One Solution You Can Trust!

Similar documents
Enhanced Vapor Recovery and In-Station Diagnostics. Presented by: Matthew Schuessler, N Cal Territory Mgr 1

Vapor Recovery Monitoring

Vapor Recovery Monitoring

Healy VP Troubleshooting Guide

SMART CONTROLLER I INSTALLATION GUIDE

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

VST Newsletter. Vapor Systems Technologies, Inc. A message from Glenn K. Walker President, VST. Inside this issue: Glenn K. Walker

Advanced Pumping Solutions. Safe, efficient, reliable performance

North Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-204-U. Relating to Certification of Vapor Recovery Systems

(Please type or use black ink)

Electronic Logging Device (ELD) Rule

Vapor Recovery Assist System

SUBARU STARLINK YOUR SUBARU CONNECTED Safety & Security OWNER S MANUAL. Love. It s what makes a Subaru, a Subaru. MY16StarlinkS&S_OMportrait.

Executive Order VR-205-B VST Phase II EVR System with Hirt Thermal Oxidizer. Exhibit 2 System Specifications

e-track Certified Driver Operating Manual

6. Tanks - Leak Detection. NCDENR Division of Waste Management Underground Storage Tank Section

The Next generation of Entry Level Fuel Management Solutions

TABLE OF CONTENTS YOUR MISTBOX S SERIAL NUMBER

HOS Enhancements in Preparation for ELD Omnitracs, LLC. All rights reserved.

FLEX PROBE INSTALLATION AND PROGRAMMING GUIDE

Franklin Fueling Systems

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

PowerChute TM Network Shutdown v3.1. User Guide. VMware

Test Date: 3/30/2018 Order Number: Dear Regulator, Enclosed are the results of recent testing performed at the following facility:

ELD DRIVER GUIDE June 21, 2018

Overview of an Underground Storage Tank Inspection

PURPOSE RESPONSIBILITY

Optional Chip and Pin with Tap and Go

TomTom WEBFLEET Contents. Let s drive business TM. Release note

New Amendment to Executive Orders VR-203-N & VR-204-N

Gallagher Vapour Recovery

ELD ELECTRONIC LOGGING DEVICES SUMMARY OF REGULATORY MANDATE RULE. Rev 1/27/17

H I - PA R A D I G M

Phase-Two Water Detector

There is a Certification menu option that indicates that the mobile APP, mobile device used were self-certified according to federal requirement.

3 Phase Smart Controller

HOS Mobile App Driver s Guide. pg 1

How to Design a Genset Fuel System With Gen Evo (Franklin) ATG

TLS-450PLUS Console Intelligent Pump Control

ANNUAL UST SYSTEM INSPECTION CHECKLIST

AXINET BATTERY MANAGEMENT SYSTEM. system for monitoring and controlling the performance of charger stations

Update on Enhanced Vapor Recovery (EVR) and In-Station Diagnostics (ISD) at Gasoline Dispensing Facilities

Installation Instructions & Users Manual

Manual No: Revision: B. CCVP Rain Shield. Installation Guide

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

GPI (Gas Pump Interface) with Cash Register Express - Integration Manual

PowerChute TM Network Shutdown v4.0. User Guide. VMware

QUICK INSTALLATION GUIDE

SentryGOLD Compact. for Bennett Electronic Dispenser INSTALLATION MANUAL. Fuel Management System

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Understanding the Colorado Annual Compliance Package. William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety

GILBARCO ENCORE 300 & 500 SERIES DISPENSER RETROFIT with VDC control valves for HEALY SYSTEMS, INC. MODEL VP1000 VAPOR RECOVERY ASSIST SYSTEM OUTLINE

Ignition Power Management

Underground Storage Tank. City of Burbank UST Owners & Operators

{ The uniflow Release Station }

Rand McNally Device Software. What s New (Version )

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

UNDERGROUND STORAGE TANK INSPECTION CHECKLIST

Setting up CoCard Credit Card / Debit Card Processing in Retail/Quick Service

ELD Compliant Driver Operating Manual

Introducing Uconnect Rewards via MSER!

