Note: Supply from an underground network often requires use of stud type connector. Consult your local utility.

Similar documents
Microlectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units

Microlectric Meter Sockets. Smart solutions that save you time and money

Accessories. Stainless Steel Sealing Rings. Polycarbonate Sealing Ring. Description S102WD Ring, available with any meter socket

PRODUCT BROCHURE Microlectric Highly corrosion-resistant meter sockets for harsh environments

Accessories. Stainless Steel Sealing Rings. Description MSR-C2. Polycarbonate Sealing Ring. Description S102WD Ring, available with any meter socket

Meter Sockets METER SOCKET ACCESSORIES MSR-C MSRP-C MP01 MP02. Stainless Steel Meter Rings. Stainless Steel Ring SM002A. Acrylic Sealing Ring S102WD

Multiple Metering, Horizontal Gang - Non Lever Bypass

Multiple Metering, Vertical Gang

POWER PRODUCT Meter Centres Contents

Accessories. Accessories. Meter Mounting Equipment

16 17F 18F 19F 16 17F 18F 19F 16 17F 18F 19F 16 17F 18F 19F 16 17F 18F 19F 16 17F 18F 19F 16 17F 18F 19F

Lithium-Ion Battery-Powered Tools

JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018

Armoured Cable/Flex. Conduit

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

SAFETY SOCKET BOX. Note 8 3" MIN. 3" Max. (200 A)

Metering NEED. Meter Sockets. Product Description

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

New York City Apartment Metering Meter Sockets / Load Centers

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

FROM B.C. HYDRO ENCLOSURE (SEE NOTE 4) RIGID CONDUITS (SEE NOTE 8) ALTERNATIVE TO LOAD BARRIER (SEE NOTE 7) SERVICE ENTRANCE ENCLOSURE

Brantford Power Inc. METERING SPECIFICATION Page 1

Equipment. Metering. Metering Equipment 1. Contents

Brantford Power Inc. METERING SPECIFICATION Page 1

For vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed

Section 6 Electric Metering: Residential

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Conduit Bushings for Rigid Metal Conduit and IMC

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

Canadian Federal and Provincial Fiscal Tables

Group Meter Main - Without Bypass

Single Socket and Horizontal Metering

320A Single Phase URD Meter Loop Installations

Equipment. Metering. Metering Equipment 1. Contents

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE

Seismic Sensor Accessories SA, SV & ST 6000 Series

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Canadian Motor Vehicle Traffic Collision Statistics

5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

AMENDMENT ELECTRIC SERVICE MANUAL 2014

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

Introduction. Upon completion of Basics of Meter Mounting Equipment

Electricity Exports and Imports

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

UNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.

Wide Single Tires (WST) in Canada Presentation to Task Force on VW&D Policy. Montreal November 29, 2017

Customer Requirements Meter Socket Configurations

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

Options: PART NUMBER MAIN BREAKER PHASE VOLTAGE

CT Metering. CT Metering. Meter Mounting Equipment

Quick Connection Panel (QCP) Installation Guide

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Meter Centers Meter Mounting Devices

Selection and application guide

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve

Selection and application guide. For use in Texas. Meter Mounting Equipment.

Underground Distribution

Selection and application guide

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

Approved Meter Sockets and Cabinets

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

MP Meter-Pak Meter Centers

BREAKER TRAY BACK/BOTTOM

Selection and application guide. For use in Kansas, Iowa, Missouri and Illinois. Meter mounting equipment.

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications

UNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.

