Ditec VALOR Sliding doors automation (Original instructions)

Similar documents
Ditec BOX Balanced up and over doors

Ditec LUXO Swing gates automation (Original instruction)

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

Ditec VALOR HH-HS IP2063EN. Technical manual Sliding doors automation for hospitals and heavy sliding doors (Translation of the original instructions)

Ditec CUBIC Swing gates automation

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

Ditec DOD Industrial sectional door automations

Ditec SPRINT Swing doors drive unit

Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions)

Ditec CROSS18-19 Sliding gates automation. IP1984 EN Technical Manual. (original instructions)

Ditec PWR50H/HV/HR Automation for swing gates

Ditec PWR25H/35H Automation for hinged gates

Entrematic Ditec Sprint 24V

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

Ditec SPRINT Automation for swing doors

Rex. Manuale di installazione e manutenzione per porte scorrevoli. Installation and maintenance manual for sliding door

IP2160EN. Ditec NeoS / NeoS+ Sliding Gates. Technical Manual. (Original instructions)

QIK4E-QIK7EH. Installation and maintenance manual for electromechanical barrier. (Translation of the original instructions) IP1861EN- rev.

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio.

USER INSTRUCTIONS FOR SLIDING DOORS

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

INSTRUCTIONS FOR INSTALLATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Cross14, Cross14E, Cross14VE, Cross15V

Ditec E1A. IP2045EN Technical manual. Control panel installation manual for one motor automation with built-in radio.

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

Typical Installation Schematic

DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH. Maximum door weight = 40kg per leaf total system 80kg

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio.

EC DECLARATION OF CONFORMITY

BULL 424 ESA BULL 624 ESA

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Ditec automatic pedestrian sliding doors.

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Automation Swing Gate Opener

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Installation Manual. Swing Gate System. Leading the way...

Maximum Weight = 80 kg for 2 doors; Maximum door width = 1100mm (to suit up to maximum 2120mm clear opening) Quick Start. 5 & 4mm Allen keys.

BISON 20 OM BISON 25 OTI

SLIDE NEW CONTROL BOARD

Automatic concealed bollards 275 H600 and 275 H800 Control station

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

Quick Start. Flat head screwdriver. Wheel carriage x 2. M8 Nut x 2. Strap Bolt x 2. 1 x 2m Anodised Track

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

FORCE SPD 800/1500/2000

Ditec Valor HS and Ditec Valor HH Automatic pedestrian doors for controlled atmosphere environments

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

24 V ENCODER SAFE VERSATILE SETTING. Ditec Qik Automatic barriers for passages up to 7.6 m.

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Ditec Valor H Automatic pedestrian doors for controlled atmosphere environments

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Cross Automations for sliding gates

Porte 150 Users Manual Swing Gate Opener 24V DC

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

INDEX CE DECLARATION OF CONFORMITY FOR MACHINES... 2 WARNINGS FOR THE INSTALLER DESCRIPTION AND TECHNICAL SPECIFICATIONS...

Max. stand-by power without accessories Use frequency 100% Max leaf width Motor Motor powered at 36V with encoder Max.

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Automatic concealed bollards 275 H600 and 275 H800 with pit

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

E R A I GATE AUTOMATION DIVISION

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL

CE DECLARATION OF MACHINE CONFORMITY

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

Mod: KLD6-12/35XLAS-N

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

ENG. Exeo. Revolving pedestrian door

Volo, Onda. Advanced entrance technology. Automation for curved sliding doors ENG

Ditec PWR Automation system for swing gates with wings up to 5 metres

BELT CONVEYOR PNL/4 Series User and maintenance manual

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

Battery Charger JCB-FCH20LI2

BELT CONVEYOR CB/M5 Series

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

OPERATING AND USERS MANUAL

Ditec Alimax Rapid door for the food sector.

