MOULDED CASE CIRCUIT BREAKERS BC160N

Similar documents
MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Overcurrent releases - description, specifications, characteristics specifications specifications description...

MOULDED CASE CIRCUIT BREAKERS BL1600S

3VT Kompaktleistungsschalter bis 630A

3VT1 Molded Case Circuit Breakers up to 160 A

SENTRON 3VT Molded Case Circuit Breakers up to 1600 A

3VT5 Molded Case Circuit Breakers up to 1600 A

3VT2 Molded Case Circuit Breakers up to 250 A

DATA SHEET 3VT3 MCCB ACCESSORIES

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS

3VT5 Molded Case Circuit Breakers up to 1600 A

Fuse switch-disconnectors

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

Fuse switch-disconnectors

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

max pole for t=15 ms

3VU13, 3VU16 Circuit-Breakers

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50

Devices for switching and control

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX moulded case circuit breakers

Air Circuit Breakers

vertical fuse switch disconnectors

DMX 3 -I 2500 switch disconnectors

Air Circuit Breakers

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Moulded case circuit breakers. Change of parameters of the motor drives MP-BL-X230 and MP-BL-X110

Fuse switch disconnectors

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

cor Long Run Experience

Siemens AG VT3 Molded Case Circuit Breakers up to 630 A

3 - Protection components Motor circuit-breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

3NP1 Fuse Switch Disconnectors up to 630 A

Fuse switch disconnectors

Low voltage moulded case circuit breaker EB2

BETA Switching Switches and Light Indicators

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Residual current circuit breakers with conditional shortcircuit

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

DPX 630 Electronic release

DPX 1600 Electronic release

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

Protection components

15-I73E CAT REF.

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MC FRAME SIZE 1 / UP TO 160A

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

SENTRON Switching and Protection Devices Switch Disconnectors

18-I73E CAT REF.

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

Control Circuit Protection

Thermal Overcurrent Circuit Breaker 3120-F...

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

3VT Molded Case Circuit Breakers up to 1600 A

Thermal Overcurrent Circuit Breaker 3120-F...

MULTIVERT 250A Size 1, 690VAC

14-I73E CAT REF.

MS General Information Extended Product Type: MS

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal magnetic and trip-free switches

3VT3 Molded Case Circuit Breakers up to 630 A

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

SENTRON VL Series Product Specifications

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

MS25, MST25, MS20, MST20

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3120-F...

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)

Thermal Overcurrent Circuit Breaker 3120-F...

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

Thermal Overcurrent Circuit Breaker 3120-F...

Protection Equipment. 5/2 Introduction

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

D509E. Manual Motor - Starters

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

and other modular devices for low voltage installation

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Phone: Fax: Web: -

Technical Data Accessories MCBs Ex9B.

Signal lamps RS, RSB A20. Technical data RS, RSB. Dimensional drawing of RS, RSB. Number of poles Rated voltage Un

Protection Equipment

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Transcription:

D MOULDED CASE CIRCUIT BREAKERS BC6N Tento výrobek byl vyvinut za finanční podpory ze státních fondů prostřednictvím Ministerstva průmyslu a obchodu. D

BC6N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5, D8 Connecting sets...d8, D9 Mounting sets...d9 Switches...D Shunt trips...d Undervoltage releases...d Hand drives...d Mechanical interlocking and parallel switching...d2 Motor drives...d2 Accessories...D2 Purchase order example...d3 Custom assembly of circuit breakers...d3 TECHNICAL INFORMATION Circuit breakers, switch-disconnectors - specifications...d4 - diagram...d5 - connecting, installation...d7 - deionization space...d2 - dimensions...d22 Overcurrent releases - description, specifications, tripping characteristics...d33 Connecting sets - specifications...d8 Switches - specifications...d36 Shunt trips - specifications...d37 Undervoltage releases - specifications, diagram...d38 Hand drives - description, specifications...d39 Mechanical interlocking and parallel switching - description, specifications, dimensions...d4 Motor drives - description, specifications, diagram...d4 D2

