CENTRAL ADAPTER KIT INSTALLATION manual EPURAIR MA-1 HEPA AIR FILTRATION SYSTEM
8 8 6 6 Epurair MA-1 - Central Application Installation Manual PAGE 2 Included In the CONVERSION kit METAL SCREWS x 4 WOOD SCREWS x 2 ADAPTER PLATE (FACTORY INSTALLED ON THE MA-1C) WALL mounting BRACKET x 1 UNIT BRACKET x 1 RUBBER STANDS x 4 NOT Included In the kit 8 INCHES SIDE TAKEOFF WITH DAMPER x 1 6 INCHES SIDE TAKEOFF x 1 ROLL OF DUCT TAPE 8 INCHES FLEXIBLE CONDUIT* 6 INCHES FLEXIBLE CONDUIT* * Rigid conduits can also be used but make sure that there is enough clearance to the top (see step 5) to service the unit.
PAGE 3 OVERVIEW OF THE FINISHED INSTALLATION 8 INCHES SIDE TAKEOFF WITH DAMPER 8 INCHES FLEXIBLE CONDUIT WALL BRACKET AIRFLOW AIR EXIT FURNACE AIR ENTRANCE 6 INCHES FLEXIBLE OR RIGID CONDUIT 6 INCHES SIDE TAKEOFF
PAGE 4 1- CONVERTING THE PORTABLE UNIT UNSCREW AND REPLACE THE LOUVER GRILL WITH THE PROVIDED CENTRAL ADAPTER PLATE (IF CONVERTING FROM PROTABLE MODEL) 2- REPLACING OR INSTALLING THE RUBBER FEET REMOVE WHEELS AND INSTALL THE RUBBER STANDS (IF CONVERTING FROM PROTABLE MODEL) X 4 X 4
PAGE 5 3- LOCATING AND CUTTING HOLES INTO THE DUCTS AIR EXIT AIRFLOW 8 INCHES SIDE TAKEOFF OPENING LOCATED UPSTREAM OF AIRFLOW (OPENING SIZE MAY VARY ACCORDING TO YOUR SIDE TAKEOFF MODEL SPECS.) IMPORTANT: 4 FEET MINIMUM DISTANCE BETWEEN THE TWO OPENINGS FURNACE AIR ENTRANCE 6 INCHES SIDE TAKEOFF OPENING LOCATED DOWNSTREAM OF AIRFLOW (OPENING SIZE MAY VARY ACCORDING TO YOUR SIDE TAKEOFF MODEL SPECS.) 4- INSTALLING THE SIDE TAKEOFF AIRFLOW IMPORTANT: INSTALL DAMPERED SIDE TAKEOFF BY MAKING SURE THE DAMPER IS CORRECTLY ORIENTED TO CATCH AND DIVERT THE AIRFLOW TO THE MACHINE. INSTALL REMAINING SIDE TAKEOFF AND FLEXIBLE CONDUITS LEAVING ENOUGH LENGTH SO THE HEPA UNIT CAN REST ON THE FLOOR WITHOUT PUTTING ANY STRAIN ON THE CONDUITS.
PAGE 6 5- LOCATING THE WALL MOUNTING BRACKET IF SUSPENDED ON THE WALL ALLOW 18 IN. OF CLEARANCE WITH OVERHEAD OBSTACLES TO ALLOW INSPECTION OF THE UNIT WITHOUT UNHOOKING IT FROM THE WALL IMPORTANT: ALLOW ENOUGH CLEARANCE SO THERE WILL BE NO KINKS IN THE CONDUITS ONCE THE UNIT IS HOOKED ON THEWALL 6- INSTALLING THE WALL MOUNTING BRACKET USING THE TWO WOOD SCREWS FIX THE WALL MOUNTING BRACKET. BE SURE TO SCREW INTO A WALL STUD OR INTO A SOLID UNDERBACKING LIKE CONCRETE
PAGE 7 7- INSTALLING THE MOUNTING BRACKET ON THE HEPA UNIT If you decide to hang THE UNIT to THE wall BRACKET CAN BE INSTALLED LEFT OR RIGHT ALIGN TOP OF BRACKET WITH THE TOP OF UNIT COVER 6-3/4 FROM BACK USE THE 4 PROVIDED METAL SCREWS TO FIX THE BRACKET TO THE UNIT NOTE : Although the unit is meant to be hung some people leave it on the floor when they are unable to find a wall close enough.
PAGE 8 8- CONNECTING THE HEPA UNIT AND SEALING THE JOINTS FIX THE CONDUITS ON THE HEPA UNIT AND HOOK IT ON THE WALL BRACKET SEAL ALL OPENINGS WITH GOOD QUALITY DUCT TAPE
PAGE 9 9- Finishing the installation PLUG THE UNIT DIRECTLY IN A 3 PIN GROUNDED ELECTRICAL OUTLET WITHOUT USING ANY EXTENTION CORD TURN THE SPEED SELECTOR TO 3 0 1 2 3 YOU R DONE