CAST RESIN TRANSFORMERS

Similar documents
YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

Distribution transformers Efficiency over life-cycle

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

Key features. DESIGNS: - Conservator type - Hermetically sealed

Prime Power Energie Systems Inc.

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

with Vacuum Circuit Breaker HAF

Design specifications

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

HPS EnduraCoil. Cast Resin Transformer

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Cast resin transformers

AIR CORE REACTORS. Phoenix Electric Corporation

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

INESING GROUP. Power System Solution

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

The construction features of EdM transformers

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Bushings for High Voltage AC Applications

MEDIUM POWER TRANSFORMER

Kuhlman Electric Corporation Volt Instrument Transformers

NXPLUS C Single busbar. Maintenance-free for lifetime

Transformer Bushing Type EKTO

EMPAC Metal enclosed capacitor bank for wind applications

Chapter 6 Generator-Voltage System

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

Oil Circuit Breakers

C. System Design and Performance Requirements

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Unit Substation Transformers 5 and 15 KV Class

TRANSFORMERS UP TO 750 kv

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

ABB Transformers Egypt

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

ABB Ltd. FACTORY IN HANOI

Section S7 - DC and AC auxiliary services installations

UniGear. Technical Guide

www. ElectricalPartManuals. com r" n;;-==- Westinghouse Ventilated Dry Type Transpac Power Centers Page 1 Descriptive Bulletin

BUSBAR SOLUTIONS TECHNOLOGY FOR ELECTRICAL ENERGY

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

TGK Prefabricated Substation Technical Data

OLIVER ONLINE VOLTAGE REGULATION

Unified requirements for systems with voltages above 1 kv up to 15 kv

MCset kv Medium voltage equipment

DRY TYPE TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency

Technical Specification for Pole Mounted Capacitor Rack

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

CAST RESIN TRANSFORMERS

*(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

GAS INSULATED VOLTAGE TRANSFORMERS.

Double earth fault in a PSP during back to back launching sequence

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

Transformer Installation, Operation, and Maintenance Manual

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

HVW701 HVAC Drive with By-Pass

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

siemens.com/energy/transformers GEAFOL Cast-Resin Transformers Operating Instructions

Padmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage

Unitole UP kv Primary substations Motor control centres

CP Automatic capacitor bank

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A

Transformers Global product offering

MVSS. Technical features

Terminations. 3M Cold Shrink Terminations FAX TERMINATIONS. Glossary of Terminations Terms 263 Cable Types for Terminating 264 3M

Chapter 4 Ignition & Electrical Systems

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Company Overview. REV 2018, April

High voltage in motion Environmentally friendly circuit breakers and economic long-rod insulators

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

Kuhlman Electric Corporation Volt Instrument Transformers

Transcription:

MODEL TAM CAST RESIN - TAM TYPE Epoxy cast resin dry-type transformers are recommended to operate in places that require security, the materials used in its construction are hard to combust and are self-extinguishable in case of a fire, they don t explode or release toxic gases. Its installation is considerably more economic than its similar mineral oil-immersed versions, because they dispense with fire-proof masonry whereas retention tanks for liquid collection still occupy smaller spaces. They can be installed in mobile machines/devices, thus making use of a lesser volume of low tension conductors and reducing the tension shortage with the loss of energy dissipated by the cables. They re practically maintenance-free and are not affected by humidity. The constructive type assures a high mechanical resistance to short circuits, and a low level of noise as well. They offer high fault resistance and, by means of forced ventilation, they can increase the nominal capacity of up to 40%. They present a low level of partial discharges (practically exempt). They don t offer any kind of environmental restrictions. They are appropriate for indoor installations in subways, railroads, airports, nuclear and industrial installations, hospitals, laboratories, movie theaters, residential and commercial buildings, shopping malls, etc. 1 / 8

DETAILS OF THE CONSTRUCTION The cores are built with grain-oriented silicon-iron sheets and assembled in a steplap. The windings are made of electrolytic aluminum with a purity superior to 99.5%, with the low tension made by sheets of axial dimension to the end coil with F class insulation and high tension with aluminum strips and it is cast in epoxy resin under an F class high vacuum. High Vacuum Encapsulation System For the transformer s protection system, it uses a digital temperature indicator wired to a sensor inserted into the low tension winding. This indicator is provided by relay contacts to alarm, disconnection and activation of the forced ventilation system. These transformers are manufactured with a degree of IP00 protection and they can be optionally provided with a metallic IP20 cabinet or superior. Standards: NBR 10295 TYPICAL CHARACTERISTICS: Power: 75; 112.5; 150; 225; 300; 500; 750; 1000; 1500; 2000; 2500; 3000; 5000; 7500; 10.000 and 15.000 kva, other power ratings upon request Classes of stress: 7.2; 15; 24.2 and 36.2 kv Basic impulse level of the class: 15 kv : 95 kv and 110 kv Terminals for connection of the AT/BT terminals Grounding terminals REGULAR ACCESSORIES: Suspension means for the active part and the casing, when applicable Bi-directional wheels OPTIONAL ACCESSORIES: Forced ventilation system Protection Cubicle Electrostatic Armor Disconnecting Bushings Protection system and thermal monitoring of the windings 2 / 8