BC6N CONNECTING SETS Double block terminals Output terminals Front connection Rear connection Potential terminals Reduction for BA...*33 CS-BC-B2 CS-BC-B4 CS-BC-A CS-BC-A2 CS-BC-PS CS-BC-A33 HAND DRIVES Front hand drive unit RP-BC-CK2 RP-BC-CP... CIRCUIT BREAKERS Front hand drive unit RP-BC-CK2 RP-BC-CH... RP-BC-CN... BC6NT35-6-L BC6NT35-6-N Right side hand drive unit RP-BC-CK3 SWITCH-DISCONNECTOR BC6NT35-6-D Left side hand drive unit RP-BC-CK3 Mechanical parallel switching RP-BC-CD AUXILIARY RELEASES Shunt trip Undervoltage release SWITCHES Signal switch BC6NT35--M Auxiliary switch BC6NT35-6-V MOUNTING SETS Adapter to install on 35 mm Mechanical interlocking RP-BC-CB SV-BC-X... SP-BC-X... NS-BC- PS-BC- MOTOR DRIVES Motor drive - side ACCESSORIES Lockable lever Terminal cover - IP2 Insulating barriers Reduction for BA...*33 OD-BC-DIN OD-BC-UP OD-BC-KS3 CS-BC-KS2 OD-BC-MS33 D3

BC6N - Commercial information CIRCUIT BREAKERS - Circuit breaker includes: - 2 connecting sets for connecting Cu/Al cables with cross-sections 2.5 95 mm 2 ) (connecting sets are installed in the circuit breaker) - insulating barriers OD-BC-KS2 - installation bolts OD-BC-MS (2 x M3x3) - conductor holder OD-BC-DV - the way of connecting the power circuit must observe recommendations (see page D7) as well as deionization space (see page D2) ) - for connecting in another way one may use connecting sets CS-BC-... (see page D8, D9) Characteristic L - lines protecting lines with low starting currents without I r regulation I n [A] Type Product code I rm [A] Weight [kg] Package [pc] 4 BC6NT35-4-L 224 6. 5 BC6NT35-5-L 226 2. 63 BC6NT35-63-L 228 252. 8 BC6NT35-8-L 222 32. BC6NT35--L 223 4. 25 BC6NT35-25-L 225 5. 6 BC6NT35-6-L 227 64. - TECHNICAL INFORMATION, see page D4, D33 Characteristic D - distribution protecting lines and transformers I n [A] Type Product code Setting I r [A] I rm [A] Weight [kg] Package [pc] 6 BC6NT35-6-D 229 2.5 6 6 24. 2 BC6NT35-2-D 22 6 2 2 3. 25 BC6NT35-25-D 222 2 25 25 375. 32 BC6NT35-32-D 223 25 32 6 32. 4 BC6NT35-4-D 225 32 4 2 4. 5 BC6NT35-5-D 227 4 5 25 5. 63 BC6NT35-63-D 229 5 63 35 63. 8 BC6NT35-8-D 2222 63 8 4 8. BC6NT35--D 224 8 5. 25 BC6NT35-25-D 226 25 625 25. 6 BC6NT35-6-D 228 25 6 8 6. - TECHNICAL INFORMATION, see page D4, D33 Characteristic M - motor motors protection I n [A] Type Product code Setting I r [A] I rm [A] Weight [kg] Package [pc] 6 BC6NT35-6-M 2243 2.5 6 6. 2 BC6NT35-2-M 2244 6 2 2. 25 BC6NT35-25-M 2245 2 25 25. 32 BC6NT35-32-M 2246 25 32 32. 4 BC6NT35-4-M 2247 32 4 4. 5 BC6NT35-5-M 2248 4 5 5. 63 BC6NT35-63-M 2249 5 63 63. 8 BC6NT35-8-M 225 63 8 8. BC6NT35--M 2242 8. - TECHNICAL INFORMATION, see page D4, D33 D4

BC6N - Commercial information CIRCUIT BREAKERS Characteristic N - short-circuit release only I n [A] Type Product code I r [A] I rm [A] Weight [kg] Package [pc] 32 BC6NT35-32-N 264-6 32. 4 BC6NT35-4-N 2642-2 4. 5 BC6NT35-5-N 2643-25 5. 63 BC6NT35-63-N 2644-35 63. 8 BC6NT35-8-N 2645-4 8. BC6NT35--N 2646-5. 25 BC6NT35-25-N 2647-625 25. 6 BC6NT35-6-N 262-8 6. - TECHNICAL INFORMATION, see page D4, D33 SWITCH-DISCONNECTOR - Switch-disconnector includes: - 2 connecting sets for connecting Cu/Al cables with cross-sections 2.5 95 mm 2 ) (connecting sets are installed in the switch-disconnector) - insulating barriers OD-BC-KS2 - installation bolts OD-BC-MS (2 x M3x3) - conductor holder OD-BC-DV ) - for connecting in another way, one may use connecting sets CS-BC-... see page D8, D9 I e [A] Type Product code Weight [kg] Package [pc] 6 BC6NT35-6-V 2585. - TECHNICAL INFORMATION, see page D4 D5

