TPC. User Manual. LED 70N Cordless LED Curing Light

Similar documents
TPC. User Manual LED 55N. Cordless LED Curing Light. All instructions in this USER S MANUAL must be completely read before installation or operation.

ART-L5 LED CURING LIGHT. Directions for Use

Slimax LED Curing Light System

! Installation,!Operation!&!User!Manual!!

1. D-Lux Introduction ENGLISH Parts & Components Product Overview. 4. Precautions. 5. Hand-piece Components Installation

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Endodontic Handpiece (GT) USER MANUAL

This user manual prvides the operation, regular maintenance and safety information. Read this user manual carefully before you use

Lucent Operatory Dental Light

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-500 Mini-Electric Portable Dental System

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

CURING LIGHT LED.B USER S MANUAL

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

EQUIPMENT Operation Manual

VALO Cordless Curing Light

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual

EQUIPMENT Operation Manual

Uninterruptible Power System

G2 Portable oxygen concentrator User Manual

Robotic Vacuum Cleaner. User Manual

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

400 Watt Backup Power System Owner s Manual

BlueFin User's Manual. Version 1.1

INSTRUCTION MANUAL. Tel / Fax SOM-S056S-KE Rev.5

Cordless Endodontic Handpiece. Manual Revision Date: July 2005 OPERATION MANUAL

Instructions For Use VATEA. Endodontic Irrigation Device

c-go 24V/6A 24V/8A 24V/12A

B-RAD Select USER MANUAL TABLE OF CONTENTS

AquaLift Bath Lift System MODEL #8100

AFE8B BATTERY POWERED CRIMP TOOL

OPERATION and MAINTENANCE INSTRUCTION MANUAL

ME310B BATTERY POWERED CRIMP TOOL

FOR YOUR PERMANENT FILE

Installation and Operation Manual Back-UPS BX1100CI-CN

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

OPERATING INSTRUCTIONS

ILLUMINATING EYE MASSAGER

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

TABLE OF CONTENTS. Introduction

STP116 STP188. Tyre Pressure Monitoring System. User manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

Four-Position Gang Charger for SAFEMTX Li-ION Battery Packs

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

AC/DC Powered Peak Detection Fast Charger for 4- to 8-Cell Ni-Cd & Ni-MH Batteries

Electrostatic Fieldmeter

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Fiber Identifier. Fiber Identifier is a tool necessary for the maintenance of optical fibers, used

SURGICAL POWER & ACCESSORIES. Rx Only PM-X00-710/PM-X IR-12.13

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

HXE4B BATTERY POWERED CRIMP TOOL

Wireless Tire Pressure and Temperature Monitoring System Color Display Manual. Wide Screen Color Display Model #: TST-507-D-C

101 Stair Lift SR601 OWNER'S MANUAL. Dealer Name & Contact Information: Serial # of Your Lift: Install Date:

FOR YOUR PERMANENT FILE

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

YSmart Technology Co., Ltd. User Manual. GTI Grid Series. GTI Series Inverters for Grid-connected PV system

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

Rave by We-Vibe. Control with your smartphone and get more features with the We-Connect app. we-vibe.com/app. Internal/ G-spot stimulator

Owner s Manual and Warranty Information

OPERATING MANUAL PLS HVR 505

Stair Lift SL600 OWNER'S MANUAL. Dealer Name & Contact Information: Serial # of Your Lift: Install Date:

OPERATING MANUAL PLS HVR 505 PACIFIC LASER SYSTEM S. The Professional Standard

Power Inverter 400 MW Owner s Manual

CONTENTS. User Safety 2 Introduction and CX440 Accessories 3 CX440 Diagram 4 CX440 Keypad and Remote Control 5 Operating Instructions 6

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

LIBERATOR USER MANUAL

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

Please activate my limited warranty for WAGAN Corp.

Installation and Operation Back-UPS BX550CI-CN

BoostPak2 Instruction Manual

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

EBS PRODUCTS

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

OPERATING MANUAL PLS HLE 1000 PACIFIC LASER SYSTEMS. The Professional Standard

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

XeVision XeRay XV-LX50 HID Searchlight

(42001) Neck Massager / Masseur de cou User Manual / Manuel de l utilisateur

OPERATIONS MANUAL MODEL MT-500

Instruction Manual Recharging Aids and Dock

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

9 VOLT ALKALINE. not included

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

HDE36B BATTERY POWERED CRIMP TOOL

EBS PRODUCTS

Setting New Standards through Innovation FUSION INSTRUCTIONS FOR USE. Ortho LED Curing Light System (Rev 4) Powered by Patented Focus Beam Technology