Compact System NRGS 11-2 NRGS Original Installation Instructions English

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Battery Charger JCB- SCH20LI.2

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Sectional and Tilting Door Opener

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

BARRY BARRIER GATE AUTOMATION

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Index. 4 DESCRIPTION... p. 5 5 PRELIMINARY CHECKS... p. 5 6 ASSEMBLY... p. 6

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

Operators for sliding doors

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

MP V 8A Electronic Smart Charger. Instruction and Information Manual

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

Transcription:

Ditec VALOR Sliding doors automation (Original instructions) IP1950 EN Technical manual www.entrematic.com

Index Subject Page 1. General safety precautions 3 2. Declaration of incorporation of partly completed machinery 4 2.1 Machinery directive 4 3. Technical data 5 3.1 Applications 5 4. Standard installation 6 5. Installation of the automation 7 5.1 VALOR box fastening 7 5.2 VALOR T box fastening 8 5.3 VALOR H box fastening 9 5.4 Preparation of glass door wing 11 5.5 VALOR - VALOR H door wing installation and adjustment 12 5.6 VALOR T door wing installation and adjustment 13 5.7 Floor guide installation 15 5.8 Belt adjustment 16 5.9 Lock installation 16 6. Electrical connections 17 7. Ordinary maintenance program 18 User instructions 19 General safety precautions 19 Manual release instruction 21 Function selector user instructions 22 Key i This symbol indicates instructions or notes regarding safety, to which special attention must be paid. This symbol indicates useful information for the correct functioning of the product. 2

1. General safety precautions Failure to observe the information in this manual may result in minor personal injury or damage to equipment. Save these instructions for future reference. This installation manual is intended for qualified personnel only. Installation, electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with the present standards. Read the instructions carefully before installing the product. Bad installation could be dangerous. The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of children, as these are a potential source of danger. Before installing the product, make sure it is in perfect condition. Do not install the product in explosive areas and atmospheres: the presence of inflammable gas or fumes represents a serious safety hazard. Before installing the motorisation device, make all the necessary structural modifications in order to create safety clearance and to guard or isolate all the crushing, shearing, trapping and general hazardous areas. Make sure the existing structure is up to standard in terms of strength and stability. The motorisation device manufacturer is not responsible for failure to observe Good Working Methods when building the frames to be motorised or for any deformation during use. The safety devices (photocells, safety edges, emergency stops, etc.) must be installed taking into account: applicable laws and directives, Good Working Methods, installation premises, system operating logic and the forces developed by the motorised door. The safety devices must protect the crushing, cutting, trapping and general hazardous areas of the motorised door. Display the signs required by law to identify hazardous areas. Each installation must bear a visible indication of the data identifying the motorised door. When requested, connect the motorised door to an effective earthing system that complies with current safety standards. During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the electrical parts. The automation protection casing must be removed by qualified personnel only. The electronic parts must be handled using earthed antistatic conductive arms. The manufacturer of the motorisation declines all responsibility in the event of component parts being fitted that are not compatible with the safe and correct operation. Use original spare parts only for repairs or replacements of products. The installer must supply all information on automatic, manual and emergency operation of the motorised door and must provide the user with the operating instructions. 3

2. Declaration of incorporation of partly completed machinery (Directive 2006/42/EC, Annex II-B) The manufacturer Entrematic Group AB with headquarters in Lodjursgatan 10, SE-261 44 Landskrona, Sweden declares that the automation system for Ditec VALOR sliding doors: - has been constructed to be installed on a manual door to construct a machine pursuant to the Directive 2006/42/EC. The manufacturer of the motorized door shall declare conformity pursuant to the Directive 2006/42/EC (annex II-A), prior to the machine being put into service; - conforms to applicable essential safety requirements indicated in annex I, chapter 1 of the Directive 2006/42/EC; - conforms to the Low Voltage Directive 2006/95/EC; - conforms to the Electromagnetic Compatibility Directive 2004/108/EC; - technical documentation conforms to Annex VII-B to the Directive 2006/42/EC; - technical documentation is managed by Marco Pietro Zini with offices in Via Mons. Banfi, 3-21042 Caronno Pertusella (VA) - ITALY; - a copy of technical documentation will be provided to national competent authorities, following a suitably justified request. Landskrona, 15-01-2013 Marco Pietro Zini (President) 2.1 Machinery Directive Pursuant to Machinery Directive (2006/42/EC) the installer who motorizes a door or gate has the same obligations as the manufacturer of machinery and as such must: - prepare the technical file which must contain the documents indicated in Annex V of the Machinery Directive; (The technical file must be kept and placed at the disposal of competent national authorities for at least ten years from the date of manufacture of the motorized door); - draw up the EC Declaration of Conformity in accordance with Annex II-A of the Machinery Directive and deliver it to the customer; - affix the EC marking on the motorized door in accordance with point 1.7.3 of Annex I of the Machinery Directive. 4