BC6N - Commercial information CIRCUIT BREAKERS +N - Circuit breaker includes: - connecting terminals for connecting Cu/Al cables with cross-sections 2.5 95 mm 2 ) (connecting terminals are installed in the circuit breaker) - insulating barriers OD-BC-KS2 and OD-BC-KS42-2 installation bolts OD-BC-MS (4 x M3x3) - conductor holder OD-BC-DV (it is installed in the circuit breaker) - the way of connecting the power circuit must observe recommendations (see page D7) as well as deionization space (see page D2) ) - for connecting in another way, it is necessary to use connecting sets CS-BC-... see page D8, D9 Characteristic L - lines protecting lines with low starting currents without I r regulation + N - for unprotected N conductor I n [A] Type Product code Setting I r [A] I rm [A] Weight [kg] Package [pc] 4 BC6NT45-4-L 3362-6.3 5 BC6NT45-5-L 336-2.3 63 BC6NT45-63-L 3368-252.3 8 BC6NT45-8-L 3366-32.3 BC6NT45--L 3364-4.3 25 BC6NT45-25-L 3362-5.3 6 BC6NT45-6-L 336-64.3 - TECHNICAL INFORMATION, see page D4, D33 Characteristic D - distribution + N - for unprotected N conductor protecting lines and transformers I n [A] Type Product code Setting I r [A] I rm [A] Weight [kg] Package [pc] 6 BC6NT45-6-D 3367 2.5 6 6 24.3 2 BC6NT45-2-D 3366 6 2 2 3.3 25 BC6NT45-25-D 3365 2 25 25 375.3 32 BC6NT45-32-D 3364 25 32 6 32.3 4 BC6NT45-4-D 3363 32 4 2 4.3 5 BC6NT45-5-D 336 4 5 25 5.3 63 BC6NT45-63-D 3369 5 63 35 63.3 8 BC6NT45-8-D 3367 63 8 4 8.3 BC6NT45--D 3365 8 5.3 25 BC6NT45-25-D 3363 25 625 25.3 6 BC6NT45-6-D 336 25 6 8 6.3 - TECHNICAL INFORMATION, see page D4, D33 Characteristic N - short-circuit release only + N - for unprotected N conductor without I r regulation I n [A] Type Product code Setting I r [A] I rm [A] Weight [kg] Package [pc] 32 BC6NT45-32-N 33625-6 32.3 4 BC6NT45-4-N 33624-2 4.3 5 BC6NT45-5-N 33623-25 5.3 63 BC6NT45-63-N 33622-35 63.3 8 BC6NT45-8-N 3362-4 8.3 BC6NT45--N 3362-5.3 25 BC6NT45-25-N 3369-625 25.3 6 BC6NT45-6-N 3368-8 6.3 - TECHNICAL INFORMATION, see page D4, D33 D6

