Universal push-button dimmer with PLC interference suppression, W, 2-wire

Similar documents
General catalogue INTERNATIONAL

Transformers for Low-voltage Halogen Incandescent Lamps

Wiring devices Asfora 2015 catalogue

Wiring Accessories. low voltage. Wiring Accessories

Pack Cat.Nos Switches16A-250VA. 1 gang - standard switches One-way switch Two-way switch Intermediate switch

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

SWITCHES - 230V. available as double push-buttons (i.e. 2 functions per lever) and as a regular switch.

Installation & User Instructions

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

Operating Instructions. Tronic Dimmer

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

CONTROL UNITS LOCAL EXTRACTORS LOCAL EXTRACTORS. Pure advantage

Power Switching Devices

1 Phase electronic contactor (SC 1)

Millenium Functionality is more than switching on or off

DELTA i-system. 1/6 Introduction. 1/7 Switches and pushbuttons. 1/13 Shutter/blind controls. 1/19 Socket outlets

CI-TI Contactors and Motor Starters Type CI 6-50

PD-Series Ground Fault Circuit Protection

ICG Switchgear Price List 2009

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.


Installation. Mounting frames - TECHNICAL CHARACTERISTICS. Conformity to Standards LV Directive EN Standard

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions

Grosvenor Plus 138 decorative Solid brass highly polished, with rope-edge detail Pre-treated heat-cured powder lacquer finish Total safety

FIRE CONTROL

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

18000 series Snap-action momentary pushbutton switches

Local Control Network - building controls in perfection

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

Application. Battery. Public Grid GS HYBRID INVERTER

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

JUMO MIDAS Pressure transmitter

DIMMERS. Slide Dimmers C3. Rotary Dimmers. Touch Dimmers C5. Decorator Dimmers C6 C-1

8000 series Momentary or alternate action pushbutton switches

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

ADEL - BARA NESO - NG

Solar off-grid Inverter. SP Junior Series. User Manual

LED CONVERTERS FOR LED MODULES 24 V

3.5 Amp Bi-polar stepper motor drive MSE570 Evo 2

Graze MX Powercore high-intensity illumination of multistorey. surfaces. ew Graze MX Powercore. Benefits. Features

Dimmer / 2-Way Dimmer

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

Replace ** for the required coil voltage eg: P7 (230V 50/60Hz) Co nt act or Heating Guides, 9-95A

2.7. IT system floor-standing distribution cabinet Series -IPS-F

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

Wall Light, 1x11W IP20. Mounting 4 mounting holes, Ø 5 mm

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

9000 SERIES SUBMINIATURE MOMENTARY PUSHBUTTON SWITCHES Overview

1SVC F SVC F 0607 R100.20/30 R100.45

Emergency lighting units EM INVERTER

GP12 TECHNICAL MANUAL

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

MX431 Generator Automatic Voltage Regulator Operation Manual

Pushbutton switches & indicators. Panel Sealed to IP65. Push on tab terminals 6A 250VAC AGENCY APPROVALS

CI-TI Contactors and motor starters Types CI 61 - CI 98

TS-350 Fully-Flush Under Vehicle Inspection Light Packages

2-Way Dimmer (1 Gang)

FR circuit breaker - hydraulic magnetic,

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

CONSUMER LIGHTING PRODUCT CATALOGUE

DPX moulded case circuit breakers

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Pushbutton switches & indicators. Panel Sealed to IP65. Push on tab terminals 6A 250VAC AGENCY APPROVALS

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

SERIES 1000 ELECTRIC ACTUATORS

Electronic Circuit Breaker ESS20-0..

Step A decisive step forward

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

Series Motor Protection

Prewired position switches FF series

Mini Contactors CI 4-

General_technical_data Series

ACTUATORS POSITION SENSOR

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

LED CANOPY with j-box

Merilux. Lamps for surgery and examination

LEDtape 800 TW Tunable White K CRI>90

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

2-Way Dimmer (1 Gang)

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

DELTA natur 77/1 7/1. 7/6 Frames. 7/7 Switches and pushbuttons. 7/9 Outlets. 7/10 Lighting control. 7/11 Shutter/blind control. 7/12 Communication

ELECTRICAL PANELS. Chap.

Prewired position switches FF series

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)

Electronic Temperature Sensor ETS 300

Transcription:

Technical data sheet 310-0190X - Universal flush-mounting rotary dimmer with PC interference suppression, 5-325 W 4 year warranty R,,C CFi oads type of max. min. 325 W 325 W HA. 12-24 V 325 W CFi lamp (max. 10) (max. 10) 230 Vac ± 10%, 50 Hz flush-mounting box with flush-mounting depth of min. 40 mm Command rotary button o-load power consumption < 0.5 W housing temperature (Tc) 90 C wire diameter per connection terminal 2 x 2.5 mm² load Protection protected against thermal overload and short-circuit distance between dimmer and rotary button extension(s) (310-0200x) 75 m Weight 70 g amp-specific dimmer curve adjustable (DIP switches) dimming level adjustable Standards 60669-2-1 Pack 1 xtension rotary button extension (310-0200x) Up to five extra rotary button extensions can be connected to this dimmer. Finishing (or central plate) 1xx-31003 PD-310-0190X-11 lamp