3. Technical data Ditec VALOR L-H Ditec VALOR P Ditec VALOR N Ditec VALOR T Power supply 230 V~ 50/60 Hz 230 V~ 50/60 Hz 230 V~ 50/60 Hz 230 V~ 50/60 Hz Power fuse F1A F1A F1,6A with weight >200 kg F1A F1,6A with weight >200 kg Rated power input 200 W 300 W 300 W 300 W Max speed 1 wing 0,8 m/s 0,8 m/s 0,8 m/s - Max speed 2 wings 1,6 m/s 1,6 m/s 1,2 m/s with weight 180 kg 1,6 m/s 1,2 m/s with weight 180 kg F1A F1,6 A with weight >200 kg 0,8 m/s Max speed 4 wings - - - 1,6 m/s Service life 5 - HEAVY DUTY 6 - CONTINUOUS 6 - CONTINUOUS 6 - CONTINUOUS Intermittence S3=100% S3=100% S3=100% S3=100% Max door weight 1 wing 120 kg 100 kg 100 kg 1 breakout 120 kg 200 kg door wing Max door weight 2 wings 220 kg 180 kg 180 kg 2 breakout 240 kg 260 kg door wings Door weight with reinforced wheels 1 wing - - 150 kg - Door weight with reinforced wheels 2 wings - - 300 kg - Temperature -20 C - +55 C -20 C - +55 C -20 C - +55 C -20 C - +55 C Temperature with batteries -10 C - +50 C -10 C - +50 C -10 C - +50 C -10 C - +50 C Degree of protection IP20 (FOR INTERNAL USE ONLY) IP20 (FOR INTERNAL USE ONLY) IP20 (FOR INTERNAL USE ONLY) IP20 (FOR INTERNAL USE ONLY) Control panel EL20 EL20 EL20 EL20 Accessories power supply 24 V 0,5 A 24 V 0,5 A 24 V 0,5 A 24 V 0,5 A 3.1 Operating instructions Service class: 5 (minimum 5 years of working life with 600 cycles per day). Applications: VERY INTENSE (for shared entrances with very intense pedestrian use). Service class: 6 (minimum 5 years of working life with continuous use). Applications: CONTINUOUS (for all special situations with continuous use). - Performance characteristics are to be understood as referring to the recommended weight (approx. 2/3 of maximum permissible weight). A reduction in performance is to be expected when the access is made to operate at the maximum permissible weight. - Service class, running times, and the number of consecutive cycles are to be taken as merely indicative having been statistically determined under average operating conditions, and are therefore not necessarily applicable to specific conditions of use. During given time spans product performance characteristics will be such as not to require any special maintenance. - The actual performance characteristics of each automatic access may be affected by independent variables such as friction, balancing and environmental factors, all of which may substantially alter the performance characteristics of the automatic access or curtail its working life or parts thereof (including the automatic devices themselves). When setting up, specific local conditions must be duly borne in mind and the installation adapted accordingly for ensuring maximum durability and trouble-free operation. 5

GND 4. Standard installation 6B a 5 6B 6A 4 2 1 3 0 A b 7 11 7 12 8 10 9 Ref. Code Description 0 VALOR Operator 1 Drive unit 2 EL20 Control panel 3 AL2 Transformer 4 VALABE VALABC PAS024AMW (microwave+infrared), or 5 PASAA2 (only infrared) PAS024AMW (microwave+infrared), or 6A PASAA2 (infrared only) or PASM24W (microwave), or PASM243 (microwave), or 6B PASS24 (microwave), or PASS24W (microwave), or PASA (infrared) PASAT3 7 PASAT3I 8 VALSB LOKSBM } + PASAT3I (infrared) Emergency batteries (optional) No-break batteries (optional) Combined sensor for opening and safety during closing external side Combined sensor for opening and safety during closing internal side (operator) Opening sensor (a) + Safety during closing sensor (b) internal side (inside the operator s housing) Safety during opening sensor (outside or inside the operator s housing) Integrated release handle Release handle 9 COME - COMHK Functions selector switch 10 CELPR Photocells (NOT ACCORDING TO STANDARD EN 16005) 11 MD1 Display 12 PFP1 - PFP2 - PDP1 - PDP2 Open push buttons A Connect the power supply to an approved omnipolar switch with an opening distance of the contacts of at least 3mm (not supplied). The connection to the mains must be made via an independent channel, separated from the connections to command and safety devices. 6

