and Gasketed. Description. 2, 3 Mercmaster III Family Tree Mercmaster III HID Low Profile Lighting Fixtures

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Making the Move From HID to LED Painless, Easy and Cost Effective.

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

IMPORTANT SAFETY INSTRUCTIONS

VSQ SERIES 30 AMP INTERLOCKED SWITCHED RECEPTACLES

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

Operating Instructions

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit.

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

HID/AREA: NEC/CEC ENCLOSED AND GASKETED. Applications

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

N2MV Series W Non-metallic

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

SafeSite LED Area Light Technical Specifications

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Vigilant LED Area Light Technical Specifications

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

LED IMPORTANT SAFETY INSTRUCTIONS

Prismpack V, Prismalume V, Large Prismpack, Large Prismalume

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

SynergEX Panelboards for Hazardous Locations

VWSQ SERIES 30 AMP INTERLOCKED SWITCH RECEPTACLES

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

DuroSite LED Area Light - UL / CSA for Indoor and Outdoor Industrial Applications

Applications. Standard Materials. Certifications and Compliances

Table of Contents General Information Safety Message Classifi cation...2 Safety Notes...3 Terminology...4 Coupler Lifting Lug...

Applications. Standard Materials

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

DuroSite LED Area Light - UL / CSA for Indoor and Outdoor Industrial Applications

SecoVac * Ground & Test Device

KH Series Kemlux III Enclosed/Gasketed

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

UNITIZED batching INSTaLLaTION guide

ibusway for Data Center

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing

Lighting: Explosionproof Area HID. Applications. Standard Materials

LED Security Wallpack Installation Instruction

Type 2000 Transducer Product Instructions

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

FOR USE WITH MODEL NUMBERS:

Ex eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B)

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

RIGID ENTRY BOOT INSTALLATION GUIDE

MODELS. 2 & 4 Low Profile Linears

Applications. Illustrated Features

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

MODELS 2 & 4 Top Conduit Linears

DRAFT. Installation, Operation and Maintenance Instructions for Emerson KBG-V Series

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Extended Battery Cabinet for Nfinity

King Dome. user manual

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Brake System H TX, H2.0TXS [B475]; H TX [B466] Safety Precautions Maintenance and Repair

Installation and Service Instructions for Self Adjust Brakes 81,000 Series

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Low Profile Tailgate Spreaders SWING AWAY Mount

LED IMPORTANT SAFETY INSTRUCTIONS

Albany RR1000. Mechanical Installation Manual. PN: 6410T0029 Version - Rev: 04/23/2014. ASSA ABLOY Entrance Systems

INSTALLATION & OWNER S MANUAL

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500

Disassembly and Reassembly for WG Series Worm Gear Operator. User Instructions Part Number: XXXXXX, Rev. 0 Release: February 2017

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Installation and Service Instructions for Self Adjust Brakes 82,000 Series

Champ MLL LED luminaires

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

LED UFO High Bay with j-box Installation Instruction

I. Pendant Mount Installation

Areamaster LED Flood/High Bay Luminaires

SEALING DIP CAP INSTALLATION GUIDE

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Alphanumeric Index ALPHANUMERIC INDEX. xxviii

COMPACT FLUORESCENT EMERGENCY FIXTURES

Applications. Standard Materials. Certifications and Compliances

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Transcription:

Installation Instructions for Mercmaster LED Low Profile Luminaire Fittings 650499-000 INSTRUCTION SHEET FOR PROPER AND SAFE INSTALLATION OF THIS PRODUCT, PLEASE READ THE FOLLOWING INSTRUCTIONS. Product Safety Signal Words Defined DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE is used to address practices not related to physical injury. Safety Instructions for Complete Luminaire WARNING Do not open or remove the luminaire with the circuit energized. Do not use this luminaire on ungrounded systems. Failure to ground the luminaire can result in an electric shock, which may be fatal. Before installation, ensure that the unit complies with the hazardous area classification. Refer to luminaire nameplate, located on exterior of housing body, for suitability in specific hazardous locations. CAUTION: Do not look directly at the LEDs when energized. Disconnect the luminaire from the supply circuit before opening to reduce the risk of ignition in hazardous atmospheres. It is necessary that the globe and all conduit plugs are tightly secured and all luminaire fittings (mounting hood and optic) are tightly secured to the LED housing to prevent water and dust entry. The optic should be cleaned periodically to maintain lighting efficiency. NOTICE: Do not touch the LEDs; touching could leave oily deposits, causing hot spots and potential premature failure. This luminaire is designed for and should be installed with hazardous locations wiring method required in accordance with the National Electrical Code /Canadian Electrical Code and all applicable local codes. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazards involved. Do not use this equipment for anything other than its intended use. Applications/Intended Use The luminaire fittings below are to be used to assemble a complete luminaire with other listed hazardous location luminaire fittings. A family tree of these products appears at the end of this document. Class I, Division 2, Groups A, B, C, and D; Class II, Division 2, Groups F and G. LED Housing with Optic Factory Installed: Cat. Nos. MLLED, followed by 2, 3, or 4, followed by, P5, D5, G5, J1, J3, or J5 followed by BU or BH (i.e. MLLED2P5BU). LED Housing: Cat. Nos. MLLED, followed by 2, 3, or 4, followed by BU or BH (i.e. MLLED2BU). Optics (Globes): Cat. Nos. VPGL-DIFF, VPGL-LED, VPGL-GLASS, LPG-R1, LPG-R3, or LPG-R5. Class I, Division 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F and G. LED Housing with Optic Factory Installed: Cat. Nos. MLLED, followed by 2, 3, or 4, followed by G5, J1, J3, or J5, followed by BU or BH (i.e. MLLED2J5BU). LED Housing: Cat. Nos. MLLED followed by 2, 3, or 4, followed by BU or BH (i.e. MLLED2BU). Optics (Globes): Cat. No. VPGL-GLASS, LPG-R1, LPG-R3, or LPG-R5. 650499-000 Rev. M 4/16 Page 1 of 10

