Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Similar documents
Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 6213 EV, 6281 EV

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2000, 2002, 2012

Type 3320, Service Manual. Serviceanleitung Service Manuel

Type /2-way globe valve 2/2-Wege-Geradsitzventil Vanne à siège droit 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 2030, 2031, 2031 K, 2032, 2033, 2037

Type Pneumatic Control Unit. Operating Instructions

Type 3232, 3233, 3233 K, 3234, 3235, 3239

Type Pneumatic Control Unit. Operating Instructions

Type 2730, 2731, 2731 K DN Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Type 3360, Service Manual. Serviceanleitung Service Manuel

Type 8635 Remote-Positioner. Zusatzanleitung. English Deutsch Français

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Direct-acting 2/2- or 3/2-way pivoted armature valve

2/2- and 3/2-way solenoid valve for aggressive fluids

Type 2030, 2031, 2031 K, 2032, 2033, 2037

Type 2060, 2061, 2063, 2064, Accessories. Zubehör Accessoires

Type 8798 Remote Sensor. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Solenoid Valve ST-SA-series

Solenoid Valve DF-SB-series

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

3/2-way Solenoid Valve, direct-acting, NC or NO

Solenoid Valve DF-SA-series

Solenoid Valve ST-IA-series

Ex m Solenoid Operator Type 0519

BVS 13 ATEX E039X Type 8685 / Operating Instructions. Bedienungsanleitung Manuel d utilisation

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Direct-acting 3/2 way plunger valve

Type 8644 AirLINE. Operating Instructions. Bedienungsanleitung Manuel d utilisation. With decentralized peripheral system ET200S (Siemens)

Angle seat valve with piston actuator VZXA-...-K

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Angle seat valve with diaphragm actuator VZXA-...-M

Installation, Operation, and Maintenance Manual

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Angle seat valve with piston actuator VZXA-...-K

Type 8644 AirLINE. Operating Instructions. Bedienungsanleitung Manuel d utilisation. with I/O System 750 (Wago)

Swing Piston Compressors and Vacuum Pumps

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Pressure relief valve

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Direct-acting 2/2-way plunger valve

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type AS

Technical Data Sheet

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

Solenoid Operator 0516 / 1216

2/2 or 3/2 way direct acting rocker solenoid valve

A408 GB. Pneumatic oil and diesel pumps 1:1

Solenoid Operator 0513 / 1213

Insertion magnetic inductive flowmeter

GSR - your partner for valve technology. Welcome to the world of valve technology. Your GSR Team

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Directional Control Valve Series 4D01 (DENISON)

Assembly and Maintenance Manual Type ASNU

Operating pressure (bar) kv factor (m 3 /h) *3)

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Series PD directly operated solenoid valves

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

Installation, Operation, and Maintenance Manual

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Type 3280, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2-way motor valve 2-Wege-Motorventil Vanne motorisée 2 voies

Operating Instructions

Type Robolux multiple-way diaphragm valve. Operating Instructions

Installation, Operation, and Maintenance Manual

Series PD directly operated solenoid valves

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Solenoid valve type 150 direct action

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Diaphragm Vacuum Pumps and Compressors

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Solenoid System FLANGE MOUNTING VERSION

Diaphragm Vacuum Pumps and Compressors

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

2/2-way Solenoid Valve for liquids and gases

Micro Diaphragm Gas Sampling Pumps

Transcription:

Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

1 OPERATING INSTRUCTIONS The operating instructions contain important information. Read the operating instructions carefully and follow the safety instructions in particular, and also observe the operating conditions. Operating instructions must be available to each user. The liability and warranty for the device are void if the operating instructions are not followed. 1.1 Symbols Designates an instruction to prevent risks. designates a procedure which you must carry out. Warning of injuries: DANGER! Imminent danger! Serious or fatal injuries. WARNING! Potential danger! Serious or fatal injuries. CAUTION! Danger! Minor or moderately severe injuries. Warns of damage to property: NOTE! 2 INTENDED USE Incorrect use of the solenoid valve Type 0131 can be dangerous to people, nearby equipment and the environment. The device is designed to control, shut off and meter of neutral, PVC versions also aggressive media. Provided the cable plug is connected and installed correctly, e.g. Bürkert Type 2508, the device satisfies protection class IP65 in accordance with DIN EN 60529 / IEC 60529. Use according to the permitted data, operating conditions and conditions of use specified in the contract documents and operating instructions. Correct transportation, correct storage and installation and careful use and maintenance are essential for reliable and problemfree operation. Use the device only as intended. 2.1 Definition of term In these operating instructions, the term device always refers to the solenoid valve Type 0131. 2