5. Installation of the automation 5.1 VALOR box fastening 175 +/- 8 +/- 6 28 90 38 145 27 80 70 max H 10 HM = H + 18 0KP515AB Wiring passage Unless otherwise specified, all measurements are expressed in millimetres (mm). The VALOR automation wall fixing measurements are illustrated in the diagram, considering that the door wing profiles are not of our production. If the door wings are made with DITEC profiles of the PAM series: refer to the measurements in the related manuals. WARNING: if the door wings are fitted with a break-out device, use the carriages with brackets with 3 fixing points. Fix the box with M6 Ø12 steel plugs or 6MA screws. Distribute the fixing points approx. every 800 mm. Make sure that the box is level and its top surface is perpendicular with the floor and not deformed lengthwise with the shape of the wall. If the wall is not straight and smooth, the box must be fixed to metal plates. WARNING: The fastening of the box to the wall must be suitable in order to sustain the weight of the door wings. i The given operating and performance features can only be guaranteed with the use of DITEC accessories and safety devices. 7

5.2 VALOR T box fastening 255 90 38 +/- 8 145 27 +/- 6 +/- 6 160 70 max 70 max H 28 KPAM45 KPAM45 12 HM=H+16 Wiring passage Unless otherwise specified, all measurements are expressed in millimetres (mm). The figure shows the measurements for wall mounting the VALOR H automation considering that the door wings are made of DITEC PAMH60 series profiles. If the PAMH60 door wing has lead-shielding (e.g. radiology department) refer to the measurements marked [*]. Fix the box with M6 Ø12 steel plugs or 6MA screws. Distribute the fixing points approx. every 800 mm. Make sure that the box is level and its top surface is perpendicular with the floor and not deformed lengthwise with the shape of the wall. If the wall is not straight and smooth, the box must be fixed to metal plates. WARNING: The fastening of the box to the wall must be suitable in order to sustain the weight of the door wings. 8

5.3 VALOR H box fastening 90 38 175-8 +27 PAMH60 VALH60 Wiring passage 170 15 10 60 HM=H-8 HM=H+60* 12 8* H 50 PH=H-34 34 *114 6 6 9

34 L 74 min 80 max 600 PL=L-68 10 10 30 57 116* LM=L+46 (LM=L+164)* 57 116* 39 Unless otherwise specified, all measurements are expressed in millimetres (mm). The figure shows the measurements for wall mounting the VALOR H automation considering that the door wings are made of DITEC PAMH60 series profiles. If the PAMH60 door wing has lead-shielding (e.g. radiology department) refer to the measurements marked [*]. Fix the box with M6 Ø12 steel plugs or 6MA screws. Distribute the fixing points approx. every 800 mm. Make sure that the box is level and its top surface is perpendicular with the floor and not deformed lengthwise with the shape of the wall. If the wall is not straight and smooth, the box must be fixed to metal plates. WARNING: The fastening of the box to the wall must be suitable in order to sustain the weight of the door wings. 10

5.4 Preparation of the glass door wing The diagram indicates the process measurements of the aluminium profile AC1356 and glass. Ø10 through holes are required on the aluminium profile and Ø15 on the glass for fastening. The number of holes and related distance between centres are based on the door wing width. Silicon should ideally be used between the edge of the glass and the internal base of the profile. Ø10 Ø10 Ø10 11 100 L 1000 100 11 100 100 100 100 L>1000 100 100 100 100 100 100 10 30 30 100 Ø15 L 1000 100 30 30 Ø15 Ø15 L>1000 100 100 100 100 Ø15 Ø15 Ø15 L 1000 L>1000 12 i With AC4255 or AC4870 glass wing attachment applications, see the respective manual. 11

