MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER

Similar documents
MODEL RPM10/RPM20 (-LON)/RPM20-CC PRESSURA ROOM PRESSURE MONITOR

MODEL 8631-CRM/8631-CRC PRESSURA CLEAN ROOM PRESSURE MONITOR/CONTROLLER

MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER

MODEL 8631-HM(-BAC)/8631-HC(-BAC) PRESSURA ROOM PRESSURE MONITOR/CONTROLLER

MODEL 8630 PRESSURA ROOM PRESSURE MONITOR

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

MODEL 8636 / 8636-LN / 8636-BAC SUREFLOW ROOM PRESSURE CONTROLLER

MODEL 8635 SUREFLOW ROOM PRESSURE MONITOR

RPM1600 Series Room Pressure Monitors

Model FHS5 Slimline Display Interface for FHC50/FHM10 P/N Installation Instructions

INSTALLATION INSTRUCTION

ComfortPoint Programmable Lon, VAV/Unitary Controllers

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

INSTALLATION INSTRUCTION

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

Healthcare Solutions Room Pressure Monitors and Controls

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

OE326-23I-OR VAV/Zone Controller

Excel 10 W7751H3007 VAV ACTUATOR

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Laboratory Exhaust Air Terminal

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

Laboratory Room Controller

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

HVAC Products. Introducing the SED2 Variable Frequency Drives

AMD-33 Air Measuring Station with VCD-33 Control Damper

Spyder BACnet Programmable Controllers

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

F-2600 SERIES INLINE VORTEX FLOW METER

BAPI-Stat 3 Room Sensor

Minimum 27 in-lb Torque

LOW PRESSURE CELERIS CONTROLLERS

MicroTech II Applied Rooftop Unit Controller

Installation, Operation and Maintenance Manual

Excel 15 W7760A BUILDING MANAGER

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Air Pressure Sensing Switch with Adjustable Set Point Range. Dimensions in Inches (Millimeters)

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

TRAC-Station BT Installation Instructions

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

How to Select the RE Industrial Actuator Part Number

Installation and Start-Up Instructions

7/S5 FIRE DAMPER FD40. v 2.9 (en)

Excel 10 W7751J Smart VAV Actuator

Air Quality Solutions

Description. functions including single duct pressure dependent or pressure independent systems.

A25 Series Warm Air Control with Manual Reset

LF Series Spring Return Direct Coupled Actuator

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

Minimum 27 in-lb torque

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

ACCUVALVE MODEL AVT6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVT6000 AVT6 - - DWG. NO: REVISION: REV. DATE:

Silver Series Thermal Dispersion Airflow Measurement Technology

MA-5200 Series MA-5300 Series

Acid Resistant AVC6000

COMPLETE and FULLY INTEGRATED AIR PRESSURE CONTROL & MONITORING SYSTEMS

Powers TM Controls EA 338 Electronic Actuator

Excel 10 W7751H SMART VAV ACTUATOR BEFORE INSTALLATION INSTALLATION

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

F-2700 SERIES INSERTION VORTEX FLOW METER

TMS Series MP46x Flex Probes* Installation Instructions

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

MicroTech II Applied Rooftop Unit Controller

WINDSHIELD WIPER SERVICE KIT

ECCII to ECCIII Upgrade Kit

TRAC-3 TENSION READOUT AND CONTROL

Application Engineering

YCCS Zone/Bypass Damper Assembly

Application Engineering

Excel 10 W7751J Smart VAV Actuator

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

FT-10 Network Digital I/O Module Kits and

Transcription:

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER INSTALLATION INSTRUCTIONS WARNING The Model RPC30 (-LON) Room Pressure Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause serious damage to the unit and void the warranty. The pressure sensor must be mounted through the wall between the controlled space (isolation room) and referenced space (ante room / hallway). Go to www.tsi.com to download the Operation and Service Manual for the Model RPC30. These installation instructions guide the installer through the installation of the TSI Model RPC30 (-LON) PresSura Room Pressure Controller. Please read these instructions thoroughly before beginning installation. This product is classified by UL as to fire resistive properties only. See UL File R15545. Component List Part Number Qty Description 800243 1 Pressure sensor with cable or 801913 1 Transducer Pickups 800983/800984 1 RPC30 / RPC30-LON Room Pressure Controller Figure 1: Typical Installation TSI and TSI logo are registered trademarks of TSI Incorporated. PresSura is a trademark of TSI Incorporated. BACnet is a trademark of ASHRAE. Modbus is a registered trademark of Modicon, Inc. LonWorks is a registered trademark of Echelon Corporation.

