The reason for higher electric bills

Similar documents
CHARGE TANK. Overview. Using The Charge Tank. User Guide

Working Principle of Power Saver as per Manufacture:

A device that measures the current in a circuit. It is always connected in SERIES to the device through which it is measuring current.

2. There are 2 types of batteries: wet cells and dry cells.

Conservation Voltage Reduction (CVR) for Electric Distribution Cooperatives

Build Your Own Electric Car Or Truck

Welcome to the SEI presentation on the basics of electricity

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

What Will You Learn From This Module?

electricity is encirclled with red colour. Total Unit consumed are 447 Units.

BASIC ELECTRICAL MEASUREMENTS By David Navone

Plan Ahead or Bust the Electric Budget

All you need to know: New automatic meter

Module: Mathematical Reasoning

Energy Management Through Peak Shaving and Demand Response: New Opportunities for Energy Savings at Manufacturing and Distribution Facilities

Citizens Advice financial capability

LETTER TO PARENTS SCIENCE NEWS. Dear Parents,

TED 5000 USER MANUAL

Mash Tun / RIMS Tube Controller

ELITE 625 With Dial Display Control

Biasing the Vintage Series (Nomad, BelAir, VT50, Vintage 33)

Electrical Principles & Technologies Topic 3.3-Measuring Energy Input and Output

Battery Beak User Manual

Measurement and Analysis of the Operation of a Single-Phase Induction Motor

Variable Speed Drive on a Die Casting Machine

Compound Gears Laboratory - Part 2

E-technics.2k Electric work and power page 1 out of 5. A storiette out of every day life

Comments and facts below in chronological order as testing progress. Added non Added resistive Total load Watt meter kwh resistive

Jaeshininformation Co., of Korea Distributor

Electrical power. Objectives. Assessment. Assessment. Equations. Physics terms 5/27/14

Smart meter Instructions

TWO TECHNOLOGIES, ONE SOLUTION

Overcurrent protection

SEAS-NVE: End to End Smart Metering Solution

Diesel-Driven Compressor Torque Pulse Measurement in a Transport Refrigeration Unit

Fourth Grade. Multiplication Review. Slide 1 / 146 Slide 2 / 146. Slide 3 / 146. Slide 4 / 146. Slide 5 / 146. Slide 6 / 146

Troubleshooting. CryoSmart 1 - CryoSmart 20

ECT Display Driver Installation for AP2 Module

Electricity. Teacher/Parent Notes.

Boosting the Starting Torque of Downsized SI Engines GT-Suite User s Conference 2002

Elite Pure Sine. DC To AC Power Inverters Convert 12V DC electricity into clean household-like power.

CS 430RC. Solid De-icer Controller Configuration and Set-up Manual

I ve had lots of requests recently for

The First Annual Municipal Electric Champion Awards

ELITE 600

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS

Science Olympiad Shock Value ~ Basic Circuits and Schematics

Power Quality and Smart Grid. Power Quality

Chapter 12. Formula EV3: a racing robot

How To Analyze and Understand Your Electric Bill

Peak Demand Saver plan. Unlocking solar s potential

Power Quality Luis Vargas Research Engineer 9/18/2008

What exactly are next-generation meters?

Western Canada BLRBAC Conference Selecting the Right Power Supply and Electrode for a Recovery Boiler ESP

On-Grid Battery Storage with Solar Power

PowerLink JC Series Torque Transducer User Manual

Physics 144 Chowdary How Things Work. Lab #5: Circuits

Upgrading Your Truck Scale? 4 Critical Points You Should Consider

Is Your Factory Power Source Corrupting Your Product Testing? September 2015 Author: Steve Boegle Engineering Group Leader, Behlman Electronics

Coriolis Density Error Compensating for Ambient Temperature Effects

XP800i POWER INVERTER OWNER S MANUAL

Circuits.