3 BASIC SAFETY INSTRUCTIONS These safety instructions do not make allowance for any contingencies and events which may arise during installation, operation and maintenance. Danger high pressure! Before loosening the lines and valves, turn off the pressure and vent the lines. Risk of electric shock! Before reaching into the system, switch off the power supply and secure to prevent reactivation! Observe applicable accident prevention and safety regulations for electrical equipment! Risk of burns/risk of fire if used continuously through hot device surface! Keep the device away from highly flammable substances and media and do not touch with bare hands. Risk of injury due to malfunction of valves with alternating current (AC)! Sticking core causes coil to overheat, resulting in a malfunction. Monitor process to ensure function is in perfect working order! Risk of short-circuit/escape of media through leaking screw joints! Ensure seals are seated correctly. Carefully screw valve and connection lines together. General hazardous situations. To prevent injury, ensure that: Do not make any internal or external changes. Ensure that the system cannot be activated unintentionally. Installation and repair work may be carried out by authorized technicians only and with the appropriate tools. After an interruption in the power supply or pneumatic supply, ensure that the process is restarted in a defined or controlled manner. Do not put any loads on the body. The general rules of technology apply to application planning and operation of the device. 3

3.1 Warranty Circuit functions The warranty is only valid if the device is used as intended in accordance with the specified application conditions. 3.2 Information on the internet The operating instructions and data sheets for type 0131 can be found on the internet at: www.burkert.com Type 0131 4 TECHNICAL DATA 4.1 Operating conditions The following values are indicated on the type label: Voltage (Tolerance ± 10 %) / Current type Coil power consumption (active power in W - at operating temp.) Pressure range Body material: PVC (PV) or Brass (MS) Sealing material: FKM, EPDM, NBR A B C D E F A P A P A P R A P R A P1 P2 A B P 2/2-way valve; closed in rest position 2/2-way valve; opened in rest position 3/2-way valve; closed in rest position, output A unloaded 3/2-way valve; in rest position output A pressurized 3/2-way valve; in rest position, pressure connection P2 connected to output A. P1 closed 3/2-way valve; in rest position, pressure connection P connected to output B 4

Electrical operating conditions Ambient temperature (intermittent duty Fig. 2 ) Operating mode (according to DIN VDE 0580) Temperature protection switch Tab. 1: With high-performance electronics AC/DC Without electronics 50 Hz, 60 Hz max. +70 C max. +55 C Long-term operation Intermittent duty (Determination of the permitted operating parameters see Fig. 1 und Fig. 2 ) Device has a resettable temperature protection switch which switches the device off if unacceptable heating occurs during intermittent duty. Switches on again only after cooling down and after a new switching request. Electrical operating conditions Long-term operation Intermittent duty without Intermittent operation for version with high-performance electronics AC/DC Characteristic values (according to DIN VDE 0580) t SD Cycle time t ED Duty cycle t SP De-energized pause ED Relative duty cycle SH Switching frequency Fig. 1: t ED t SD t SP t SD [s] = t ED [s] = 60 SH 1 min ED[%] 100 x t SD [s] t SP [s] = t SD [s] t ED [s] Characteristic values intermittent operation for version with highperformance electronics AC/DC 5

Permitted operating parameters Relative duty cycle [%] 100 90 80 70 60 50 40 30 20 10 Fig. 2: 0 20 30 40 50 60 70 Ambient temperature [ C] Switching frequency 6/min 10/min 15/min Relative duty cycle (ED) depending on switching frequency and ambient temperature 4.2 Application conditions Ambient temperature max. +50 C Protection class IP65 in accordance with DIN EN 60529 / IEC 60529 with cable plug, e.g. Bürkert Type 2508 Operating duration Unless otherwise indicated on the type label, the solenoid system is suitable for continuous operation Important information for functional reliability during continuous operation: If standstill for a long period at least 1-2 activations per day are recommended. Service life High switching frequency and high pressures reduce the service life 4.2.1 Permitted temperature Permitted medium temperature depending on body material and sealing material PVC Version: Sealing material Permitted temperature FKM -10... +50 C EPDM -10... +50 C 6

Brass Version: Sealing material Version with high power AC/DC 1) Version without electronic 50 Hz, 60 Hz 1) NBR -10... +90 C -10... +90 C FKM -10... +90 C -10... +130 C EPDM -30... +90 C -30... +130 C 1) see description on the type label Viscosity: 37 mm 2 /s Brass Version: Sealing material NBR FKM EPDM Permitted media Neutral media, technical vacuum Per-solutions, hot oils without additives, diesel and heating oil without additives, detergent solution, technical vacuum Oil and grease-free liquids, cold and hot water, technical vacuum 4.2.2 Permitted media Permitted media depending on body material and sealing material PVC Version: Sealing Permitted media material FKM Oxidizing acids and substances, salt solution EPDM Alkalis, alkaline washing and bleaching lyes 4.3 Conformity In accordance with the EU Declaration of conformity, Type 0131 is compliant with the EU Directives. 4.4 Standards The applied standards, which verify conformity with the EU Directives, can be found on the EU-Type Examination Certificate and / or the EU Declaration of Conformity. 7