Pressure Sensor Installation WARNING 800243 pressure sensor must be mounted through the wall between the controlled space (isolation room) and referenced space (hallway), exactly as shown in Figure 1 and Figure 3. Determine pressure sensor location (Figure 1, Figure 3 and Figure 4). Pressure sensor typically mounts in the reference space, and the dummy housing mounts in the isolation room. NOTE: Pressure sensor is not symmetrical. If sensor is to be centered over hallway door, measure one inch to the left of center for 2¼ hole. Dummy sensor will be 2 off center on other side of wall. The pressure sensor must be orientated on the wall as shown in Figure 2. Looking at the mounted sensor, sensor hole is on the left (2¼ ) and wire hole is on the right. Drill a 2¼ hole through each side of the wall to accept the sensor tube. Drill a 7 8 hole on the side of the wall that the pressure sensor will be mounted. This hole is for the six-conductor sensor cable. Refer to Figure 2 for a hole mounting pattern. Slide sensor cover to right and remove screw that holds the sensor base to the pressure sensor (Figure 2). Remove pressure sensor and store in a safe place. From the side of the wall the sensor will be mounted, slide the sensor tube through the wall. Mark the tube where it is flush with wall. Remove sensor tube and cut tube 1 8 inch shorter than flush marking. NOTE: If 12 sensor tube needs to be extended, use same size or larger diameter tube. Drill out ½ sensor hole in dummy case to match ID of tube extension. From the side of the wall the sensor will be mounted, slide the sensor tube through the wall. Slide the dummy base over the end of the tube. Screw the pressure sensor base and dummy base to the wall (Figure 3 and Figure 4). Figure 2: Pressure Sensor Orientation and Mounting Template Wire the pressure sensor per Figure 8 to Figure 28. Run sensor cable to the room pressure controller 6 4 electrical roughin box. Insert fire protection sealant (provided) into 78 wire hole to seal. Install and screw the pressure sensor and dummy cover onto the bases. Slide covers to the left to hide the sensor. Finished installation should look as shown in Figure 4. WARNING Do not touch the sensor element in the pressure sensor. Do not run wires through the air passage. Doing so will damage the sensing element. p. 2 of 20

CEILING ½ THE DISTANCE BETWEEN CEILING & DOOR JAMB DUMMY COVER CONTROLLED SPACE WALL PRESSURE SENSOR BLACK FIRE SEALANT RING MUST INSERT INTO 2 ¼ HOLE REFERENCE SPACE (TYPICALLY A HALLWAY) Figure 3: Cutaway View of Mounted Pressure Sensor Figure 4: Pressure Sensor Mounting p. 3 of 20

Pressure Transducer Installation WARNING 801913 pressure plates must be mounted in the wall between the controlled space (clean room) and referenced space (hallway), exactly as shown in Figure 5 and Figure 6. This installation is not representative of the through penetrating product tested under UL. Install pressure transducer in desired location (typically above ceiling). The transducer must be mounted on a wall in the correct position per Figure 5 (screws not provided). Do not mount pressure transducer to duct or other vibrating surface. Wire the pressure transducer per Figure 10 or Figure 11. Run sensor cable to the Clean Room Pressure Controller 6 4 electrical rough-in box. Determine pressure sensor location (Figure 1, Figure 5 and Figure 6). Pressure sensor typically mounts in the reference space, and the plate mounts in the clean room. Drill a 2¼-inch hole through each side of the wall to accept the sensor tube. Run pneumatic tubing from transducer to sensor locations. For a positively pressurized space, the high port should be connected to the controlled space and the low port to the reference space. Similarly, for a negatively pressurized space, the low port should be connected to the controlled space and the high to the reference space. Connect the pneumatic tubing to the nipple on the back side of the pressure plate. Insert the pressure plate into the hole in the wall. Screw the pressure plate to the wall. The finished assembly should look like Figure 5. Figure 5: Cutaway View of Mounted Pressure Transducer Assembly Figure 6: Pressure Transducer Mounting Plate p. 4 of 20

Pressure Controller Installation Pressure Controller Rough-in Select the mounting location of the pressure controller. The construction plans normally show the mounting location. If no location is specified, then the unit is typically installed as shown in Figure 1. Alternate mounting locations are nurses station, other staff areas, etc. Install a standard triple gang electrical box (6 4 ). The electrical box must be installed level and flush with the wall surface. Use appropriate firestop material, per local codes, if electrical box is to be installed in a fire barrier. Screw PresSura DIM to electrical box (Figure 7). Pressure Controller Wiring Figure 7: Pressure Controller Mounting WARNING Do not connect more than 24 VAC to any terminal. Do not apply voltage to the RS-485 output, BACnet output, analog output, or control output. Severe damage may occur to the unit if voltage is applied. Wiring Recommendations TSI recommends stranded wire. Comply with local and national electrical codes. Follow good wiring practices: o Do not run control wiring in the same conduit or wireway as power wiring. o Control cables should cross power cables at a 90-degree angle. o Use a consistent color code to maintain polarity. o Control signals require home run wiring / star configuration. Do not daisy-chain control wires or use a series configuration. o Use daisy-chain configuration for connecting the nurses station to monitors and controllers. Remove the connectors from the back of the pressure controller. Refer to the wiring diagrams, Figure 8 to Figure 28 for proper wiring installation. If additional options need to be wired, refer to building prints for proper wiring diagram. Plug the connectors back into the pressure controller. Carefully push the wires into the electrical box and mount the pressure controller. Install four screws to hold pressure controller firmly to base. Install cover and slide left to hide display. p. 5 of 20