PVP Field Calibration and Accuracy of Torque Wrenches. Proceedings of ASME PVP ASME Pressure Vessel and Piping Conference PVP2011-

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

Smart Metering: A driver for creating energy efficiency for households

34.5 Electric Current: Ohm s Law OHM, OHM ON THE RANGE. Purpose. Required Equipment and Supplies. Discussion. Procedure

Case Study UAV Use on a Crash Scene Versus Total Station Sergeant Daniel Marek Nevada Highway Patrol

CHAPTER 6.3: CURRENT ELECTRICITY

2003 BMW 325xi 2.5L Straight 6 About 120K Miles; Looks Well Kept Multi Strike COP Ignition. History. Customer bought used about 3 months ago

How do I get the most out of my new smart energy display?

The Magic of Electric Flying or. Volts and Amps for Dummies By John Wheater

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

INTRODUCTION INTRODUCTION

The Solar Shuttle Solar Trailer

Rotary Diecutting Accuracy Is it the Die or the Diecutter? Clint Medlock, Stafford Cutting Dies, Inc., Indian Trail, NC, USA

Trading the Line. How to Use Trendlines to Spot Reversals and Ride Trends. ebook

FUN! Protected Under 18 U.S.C. 707

A direct current (DC) circuit. L 26 Electricity and Magnetism [4] Alternating Current (AC) Direct Current DC. AC power

Teacher s Guide: Safest Generation Ad Activity

HOW TO USE A MULTIMETER, PART 1: INTRODUCTION

How to use the Multirotor Motor Performance Data Charts

Field Verification and Data Analysis of High PV Penetration Impacts on Distribution Systems

Fourth Grade. Slide 1 / 146. Slide 2 / 146. Slide 3 / 146. Multiplication and Division Relationship. Table of Contents. Multiplication Review

Special resistors. Book page Syllabus

INVESTIGATION ONE: WHAT DOES A VOLTMETER DO? How Are Values of Circuit Variables Measured?

Single-Phase Meter Components

NOVATEK-ELECTRO LTD Research-and-Manufacture Company Voltage Stabilizer Legat-35

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

smartvar Dynamic VAR Compensator

Straight Talk. About the Smart Grid. Introduction

Alternate Fuels Testers TEST RESULTS from testing done on Saturday 5/6/06.

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

Addressing the API Licensing Fear Factor

Period 11 Activity Sheet Solutions: Electric Current

Light bulbs are almost burnt out

Considering Financial Choices with Community Solar Gardens in Xcel s Territory

212, 312 & 412 Vista Series Analog Panel Meter

The leader in clean electric transportation. Corporate Overview NASDAQ: ECTY April 20, 2011

How Off Grid Solar Works

Electricity All Around Us

Transcription:

The reason for higher electric bills William S. Bathgate, BS EE bill.bathgate@gmail.com 1

The new AMI electric meter block diagram The Switched Mode Power Supply, (SMPS) which injects high frequency Oscillations/Harmonics and High Voltage transients, the old type analog meter did not create these effects The ITRON Hall effect sensors, that Measure volts and Amps, these sensors send distorted measurements to the Metrology Computer as the result of added Oscillations/Harmonics and voltage Transients from the SMPS 2

What do these transients look like? (at my home) The RED lines are your normal 60 cycle (Hz) 120 volt power wires. (actual peak is 167 volts) The YELLOW lines are Transient volts (16 Volts)that are injected on to the power wires from the SMPS These are not normal and should not be there. So these volts are being added to the measured value of the meter, in this case We see about a 10% error that will be calculated. This was done with few appliances running except a refrigerator and a few lights on. The Heat was off. This transient increases as additional load is demanded 3

What do these transients look like? Transient Voltage 334 Volts Peak to Peak (120 Volts RMS) 16 Volts Peak to Peak I have personally seen transients as high as 60 Volts peak to peak 4

But wait, what about my cell charger, or other electronic devices, don t they do the same thing? The simple answer is NO The meter manufactures left out a very simple thing that is in all your other household devices, it is called an EMC filter. AN EMC filter looks like this diagram and picture: If the meter manufactures had added this type of filter it would have cost the meter manufacturers about $2.00 to add this to every meter power supply and all these voltage transients would have been prevented. So, all these people complaining about sudden higher than ever bills can be in part be attributed to the design of the SMPS and the overall meter architecture. 5