4.5 Type label Orifice Circuit function Type Made in Germany Id. Number 0131 A 10,0 FKM PV D16 P N 0-3 bar 230V 50 Hz 16 W 00050443 W12MN Manufacturer code Sealing material Body material Connection thread, Operating pressure Voltage, Frequency, Power consumption 5 INSTALLATION 5.1 Safety instructions DANGER! Risk of injury from high pressure in the equipment! Before loosening the pipes and valves, turn off the pressure and vent the lines. Risk of injury due to electrical shock! Before reaching into the device or the equipment, switch off the power supply and secure to prevent reactivation. Observe applicable accident prevention and safety regulations for electrical equipment. WARNING! Risk of injury from improper installation! Installation may be carried out by authorized technicians only and with the appropriate tools. Risk of injury from unintentional activation of the system and an uncontrolled restart! Secure system from unintentional activation. Following assembly, ensure a controlled restart. 8

5.2 Before installation Installation position: any, actuator preferably upwards. Procedure: Check pipelines for dirt and clean. Install a dirt filter before the valve inlet ( 500 µm). 5.3 Installation Insert O-ring Insert NOTE! Caution risk of breakage! Do not use the coil as a lever arm. Body with welded sleeve: Use PVDF. Body with PVC bonded sleeves: Use Tangit special adhesive. Valve body must not be installed under tension. Sealing material must not get into the device. Observe direction of flow: The arrow or letter on the body indicates the direction of flow: from P A (NC) or from P B (NO). Tighten union nut - evenly by hand only 9

5.4 Manual control CAUTION! Discharge of medium due to loss of the O-rings! If the O-rings are lost, the valve will leak. Medium may be discharged. NOTE! Caution! When the manual control is locked, the valve can no longer be actuated electrically. Manual control Press 1 5.5 Electrical connection of the cable plug WARNING! Risk of injury due to electrical shock! Before reaching into the system, switch off the power supply and secure to prevent reactivation. Observe applicable accident prevention and safety regulations for electrical equipment. If the protective conductor is not connected, there is a risk of electric shock! Always connect protective conductor and check electrical continuity. Note the voltage and current type as specified on the type label. Turn 2 10

Procedure: Tighten cable plug (for permitted types see data sheet), observing max. torque 1 Nm. Check that seal is fitted correctly. Connect protective conductor and check electrical continuity. Authorized cable plug e.g. Type 2508 or other suitable cable plug in accordance with DIN EN 175301-803 Form A max. 1 Nm Seal max. 1 Nm Seal 6 MAINTENANCE, TROUBLESHOOTING 6.1 Safety instructions WARNING! Risk of injury from improper maintenance! Maintenance may be carried out by authorized technicians only and with the appropriate tools! Risk of injury from unintentional activation of the system and an uncontrolled restart! Secure system from unintentional activation. Following maintenance, ensure a controlled restart. 6.2 Malfunctions If malfunctions occur, check whether: the device has been installed according to the instructions, the electrical and fluid connections are correct, the device is not damaged, all screws have been tightened, the voltage and pressure have been switched on, the pipelines are clean. 11

Malfunction Valve does not switch Valve does not close Possible cause Short-circuit or coil interrupted Medium pressure outside the permitted pressure range Manual control locked Internal space of the valve is dirty Manual control locked 7.2 Overview of spare parts Coil set 1 7 SPARE PARTS CAUTION! Risk of injury and/or damage by the use of incorrect parts! Incorrect accessories and unsuitable spare parts may cause injuries and damage the device and the surrounding area. Use only original accessories and original spare parts from Bürkert. 7.1 Ordering spare parts Order the spare-part sets specifying the positions (Pos. 1: coil set, Pos. 2: actuator set, Pos. 3: wearing part set) and the identification number of the device. 12 Wearing part set 3 Actuator set 2

8 TRANSPORT, STORAGE, DISPOSAL NOTE! Transport damages! Inadequately protected equipment may be damaged during transport. During transportation protect the device against wet and dirt in shock-resistant packaging. Avoid exceeding or dropping below the allowable storage temperature. Protect electrical interfaces of the coil and the pneumatic connections from damage with protective caps. Incorrect storage may damage the device. Store the device in a dry and dust-free location! Storage temperature: -10 C - +50 C (PVC) -30 C - +80 C (Brass) Damage to the environment caused by device components contaminated with media. Dispose of the device and packaging in an environmentally friendly manner. Observe applicable regulations on disposal and the environment. 13

Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940-10 91 111 Fax + 49 (0) 7940-10 91 448 E-mail: info@buerkert.com International address www.burkert.com Manuals and data sheets on the Internet: www.burkert.com Bedienungsanleitungen und Datenblätter im Internet: www.buerkert.de Manuel d'utilisation et fiches techniques sur Internet : www.buerkert.fr Bürkert Werke GmbH & Co. KG, 2014-2017 Operating Instructions 1710/05_EU-EN_00893158 / Original DE www.burkert.com