PRODUCT DESCRIPTION TECHNICAL DATA. Dimmable 0.1% - 100% Operating temperature - 30 C +45 C LED per meter 60 Pitch distance Cutting Length (C)

Similar documents
Applications. Accent Lighting Ambient Lighting Display Lighting Shelf Lighting. Electrical Properties

Applications. Shelf Lighting General Lighting Food Lighting Accent Lighting. Electrical Properties. Photometric Code. Typ.

Applications. Food Lighting Shelf Lighting Accent Lighting Ambient Lighting. Electrical Properties

Applications. General Lighting Office Lighting Food Lighting Accent Lighting. Electrical Properties

LEDtape 800 TW Tunable White K CRI>90

LED modules LED flexible. Module LLE FLEX G1 8mm EXC Modules LLE FLEX EXCITE

PHASED OUT. LED light engine / OLED LED compact. Module SLE G5 ART EXC Modules SLE EXCITE

LED light engine / OLED LED compact. Umodule SLE G4 FASHION EXC

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE , CLE CLASSIC Modules CLE

LED light engine / OLED LED compact

LED modules LED linear / area

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE CLASSIC / CLE CLASSIC Modules CLE

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

PHASED OUT. LED / OLED Light Engine LED linear / area. Umodule STARK LLE STARK LLE

LED light engine / OLED LED linear / area. Module STARK LLE PREMIUM Modules LLE

Uengine COOL door for integration uengine COOL

Adjustable Adjustable Large Adjustable Deep. Deep / Deep IP44 / Deep Adjustable Deep Gold Deep Black Gold. IP44 Square Square Adjustable / 1-2-3

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule STARK QLE CLASSIC EM umodule STARK QLE PHASED OUT. Ordering data.

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC EM STARK LLE

PHASED OUT. LED light engine / OLED LED compact. Umodule STARK DLE GEN2 CLASSIC STARK DLE

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK LLE umodule LLE ADVANCED

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC STARK LLE

LINEARLIGHT POWER FLEX LF06P2 TECHNICAL DATASHEET

LED light engine / OLED LED compact. Umodule EOS P214-4 umodule EOS

LED light engines LED linear / area

LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

Typ. CRI. SDCM Module P [W]

Tunable White LED linear / area. Module LLE G2 PREMIUM LLE PREMIUM

Duris E5 PowerFlex LED Strips 7.5mm LED Pitch

LED modules LED linear / area

LED light engines LED linear / area

LED light engines LED linear / area

U LED modules, converters and systems SIGNAGE. Uengine IMAGE SELECT

PrevaLED Linear Slim 3

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

PrevaLED Linear Value 2

Duris E5 PowerFlex LED Strips 7.5mm LED Pitch

PrevaLED Linear Slim 3

Datasheet. Oslon10 Cluster White. LED Solutions. ILR-ON10-xxxx-SC201-xx series. Product Overview. Applications. Technical Features:

LED light engines LED linear / area

LED light engines LED linear / area

Stanley 3J 1 PowerStar Whites

LED modules LED linear / area

OSLON SSL LED 480mm PowerLinear White

LINEARlight FLEX Diffuse 400 LFD400T / LFD400MT / LFD400S / LFD400MS

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

OSLON 9 PowerCluster IR

7 OSLON +80 PowerAnna PCB White

Tunable White LED linear / area

Dragon1 PowerStar Colours

PrevaLED Cube G2. Product family datasheet. Spot-, Down- and Wallmount Light Engines and Modules

PrevaLED Linear HV Ideal alternative to linear fluorescent lamp source Basic description

Emergency lighting units EM LED Light Engines. Module EM-ES 08/10/12 Mk2 EM LED linear / area

USP s. 30 mm BEND RADIUS

XOOCOVE IP40. The optimum lighting solution with special mounting accessories for a wide range of cove applications

Dragon 4 IR 12 PowerCluster

12 OSLON 80 SSL MiniFlood Whites

3 OSLON +80 PowerAnna PCB Colours

BUILT-IN LED LIGHTING MODULES

LED BUILT-IN MODULES. LUGA C 2016 HiCRI COB modules for lumen packages from 1500 to 4500 lm. LUGA C 2016 HiCRI 1500 LM TO 4500 LM.

TSLC 6 UV LED 24v Strips

OSLON PowerStar Colours

OSLONeye Powerstar LED Modules

VALUE Flex Protect 300

Description: RX-ALF28T Series Waterproof LED module, Ultra-Slim Light Box direct type light source - can be continuously

VMU048012LP8xxA 5.5 LP-LINEARHO DC MODULE, 480mA MAX CURRENT

OSLON Strip Colours

Experience bright and vivid colors

OSLON 80 1 Micro Colours

VMU080030LP8xxA 22 LP-LINEARHO DC MODULE, 800mA MAX CURRENT

WARNING. This product uses High Brightness LEDs. Direct viewing of the SMD LEDs at close range should be avoided. Keep product away from children.