USER MANUAL BRUSHLESS SPEED CONTROLLER S5-RTR ESC S5A-RTR ESC RC CARS & TRUCKS

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

LET S ROLL. 1. Power button/led 2. Battery level LEDs 3. Bluetooth button/led 4. USB-C 5. USB 2 6. USB 1 7. DC in 8. AC outlet

REMOTE CONTROLLED DOG TRAINING COLLARS

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Installation & Operation Manual Chef Base

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Dip Tester Model DS-03

Matson Jump Starter Operator s Manual

Transcription:

TPC User Manual LED 70N Cordless LED Curing Light LED70 must be installed and operated by a qualified dental professional. All instructions in this USER S MANUAL must be completely read before installation or operation. The user should wear colored protective glasses to avoid eye injury by the led light.

Table Of Contents 1. INTRODUCTION 1 1.1 TECHNICAL INFORMATION 1 2. FEATURES 2 3. ACCESSORIES 3 4. INSTALLATION 3-4 5. OPERATION 4-5 6. MAINTENANCE 6 8. WARRANTY 7 9. TROUBLESHOOTING 7

1.INTRODUCTION Thank you for purchasing the LED 70N curing light. The LED 70N is a dental curing light which uses the latest LED technology to polymerize composite resin Caution Attention: Important information is being presented. Refer to the Operator s Manual for more informa tion. High intensity Light: Protect your eyes from the light generated by this product Shock Hazard: Beware of electrical shock or injury. Type B Applied Part Class II Medical Equipment Electronics Waste: Properly dispose of when use is discontinued. 1.1 Technical Information Range of Light (in nm) 430-490 nm Light Intensity at the Tip (mw/cm2) 2,000 mw Battery Life 200 cycles at STANDARD mode, 10 seconds per cycle; 135 cycles at STANDARD mode, 20 seconds per cycle. Charging Time to Complete 5 Hours Battery Type Lithium Ion 7.4V dc 2500mAh Cradle Battery Rechargeable Operating Temperature 15-30 C (60-86 F); Unit turns off automatically when the temperature at the wand tip reaches 48 C Power Input, Curing Light 9.0 VDC @ 2.4 A Power Input, Power Supply 100-240 VAC @ 50-60 Hz Pulse Rate 10 Hz Pulse Duty Cycle 50% Storage and Transport Conditions 0-40 C (32-104 F) 0-100% RH -1000 to + 9000 meters elevation 1

2.FEATURES 1. Latest LED technology. 2. Low heat output. 3. Easy operating with LCD Display. 4. Three preset programs FAST : Full power output all time. PULSE : 0.5 second interval after full power output for RAMP : Gradually increasing output in first half curing cycle, then Full power output till end. Light Intensity (mw/cm 2 ) F : FAST Light Intensity (mw/cm 2 ) P : PULSE Light Intensity (mw/cm 2 ) S : STEP Time (sec) 2.0 Time (sec) 0.5 Time (sec) 0.25 Follow the manufacturer s instruction to adjust the curing time for better curing performance. 5. Timer: Five preset curing time from 5, 10, 20, 30, and 40 seconds. 6. Low Battery Signal When is blinking on the LCD Display or there is a triple beep tone alarmed every 20 seconds, the battery needs to be charged for at least 4 hours. 7. Sleeping Mode If the LED 70N is unused for a period of 3 minutes the curing light will convert to Sleep Mode to conserve the battery. 8. Auto Memory LED 70N will remain in previous settings. Including the curing time and the curing program. 9. Cord/Cordless Interchangeable The LED 70N may be operated directly using AC power supply connected to the base of the handpiece. This will allow users to operate the curing light while simultaneously charging the battery. 10. Build-in LCD Radiometer User can monitor LED output by reading the radiometer which is located on the charging base. 2

3. Accessories 1. Curing Light Handpiece 2. Charging Base 3. Oval Protector 4. Light guide 5. Switching Power Adapter 6. Funchion Switch 7. Curing Switch 4. Installation Step 1: Remove the battery cover located on the side of the handpiece. Connect the battery terminals and install the side cover. Step 2: Connect the power adaptor to the charging base. Step 3 : Directly insert the Light Guide into the curing light handpiece. Verify it has been completely inserted into handpiece. Light guide may be rotated to achieve best angle on tooth structure. 3