Applications/Intended Use (continued) For marine and wet locations apply a corrosion-inhibiting grease, such as petroleum or soap-thickened mineral oils, in 3 lines, spaced approximately 120 degrees apart, perpendicular to the threads. Tighten all unused close-up plugs. Areas where flammable gases and vapors are present under conditions defined by the ratings below. Areas of low clearance, low ceiling heights, or where luminaire weights must be minimized. Non-hazardous locations where severe weather conditions, excessive moisture, dirt, dust, corrosive atmospheres, and high ambient temperatures are encountered. Agency Ratings j Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division I, Groups E, F, G l Class II, Division 2, Groups F, G Class III Marine Outside Type (Salt Water) for USA only m Type 3R, 4, 4X IP66 NOTES: j Refer to product nameplate, located on the exterior of the housing body for details. Polycarbonate globes are not suitable for Class II, Division 1 applications. l Assembled luminaire with polycarbonate globes are not suitable for Class II, Division 1 applications. m To be installed in accordance with CG-259 of American Bureau of Shipping and Coast Guard. Dimensions Pendant Mount Pendant Cone Mount 650499-000 Rev. M 4/16 Page 2 of 10

Dimensions (continued) Ceiling Mount Wall Mount Angle Stanchion Mount 650499-000 Rev. M 4/16 Page 3 of 10

Dimensions (continued) Stanchion Mount Mounting Hoods Mounting Pendant Hood Installation (KPA-75, KPA-100, KPA-100, KPAF-75, KPAF-75, KPAF-100) KPAF-100) Pendant: Mounting: KPA-75, Mounting: KPA-100 1. Apply tlc-3 grease in approximately three equal lines, spaced equally apart on the conduit stem. thread the pendant hoo 1. Apply 1. a Apply corrosion-inhibiting tlc-3 grease grease, in approximately such as petroleum three or equal soap-thickened lines, spaced mineral equally oils, in apart 3 lines, on spaced the conduit approximately stem. thread the pendan 120 degrees the 3/4 apart inch perpendicular or 1 inch conduit the 3/4 inch or 1 inch conduit to the stem. threads stem. on the conduit stem. Thread the pendant hood onto the 3/4 inch or 1 inch conduit 2. tighten stem. the set screw inside the hood. 2. tighten the set screw inside the hood. 2. Tighten the set screw inside the hood. JCT BOX JCT BOX CONDUIT CONDUIT STEM STEM SET SCREW (INSIDE SET SCREW HOOD) (INSIDE HOOD) CEILING CEILING PENDANT HOOD PENDANT HOOD Pendant Cone (KPCH-75, KPCH-100) Pendant Cone (KPCH-75, KPCH-100) Pendant Cone: KPCH-75, Mounting: KPCH-100 1. Apply a corrosion-inhibiting grease, such as petroleum or soap-thickened mineral oils, in 3 lines, spaced approximately 1. Mounting: Apply tlc-3 grease in approximately three equal lines, spaced equally apart on the conduit stem. thread the pendant con 120 degrees apart perpendicular to the threads on the conduit stem. Thread the pendant cone hood onto the 3/4 inch or 1 inch conduit 1. onto Apply stem. the tlc-3 3/4 inch grease or 1 in inch approximately conduit stem. three equal lines, spaced equally apart on the conduit stem. thread the pendan 2. tighten 2. Tighten onto the set the the screw. 3/4 set inch screw. or 1 inch conduit stem. 2. tighten the set screw. CONDUIT STEM CONDUIT STEM SET SCREW SET SCREW Ceiling (KPC-75, KPC-100) 650499-000 Rev. M 4/16 Page 4 of 10

