XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Similar documents
DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

LMK 387. Stainless Steel Probe DRUCK & TEMPERATUR LEITENBERGER GMBH. Ceramic Sensor

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

DMP 333. Industrial Pressure Transmitter For High Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20 DELTA

SITRANS P measuring instruments for pressure

Pressure transducer DMU 01K Compact version

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

JUMO MIDAS Pressure transmitter

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Pressure transmitter for industrial applications Type MBS 4510

Differential pressure transmitter PASCAL Ci4 Delta P

Mechatronic pressure measurement. Applications. Special features. Description

SATRON VT Pressure Transmitter

SATRON VDt Differential Pressure Transmitter

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

Pressure transmitter JUMO dtrans p02

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure gauge Model , copper alloy Model , stainless steel version

Reed sensor For bypass level indicators Model BLR

Pressure transducers. with flush connections. Pressure transducers. with SIL assessment. HydroFox for level measurement

SATRON VTe pressure transmitter

Absolute pressure gauge with diaphragm

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Pressure Transmitter JUMO dtrans p30 Type

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Flap-Type Flow Meter Prall

CTE8000 / CTU8000 Series

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

p Additional dimensions see section dimensions.

Design and application

Temperature sensor TE2

Flow switches Series AD/VH

Pressure transmitter for elevated media temperatures

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Pressure transmitters for industrial applications Type MBS 4510

SATRON VVFe Pressure Transmitter

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

* * Data sheet MA15F... A/B/C/D. Diaphragm manometer for explosive areas

Metal tube variable area flowmeter for gases, liquids and steam

CTE7000 / CTU7000 Series Miniature pressure transmitters

Flush-mounted pressure and level transmitters - KERAMESS KS series 100/101 -

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Compact differential pressure switch Models DC, DCC

Magnetic-inductive flow meter for hazardous areas

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

* * Data sheet DA01 VUW (ATEX) Differential pressure measuring device Pressure levels PN250/PN400. Models for use in explosive areas

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure Transmitters for Sanitary Applications Model SA-11

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Differential pressure gauge with diaphragm

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

* * Data sheet DA A (ATEX) Differential pressure measuring device for potentially explosive areas

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Compact pressure switch Model PCS

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Compact temperature switch Model TCS

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Differential pressure switch Model DPS40

KINAX SR 709 Transmitter for Position Feedback

ExBin-P Pressure switches 5 Pa Pa

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Smart Pressure Transmitter

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Pressure Transmitter JUMO dtrans p30 Type

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Hydrostatic. Overview 192 VEGABAR series VEGAWELL Accessory 200. Hydrostatic VEGABAR series 60 and VEGAWELL

JUMO MIDAS S05 Pressure transmitter Type

Flush-mounted pressure and level transmitters - KERAMESS KS S 200/201 - Superior Precision

Smart Pressure Transmitter

Transcription:

Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others on request Special characteristics turn-down 1:5 two chamber aluminium die cast case or stainless field housing internal or flush mounted capacitive ceramic sensor HART -communication IS-version: Ex ia = intrinsically safe version diaphragm Al 2 O 3 99.9 % Optional versions IS-version: Ex d = flameproof enclosure with integrated display and operating module several process connections (thread, flange, DRD etc.) The process pressure transmitter XMP ci measures the pressure of gases, steam and fluids. The special-developed capacitive ceramic sensor for this transmitter has a high overpressure capability and excellent media stability. Several process connections e.g. thread or flange are available. The transmitter is as a standard equipped with HART -communication, the can choose between a two chamber aluminum die cast case or a stainless field housing. Preferred areas of use are Oil and gas industry Chemical and petrochemical industry Preferred using in Fuel and Oil aggressive Media BD SENSORS GmbH BD-Sensors-Straße 1 Tel: +9 (0) 92 35 / 98 11-0 www.bdsensors.com D - 95199 Thierstein Fax: +9 (0) 92 35 / 98 11-11 info@bdsensors.de