4. Installation Step 4 : Install the eye Protector. Step 5: Charge Lithium battery For the best performance. Charge curing light handpiece continuously for 4 hours (charge battery at least 8 hours prior to initial use). The battery symbol on the LCD panel will show the sign of full power when battery is completely charged. A flashing battery symbol indicates the battery should be recharged or user can directly connect it to the power supply for uninterupted use. LED 70N will detect the charging automatically. There will be one short beep tone generated when it has been properly put on to the Charging Base. 5. Operation A. Set Curing Program Press and hold the function switch for two seconds and you will see the modes change every second. To stop on the desired mode simply let go of the depressed button for the selected mode. (1) FAST (2) PULSE (3) RAMP 1.Curing Time 2.Battery Sign 3.Curing Program Indications on LCD Panel Fast Mode Options. 1. 2,000 mw 2. 1,500 mw 3. 1,000 mw To select a specific output in the fast mode press and hold the curing switch for two seconds to change to the desired output mode. 4

B. Set Timer Press function switch to select curing time between 5, 10, 20, 30, and 40 seconds. When choosing PULSE or RAMP, the curing time will start at 10 seconds automatically. C. Start to Operate Press curing switch to begin curing program. To interrupt a program, just press curing switch again. When the curing program is complete the curing light handpiece will beep and then turn off the light immediately. D. Wake Up from Sleeping Mode The curing light will turn into sleeping mode automatically when it is no longer in using for 3 minutes. Press function switch or curing switch once to activate curing light. E. Low Battery Sign When the is blinking, the curing light handpiece should be recharged immediately or directly connected to the power sypply for continued use. F. Turn off the Power The curing light handpiece will achieve sleeping mode automatically. This will shut down all the curing function to save the power. User may de-activate curing light by disconnecting the battery terminals from the battery. G. Radiometer Place the light guide against the detective spot on the radiometer. The meter will measure the intensity of LED curing light and display the intensity on the LCD display. The output reading from the radiometer is a reference for the user to adjust to appropriate curing time. The radiometer is designed to test LED output only. 5

6. MAINTENANCE 1. Be sure there is no resin or material sticking to the surface of the light guide. 2. If materials are sticking on the light guide immediately clean it with soft cloth. Keep light guide clean for better light intensity and curing performance. 3. The light guide should be sterilized after each use. It can be safely autoclaved at 121 C. For no more then 15 minutes. Let cool before handling. 4. The other accessories such as curing light hadpiece and eye protector should be scrubbed with pure water and sheathed in accordance with standard disinfection procedures. 5. Keep curing light handpiece in charging station while not in use. 6. Dispose Lithium battery according to the federal and state laws. 7. The User should wear colored protection glasses to avoid eyes injury due to LED light. Warranty Information All of our products sold are guaranteed to be free from defects in workmanship and materials for a 1 year from date of purchase, unless otherwise stated. TPC will repair or replace any defective part at no charge. During the warranty period. TPC will not be responsible for labor charges or shipping charges to / from the TPC facility. This guarantee does not cover normal wear or stains on surface finish. The guarantee does not cover damage resulting from improper installation or misuse. All claims against the freight carrier must be initiated at the time the damaged items are received. The claim is the responsibility of the customer. We are improving our products on a continuous basis. We reserve the right to make modifications without the need for prior notification and are not obligated to modify previously manufactured items. Light guides and batteries are not covered under any type of warranty. 6

7. Trouble Shooting Fault Possible Cause Solution Display is not functioning on the curing light Battery drained. Charge Battery Connect to power supply When i press the function button the mode does not change Button Is stuck Veryify the button depresses in and pops back out. When i use the light it over heats Fan not functioning Send to TPC for service Battery drains very quickly Battery is near end of life Charge battery Verify charging cycle is complete Replace battery Temporarly use with power supply The light does not functon after Battery is exhausted Replace battery charging but it will function when the power supply is attached to the bottom of the light. There is no light emitting from the Damaged LED Send to TPC for service light but the display functions. When i place the curing light on the charging base the battery does not charge Light not seated in base correctly Dirty Contacts Battery is exhausted Reseat light in charging base Clean Contacts Repalce battery Light intensity is reading low Light guide does not fit properly in the end of the curing light light guide is dirty or damaged Battery is low LED is burning out O-ring is damaged Clean / repalce light guide Charge battery Return to TPC for service Repalce O-ring Warranty Card Name: Address: City: State: Zip Phone Number:( ) - FAX:( ) - Email Address Model: LED 70N Handpiece: SN Base: SN Please complete this card and return it to TPC. Include a copy of your invoice or packing slip. Return to: TPC Advanced Technology 851 S. Lawson St City Of Industry, CA 91748 Or Email a scaned copy to service@tpcdental.com 7