BC6N - Commercial information CIRCUIT BREAKERS - Circuit breaker includes: - connecting terminals for connecting Cu/Al cables with cross-sections 2.5 95 mm 2 ) (connecting terminals are installed in the circuit breaker) - insulating barriers OD-BC-KS2 and OD-BC-KS42-2 installation bolts OD-BC-MS (4 x M3x3) - conductor holder OD-BC-DV (it is installed in the circuit breaker) - the way of connecting the power circuit must observe recommendations (see page D7) as well as deionization space (see page D2) ) - for connecting in another way, it is necessary to use connecting sets CS-BC-... see page D8, D9 Characteristic L - lines protecting lines with low starting currents without I r regulation - for protected N conductor I n [A] Type Product code Setting I r [A] I rm [A] Weight [kg] Package [pc] 4 BC6NT46-4-L 33639-6.3 5 BC6NT46-5-L 33637-2.3 63 BC6NT46-63-L 33635-252.3 8 BC6NT46-8-L 33633-32.3 BC6NT46--L 3363-4.3 25 BC6NT46-25-L 33629-5.3 6 BC6NT46-6-L 33627-64.3 - TECHNICAL INFORMATION, see page D4, D33 Characteristic D - distribution - for protected N conductor protecting lines and transformers I n [A] Type Product code Setting I r [A] I rm [A] Weight [kg] Package [pc] 6 BC6NT46-6-D 33644 2.5 6 6 24.3 2 BC6NT46-2-D 33643 6 2 2 3.3 25 BC6NT46-25-D 33642 2 25 25 375.3 32 BC6NT46-32-D 3364 25 32 6 32.3 4 BC6NT46-4-D 3364 32 4 2 4.3 5 BC6NT46-5-D 33638 4 5 25 5.3 63 BC6NT46-63-D 33636 5 63 35 63.3 8 BC6NT46-8-D 33634 63 8 4 8.3 BC6NT46--D 33632 8 5.3 25 BC6NT46-25-D 3363 25 625 25.3 6 BC6NT46-6-D 33628 25 6 8 6.3 - TECHNICAL INFORMATION, see page D4, D33 Characteristic N - short-circuit release only - for protected N conductor without I r regulation I n [A] Type Product code Setting I r [A] I rm [A] Weight [kg] Package [pc] 32 BC6NT46-32-N 33652-6 32.3 4 BC6NT46-4-N 3365-2 4.3 5 BC6NT46-5-N 3365-25 5.3 63 BC6NT46-63-N 33649-35 63.3 8 BC6NT46-8-N 33648-4 8.3 BC6NT46--N 33647-5.3 25 BC6NT46-25-N 33646-625 25.3 6 BC6NT46-6-N 33645-8 6.3 - TECHNICAL INFORMATION, see page D4, D33 D7

BC6N - Commercial information SWITCH-DISCONNECTOR - Switch-disconnector includes: - 2 connecting sets for connecting Cu/Al cables with cross-sections 2.5 95 mm 2 ) (connecting sets are installed in the switch-disconnector) - insulating barriers OD-BC-KS2 and OD-BC-KS42-2 installation bolts OD-BC-MS (4 x M3x3) - conductor holder OD-BC-DV (it is installed in the switch-disconnector) ) - for connecting in another way, one may use connecting sets CS-BC-... see page D8, D9 I e [A] Type Product code Weight [kg] Package [pc] 6 BC6NT45-6-V 33626.3 - TECHNICAL INFORMATION, see page D4 CONNECTING SETS 3 terminals Type Product code Description S [mm 2 ] Method of connection Weight [kg] Package [set] ) CS-BC-A 2223 Front connection Cu/Al busbars, cable lugs.45 - TECHNICAL INFORMATION, see page D8 CS-BC-B2 2237 Block terminal - double - TECHNICAL INFORMATION, see page D8 - terminals cover included - protection IP2 2 x 25 2 Cu/Al cables.8 CS-BC-A2 2236 Rear connection Cu/Al busbars, cable lugs.75 - TECHNICAL INFORMATION, see page D8 CS-BC-PS 2239 Potential terminals.5 2.5; 4 6 Cu flexible conductor. - TECHNICAL INFORMATION, see page D8 CS-BC-B4 34957 Block terminals - for 5 cables - TECHNICAL INFORMATION, see page D8 - terminals cover included - protection IP2 5x(2.5 25) Cu/Al cables.8 RETROFIT CS-BC-A33 268 Reduction for BA *33 Cu/Al busbars, cable lugs.3 - TECHNICAL INFORMATION, see page D8 - for total replacement of BA *33 circuit breaker, also necessary is the OD-BC-MS33 mounting set ) - one set provides for connecting one side of the circuit breaker (set includes three terminals with necessary coupling elements) D8