5.5 VALOR - VALOR H wings installation and adjustment Make sure that the central wheel [d] is adjusted as illustrated in the diagram. Fix the door wing to the carriage with screws [a]. The outer wheel of the carriage must not protrude beyond the dimension of the door wing. Adjust the horizontal position of the door wing in accordance with the measurements indicated in diagram VALOR 2 for 2 door wing automations, VALOR 1 RH for right-hand opening automations and VALOR 1 LH for left-hand opening automations. Secure the adjustment with screws [a]. Loosen screws [b], adjust the vertical position of the door wing by means of screw [c] and fix the adjustment with screws [b]. Check, by moving the door manually, that the movement is free and without friction and that al the wheels rest on the guide. WARNING: Leave a gap of at least 10 mm between the glass door wings when closed to avoid contact of the glass. max 0,5 mm d c d b a b VALOR 2 WINGS 150 150 150 150 OPEN OPEN LM VALOR 1 WING - RIGHT OPENING LM 200 OPEN 150 LM VALOR 1 WING - LEFT OPENING 150 OPEN LM 200 12

5.6 VALOR T wings installation and adjustment Make sure that the central wheel [d] is adjusted as illustrated in the diagram. Fix the door wing to the carriage with screws [a]. The outer wheel of the carriage must not protrude beyond the dimension of the door wing. Adjust the horizontal position of the door wing in accordance with the measurements indicated in diagram VALOR 2 +2 for four door wing automations, VALOR 1 +1 RH for right-hand opening automations and VALOR 1 +1 LH for left-hand opening automations. Secure the adjustment with screws [a]. Loosen screws [b], adjust the vertical position of the door wing by means of screw [c] and fix the adjustment with screws [b]. Check, by moving the door manually, that the movement is free and without friction and that al the wheels rest on the guide. Proceed as follows to adjust the overlap of the door wings: - Place the door in the closed position. - Hold the external door wing in the closed position. - Loosen [g] and move the door wing, increasing or decreasing the overlap. - Tighten [g]. Adjust the tension of the cables by means of adjuster [e], loosening the locking nut. Correctly tension the cable, then block it with the locking nut. c d max 0,5 mm max 0,5 mm b a b g f e f g 3 mm f e 13

VALOR 2+2 WINGS 150 100 150 150 150 150 100 150 S S OPEN OPEN OPEN OPEN LM LM LM LM d e f f e d VALOR 1+1 WING - RIGHT OPENING 200 150 100 150 OPEN S OPEN LM LM f e d VALOR 1+1 WING - LEFT OPENING 150 100 150 200 OPEN S OPEN LM d e f LM 14

5.7 Floor guide installation The floor guides must be made of an antifriction material such as PVC, NYLON, TEFLON. The length of the floor guide should not be greater than the overlap of between the fixed and mobile door wing and must not enter the doorway. The measurements of the code 0KP515AB floor guide for framed door wings are indicated in the diagram. 10 22 10 HM min 21 max 40 50 The measurements of the code KPAM45 floor guide for telescopic door wings are indicated in the diagram. 12 19 12 5 HM 50 42 42 The floor guide for the PAMH60 door wing has the measurements indicated in paragraph 5.3. The measurements of the code 0KP369 floor guide for glass door wings are indicated in the diagram. 10-12 25 5 40 10 HVM 50 15

5.8 Belt adjustment Loosen screws [a], unscrew screw [b] until the spring is at a compression of 22 mm (if the length of the automation is lower than 2600 mm) or 20 mm (if the length of the automation is greater than 2600 mm). Block the adjustment by tightening screws [a]. WARNING: incorrect adjustment impairs the correct functioning of the automation. b a 5.9 Lock device installation LT<2600 = 22 mm LT 2600 = 20 mm Place the door wing in the closure position. Fasten the lock device to the box profile by means of the supplied screws [a]. Align the lock pin [b] and the lock bracket [c] and manually check the correct functioning. Slightly lubricate the lock pin and lock bracket. c b c b a a 16