Installation Instructions TRACKNET TN-4003/4004

DC400 Dispensing Cutoff System

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Fluid Monitoring Station

Using the Electronic Logging Device (ELD)

Monthly Walkthrough Inspections

MT-1 Tracer Meter. RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller E. Philadelphia St., Ontario CA

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

3126B Truck Engine 7AS13353-UP(SEBP ) - Document Structure. Media Number -RENR Publication Date -01/07/2010 Date Updated -29/07/2010

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

IST INTELLIGENT SUBMERSIBLE TURBINE

User Guide. PowerChute Network Shutdown v4.1 Standard D /2015

Technical Service Bulletin

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-209-A

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

SyncUP FLEET. Implementation Guide

NEVADA GOLD II ARROW INTERNATIONAL CAPITOL BINGO

New Tank Installations. Peter Rollo

Model H30 Operation Manual

QuickServer Industrial Protocol Gateway

ELD/AOBRD-Mode Comparison

General information about underground storage tank (UST) fueling systems in every day language.

PRODUCT PORTFOLIO. Electric Vehicle Infrastructure ABB Ability Connected Services

A Day in the Life of a Smart Campus

STP-DHI DISPENSER HOOK ISOLATION STP-DHI 120 Volt Hook STP-DHIB 240 Volt Hook

HYDROTRAK - HYDRANT PERMIT SCHEME. User Manual

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

INTELLITROL. scully. Scully s Intellitrol System. Intellitrol is a state of the art microprocessor based system that provides:

Vehicle Disabling Systems

GFX2000. Fuel Management System. User Guide

INTECH Micro 2300-RTD6

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015)

FIXED SPEED SUBMERGED TURBINE PUMPS STP

Quick Setup Guide. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate.

ValveLink SNAP-ON Application

Transcription:

Enhanced Vapor Recovery and In-Station Diagnostics One Company One Order One Phone Call One Solution You Can Trust! From the only company who can offer a complete solution!

VRM Vapor Recovery Monitoring (In-Station Diagnostics)

Vapor Recovery Monitoring Components TS-VFM Vapor Flow Meter

Vapor Recovery Monitoring Components TS-VPS Vapor Pressure Sensor Pressure Sensor Range +/- 8 wc

Vapor Recovery Monitoring Components VRM Software Option Installed on either

Vapor Recovery Monitoring Components TS-550 or TS-5000 Fuel Management System OR

Vapor Recovery Monitoring Components TS-EMS Environmental Monitoring System (Comes Standard with VRM Software (ISD), Touch Screen, Printer and All Communication Options)

VFM Installation One Vapor Flow Meter per Dispenser Installed Either Above or Below Vapor Shear Valve or above the vacuum pump outlet Measures Vapors Recovered During Dispensing

VPS Installation One Vapor Pressure Sensor per Site Installed in the Closest Dispenser to the Tanks Monitors the Pressure of the Entire Vapor Containment Space Pressure Range +/- 8 wc

VFM and VPS Typical Installation Vapor In Vapor Flow Meter Vapor Flow Meter Vapor Shear Valve Vapor Pressure Sensor Vapor Out

Console Installation VFM and VPS Wires All Gasoline Hook Signals Dispenser Interface Cable Dispenser Power Wires TS-EMS connects to existing ATG TS-550/5000 Connects to VFM, Probes, Sensors, Line Leak etc.