Mounting Hood Installation (continued) Ceiling: KPC-75, KPC-100 1. Bolt the ceiling hood directly to a structural member; thread onto a 3/4 inch or 1 inch conduit stem. 2. Remove unused conduit plugs and reinstall with a corrosion-inhibiting grease, such as petroleum or soap-thickened mineral oils, in 3 lines, spaced approximately 120 degrees apart perpendicular to the threads on the conduit plugs. the conduit plugs. CONDUIT ENTRIES (5x) Wall: KPWB-75, KPWB-100 1. Bolt the wall hood to a structural member. 2. Remove unused conduit plugs and reinstall a corrosion-inhibiting grease, such as petroleum or soap-thickened mineral oils, in 3 lines, spaced approximately 120 degrees apart perpendicular to the threads on the conduit plugs. CONDUIT ENTRY (5x) 25 Stanchion: KPS-125, KPS-150 1. Apply a corrosion-inhibiting grease, such as petroleum or soap-thickened mineral oils, in 3 lines, spaced approximately 120 degrees apart perpendicular to the threads on the conduit. 2. Thread the stanchion hood onto the 1-1/4 inch or 1-1/2 inch conduit. NOTE: Five full threads must be engaged. 3. Determine the appropriate orientation and tighten the set screw. SET SCREW 90 Stanchion (KPST-125, KPST-150) 650499-000 Rev. M 4/16 Page 5 of 10

Mounting Hood Installation (continued) 90 Stanchion: KPST-125, KPST-150 1. Apply a corrosion-inhibiting grease, such as petroleum or soap-thickened mineral oils, in 3 lines, spaced approximately 120 degrees apart perpendicular to the threads on the conduit stem. Thread the stanchion hood onto the 1-1/4 inch or 1-1/2 inch conduit stem. NOTE: Five full threads must be engaged. 2. Determine the appropriate orientation and tighten the set screw. 2. determine the orientation and tighten the set screw. SET SCREW LED Housing Installation WARNING: The luminaire must be grounded as required by the National Electrical Code (Paragraph 410-21 and Article 250) or Canadian Electrical Code (Rule 30-500 and Section 10). Verify that ground continuity has been established by using an Ohm meter or other suitable test equipment before energizing the luminaire. Failure to properly ground the luminaire will create an electric shock hazard, which can cause serious injury or death. 1. Disconnect facility power to the electric power supply leads. 2. Feed the proper temperature supply wire into the mounting hood. See the product nameplate for supply wire requirements. 3. Hang the LED housing on the hinge; secure with the hinge pin. 4. Strip the individual conductors to bare wire and insert them into the proper terminal block connections. Tighten down the terminal block screws onto the wire. Suitable power: 120 277 V, 50/60 Hz for BU and 347 480 V, 50/60 Hz for BH. 650499-000 Rev. M 4/16 Page 6 of 10

LED Housing Installation (continued) MLLED4BU MLLED2BU AND MLLEDBU MLLED4BH MLLED2BH and MLLED3BH 5. Housing requires bonding to mounting hood. Connect housing bond wire to GREEN ground screw on the mounting hood. 6. Fold all excess supply leads and fasten them into the mounting hood with the wire tie (supplied) to avoid pinching the wires. 7. Swing the LED housing up and tightly secure with the hex nut and washer combination. 650499-000 Rev. M 4/16 Page 7 of 10

Optic Installation Globe/Refractor: VPGL-LED, VPGL-DIFF, VPGL-GLASS, VPGL-3HR, LPG-R1, LPG-R3, LPG-R5 1. Thread the new globe or refractor onto the housing clockwise. 2. After the globe or refractor contacts the gasket surface, tighten a 1/4 to a 1/2 turn with strap wrench. Guard Installation Guard: KRG2, MGU1 1. Loosen, do not remove, three (3) screws located around the perimeter of the luminaire housing. 2. Install guard, making sure the screw heads capture the mounting feet/ring. 3. Tighten three (3) screws. Reflector Installation Reflector: CMR4AN, CMR4ST 1. Loosen, do not remove, three (3) screws located around the perimeter of the luminaire housing. 2. Install reflector, using the keyhole slots. Rotate the reflector to make sure the screw heads capture the mounting surface. 3. Tighten three (3) screws. Optional Factory Installed Photocontrol for Hazardous Locations Photocell: KPA75PC120D2, KPA100PC120D2, KPA75PC247D2, KPA100PC247D2, KPWB75PC120D2, KPWB100PC120D2, KPWB75PC247D2, KPWB100PC247D2, KPS75PC120D2, KPS100PC120D2, KPS75PC247D2, KPS100PC247D2, KPST75PC120D2, KPST100PC120D2, KPST75PC247D2, KPST100PC247D2 1. Complete the wire connections per the appropriate diagram below. MLLED4BU-PHOTOCONTROL NOTES: MLLED2BU and MLLED3BU-PHOTOCONTROL Available photocontrol: PC120D2 for 120V ac; PC247D2 for 208-277V ac. Photocontrol does not fit ceiling or pendant cone mounting hoods. Photocontrol provides automatic dusk-to-dawn lighting control in Class I, Division 2 locations only. Luminaires with photocontrol are not rated IP66, Class II, 3R, or 4X. 650499-000 Rev. M 4/16 Page 8 of 10