BC6N - Commercial information CONNECTING SETS terminal Type Product code Description S [mm 2 ] Method of connection Weight [kg] Package [set] ) CS-BC-A4 33653 Front connection Cu/Al busbars, cable lugs.5 - TECHNICAL INFORMATION, see page D8 CS-BC-A42 33654 Rear connection Cu/Al busbars, cable lugs.8 - TECHNICAL INFORMATION, see page D8 CS-BC-B42 33658 Block terminal - double - TECHNICAL INFORMATION, see page D8 - terminals cover included - protection IP2 2x(25 2) Cu/Al cables.25 CS-BC-B44 34958 Block terminal - for 5 cables - TECHNICAL INFORMATION, see page D8 - terminals cover included - protection IP2 5x(2.5 25) Cu/Al cables.24 CS-BC-PS4 363 Potential terminals.5 2.5/4 6 Cu flexible conductor.5 - TECHNICAL INFORMATION, see page D8 MOUNTING SETS RETROFIT Type Product code Description Weight [kg] Package [set] 2) OD-BC-MS33 2625 Reduction for BA *33.25 - for total replacement of BA *33 circuit breaker, also necessary are two CS-BC-A33 connecting sets OD-BC-DIN 2238 For mounting on 35 mm DIN rail.5 - DIMENSIONS see page D26 2) - one set provides for replacing one circuit breaker (set includes coupling elements necessary to assemble circuit breaker and mounting set) RETROFIT - sets enabling replacement of old circuit breakers with new ones while not requiring switchboard modifications D9

BC6N - Commercial information SWITCHES Auxiliary - signal state of the main contacts Type Product code Operating voltage Contacts Weight [kg] Package [pc] PS-BC- 2227 6 25 V a.c./d.c.. PS-BC--Au 2228 5 6 V a.c./d.c.. - TECHNICAL INFORMATION, see page D36 Signal - signal tripping of circuit breaker by overcurrent release Type Product code Operating voltage Contacts Weight [kg] Package [pc] NS-BC- 2225 6 25 V a.c./d.c.. NS-BC--Au 2226 5 6 V a.c./d.c.. - TECHNICAL INFORMATION, see page D36 SHUNT TRIPS Type Product code Operating voltage Weight [kg] Package [pc] SV-BC-X24 2233 24, 48 V a.c./d.c..5 SV-BC-X 2234, 23 V a.c./, 22 V d.c..5 SV-BC-X23 2235 23, 4 V a.c./ 22 V d.c..5 - TECHNICAL INFORMATION, see page D37 UNDERVOLTAGE RELEASES Type Product code Operating voltage Weight [kg] Package [pc] SP-BC-X24 2229 24, 48 V a.c./d.c..5 SP-BC-X 223, 23 V a.c./, 22 V d.c..5 SP-BC-X23 2232 23, 4 V a.c./ 22 V d.c..5 - TECHNICAL INFORMATION, see page D38 D

HAND DRIVES BC6N - Commercial information Type Product code Name - description Weight [kg] Package [pc] RP-BC-CK 256 Hand drive unit - no locking.79 RP-BC-CK2 2593 Hand drive unit - lockable.79 - TECHNICAL INFORMATION, see page D39 Hand drive unit must be fitted with: for controlling on switching unit - hand drive lever RP-BC-CP.. for controlling on switchboard door - extension shaft RP-BC-CH.. - hand drive bearing RP-BC-CN.. - hand drive lever RP-BC-CP.. RP-BC-CK2 2594 Hand drive unit - lockable.79 - yellow - TECHNICAL INFORMATION, see page D39 Hand drive unit must be fitted with: for controlling on circuit breaker - hand drive lever RP-BC-CP.. for controlling on switchboard door - extension shaft RP-BC-CH.. - hand drive bearing RP-BC-CN.. - hand drive lever RP-BC-CP.. RP-BC-CK3 2595 Hand drive unit for - no locking.37 controlling on right side RP-BC-CK3 2596 Hand drive unit for controlling on left side - no locking.37 - TECHNICAL INFORMATION, see page D39 Hand drive unit must be fitted with: extension shaft RP-BC-CH.., hand drive bearing RP-BC-CN.., hand drive lever RP-BC-CP.. RP-BC-CP 256 Hand drive lever - black RP-BC-CP2 2562 Hand drive lever - black - TECHNICAL INFORMATION, see page D39 - no locking.9 - lockable.9 RP-BC-CP2 2597 Hand drive lever - red - TECHNICAL INFORMATION, see page D39 - lockable.9 RP-BC-CN 2564 Hand drive bearing - protection IP4.42 RP-BC-CN2 2565 Hand drive bearing - protection IP66.42 - TECHNICAL INFORMATION, see page D39 - used in combination with black hand drive lever RP-BC-CP or RP-BC-CP2 RP-BC-CN 2598 Hand drive bearing - yellow RP-BC-CN2 2599 Hand drive bearing - yellow - TECHNICAL INFORMATION, see page D39 - Used in combination with red hand drive lever RP-BC-CP2 - protection IP4.42 - protection IP66.42 RP-BC-CH 2563 Extension shaft - length 35 mm.3 - TECHNICAL INFORMATION, see page D39 RP-BC-CH2 26 Extension shaft - telescopic, lenght 99 352 mm.92 - TECHNICAL INFORMATION, see page D39 D