DIFFERENT FEATURES UPON REQUEST: Ratings, tensions, temperature class and special applications. TESTS: The routine trials that are conducted on all production units are the following: a. Electric resistance of the windings; b. Stress/Strain relationships; c. Insulation resistance; d. Polarity; e. Angular displacement and sequence of stages; f. Losses (empty and charge); g. Chain of excitation; h. Short-circuit impedance; i. Dielectric tests; - Nominal supportable stress to the industrial frequency (applied stress); - Induced stress; j. Checking of the functions of the accessories; 3 / 8

IP-00 1 - A.T. Terminal 2 - B.T. Terminal 3 - Neutral 4 Lug for suspension 5 - Posts of the temperature sensor 6 Derivation panel 7 Traction lug 8 Grounding terminal 9 - Bi-directional wheels 10 Identification plate ACCESSORIES INCLUDED Bi-directional smooth wheels Traction holes Temperature sensor Grounding Connector OPTIONAL ACCESSORIES Electrostatic Armor AT and BT connectors Bushings AT 15 kv plug-in type Forced ventilation IP20 Circuit Breaker Box Digital temperature indicator with contacts Wheels for rail DIMENSIONS AND APPROXIMATE WEIGHT High Tension up to 15kV and Low Tension shorter than 4000 A Power Ratings Length. Width Distance of Wheels Height Weight kva L - mm W - mm D - mm H - mm kg 300 1300 820 630 1450 1190 500 1470 850 650 1590 1580 750 1490 850 650 1780 1850 1000 1600 1000 820 1850 2350 1500 1780 1100 900 1900 3100 2000 1900 1250 1000 2100 4100 2500 1950 1250 1000 2180 5000 3000 2050 1360 1100 2300 5900 4 / 8

IP-20 1 Lug for lifting/suspension of the complete transformer 2 - B.T. Output Terminal - Mater.: Aluminum 3 - A.T. Output Terminal - Mater.: Copper 4 Neutral Terminal - Mater.: Aluminum 5 Traction lug 6 Grounding terminals 7 Access to derivation panel 8 Bi-directional wheels 9 Identification plate 10 Ventilation air ducts 11 - B.T. Flange 12 - A.T. Flange 13 - A.T. Wall Bushing - Mater.: Epoxy 14 Case with temperature thermometer ACCESSORIES INCLUDED Bi-directional smooth wheels Traction holes Temperature sensor Grounding Connector OPTIONAL ACCESSORIES Electrostatic Armor AT and BT connectors Bushings AT 15 kv plug-in type Forced ventilation IP20 Circuit Breaker Box Digital temperature indicator with contacts Wheels for rail DIMENSIONS AND APPROXIMATE WEIGHT High Tension up to 15kV and Low Tension less than 4000 A Ratings Length. Width Wheel Distance Height Weight kva L - mm W - mm D - mm H - mm kg 300 1700 1000 630 1870 1400 500 1850 1100 650 2000 1900 750 1900 1200 650 2150 2250 1000 2000 1300 820 2200 2800 1500 2180 1300 900 2300 3650 2000 2300 1400 1000 2500 4700 2500 2400 1400 1000 2600 5700 3000 2500 1600 1100 2750 6700 5 / 8

2 nd NUMERAL CHARACTERISTIC: DEGREE OF PROTECTION AGAINST PENETRATION OF WATER WITH HARMFUL EFFECTS 0 1 2 3 4 5 8 1 st NUMERAL CHARACTERISTIC: DEGREE OF PROTECTION AGAINST UNIDENTIFIED SOLID OBJECTS Non-protected against water drops falling vertically against water drops falling vertically when the case is angled up to 15º against water spraying against water projection against water jets against the effects of continuous immersion in water Non-protected 0 IP-00 IP-01 IP-02 -- -- -- -- against unidentified solid objects from Ø 50 mm and larger 1 IP-10 IP-11 IP-12 IP-13 -- -- -- against unidentified solid objects from Ø 12.5 mm and larger 2 IP-20 IP-21 IP-22 IP-23 -- -- -- against unidentified solid objects from Ø 2.5 mm and larger 3 IP-30 IP-31 IP-32 IP-33 IP-34 -- -- against unidentified solid objects from Ø 1 mm and larger 4 IP-40 IP-41 IP-42 IP-43 IP-44 IP-45 -- against deposits of dust inside the equipment 5 IP-50 IP-51 IP-52 IP-53 IP-54 IP-55 -- Absolute protection against penetration of dust in the equipment 6 IP-60 IP-61 IP-62 IP-63 IP-64 IP-65 -- 6 / 8

MININUM EXTERNAL SPACING FOR DRY-TYPE Class of Equipment Stress (kv) Effective Class of Atmospheric Impulse (kv) Minimum Spacing PHASE- GROUND (mm) Minimum Spacing PHASE-PHASE (mm) 0.6 -- 25 25 1.2 -- 25 25 7.2 40 45 60 60 65 90 15 95 130 160 110 150 200 24.2 125 170 220 150 200 280 150 200 280 36.2 170 240 320 200 300 380 7 / 8

INSTALLATION They dispense with explosion-proof and fire-resistant walls, the transformers and their cables must be installed considering the minimum distances required and expected in the standards according to the class of stress. VENTILATION In order to project the ventilation of the room where the transformer was installed, it s important to take its total losses into consideration, which are expressed in the form of heat, which in turn increases the room temperature, which must be sufficiently spacious to allow the exit of hot air, in most cases it is possible to adopt a simple solution with one air entrance. Cold in the lower part and a hot air exit in the upper part, according to the following scheme, the use of filters is recommended in order to limit the entrance of dust. Obs.: for further information and details, it s necessary to refer to the installation manual that comes with the transformer. 8 / 8