VMU140055LP8xxC 46 LP-LINEARHO DC MODULE, 1400mA MAX CURRENT

Experience bright and vivid colors

Experience bright and vivid colors

VMU240095LP8xxA 44 LP-LINEARHO DC MODULE, 2400mA MAX CURRENT

UltraBright Industrial Series

Experience bright and vivid colors

240 Photo: Omri Amsalem

LED Driver Linear / area fixed output

Fortimo LED Line Gen3

High-density LED modules that sell

INSTALLATION INSTRUCTIONS

Experience bright and vivid colors

242 Photo: Omri Amsalem

Experience bright and vivid colors

TMU140055CL8xxA 44 LINEARHO DC MODULE, 1400mA MAX CURRENT

TMU125050CL8xxA 22 LINEARHO DC MODULE, 1250mA MAX CURRENT

T5 Watt-Miser Linear Fluorescent lamps

Its elegant and minimal-invasive mounting clips offer an easy installation as pendant or surface-mounted luminaire.

LED BUILT-IN MODULES. LED Module Easy 28 Industrial and Hospitality Lighting EASY 28 3,500 LM TO 14,000 LM EASY 28 INDUSTRIAL AND HOSPITALITY LIGHTING

VALUE Flex 300. Product family datasheet. LED modules for semi-professional applications

LED MODULES. Comfort COB Residential, Retail and Industrial Lighting COMFORT COB 500 LM TO 11,000 LM

Transcription:

1

A SMART TAPE FLEX PRODUCT DESCRIPTION Ready-to-connect flexible LED-strip with extremely high light output (more than 2000 lumen per meter) Ultra-High color rendering index CRI > 90 Industry leading efficiency up to 90 lumen per watt Supplied with constant voltage (24 VDC); integrated constant-current IC on the tape for homogeneous professional lighting applications Excellent white color consistency McAdams SDCM 3 Perfect for general lighting, e.g. slim linear profiles and luminaires Reflective white copper PCB for optimal system efficiency High quality adhesive 3M-tape on backside for easy mounting on clean surface or cooling profile Long lifetime: L70 = 50000 h Optimised for high resolution dimming 0.1% - 100% APPLICATION General Lighting Office Lighting TECHNICAL DATA Size (LxWxH) 4900 x 10 x 2 mm Voltage 24V DC Current 1000 ma/m Service life 50000 h Dimmable 0.1% - 100% Operating temperature - 30 C +45 C LED per meter 60 Pitch distance 16 mm Cutting Length (C) 98 mm Linear Lighting Indirect Lighting ORDERING DATA AND TECHNICAL DATA SMART TAPE FLEX Art. Nr. Type Colour [K] Luminous flux [lm/m] Voltage [V DC] Power [W/m] LTL-00015-V01 LEDtape 927 2000 HCRI 2700 1882 24 24 LTL-00016-V01 LEDtape 930 2000 HCRI 3000 2088 24 24 LTL-00017-V01 LEDtape 940 2000 HCRI 4000 2172 24 24 Notes: All values apply at ta=25 C, tc=65 C Tolerance range of illumination data: +/-10 % Exceeding the maximum operating voltage leads to an overload on the tape. This may result in a significant reduction in lifetime or even destruction of the tape. Tolerance range for the supply voltage 24V: +2V / -1V External cooling is required According to IEC 62717 2

COORDINATES AND TOLERANCES ACCORDING TO CIE 1931 2700 K 3000 K 2700K Centre 0,4630 0,4200 Photometrical Code: 927/ 349 3000K Centre 0,4300 0,4016 Photometrical Code: 930 / 349 4000 K 4000K Centre 0,3761 0,3740 The specified color coordinates are measured by a current impulse with nominal values of module after a settling time of 100 msec. The ambient temperature of the measurement is ta = 25 C. The measurement tolerance of the color coordinates are ± 0.01. Photometrical Code: 940 / 349 OPTICAL PROPERTIES - LIGHT DISTRIBUTION Radiance angle = 120 3