Mercmaster LED Low Profile Luminaire Family Tree Pendant Mount with Photocelllm Wall Mount with Photocelllm 25 Stanchion Mount with Photocelllm 90 Stanchion Mount with Photocelllm [120 V] 3/4 in. KPA75PC120D2 [120 V] 1 in. KPA100PC120D2 [208 277 V] 3/4 in. KPA75PC247D2 [208 277 V] 1 in. KPA100PC247D2 [120 V] 3/4 in. KPWB75PC120D2 [120 V] 1 in. KPWB100PC120D2 [208 277 V] 3/4 in. KPWB75PC247D2 [208 277 V] 1 in. KPWB100PC247D2 [120 V] 1-1/4 in. KPS75PC120D2 [120 V] 1-1/2 in. KPS100PC120D2 [208 277 V] 1-1/4 in. KPS75PC247D2 [208 277 V] 1-1/2 in. KPS100PC247D2 [120 V] 1-1/4 in. KPST75PC120D2 [120 V] 1-1/2 in. KPST100PC120D2 [208 277 V] 1-1/4 in. KPST75PC247D2 [208 277 V] 1-1/2 in. KPST100PC247D2 Pendant Mount Pendant Cone Mount Ceiling Mount Wall Mount 25 Stanchion Mount 90 Stanchion Mount 3/4 in. KPA-75 1 in. KPA-100 3/4 in. KPCH-75 1 in. KPCH-100 3/4 in. KPC-75 1 in. KPC-100 3/4 in. KPWB-75 1 in. KPWB-100 1-1/4 in. KPS-125 1-1/2 in. KPS-150 1-1/4 in. KPST-125 1-1/2 in. KPST-150 MLLED Series with Glass Globe MLLED Series with Polycarbonate Globe MLLED Series MLLED Series with Type V Refractor Description (5700K CCT) MLLED2G5BU MLLED3G5BU MLLED4G5BU MLLED2G5BH MLLED3G5BH MLLED4G5BH Description (5700K CCT) Clear MLLED2P5BU MLLED3P5BU MLLED4P5BU MLLED2P5BH MLLED3P5BH MLLED4P5BH Diffused MLLED2D5BU MLLED3D5BU MLLED4D5BU MLLED2D5BH MLLED3D5BH MLLED4D5BH Description (5700K CCT) MLLED2BU MLLED3BU MLLED4BU MLLED2BH MLLED3BH MLLED4BH Description (5700K CCT) MLLED2J5BU MLLED3J5BU MLLED4J5BU MLLED2J5BH MLLED3J5BH MLLED4J5BH Polycarbonate Globes Glass Globe Glass Refractors Closed Prismatic Light Dist. NEMA Type V Clear NEMA Type V Diffused VPGL-LED VPGL-DIFF Light Dist. NEMA Type V VPGL-GLASS Light Dist. NEMA I NEMA III NEMA V LPG-R1 LPG-R3 LPG-R5 Globe Guards (Optional Accessory) Refractor Guard (Optional Accessory) MGU1 KRG2 NOTES: Globe/refractors are factory installed to the MLLED housing before shipping. Polycarbonate globes are not Class II, Division 1. l Assembled luminaire with photocontrols are not suitable for Class II, IP66, 3R and 4X applications. m Photocontrols not available for 347 480V ac (BH) luminaires. White Polyester Reflector (Optional Accessory) Description 30 Angle Standard Dome CMR-4AN CMR-4ST 650499-000 Rev. M 4/16 Page 9 of 10

Except as expressly provided by Appleton Grp, LLC (Appleton), Appleton products are intended for ultimate purchase by industrial users and for operation by persons trained and experienced in the use and maintenance of this equipment and not for consumers or consumer use. Appleton warranties DO NOT extend to, and no reseller is authorized to extend Appleton s warranties to any consumer. While every precaution has been taken to ensure accuracy and completeness in this manual, Appleton Grp, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. The Appleton and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. 2015 Appleton Grp, LLC. All rights reserved. 650499-000 Rev. M 4/16 Page 10 of 10