BC6N - Commercial information MECHANICAL INTERLOCKING AND PARALLEL SWITCHING Type Product code Name Weight [kg] Package [pc] RP-BC-CB 26 Mechanical interlocking.89 - TECHNICAL INFORMATION, see page D4 - Mechanical interlocking must be fitted with: 2 hand drive units RP-BC-CK.. (cannot be combined with hand drive unit for side control) 2 hand drive levers RP-BC-CP.. RP-BC-CD 262 Mechanical parallel switching.9 - TECHNICAL INFORMATION, see page D4 - Mechanical parallel switching must be fitted with: 2 hand drive units RP-BC-CK.. (cannot be combined with hand drive unit for side control) hand drive lever RP-BC-CP.. MOTOR DRIVES Type Product code Name Weight [kg] Package [pc] MP-BC-X24-B 3445 Motor drive side, 24 V a.c./d.c..9 MP-BC-X48-B 3445 Motor drive side, 48 V a.c./d.c..9 MP-BC-X-B 34452 Motor drive side, V a.c./d.c..9 MP-BC-X23-B 34453 Motor drive side, 23 V a.c./d.c..9 - TECHNICAL INFORMATION, see page D4 ACCESSORIES Type Product code Name - description Weight [kg] Package [pc] OD-BC-KS2 2224 Insulating barriers - set (two pieces), for and design.3 OD-BC-KS42 3366 Insulating barrier - one piece, for design.5 - Included with each circuit breaker or switch-disconnector order - In case connection is reversed (supply to terminals 2, 4, 6) it is necessary to install these barriers also on the lower side. For more information, see page D2 OD-BC-KS3 224 Terminal cover - protection IP2, for 3-pole design.5 OD-BC-KS43 3366 Terminal cover - protection IP2, for 4-pole design.7 - Increases degree of protection of connection point to IP2, e.g. when used with cable lugs OD-BC-UP 224 Locking-type lever - Enables locking of circuit breaker or switch-disconnector in switched off manually position - Locking is possible using padlock with shank diameter up to 3 4 mm OD-BC-KA2 34454 Connecting cable, 6 cm for motor drive. D2

BC6N - Technical information PURCHASE ORDER EXAMPLE BC6NT35-8-D Insulating barriers You need a circuit breaker for protecting lines with a total rated current of 75 A. Starting currents may exceed four times I n. Maximum short-circuit current in the circuit will not exceed 7 ka. Your purchase order: (Do not enter text from grey area into your purchase order) The circuit breaker will be situated in a switchboard cabinet. Incoming feeders will be Al cables with cross-section 35 mm 2 and outgoing will be Cu cables with cross-section 25 mm 2. Connecting sets Conductor holder NUMBER TYPE PRODUCT CODE pc BC6NT35-8-D 2222 - circuit breaker with rated current 8 A for protecting lines, regulation of rated current 63 8 A, rated ultimate short-circuit breaking capacity 25 ka - switching unit consists of: 2 connecting sets for connecting Cu/Al cables with cross-section up to 2.5 95 mm 2 insulating barriers (OD-BC-KS2) mounting bolts set for installing circuit breaker (OD-BC-DV) conductor holder (OD-BC-DV) Mounting bolts set Connecting sets CUSTOM ASSEMBLY OF CIRCUIT BREAKERS at customer s request warranty not only for components but for entire configuration in consultation with OEZ, configured according to your specifications delivery in - 4 weeks extra charge for assembly and special packing Your order should include the following specifications: type and setting of the overcurrent release connecting terminal types - for your circuit breaker s input terminals - for your circuit breaker s output terminals installation requirements, type and function of switches installation requirements and type of auxiliary releases, including rated voltage requirements for fitting circuit breaker with drive - type of hand drive, including accessories (operating lever, bearing, shaft) required withdrawable or plug-in design circuit breakers requirements for fitting withdrawable device with signalling of individual positions requirement for sealing the overcurrent release D3

