LED Light Bar. Series LLB. Installation Instructions

Similar documents
LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

LED IMPORTANT SAFETY INSTRUCTIONS

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

HPNLS-HO. Installation Manual

SAVE THESE INSTRUCTIONS

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

PRIMUS I PRIMUS II. Primus - Downlight. Primus - Wall Wash SPEC SPEC. Trim Options

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

Installation Instructions for Monorail 2 Circuit 2 X 250 Watt Sloped Surface Mount Magnetic Transformer 120 Volt Input to 12 Volt Single Feed Output

PAGE Both power cords must be connected & powered to operate the E-TES 120.

INTEGRID TRACK (120V) SPECIFICATIONS

MASTERsine Inverter PXA Series Installation Guide

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

Operating Instructions

Installation Instructions

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

NICHE-HV. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

Installation Instructions

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Electric Range installation manual

HAZARDOUS LOCATION STREET LIGHT SLA SERIES INSTALLATION INSTRUCTIONS

INSTRUCTIONS. Power Panel. Installation Instructions

UES-LL End Termination Kit

Sconce INSTALLATION INSTRUCTIONS P B

Sconce INSTALLATION INSTRUCTIONS P C

LED Edge-Lit Flat Panels

Owner's/Installation Manual

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

INSTALLATION INSTRUCTION MANUAL

SAVE THESE INSTRUCTIONS!!

Operation/Installation Instructions

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Installation Instruction ALG Series LED Area Light Version: 3.1

High Bay Luminaire Series

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

LED IMPORTANT SAFETY INSTRUCTIONS

Table of Contents Next FLO-SAFE Manifold System Pre-Installation Kit Matrx Toll-Free: Technical Support: Fax: Rev.

Installation Manual. CS9300 Professional Series Landscape Lighting System

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

Sconce INSTALLATION INSTRUCTIONS P34024W

LED UFO High Bay with j-box Installation Instruction

LED IMPORTANT SAFETY INSTRUCTIONS

ERGO KIT TEK01 SERIES

Installation Instructions: Eco Linear High Bay

Predator Medium Floodlight Wet Location

Installing Your 220v J-POD Kit

SAFETY, OPERATION & MAINTENANCE MANUAL

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

SAVE THESE INSTRUCTIONS

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

2904 Power Supply Installation Instructions I-EA00041

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Technical Manual. DLM Module. This manual should remain with the unit.

C Power Connection Kit

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

BLACKBIRD WIRING MANUAL

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

Part No. PAFULAxxx. Figure 2

SloanLED THINLED. Constant Current. Installation Guide

Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

CFP-LED Contractor Select Flat Panel. Installation Instructions

Installation Instructions

NANO MIX. Installation Manual

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

Operations and Service Manual. X30208 Load Bank

Dry Contact Closure Interface

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

PCVS Series Control Valve Supervisory Switch

MaxLite StaxMax LED Flood Lights

CATENARY ACCESSORIES INSTRUCTIONS. Power Management. Quick Connect Voltage Separation Box AY-QCVSB. Sheet 5. Suspension Accessories

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

ELECTRO-MECH SCOREBOARD CO.

Installation Manual CS9100-LED. Professional Series Landscape Lighting System

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Sconce INSTALLATION INSTRUCTIONS P34025

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

RECESSED TRACK (120V) SPECIFICATIONS

A WORD ABOUT PROPER GROUNDING

SAFETY, OPERATION & MAINTENANCE MANUAL

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

install o IIVIPORTANT - Savethese -&WARNING - -&WARNING - This appliance must -&WARNING - Before beginning the Mode_s PB970, PB975

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

NT-300 Series Single Circuit Track System & Accessories

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

Installation Instructions: Read these instructions in its entirety before performing any installation work.

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

DL-FLEX (-UP, -UP-HO, -UP-ULTRA)

Transcription:

LED Light Bar Led linear LIGHTING System Series LLB Installation Instructions WARNING: Installation should be carried out by a professional electrician. Always turn off main power before installation. These products may present a possible shock or fire hazard if improperly installed. 1. Always turn off power prior to installation or replacement. 2. Risk of electrical shock. Do not allow any connection pin to touch any electrical conductors. 3. Do not press directly on the top of cover, as it may cause damage. 4. For indoor use only. Do not use this product in a potentially combustive environment or outdoors. 5. Only connect to adjacent units, 300W maximum. If pivot is not tight enough Then, adjust tightness with screw driver and tighten the set screw loosen Draw a reference line to ensure proper alignment of mounting brackets Connector 0417 Page 1