6. Electrical connections Electrical wiring and starting are shown in the installation manual of control panel EL20. Make sure the yellow/green conductor is at least 30 mm longer than the brown and blue conductors. Before connecting the power supply, make sure the plate data correspond to that of the mains power supply. An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the mains supply. Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a suitable overcurrent cutout. Use a H05RN-F 3G1,5 or H05RR-F 3G1,5 type electric cable and connect to the terminals L (brown), N (blue), (yellow/green) in the automation. Make sure the yellow/green conductor is at least 30 mm longer than the brown and blue conductors. Secure the cable using the special cable clamp and remove the outer sheath near the terminal only. Connection to the mains power supply, in the section outside the automation, is made with independent channels and separated from the connections to the control and safety devices. The channels must penetrate a few centimetres inside the automation thorough a hole maximum Ø16 mm. Make sure there are no sharp edges that may damage the power supply cable. Make sure that the mains power supply (230 V) conductors and the accessory power supply (24 V) conductors are separate. 17

7. Routine maintenance plan Perform the following operations and checks every 6 months according to intensity of use of the automation. Without 230 V~ power supply and batteries: - Clean and lubricate the moving parts (the carriage guides and the floor guides). - Check the belt tension. - Clean sensors and photocells. - Check the stability of the automatic system and make sure that all screws are correctly tightened. - Check the alignment of the doors, the closing positions and the correct introduction of the blocking device. Connect the 230 V~ power supply and batteries: - Check that the blocking system is working correctly. - Check the stability of the door and that the movement is regular and without friction. - Check that all command functions are operating correctly. - Check the correct functioning of the photocells. - Check that the door s developed powers are in accordance with applicable regulations. i NOTE: for spare parts, see the spares price list. i For repairs or replacements of products only original spare parts must be used. The installer shall provide all information relating to automatic, manual and emergency operation of the motorised door or gate, and provide the user with operating instructions. The installer must prepare the maintenance log, which will indicate all the interventions of ordinary and extraordinary maintenance carried out. 18

Ditec VALOR VALOR user s manual user s manual Sliding door automation Sliding door automation DETACH AND DELIVER TO THE CUSTOMER General safety precautions The following precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully since they contain important information on safe installation, use and maintenance. These instructions must be kept and forwarded to all possible future users of the system. This product must only be used for the specific purpose for which it was designed. Any other use is to be considered improper and therefore dangerous. The manufacturer cannot be held responsible for any damage caused by improper, incorrect or unreasonable use. This product should not be used by people (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instructions concerning the use of the appliance by a person responsible for their safety. Avoid operating in the proximity of the hinges or moving mechanical parts. Do not enter within the operating range of the motorized door while it is moving. Do not block the movement of the motorized door since this may be dangerous. Do not allow children to play or stay within the operating range of the motorized door. Keep remote controls and/or any other control devices out of the reach of children in order to avoid possible involuntary activation of the motorized door. In the event of fault or malfunctioning of the product, turn off the power supply switch, do not attempt to repair or intervene directly and contact only qualified personnel. Failure to comply with the above may cause a dangerous situation. All cleaning, maintenance or repair work must be carried out by qualified personnel. To ensure that the system works efficiently and correctly, the manufacturer s indications must be complied with and routine maintenance of the motorized door must be performed by qualified personnel. In particular, regular checks are recommended in order to verify that the safety devices are operating correctly. All installation, maintenance and repair work must be documented and made available to the user. For the correct disposal of electric and electronic equipment, waste batteries and accumulators, the user must take such products to the designated municipal collection facilities. 19