CIRCUIT BREAKERS, SWITCH-DISCONNECTORS BC6N - Technical information Specifications CIRCUIT BREAKER SWITCH-DISCONNECTOR Type BC6NT.. BC6NT...-V Series NORMAL Dimensions A x B x C + D (/ design) 75/ x 6 x 7 + 23 mm 75/ x 6 x 7 + 23 mm Weight (/ design) /.3 kg /.3 kg Standards EN 6 947-2, IEC 947-2 EN 6 947-3, IEC 947-3 Approval marks D4 Wiring of circuit breaker in DC circuit up to 44 V d.c. Circuit breaker Switch-disconnector Dimensions Installation positions Wiring of circuit breaker in DC circuit up to 25 V d.c. Number of poles 3, 4 3, 4 Rated current I n 6 6 A 2) - Rated normal current I u 6 6 A 2) 6 A Rated operating current I e - 6 A Rated operating voltage U e max. 69 V a.c. max. 25 V d.c. () max. 44 V d.c. () max. 69 V a.c. max. 25 V d.c. () max. 44 V d.c. () Rated frequency f n 5/6 Hz 5/6 Hz Rated pulse withstand voltage U imp 8 kv 8 kv Rated insulation voltage U i 69 V 69 V Utilization category (selectivity) 69 V a.c. A - Utilization category (switching mode) AC-3 (6 A) AC-2 (25 6 A) DC-22A AC-23 A DC-22A Rated short-time withstand current I cw / t - 2 ka/ s Rated short-circuit ultimate breaking capacity I cu / U e 6 ka/ 69 V a.c. (rms value) ) 2 ka/ 5 V a.c. 25 ka/ 45 V a.c. 4 ka/ 23 V a.c. - 25 ka/25 V d.c. τ = max. 5 ms () 2 KA/44 V d.c. τ =max. 5ms () Off-time at I cu 7 ms - Rated short-circuit service breaking capacity (rms value) I cs / U e 3 ka/ 69 V a.c. 6 ka/ 5 V a.c. 3 ka/ 45 V a.c. 2 ka/ 23 V a.c. - 3 ka/25 V d.c. τ = max. 5 ms () 3 ka/44 V d.c. τ = max. 5ms () I cm / U e 52 ka/ 45 V a.c. 2.8 ka/ 45 V a.c. Rated short-circuit making capacity (peak value) Losses per pole at I n = 6 A 5 W 5 W Mechanical endurance 2 cycles 2 cycles Electrical endurance (U e = 45 V a.c.) 6 cycles 6 cycles Frequency of switching 2 cycles/hr 2 cycles/hr Operating force (/ design) 55/65 N 55/65 N Front-side device protection IP4 IP4 Terminals protection IP2 IP2 Operating conditions Reference ambient temperature 4 C 4 C Ambient temperature range -4 C +55 C -4 C +55 C Working environment dry and tropical climate dry and tropical climate Pollution degre 3 3 Max. elevation 2 m 2 m Seismic resistance 3g ( 8 5 ) Hz 3g ( 8 5 ) Hz Design modifications Front/rear connection / / Plug-in design Withdrawable design Accessories Switches - auxiliary / relative / signal / early / / / / / / Shunt trip / with signal switch / / Undervoltage release / with early switch / with signal switch / / / / Front hand drive / side drive right / left / / / / Mechanical interlocking - with Bowden cable / for manual drive / / Motor drive / with cycle counter / / Lockable lever available, unavailable, + being prepared ) - In case circuit breaker connection is reversed (input terminals 2, 4, 6, output terminals, 3, 5) I cu does not change 2) - Ranges of rated currents vary according to characteristics, see page D33