Direct Wire Juction Box Installation Instructions Important: This Direct Wire Junction Box is to be used only with Starfire Lighting LED Under Cabinet and LED Light Bar Series Fixtures. This Junction Box is designed to be wired using Non-Metallic Cable (NM) or Armored Cable (BX) supply wires. Important safety instructions: 1. Read all instructions before beginning installation. Safely store these instructions for future reference. 2. Do not use this Junction Box or the Jumper Cable to provide power to other products. 3. CAUTION: Do not exceed 5 AMPS maximum load. 4. For use with 120V 60Hz. power supply only. For interior dry location use only. 5. WARNING: DO NOT CONNECT THE JUNCTION BOX UNTIL THE FOLLOWING CONDITIONS HAVE BEEN MET: A. Mounting and wiring of Junction Box is complete. b. The Junction Box cover has been replaced and screws securely fastened. c. All fixtures connected to Junction Box have been mounted. d. All open electrical ports on Junction Box and connected fixtures have been covered with electrical port covers provided with fixture. 6. Warning: To prevent overheating do not install in small enclosed spaces. To prevent electrical shock do not install in wet environments. 7. Qualified electricians, in accordance with local electrical codes, should perform all installations. 8. This product is suitable for use in dimming circuits. For best results (between 5-100% lighting control) use Lutron DV600P, S600, DVCL-153P or Lutron CL type dimmers. 9. Always turn off electrical power to this product before servicing. 10. Do not operate this product if Flexible Cable Connector has been damaged. 11. Keep Flexible Cable Connector away from sources of heat and heated surfaces. 12. Do not operate this product in environments where aerosol sprays are being used or where oxygen is being administered. Direct wire junction box installation: 1. Turn off power to associated electrical circuit at electrical service panel. 2. Remove Junction Box cover screws and remove cover. Save screws and lockwashers. 3. Prepare Flat Non-Metallic Cable (NM) (2C+Ground) or Armored Cable (BX) by stripping conductor ends approximately 3/8. 4. For Installation using 1/2 Die-Cast Metallic Cable Clamp, (see Fig.1): Determine mounting orientation and remove one Side Knockout on desired side of Junction Box for electrical supply. and attach 1/2 to Junction Box as shown. Affix to electrical supply (BX or NM). NM Cable outer jacket must protude thru to adequately protect internal conductors. 5. Tighten locknut and clamping screw(s) on electrical connector fitting securely. 6. Push stripped ends of wires into hole in Push-in Wire Connectors (see WIRING DIAGRAM). Supply wires are typically color-coded: Hot-black, Neutral-white, Groundgreen or bare copper. Note that black supply wire goes into Connector with black wire and white goes into connector with white wire. Green goes into green wire. 7. Push excess electrical supply wire back into wall and locate Junction Box on mounting surface. Affix Junction Box to underside of cabinet with captive screws provided. Be careful not to drive screws all the way though the cabinet bottom. Use shorter screws if necessary. 8. Replace and secure wiring Junction Box cover with supplied screws. Make certain lockwashers are located beneath screw heads to properly ground cover. 9. Follow installation instructions provided with Under Cabinet and Light Bar fixtures. Mount fixture, and insert Flexible Cable Connector (sold separately) or In-line Connector (supplied with fixture) into appropriate Electrical Port of Direct Wire Junction Box. 10. Make sure that all fixtures connected to Junction Box have been properly installed and that all open Electrical Ports on the Module and fixtures are safely covered with Electrical Port Covers. 11. Restore circuit power at electrical service panel. Turn on Master switch on Junction Box and turn on switches on each individual fixture. Master Switch can be used to control all fixtures simultaneously or fixtures can be operated individually. 1213 Page 2

Direct Wire Juction Box Figure 1: Captive Screw Cap Lockwashers Junction Box Cover Screws Using two types of Supply Wires: (NM) or (BX) Cable (2C+Ground) Rocker Switch Junction Box Cover Flat Non-Metallic Cable (NM) Locknut Captive Screw Direct Wire Junction Box Side Knockouts Armored Cable (BX) Push-in Wire Connector Electrical Port Electrical Port Cover Electrical Port Cover Screw Power Cord (sold separately) (LUC-P7 & LLB-P7) Flexible Cable Connector (sold separately) Connect to Fixtures (LUC-F & LLB-F) Figure 2: WIRING DIAGRAM Armored Cable (BX) (This Port, not for use) Side Knockouts Locknut N H Push-in Wire Connectors H: Hot-black N: Neutral-white G: Ground-green or bare copper G LUC & LLB Series Fixtures Flexible Cable Connector (sold separately) Captive Screws Locknut Power Cord (sold separately) (LUC-P7 & LLB-P7) LUC & LLB Series Fixtures 1213 Page 3

Direct Wire Juction Box with Occupancy Sensor Installation Instructions 1213 Page 4

Direct Wire Juction Box with Occupancy Sensor Important: Always turn off main power before installation 1213 Page 5

Direct Wire Juction Box Occupancy Sensor Junction Box LUC-OC / LLB-OC Height: 1.5" (including occupancy sensor) 3.75" 8.125" Junction Box LUC-JB / LLB-JB Height: 1" 3.75" 6.375" Starfire Lighting, Inc. 7 Donna Drive, Wood-Ridge, NJ 07075 P: 201.438.9540 F: 201.438.9541 www.starfirelighting.com 1213 Page 6