Meter Mounting Equipment DTE Energy Area

Selection and application guide

Installation. InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD80G6FK1-M PD80G6FK1-M-14

Cable-Operated Disconnect Switches. Accessories

2013 Migration Patterns traffic flow by state/province

fastfax Rock Solid TM Load Centers General Information

Pretest Module 24 Three-phase Service Entrance

P&C Flex. Non-Metallic Rigid Conduit, Fittings and Accessories. Corrugated Flexible Conduit. Applications

Applications. Innovative Solutions For Wire and Cable Management

Connecting Tips. Insulation Displacement Connectors

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

2016 Migration Patterns traffic flow by state/province

Selection and application guide

GSC CONDUIT FITTING SOLUTIONS PRODUCT CATALOG

Easy-On II Terminations

Collected in cooperation with the Canadian Council of Motor Transport Administrators. Canadian Motor Vehicle Traffic Collision

TCI5125 Dusttight Grip " 1.50"NPT Ins

The selection of lengths and fittings in a variety of

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

americanfittingscorp.com t: e:

STUD WELDING EQUIPMENT & ACCESSORIES CATALOG

Item Code Description Unit Qty Total

Modular Metering. Canadian Version

Meter Mounting Equipment Wisconsin Area

Instrument Rated Metering Equipment

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering

Transcription:

BQ2 Series 200 A 600 V; Standard Enclosure Conductor range: 6 AWG 250 kcmil Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination overhead/underground Primarily used in: All provinces Note: Supply from an underground network often requires use of stud type connector. Consult your local utility. 5-3/32 in. (BQ2-V) -/4, -/2, 2 and 2- -/4, -/2, 2 and 2-2-/4 in. 29/64 in. -/32 in. 2-7/32 in. 4-3/8 in. COMBINATION AND UNDERGROUND BOTTOM K.O. /4 in. 3-3/4 in. 3-7/64 in. K.O. Trade size OVERHEAD BOTTOM 5-5/6 in. -3/6 in. Approved for copper and aluminum Cat. No BQ2-V Overhead, hub opening BQ2- /2 V Overhead, hub opening c/w - hub BQ2-2V Overhead, hub opening c/w 2 in. hub BQ2-TV Underground BQ2-TCV Combination, overhead-underground BQ2-22VNH Overhead, twin hub opening BQ2-22V Overhead, twin hub opening c/w 2 in. hubs BQ2-2VR Overhead, twin hub opening c/w 2 in. hub for B.C FACTORY INSTALLED ACCESSORIES Include: -GN Ground lug on neutral -5 5 th jaw standard capacity -6 5 th jaw full capacity, 6 o clock position 5-5/8 8-47/64 5-3/32 2 5.4 D5

BP2-TV 200 A 600 V; Standard Enclosure Conductor range: 6 AWG 250 kcmil Aluminum tunnel type connectors for both load and line sides For underground service only Primarily used in: Ontario (BP2-TV) -/4, -/2, 2 and 2-3 Sets /4 in. 7/6 in. 2-3/6 in. - 3/6 in. 3-3/6 in. 2 in. 3-3/6 in. 2-/6 in. 2-3/8 in. BP2-TV Underground 20 2 5-7/6 6.5 7.48 D6

BS2 Series 200 A 600 V; Oversize Enclosure Conductor range: 6 AWG-250 kcmil Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination overhead/underground Primarily used in: B.C., AB, Sask., Man., Ont., N.S. * May be use in all regions NOTE: Supply from an underground network often requires use of stud type connector. Consult your local utility. -/4, -/2, 2 and 2- (BS2-V), -/4, -/2, 2, 2-/2 and 3 in. - TYPICAL BOTTOM 2-/4 in. /4 in. K.O. 4-3/6 in. BC HYDRO BOTTOM, -/4, -/2, 2 and 2-2-3/6 in. Cuivre et aluminium BS2-V Overhead, hub opening BS2- /2 V Overhead, hub opening c/w - hub BS2-2V Overhead, hub opening c/w 2 in. hub BS2-TV Underground 7-/8 BS2-TCV Combination, overhead-underground BS2-TCVBC Combination overhead-underground for British Columbia only 2 5-7/6 4 6.3 BS2-TCVFA* Combination OH and UG (Fortis Alberta approved) c/w 350 kcmil lug 27-7/6 BS2-22VNH Overhead, twin hub opening BS2-22V Overhead, twin hub opening c/w 2 in. hubs 7-/8 BS2-9-4V Overhead, hub opening c/w 5 th jaw, 9 o clock & insulated neutral FACTORY INSTALLED ACCESSORIES Include: -5 5 th jaw, standard capacity, 9 o clock position -6 5 th jaw, full capacity, 6 o clock position -9 5 th jaw, full capacity, 9 o clock position -IN Insulated neutral -GN Ground lug on neutral D7