Press cover plate onto PresSura Controller. Power Requirements Digital Interface Module (DIM) Each 24VAC, 50/60 Hz, 3VA Through the Wall Sensor Each 24VAC, 50/60 Hz, 3VA WARNING: Controller must be wired exactly as wire diagram shows. Making modifications to the wiring may severely damage the unit. Figure 8: Wiring Diagram Through-The-Wall Sensor Wiring to Model RPC30 p. 6 of 20

WARNING: Controller must be wired exactly as wire diagram shows. Making modifications to the wiring may severely damage the unit. Figure 9: Optional Anteroom Through-The-Wall Sensor Wiring to Model RPC30 p. 7 of 20

Figure 10. Wiring Diagram Pressure Transducer Sensor to Model RPC30 p. 8 of 20

Figure 11. Optional Anteroom Pressure Transducer Sensor Wiring to Model RPC30 Figure 12. Optional Supply & Exhaust Flow Switch Wiring to Model RPC30 p. 9 of 20

Figure 13. Optional Supply & Exhaust Pressure-Based Flow Station Wiring to Model RPC30 Figure 14. Optional Supply & Exhaust Linear Flow Station Wiring to Model RPC30 p. 10 of 20

Figure 15. Optional Supply & Exhaust Venturi Valve Wiring to Model RPC30 Figure 16. Optional Door Switch Wiring to Model RPC30 p. 11 of 20

Figure 17. Optional Occupancy Sensor Wiring to Model RPC30 Figure 18. Optional Temperature Sensor Wiring to Model RPC30 p. 12 of 20

Figure 19. Optional Keyswitch Wiring to Model RPC30 p. 13 of 20

Figure 20. Optional Keyswitch with Remote Alarm Wiring to Model RPC30 p. 14 of 20

Figure 21. Optional Relative Humidity Sensor Wiring to Model RPC30 Figure 22. Optional Temperature Setpoint Wiring to Model RPC30 p. 15 of 20

24V IN + - 24V OUT INPUT 1 SENS COMM + - + - A B RELAY 1 RELAY 2 ALARM ALARM INPUT 3 INPUT 4 INPUT 2 INPUT 5 INPUT 6 INPUT 7 + - + - + - + - + - + - EXH CNTRL OUTPUT 2 OUTPUT 3 + - + - + - NURSE COMM B A REF BAC/LON/MOD B A REF TEMPERATURE SENSOR Figure 23. Optional Supply Air Temperature Sensor Wiring to Model RPC30 Figure 24. Optional Supply & Exhaust Actuator Wiring to Model RPC30 p. 16 of 20

Figure 25. Optional Reheat Actuator Wiring to Model RPC30. NOTE: A 120Ω resistor should be installed on both ends of the RS-485 loop. Figure 26. Wiring Diagram Optional Nurses Station Communications Wiring to Model RPC30 p. 17 of 20

NOTE: A 120Ω resistor should be installed on both ends of the RS-485 loop. Figure 27. Optional Modbus and BACnet MS/TP Communications Wiring to Model RPC30 Figure 28. Optional LONworks Communications Wiring to Model RPC30 p. 18 of 20

Figure 29. Proper Communication Wiring Diagram p. 19 of 20

TSI Actuator/Damper Installation WARNING Building prints normally determine damper location and mounting configuration. They supersede the guidelines below. The actuators are shipped mounted to the damper. No adjustments are needed prior to mounting the assembly. The damper must be installed with the damper shaft parallel to the ground (Figure 30). Slip-fit dampers mount INSIDE the duct work. Flanged dampers bolt to the duct work. No ductwork can be inside of dampers, or interfere with damper rotation. Screw slip-fit damper to duct work using 1-inch or shorter screws. Make sure screws do not interfere with damper blade rotation. Bolt flanged dampers securely to ductwork, but do not force damper to fit (deforms damper). Figure 30. Proper Damper Mounting NOTE: If you need assistance installing the system, call TSI Customer Service at (800) 874-2811. TSI Incorporated Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 P/N 6006662 Rev. E 2018 TSI Incorporated Printed in U.S.A.