Pressure ranges 1 Nominal pressure gauge [bar] 0.16 0. 1 2 5 10 20 Overpressure [bar] 6 8 15 25 35 5 Permissible vacuum [bar] -0.3-0.5-1 1 On request we adjust the devices by software to the required pressure ranges. Within the turn-down-possibility (starting at 0.02 bar). Output signal / Supply Standard 2-wire:... 20 ma intrinsically safe version with HART -communication V S = 12... 28 V DC Option 2-wire:... 20 ma IS version flameproof enclosure with HART -communication V S = 13 28 V DC Current consumption max. 25 ma Performance Accuracy 2 nominal pressure < 1 bar: ± 0.2 % FSO nominal pressure 1 bar: ± 0.1 % FSO for nominal pressure ranges: from 0.16 bar up to 0. bar ± (0.2 + (TD-1) x 0.02) % FSO for nominal pressure ranges: from 1 bar up to 20 bar ± (0.1 + (TD-1) x 0.01) % FSO with turn-down = nominal pressure range / adjusted range Permissible load R max [(V S V S min) / 0.02 A] Ω load during HART -communication: R min = 250 Ω Influence effects supply: 0.05 % FSO / 10 V permissible load: 0.05 % FSO / kω Long term stability ± 0.1 % FSO / year at reference conditions Response time 200 msec without consideration of electronic damping measuring rate 5/sec Adjustability electronic damping: 0 100 sec offset 0... 80 % FSO turn-down of span: max. 1:5 (span min. 0.02 bar) 2 accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal errors / Permissible temperatures Thermal error ± (0.02 x turn-down) % FSO / 10 K in compensated range -20 80 C Permissible temperatures 3 without display: medium: -25... 125 C environment: -0... 70 C storage: -0... 80 C with display: medium: -25... 125 C environment: -20... 70 C storage: -30... 80 C 3 for pressure port of PVDF the minimum permissible temperature is -30 C Electrical protection Short-circuit protection Reverse polarity protection permanent no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 61326 Mechanical stability Vibration Shock Materials Pressure port Standard Optionally for G1 1/2" flush Housing 5 g RMS (20... 2000 Hz) 100 g / 11 msec stainless steel 1.0 (316L) PVDF aluminium die cast, powder-coated or stainless steel 1.0 (316L) Cable gland brass, nickel plated Viewing glass laminated safety glass Seals (media wetted) FKM (permissible temperature: -25... 125 C) EPDM (permissible temperature: -0... 125 C) others on request Diaphragm ceramics Al 2O 3 99.9 % Media wetted parts Explosion protection Approval AX12-XMP ci (intrinsically safe version) IBExU 05 ATEX 1106 X Safety techn. maximum values Approval AX17-XMP ci (flameproof enclosure) Permissible temperatures for environment pressure port, seal, diaphragm stainless steel field housing zone 0/1 : aluminium die cast case zone 1 5 : II 1G Ex ia IIC T Ga II 1/2G Ex ia IIC T Ga/Gb II 1/2G Ex ia IIB T Ga/Gb II 2G Ex ia IIC T Gb II 2G Ex ia IIB T Gb zone 20: II 1D Ex ia IIIC T85 C Da U i = 28 V, I i = 98 ma, P i = 680 mw, C i = 0 nf, L i = 0 µh, C GND = 27 nf IBExU 12 ATEX 105 X aluminium die cast case: zone 1: II 2G Ex d IIC T5 Gb in zone 0: -20... 60 C with p atm 0.8 bar up to 1.1 bar in zone 1 or higher: -0... 70 C (intrinsically safe version); -20... 70 C (flameproof enclosure) The designation depends on the nominal pressure range. Nominal pressure ranges 160 mbar are marked with 2G. Nominal pressure ranges > 160 mbar and 10 bar are marked with 1/2G. Nominal pressure ranges > 10 bar are marked with 1G. 5 The designation depends on the nominal pressure range. Nominal pressure ranges < 160 mbar are marked with 2G. Nominal pressure ranges 160 mbar are marked with 1/2G. pressure and level