BS2 Series Kit 200 A 600 V; Oversize Enclosure with PVC Accessories Conductor range: 6 AWG-250 kcmil Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination Primarily used in: Ontario only Note: Supply from an underground network often requires use of stud type connector. Consult your local utility. (BS2-TCV-KIT2U) -/4, -/2, 2 and 2- - TYPICAL BOTTOM 2-/4 in. /4 in. K.O. 2-3/6 in., -/4, -/2, 2 and 2- Qty. KIT BS2-TCV-KIT2U Kit Meter socket with PVC accessories Consists of BS2-TCV 200 A meter socket E943J 2 in. terminal adaptor E986J 2 in. LB access fitting E995J 2 in. meter offsets E997JC 2 in. clamps 2 UA9AJCB-CTN 2 in. elbow 90 degree CI76 2 in. nut 3 PH20 2 in. hub D8

BS2-TCVFA 200 A, 20/240; Single Phase Service Line: #6 AWG to 350 kcmil, Load 2 x #6 AWG 4/0 Tunnel type connectors for both load and line sides For underground and above ground service Designed and manufactured in Canada Primarily used in: All provinces Application: When distance is a factor larger conductors require larger connectors. -/32 in. 2 in..475 in. 2.5 in. 3.32 in. 27-7/6 in. Trade size K.O. -/4 in., -, 2 in., 2- Trade size K.O. 3-Places 0.6 in. in., -/4 in., -, 2 in., 2- Trade size K.O. s - 2-/4 in. /4 in. K.O. 5- Approved for copper and aluminum BS2-TCVFA Combination overhead and underground 200 A service 27-7/6 2 5-7/6 4 6.3 D9

BS2L Series 200 A 600 V; Oversize Enclosure Lay-In Lug Same as BS2 Series with the exception that lay-in type connectors are provided Conductor range: 6 AWG-250 kcmil Aluminum lay-in type connectors for both load and line sides For overhead, underground and combination overhead/underground Primarily used in: B.C., Ont. (BS2L-TV) -/4, -/2, 2 and 2-,, -/4, -/2, 2, 2-/2 and 3 in. - TYPICAL BOTTOM 2-/4 in. 4-3/6 in. 2-9/6 in. 4-3/4 in. -3/6 in. 9- /4 in. /4 in. BC HYDRO BOTTOM 2-3/6 in., -/4, -/2, 2 and 2- BS2L-V 200 A overhead with lay-in lugs BS2L-TV 200 A underground with lay-in lugs BS2L-TCV 200 A over/under combination with lay-in lugs BS2L-TCVBCR 200 A over/under combination with lay-in lugs (BC) BS2L-WTCV 200 A over/under combination water heater lugs BS2L-WTCVNY 200 A over/under combination with water heater lugs and North York assembly FACTORY INSTALLED ACCESSORIES Include: -5 5 th jaw standard capacity -6 5 th jaw full capacity, 6 o clock position -9 5 th jaw full capacity, 9 o clock position -IN Insulated neutral -NY North York assembly -W Water heater lugs 7-/8 2 5-7/6 6 7.2 D20

BS2M Series 200 A 600 V; Oversize Enclosure, Subfeed on Load Side Conductor range: Line: 6 AWG-250 kcmil, Load: 2-/0 AWG Aluminum tunnel type connector for line side For overhead service only Dual lug subfeed for load side Primarily used in: All provinces (BS2M-V) -/4, -/2, 2 and 2- - BOTTOM 2-/4 in. /4 in. 2-3/6 in. -/4, -/2, 2 and 2- BS2M-V Overhead, hub opening 7-/8 2 5-7/6 5 6.8 D2