STANDARDS LIFETIME EN 55015:2006 + A1:2007 + A2:2009 EN 61000-3-2:2006 + A1:2009 + A2:2009 EN 61000-3-3:2008 EN 61547:2009 EN 62471:2008 IEC/PAS 627171 The temperature at tc reference point is crucial for the light output and life time of an LED-tape. For SMART TAPE FLEX a tc temperature of <65 C is recommended in order to achieve an optimum between heat sink requirements, light output and life time. Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. THERMAL BEHAVIOUR Operating temperature (operation, no defects) ta -30... +45 C Storage temperature ts -40... +85 C Tc max tc 85 C tc LED temperature in C Luminous flux in % Lifetime in h 80 60000 25 70 81000 50 132000 80 44000 45 70 64000 50 110000 80 32000 65 70 50000 50 91000 FAILURE FRACTION THERMAL DESIGN AND HEAT SINK The rated life of LED-products depends to a large extent on the temperature. An excellent thermal design for the LED-tape products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life time. However, if the permissible temperature limits are exceeded, the life of the LED-tape will be greatly reduced or the LED-tape may be destroyed. It is necessary to mount the LED-tape onto a heat sink, e.g. an aluminum profile. The size of the heat sink is largely depending on the ambient temperature (ta) of the application. The following tables should be seen as a guide to a recommended heat sink depending on different ta: Ambient Temperature (Ta) Reference Temperature (Tc) Cooling Area (cm2) Thermal Resistance Recommended Profile (RthHS-A) 25 C 65 C 250 2,5 K/W Z200-2, Z201-2, Z22W-2 30 C 65 C 300 2,1 K/W Z200-2, Z201-2, Z22W-2 35 C 65 C 350 1,8 K/W Z22W-2 45 C 65 C 450 1,7 K/W Z22W-2 The failure fraction (Fy) corresponds to the rated life of the LED. The percentage (y) of a number of LEDs of the same type at their rated life designates the percentage (fraction) of failures. This failure fraction expresses the combined effect of all components of the LED-tape including mechanical, as far as the light output is concerned. The effect of the LED could either be less light than claimed or no light at all. Type Unit Rated Life Failure Fraction (Fy) LEDtape HCRI CONVERTER 1 meter L70 = 50000h (tc =65 C) Output voltage 24 VDC +10 % Power converter 5% (0.1% per 1000h of operations) = sum of the typical individual power of connected LED tape segments + 20% Selection of the operating device/protective functions The operating device protects the modules against overvoltage, overcurrent, overload and short circuits. The device must comply with the relevant standards for safe operation in all recommended applications and also in freezer and refrigeration equipment. Power supply units must ensure the following protective measures: SELV Short-circuit protection Overload protection Overtemperature protection 4

MOUNTING INSTRUCTIONS - MECHANICAL Never bend the LED-tape at a radius smaller than 50 mm. Assembly must not damage or destroy conducting paths on the circuit board. The LED module itself and all its components must not be mechanically stressed. The fixing/cooling surface must be properly cleaned to remove grease, dirt and silicon before application, e.g. using Isopropyl alcohol. When fixing the LED-tape to a surface, apply an even but gentle pressure and try to avoid applying pressure directly on the LED itself (the maximum allowed pressure is 20 N/cm²). After assembly always check that the entire length of the tape has attached properly to the surface and that there is no air pockets underneath the PCB. The thermal length expansion coefficient of the PCB is 17*10^-6cm/cm/K. When installing in environments with large variations in temperature (e.g. outdoor applications) and operating length of more than 2 m, the use of metallic mounting surfaces is necessary. Otherwise it is advisable to use an additional thicker adhesive tape to absorb the stress of any mismatch in expansion coefficients, e.g. 3M 9119-140 mic. MOUNTING INSTRUCTIONS - CUTTING The LED-tape is separable at every 6 LEDs or multiple thereof with the full function of each LED segment. It is only allowed to cut the LED-tape at the indicated cutting line. Cutting lenght (C) is 98 mm. C C MOUNTING INSTRUCTIONS - SOLDERING Without heat sink Pre-tin the cables only Soldering temperature max 300 C during 4 seconds With heat sink Pre-tin solder pads and cables Soldering temperature max 350 C during 3 seconds MOUNTING INSTRUCTIONS - WIRING Each reel of LED-tape is delivered with color coded connection cable L=350mm, 2x0,5 mm2. Do not connect more than 10 meters of the LED-tape in series. When connecting several sections in parallel please refer to the table Driver & Control Systems for the allowed total length connected to one controller/dimmer. max 10 m in series Converter Colour Red Black Function + - MOUNTING INSTRUCTIONS - ELECTRICAL CONNECTION In order to drive LUMITECH LED-tapes safely, it is absolutely necessary to operate them with an electronically stabilized power supply protecting against short circuits, overload and overheating. Always use our approved drivers and controls to power the LEDtape refer to Driver & Control Systems. If the wrong type of driver is used the product warranty is void. Electronic control gear for LED should carry the CE mark and ENEC certified. In Europe the declarations of conformity must include the following standards: CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384. Also check for the mark of an independent authorized certification institute. 5