FMS / EMS Consoles Communicates with Flow Meter and Pressure Sensor Dispenser Interface Module (Internal) records liquid volume of each transaction Monitors efficiency of Healy Enhanced Vapor Recovery and Vapor Containment System LCD Touch Screen Display Notifies User of System abnormalities Controls Dispenser Power TS-550/5000 FMS can also perform all Tank, Line and Containment Monitoring

Interfacing with the Console Two different methods of interfacing with the console LCD Touchscreen Standard Web Browser

Security Multiple password protected access levels Passwords for each level are programmable Guest View ISD, Fuel Management, Alarm and Compliance Date User Limited Control Functions like Re-enabling Dispensers Admin Full Setup and Control ability

Security Multiple password protected access levels Passwords for each level are programmable Guest View ISD, Fuel Management, Alarm and Compliance Date User Limited Control Functions like starting Leak Tests, Reenable Dispensers Admin Full Setup and Control ability Attempting to enter a restricted area or function, will prompt for entry of the appropriate password

Start Up and Operability Testing Verify Proper V/L Reading at each Fueling Point Real Time V/L Readings

Start Up and Operability Testing Atmospheric Reference (Zero) check on Vapor Pressure Sensor

Start Up and Operability Testing Verify Proper V/L Reading at each Fueling Point Atmospheric Reference check on Vapor Pressure Sensor Verify Programming with Dispenser Shut Down Test

Generating Reports Reports Can be printed on the internal printer

Generating Reports Reports Can be printed on the internal printer Or Generated within the web browser and saved or printed from the PC

VRM Status Page Shows VFM and VPS status Displays Ullage Pressure of the Vapor Containment space Indicates testing status

VRM Status Page Shows Dispenser state and status Shows Vapor / Liquid (V/L) result from last dispense

VRM Daily Report Performance Indicators Vapor Containment Pressure Average V/L per Fueling Point Daily V/L Test Results

VRM Daily Report Vapor Containment Pressure Average V/L per Fueling Point Performance Indicators INCON Engineering Systems Franklin Fueling Systems 3760 Marsh Road Madison, WI 53718 608-838-8786 USA 12/20/2005 11:25:39 Daily ISD Report Last 30 Days Pressure: inh2o ISD Up Time 100% ISD Version: 1.0.0 12/20/2005 Pressure Max 0.26 Pressure Min -2.53 Pressure 75 th -0.77 Pressure 95 th -0.11 FP1 0.98 FP2 1.03 FP3 1.03 FP4 1.05 FP5 0.98 FP6 1.01 FP7 1.01 FP8 1.05 FP9 0.97 FP10 1.02 FP11 1.03 FP12 1.05

VRM Monthly Report Performance Indicators Monthly Requirements Operational Requirements

VRM Monthly Report VRM Events for the Month VRM Failures for the Month VRM Warnings for the Month

VRM Monthly Report INCON Engineering Systems Franklin Fueling Systems 3760 Marsh Road Madison, WI 53718 608-838-8786 USA 12/20/2005 11:25:39 Performance Indicators Monthly Requirements Operational Requirements VRM Monthly Report June 2007 STATISTICS Operation [%] 100 Pass [%] 100 OPERATION REQUIREMENTS Vapor Collect Method Assist A/L Low 0.95 A/L High 1.15 MONITORING REQUIREMENTS Dly Vapor Coll. A/L Low 0.24 High 2.01 Wkly Vapor Coll. A/L Low 0.71 High 1.44 Wkly Ullage Pressure Monitor High 1.30 wcg Mthy Ullage Pressure Mon High 0.30 wcg

VRM Monthly Report VRM Warnings for the Month VRM Failures for the Month VRM Events for the Month

Vapor Recovery Alarms Types Monitoring Alarms Example: Weekly Vapor Collection, Fueling Point 6 Component Alarms Example: VFM Missing, VFM 3

Vapor Recovery Monitoring Thresholds Vapor Collection Single affected dispenser shutdown Vapor Containment All dispensers shutdown *Tables are found on page 6 of IOM

Clearing an Alarm Must be done by trained technician and have Administrator rights Vapor Collection Alarm Must run a Manual A/L from Control Page

Clearing an Alarm Must be done by trained technician and have Administrator rights Vapor Collection Alarm Must run a Manual A/L from Control Page Vapor Containment Alarm Run Clear Monitoring from Control Page Records Technician Certification Number