BS4M 200 A 600 V; Oversize Enclosure, Subfeed on Load Side Conductor range: Line: 6 AWG-250 kcmil Load: 6-4/0 AWG Aluminum tunnel type connectors for both line and load sides For overhead service only Dual lug subfeed connectors for load side Primarily used in: Manitoba (BS4M-V) -/4, -/2, 2 and 2-2-/4 in. -9/6 in. - 3-3/6 in. 3-3/6 in. -/4, -/2, 2 and 2-2-3/6 in. BS4M-V Overhead hub opening 7 2 5-7/6 4.95 6.75 D22

MO2 Series 200 A 600 V; Underground Only Conductor Range: Line: Single studs to accommodate compression lugs 350 kcmil max. (supplied by utility), Load: 6 AWG-250 kcmil For underground service only Aluminum tunnel type connectors for load side, studs on line side Primarily used in: Sask., Man., Ont., Que. (MO2-V) 9-5/6 in. -/4, -/2, 2 and 2-, -/4, -/2, 2, 2-/2 and 3 in. 9-/8 in. - /4 in. 4-3/6 in. 4-3/4 in. 9- /4 in. MO2-VO BOTTOM MO2-V BOTTOM 2 in. 2-5/6 in. MO2-V Underground studs MO2-VO Underground studs for Ontario FACTORY-INSTALLED ACCESSORIES Include: -W Water heater lugs -M 2/0 AWG subfeed on load side 9-/8 2 9-5/6 8 8. D23

MO2 Series Kit 200 A 600 V; Underground Only with PVC Accessories Conductor range: Line: Single studs to accommodate compression lugs (supplied by utility), Load: 6 AWG-250 kcmil For underground service only Aluminum tunnel type connectors for load side Primarily used in: Ontario Only 5-9/6 in. (MO2-VO-KIT2U), -/4, -/2, 2, 2-/2 and 3 in. 9-/8 in. - MO2-VO BOTTOM /4 in. 2 in. 2-5/6 in. Qty. KIT MO2-VO-KIT2U Kit Meter socket with PVC accessories Consists of MO2-VO 200 A Meter Socket CI76 2 in. Locknut 3 E943J 2 in. Male Adaptor E977JC 2 in. Pipe Strap 2 E986J 2 in. Conduit Bodies LB Type E995J 2 in. Meter Offsets 2 UA9AJCB-UPC 2 in. 90 o Elbow D24

MO2 Series Kit 200 A 600 V; Underground Only with PVC Accessories Conductor range: Line: Single studs to accommodate compression lugs (supplied by utility), Load: 6 AWG-250 kcmil For underground service only Aluminum tunnel type connectors for load side, studs on line side Primarily used in: Quebec Only 5-9/6 in., -/4, -/2, 2, 2-/2 and 3 in. (MO2-V-KIT-/4U) 9-/8 in. 2-5/6 in. 2 in. 4-3/6 in. 4-3/4 in. 9- /4 in. MO2-V BOTTOM Qty. KIT MO2-V-KIT-/4U Meter socket with PVC accessories Consists of MO2-V 200 A Meter Socket CE942RL 3 in. PVC/DB2 Adaptor CI70 -/4 in. nut 2 CI724 3 in. nut CI-DUCT- Duct Seal E943G -/4 in. Male Adaptor 2 E943L 3 in. Male Adaptor E945L 3 in. Expansion Fitting E977GC -/4 in. Pipe Strap E977LC-CAR 3 in. Pipe Strap E986G -/4 in. Conduit Bodies LB Type UA9AGCB-UPC -/4 in. 90 o Elbow Qty. KIT MO2-V-KIT2U Meter socket with PVC accessories Consists of MO2-V 200 A Meter Socket CE942RL 3 in. PVC/DB2 Adaptor CI76 2 in. nut 2 CI724 3 in. nut CI-DUCT- Duct Seal E943J 2 in. Male Adaptor 2 E943L 3 in. Male Adaptor E945L 3 in. Expansion Fitting E977JC 2 in. Pipe Strap E977LC-CAR 3 in. Pipe Strap E986J 2 in. Conduit Bodies LB Type UA9AJCB-UPC 2 in. 90 o Elbow D25