Technical data Ditec VALOR L-H Ditec VALOR P Ditec VALOR N Ditec VALOR T Power supply 230 V~ 50/60 Hz 230 V~ 50/60 Hz 230 V~ 50/60 Hz 230 V~ 50/60 Hz Power fuse F1A F1A F1,6A with weight >200 kg F1A F1,6A with weight >200 kg F1A F1,6 A with weight >200 kg Rated power input 200 W 300 W 300 W 300 W Service life 5 - HEAVY DUTY 6 - CONTINUOUS 6 - CONTINUOUS 6 - CONTINUOUS Temperature -20 C - +55 C -20 C - +55 C -20 C - +55 C -20 C - +55 C Temperature with batteries -10 C - +50 C -10 C - +50 C -10 C - +50 C -10 C - +50 C Degree of protection IP20 (FOR INTERNAL USE ONLY) IP20 (FOR INTERNAL USE ONLY) IP20 (FOR INTERNAL USE ONLY) IP20 (FOR INTERNAL USE ONLY) Control panel EL20 EL20 EL20 EL20 Accessories power supply 24 V 0,5 A 24 V 0,5 A 24 V 0,5 A 24 V 0,5 A The following safety devices may be installed to protect the danger areas (according to EN 16005): 2B 3 3 1 2A DETACH AND DELIVER TO THE CUSTOMER 1 PAS024AMW (microwave+infrared), or PASAA2 (infrared only) Combined sensor for opening and safety during closing external side 2A PAS024AMW (microwave+infrared), or PASAA2 (infrared only) Combined sensor for opening and safety during closing internal side (operator) or 2B 3 PASM24W (microwave), or PASM243 (microwave), or PASS24 (microwave), or PASS24W (microwave), or PASA (infrared) PASAT3 PASAT3I } + PASAT3I (infrared) Opening sensor (a) + Safety during closing sensor (b) internal side (inside the operator s housing) Safety during opening sensor (outside or inside the operator s housing) 20

Manual release instructions DETACH AND DELIVER TO THE CUSTOMER In the event of maintenance, malfunctioning or emergency, pull the lock release lever VALSB down and turn it to the right or lower the lock release lever LOKSBM (if installed) and move the door wings manually into the open position. To block the door wings again, reposition the lock release lever to the initial position. WARNING: carry out the door wing blocking and release with the motor switched off. Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.entrematic.com 21

User instructions function selector The STOP position prevents the batteries from engaging in case of emergency. NOTE: for correct door operation and regular battery recharging, it is essential that the automatic system be always powered with batteries connected (also during the night). FUNCTION SELECTOR COME COMH-K DOOR OPEN 4 The door opens and remains open. TOTAL ONE-WAY OPENING 1 For one-way operation from the inside/outside of the door. TOTAL TWO-WAY OPENING 2 For two-way door operation PARTIAL OPENING 3 For two-way, one-way and partial opening operation. PARTIAL OPENING For two-way partial opening. DOOR CLOSED 6 The door closes and remains closed and locked (if lock is present). IMMEDIATE NIGHT-TIME CLOSURE (STOP) The door stops immediately when the NIGHT-TIME CLOSURE key is pressed for 3 s. 5 DELAYED NIGHT-TIME CLOSURE Pressing the NIGHT-TIME CLOSURE key, the door closes after 10 seconds (with J1=ON) or 60 seconds (with J1=OFF). This allows authorised door management personnel to get out before it closes. IMMEDIATE NIGHT-TIME CLOSURE The door stops immediately when the NIGHT-TIME CLOSURE is selected. POWER RESET Cancels the data acquired, proceeding with a new acquisition after 3 seconds. 1 5 DMCS Jack This is used to connect the DMCS software. N.B.: The DMCS jack can be accessed by removing the function selector switch cover. SETTING THE CODE (with J3=ON) The code can contain up to 5 numbers. Press the LOCK key for 3 seconds. Enter the numerical code. NOTE: the red LED flashes during this procedure. Press the LOCK key for 3 seconds. If the LED remains steady on, the selector is protected by an access code. CANCELLING THE CODE (with J3=ON.) Press the LOCK key for 3 seconds. Enter the numerical code. NOTE: the red LED flashes during this procedure. Press the LOCK key for 3 seconds. If the LED is switched off, the selector is working and no access code is set. 1 4 5 6 DMCS jack 2 3 DMCS jack POWER RESET DETACH AND DELIVER TO THE CUSTOMER 22

All the rights concerning this material are the exclusive property of Entrematic Group AB. Although the contents of this publication have been drawn up with the greatest care, Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publication. We reserve the right to make changes without prior notice. Copying, scanning and changing in any way are expressly forbidden unless authorised in writing by Entrematic Group AB. 23

Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.centrematic.com