But Wait, I thought the new meters we more accurate? So to be accurate I must hit the bullseye 1 time, to be precise, I must hit the same target spot repeatedly. The AMI meters meet the ANSI standard for accuracy, but they only have to hit the reference measurement once to be declared accurate according to the ANSI Test. They do not have to be precise and repeat the same measurement, over and over. ANSI is an industry funded standards body, it is not independent government body as the NIST actually is. 6

Total Amps Why is the Bill Higher? It depends on how it is calculated Totalized versus Average of the Peaks Calculation 100 17 Readings @ 10 Amps = 170 Amps 95 2 readings @ 20 Amps = 40 Amps electric Motor Surge Amps 90 1 reading @30 Amps = 30 Amps 85 Total Amps = 240 Amps 80 240 Amps / 20 = 12.0 Amps average 75 Total Amps "Totalized Method" = 240 Amps 70 "Average of the Peaks Method" (10+20+20+40) =22.5 Amps *20 = 450 Amps Total 65 60 55 50 45 40 35 30 25 20 15 10 5 0 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00 Seconds The utilities will not likely reveal how they are doing this calculation, unless forced under court order, this method can be electronically changed at will by the utility with no transparency to the consumer Normal Base load 7

The example of a totalizing meter a gas pump A gasoline pump is a totalizing type of device, regardless of how fast you press the handle the meter on the pump registers only the amount total fluid dispensed. It is as if you put the gas in a bucket and then poured it in your tank. The meter reads the total volume of gas dispensed, there is no averaging of the rate at which you pumped the gas. Since I have managed a power measurement product using current sensors and hall effect sensors I can tell you that averaging electronic readings is prone to results that are wrong. In the ANSI testing there is no fluctuating load characteristics. It does vary in load but the load is very stable. The test is similar to using a very, very large Edison Light Bulb with no variation such as a refrigerator motor starting and stopping frequently, and other reactive type of loads such as your furnace fan. Now lets think of calculating the amount of gas dispensed based on how fast the gas is pumped over a window of time, irrespective of the total volume dispensed. On the next page the math is calculated, it is a very simplified example but illustrates how easy it is to calculate the wrong amount by using averages over time. The analog meters we had were true totalizing meters, the wheel and dials worked exactly like a gas pump does. 8

Totalizing versus Average of the Peaks Gas Pump Example Run the pump at the slowest setting at 1 Gallon a minute for 1 minute Stop pumping for 4 minutes Run the pump at a faster setting at 50 gallons a minutes for 5 minutes Stop pumping for 4 minutes Run the pump at the slowest setting at 1 Gallon a minute for 1 minute Averaging of the peaks 1 Rate of flow in Gallons per minute 50 Rate of flow in Gallons per minute 1 Rate of flow in Gallons per minute 17.33333 Average rate in Gallons per minute - 1+50+1 = 53 -- Rate of 53/3 samples = 17.33 Average per minute 15Sample window for computing the average in minutes 260 Total Amount of gas pumped via averaging the peaks = 17.33 gallons per minute x 15 Minutes = 260 total Total Volume - Totalizing Technique 1 Total volume for 1 minute 250 Total volume for 5 minutes 1 Total volume for 1 minute 252Total Volume in Gallons - there is no sample window, you could pump 252 gallons over a full hour and it would still total the same amount In this example you paid for an extra 8 gallons of gas based in averaging the peaks versus total amount pumped 9

Summary - The consumer is at the mercy of a computer calculation not in their control The consumer is at the total mercy of the utilities, the consumer has no tangible means to challenge an inaccurate reading, even the utility cannot confirm whether a meter is accurate, they do not have the equipment or personnel. The utilities and meter manufacturers have created and deployed a product that by design creates inaccuracies in measurements from harmonic distortion called voltage transients/harmonics. Transients/Harmonic distortions are well documented to create measurement inaccuracies in multiple studies, one of these is Applied Electrometric Technology AEMT conference of April 2014 G201 Analysis of Harmonic Distortion Effect on Deviation Measurement of Electric Energy in a kwh Meter. I learned this basic concept in my electrical engineering classes over 40 years ago. 10