Clearing an Alarm Must be done by trained technician and have Administrator rights Vapor Collection Alarm Must run a Manual A/L from Control Page Vapor Containment Alarm Run Clear Monitoring from Control Page Records Technician Certification Number Component Alarm Repair Communication or Replace Component or Module

Alarm Scenario Day 1 Healy ball valve was left closed after testing on Dispenser 2 or some other vapor blockage in the dispenser vapor piping No vapor being collected by vacuum pump or vapor flow meter VRM begins collecting V/L s with value of zero Midnight - system issues a Daily Vapor Collection WARNING and notifies the user via: Default - Audible Alarm, Warning LED Flashes Optional Print, Email or Fax, Notify SSA/GCA software Allowed to continue Dispensing Technician should be dispatched

If the problem is not resolved Alarm Scenario Day 2 Midnight - system issues a Daily Vapor Collection ALARM Audible Alarm, Alarm LED Flashes other optional user notification Only Dispenser 2 is disabled, the rest of the site continues to operate Dispenser should be bagged off and service dispatched Dispenser can be re-enabled by authorized personal with password access, if local regulations allow. Otherwise Technician performs inspection Ball valve is re-opened Technician runs Manual V/L test with passing results and clears the alarm Dispenser back in Service

Re-Enabling a Shutdown Dispenser Determine if local Regulations allow Need to have User Level Password Does not clear the alarm but allows dispensing again Dispenser will be disabled again at midnight if the problem is not resolved Select dispenser shown as Shutdown

Re-Enabling a Shutdown Dispenser Enter User level Password Select OK

Dispenser is re-enabled Re-Enabling a Shutdown Dispenser

TS-EMS Environmental Monitoring System Stand alone ISD system Existing ATGs do not need to be replaced or upgraded! Interfaces with existing Tank Gauge for tank ullage information used in Vapor Containment monitoring and testing Includes Vapor Recovery Monitoring software, LCD Touch Screen, Printer and all communication options

TS-EMS Advantages Existing ATG does not have to be replaced or upgraded Uses the same conduit as existing ATG dispenser sensors for VFM and VPS cables Easily upgraded in the future to full Fuel Management System The same advantages as the TS-550/5000 Web Access Email capabilities User Friendly touchscreen Interface Rules Engine I/O Abilities

FFS/INCON VRM Advantages Dispenser based disabling won t take down the whole site Web access for local and remote monitoring and troubleshooting Rules engine emails provide immediate notification User friendly icon based interface Scalable Open Architecture for future upgrades Complete Fuel Management System or EMS stand alone ISD System

Manuals and Support Vapor Recovery Monitoring Installation Operation and Maintenance Manual Included in EO and every Console Vapor Recovery Monitoring Quick Reference Guide Included with every Console TS-VPS Installation Guide With every Vapor Pressure Sensor TS-VFM Installation Guide With every Vapor Flow Meter VRM Troubleshooting and Alarm Identification Guide - Available on Franklin Fueling Systems Web Site All Manuals are posted on the Franklin Fueling Systems website at http://www.franklinfueling.com/service/fms_tech.asp Technical Support is available M-F 7am to 7pm CST by calling 1-800-984-6266 Local Area Factory Support Personnel are also available for assistance

Training Technicians will initially be trained in a classroom setting Certification will expire two years from the date of completion Re-certification can be completed online A list of certified tech will be posted on the FFS web site Technicians will receive a wallet size certification card indicating Certification Type Date of Training Expiration Date

Forward Thinking The INCON TS-5 Series is state of the art Fuel Management and Environmental Monitoring technology How will the regulations and your ATG requirements change over the next 5-10 years? The TS-5 design ensures system longevity and low cost future Upgrades and Enhancements with features like: The ability to do remote updates Easily Upgradeable Multi function modules Open Architecture design The ability to add modules or an Expansion Box XML interface