Miscellaneous Display (optionally) LC-display, visible range 32.5 x 22.5 mm; 5-digit 7-segment main display, digit height 8 mm, range of indication ±9999; 8-digit 1-segment additional display, digit height 5 mm; 52-segement bargraph; accuracy 0.1% ± 1 digit Ingress protection IP 67 Installation position any Weight min. 00 g (depending on housing and mechanical connection) Operational life > 100 x 10 6 pressure cycles CE-conformity EMC Directive: 201/30/EU ATEX Directive 201/3/EU Wiring diagram P supply + VS I supply Pin configuration Electrical connections Supply + Supply Test Shield Housing designs 6 (dimensions in mm) aluminium die cast case with display aluminium die cast case: terminal clamps (clamp section: 2.5 mm 2 ) IN+ IN- Test stainless steel field housing: terminal clamps (clamp section: 1.5 mm 2 ) IN+ IN- - stainless steel field housing with display G1/2" DIN 3852 aluminium die cast case without display G1 1/2" flush DIN 3852 stainless steel field housing without display 6 aluminium die cast case is horizontally rotatable as standard G1/2" DIN 3852 G1 1/2" flush DIN 3852 www.bdsensors.com

Standard pressure ports (dimensions in mm) G1/2" DIN 3852 G1/2" EN 837 1/2" NPT Process connections (dimensions in mm) Inch thread DRD 7 G1 1/2" flush DIN 3852 Flange (DIN 2501) dimensions in mm size DN25 DN50 DN80 D 115 165 200 k 85 125 160 d 68 102 138 b 18 20 20 f 2 3 3 n 8 d2 1 18 18 P N 0 bar 0 bar 16 bar 7 mounting flange is included in the delivery (already pre-assembled) HART is a registered trade mark of HART Communication Foundation; Windows is a registered trade mark of Microsoft Corporation flush diaphragm Ø26,5 Flange (ANSI) flush diaphragm Ø26,5 flush diaphragm Ø26,5 dimensions in mm size 2"/150 lbs 3"/150 lbs D 152. 190.5 g 91.9 127 k 120.7 152. b 19.1 23.9 n d 19.1 19.1 P N 10 bar 10 bar 2017 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. XMP ci_e_201217 pressure Tel: and +9 level (0) 92 35 / 98 11-0 www.bdsensors.com Fax: +9 (0) 92 35 / 98 11-11 info@bdsensors.de

Ordering code XMP ci XMP ci - - - - - - - - - - Pressure gauge 5 1 E Input [bar] 0.16 1 6 0 0 0. 0 0 0 1 1 0 0 1 2 2 0 0 1 5 5 0 0 1 10 1 0 0 2 20 2 0 0 2 9 9 9 Design Aluminium die cast case with display A 0 without display A N Stainless steel field housing with display without display F V F N 9 Output Intrinsic safety 20 ma / 2-wire with HART -communication I Intrinsic safety d 20 ma / 2-wire (flameproof enclosure) G 1 with HART -communication Accuracy P N < 1 bar: 0.2 % B P N 1 bar: 0.1 % 1 Electrical connection terminal clamp alu housing terminal clamp field housing A K 0 8 8 0 9 9 Mechanical connection standard pressure connections: G1/2" DIN 3852 G1/2" EN 837 1/2" NPT 1 0 0 2 0 0 N 0 0 process connections: G 1 1/2" DIN flush (DIN 3852) Flange DN 25 / PN 0 (DIN 2501) Flange DN 50 / PN 0 (DIN 2501) Flange DN 80 / PN 16 (DIN 2501) 2 Flansch DN 2" / 150 lbs (ANSI B16.5) 2 Flansch DN 3" / 150 lbs (ANSI B16.5) 3 DRD Ø 65 mm M 0 0 F 2 0 F 2 3 F 1 F 3 2 F 3 3 D R D 9 9 Diaphragm Ceramics Al 2 O 3 99,9% C Seals FKM 1 EPDM 3 Pressure port standard: Stainless steel 1.0 (316L) 1 option for G 1 1/2" flush: PVDF B Special version standard if setting range shall be different from nominal range please specify in your order 1 only possible in combination with aluminium die cast case 2 2"/150 lbs and 3"/150 lbs only possible for nominal pressure ranges PN 10 bar 3 mounting flange is included in the delivery (already pre-assembled) permissible temperature FKM -25 125 C, EPDM -0 125 C, PVDF -30 125 C HART is a registered trade mark of HART Communication Foundation; Varivent is a brand name of GEA Tuchenhagen GmbH 0 0 0 9 9 19.01.2016 2016 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.