DATASHT Universal push-button dimmer with PC interference suppression, 3, 2-wire Base 310-02900 Dimmer for incandescent lamps, 230 V halogen lamps, all low-voltage halogen lamps and lamps. Connected with 2-wire system. The flush-mounting frame has internal dimensions of 45 x 45mm, centre-to-centre distance of 60 x 71 mm and is equipped with claw fixings. Finishing set XXX-31002 Finishing set for electronic switch or push button. Available in any iko finishing colours. Flush surround plate Can be combined with all single or multiple iko flush surround plates from the Original, Intense and Pure series. Base 310-02900 Base for universal push-button dimmer plus, 3-, with claw fixing Centraalplaat 100-31002 Cream 101-31002 White 102-31002 ight grey 104-31002 Greige 121-31002 Sterling 122-31002 Anthracite 123-31002 Bronze 124-31002 Dark brown 154-31002 White coated 157-31002 Champagne coated 161-31002 Black coated 200-31002 Bakelite piano black coated 220-31002 Alu steel grey coated 221-31002 Alu gold coated

DATASHT Technical data Minimum load Maximum load Maximum load lamps ight value memory xpansion control points Safety protections Interference suppression Power consumption standby Connection terminals Markering 230 Vac ± 10 %, 50 Hz push button - lamps (max. 10) Yes.O. push buttons, also in case of the replacement of single-pole, two-way or intermediate switching overload protection with automatic reset function electronic short-circuit protection CAB interference suppression 0,15 W 2 x 2,5 mm² + 35 C C-gemarkeerd oads amp lamp (max. 10) Wiring diagram 0 max. 30 x 230 Vac 230 Vac iko nv Industriepark West 40 B-9100 Sint-iklaas tel. +32 3 778 90 00 fax +32 3 777 71 20 www.niko.eu PD-310-02900-11 sales@niko.be

1X 1X DATASHT Universal rotary dimmer with powerline communication interference suppression, 3 -, 2-wired Base 310-03900 / 310-03901 Dimmer for incandescent lamps, 230 V halogen lamps, all low-voltage halogen lamps and lamps. Connected with 2-wire system. The flush-mounting frame has internal dimensions of 45 x 45mm, a centre-to-centre distance of 60 x 71 mm and is equipped with claw fixing (310-03900) or for screw fixing (310-03901). Finishing set XXX-31003 Finishing set for this rotary dimmer. Available in any iko finishing colours. Flush surround plate Can be combined with all single or multiple iko flush surround plates from the Original, Intense and Pure series. Base 310-03900 DFAUT HAO 2-3X Base for universal rotary dimmer 3 -, with claw fixing 310-03901 DFAUT HAO 2-3X Base for universal rotary dimmer 3 -, for screw fixing Central plate 100-31003 Cream 101-31003 White 102-31003 ight grey 104-31003 Greige 121-31003 Sterling 122-31003 Anthracite 123-31003 Bronze 124-31003 Dark brown 154-31003 White coated 157-31003 Champagne coated 161-31003 Black coated 200-31003 Bakelite piano black coated 220-31003 Alu steel grey coated 221-31003 Alu gold coated

DATASHT Technical data Minimum load Maximum load Maximum load lamps ight value memory xpansion control points Safety protections Interference suppression Power consumption standby Connection terminals Marking 230 V AC ± 10%, 50 Hz Rotary dimmer - lamps (max. 10) yes.o. push buttons, also in case of the replacement of single-pole, two-way or intermediate switching overload protection with automatic reset function electronic short-circuit protection PC interference suppression 0.15 W 2 x 2,5 mm² 35 C C marked oads amp lamp (max. 10) O HA 3X 2-0 DF 1X AUT O HA 3X 2- DF 1X AUT Wiring diagram max. 30 x 230 Vac 230 Vac iko nv Industriepark West 40 B-9100 Sint-iklaas tel. +32 3 778 90 00 fax +32 3 777 71 20 www.niko.eu PD-310-0390x-11 sales@niko.be

Technical data sheet 330-00700 - ew universal dimmer 5 W to 4 year warranty R,,C CFi 3 4 1 2 oads amp HA.230 V 230 Vac ± 10%, frequency 50 Hz DI rail (1 TU) O or potential-free (8 24 V) Own consumption ± 0.6 W temperature of housing (Tc) 90 C terminal HA.12-24 V CFi 2.5 mm² Power supply and load Input load Protection Protection against thermal overload and short-circuit Push buttons 230 Vac; 5 ma (not galvanically isolated) or 8 24 Vdc (variable voltage) -5 C + 55 C distance to the last push button 100 m Weight 70 g amp-specific dimmer curve Adjustable (DIP switches) dimming level Adjustable xtra functions All off staircase function light value memory Standards 60669-2-1 Packaging 1 PD-330-00700-11R11383 wire diameter per connection PD-330-00700-91.indd 3 HA.230 V 21/09/11 11:16

Technical data sheet 330-00701 - ew universal dimmer 5 W to : analogue 4 year warranty R,,C CFi 3 4 1 2 oads amp HA.230 V HA.230 V 230 Vac ± 10%, frequency 50 Hz DI rail (1 TU) 1 10 V current control ± 0.6 W temperature of housing (Tc) 90 C terminal CFi 0 10 V voltage control Own consumption wire diameter per connection HA.12-24 V 2.5 mm² Power supply and load Input load Protection Protection against thermal overload and short-circuit -5 C + 55 C Input impedance 0 10 V: 33 kω PD-330-00701-91.indd 3 distance to the last push button 100 m Weight 70 g amp-specific dimmer curve Adjustable (DIP switches) dimming level Adjustable Standards 60669-2-1 Packaging 1 PD-330-00701-92R11383 1 10 V: 22 kω 21/09/11 11:15