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Specifications Power losses (per pole) I n [A] P [W] 6 4 2 4 25 4 32 4 4 4 5 5 63 6 8 7 25 5 6 5 TEST push button Description of push button functions and signalling TEST push button - by pressing you will switch off the circuit breaker/switch-disconnector, including to actuate the auxiliary switches. INSPECTION push button - by pressing you will simulate tripping of the circuit breaker by the overcurrent release, including to actuate the auxiliary switches and signal switch. Pressing requires a suitable instrument, such as a wire with cross-section of about mm. Signalling of switching off by the overcurrent release - after switching off of the circuit breaker by the overcurrent release, it will display the indicator Diagram Circuit breaker with accessories (3-pole design).y Pomocné Switches spouště A.Y B nebo or Auxiliary Spínače releases Hlavní Primary obvod circuit Switches Spínače pomocný auxiliary pomocný auxiliary pomocný auxiliary návěstní signal nebo or auxiliary pomocný pomocný auxiliary pomocný auxiliary 6. 2 6. 4 5. 2 5. 4 INSPECTION push button 4. 2 4.4 3 5 Signals switching off by the overcurrent release - signalling is for circuit breakers with characteristic D, M and N. 2. 4.2. 4 2.2 2. 4 3.2 3. 4 TEST SP-BC-... SV -BC-... Q V or I> N INSPECTION REVIZE J 2 4 6.Y2 A2.Y2 B2 6. 6.PS-BC- 5. 5.PS-BC- 4. 4.PS-BC-..PS-BC- 2. 2.PS-BC- cavity dutina No. č. dutina cavity No.6 č.6 dutina cavity No.5 č.5 dutina cavity No.4 č.4 cavity dutina No.č. cavity dutina No.2 č.2 dutina cavity No.3 č.3..ns-bc- or 3. 3.PS-BC- J Q V N TEST REVIZE SP-BC-X SV-BC-X circuit breaker main contacts trip free mechanism overcurrent release TEST push button INSPECTION push button undervoltage release shunt trip D5

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Diagram Description of diagram Circuit breaker with accessories (4-pole design) MP motor drive - MP-BC... M motor P gear unit Ovládací Control circuit obvod MP X3 connector to connect control circuits and signalling Q3 B recommended wiring of the control circuits L+ - not included with drive ON push button OFF push button ON Q3 motor drive circuit breaker - see page D42 OFF J circuit breaker BC6 Q main contacts B T thermomagnetic overcurrent release +N (3 poles are protected, N pole is unprotected) Motorový pohon Spínače ínaıe (all 4 poles are protected) drive Switches pomocný auxiliary pomocný auxiliary pomocný auxiliary V trip-free mechanism TEST push button to test release X3 SV-BC-X shunt trip HL signalling of failure (unreliable switching on or switching off), permissible load max. W ) HL2 signalling of circuit breaker lever position loaded, permissible load max. W ) 4 3 REVIZE inspection push button SP-BC-X undervoltage release M P 9. 2 9. 4 8. 2 8. 4 7. 2 7. 4 A HL3 signalling of opening of the front safety cover of the drive, permissible load max. W ) HL4 signalling of the extension of the drive locking bar, permissible load max. W ) ) voltage on terminals 6, 7, 8 is the same as U n of the motor drive MP 9.PS-BC- 8.PS-BC- 7.PS-BC- X3 2 5 6 7 8 J 9. 8. 7. dutina cavity č.9 No.9 cavity dutina No.8 č.8 cavity dutina No.7 č.7 HL HL 2 HL 3 HL 4 N - B Ovládací obvod Control MP, signalizace circuit MP, signalling pomo auxiliary cn ý 6. 2 6. 4 Spínače Switches pomo auxiliary cn ý 5. 2 5. 4 nebo or Pomocné Auxiliary spouštěče releases Primary Hlavní obvod circuit Switches Spínače pomo auxiliary cn ý návěstní signal nebo or auxiliary pomocný pomocný auxiliary auxiliary pomocný 4. 2 4. 4.Y A.Y B N 3 5. 2. 4. 2. 4 2. 2 2. 4 3. 2 3. 4 TEST A SP-BC-... or SV -BC-... Q V J 6. 6.PS-BC- 5. 5.PS-BC- 4. 4.PS-BC-.Y2 A2.Y2 B2 I> T N 2 4 6 INSPECTION REVIZE..NS-BC- or..ps-bc- 2. 2.PS-BC- 3. 3.PS-BC- cavity dutina No.6 č.6 cavity dutina No.5 č.5 cavity dutina No.4 č.4 cavity dutina No. č. cavity dutina No. č. cavity dutina No.2 č.2 cavity dutina No.3 č.3 D6

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Specifications States of switches in circuit breaker/switch-disconnector Cavity, 2, 3, 4, 5, 6 (7, 8, 9) * Circuit breaker state Lever position of circuit breaker State of the main contacts PS-BC- NS-BC- SV-BC-X... SP-BC-X... Switched on Switched off manually (loaded state) Switched off by the overcurrent release or INSPECTION push button Switched off by auxiliary release Switched off by TEST push button note: - contact open, - contact closed * only design Connecting and installation Power circuit Is connected using Cu or Al busbars or cables, and possibly cables with cable lugs. Connection sets are produced to provide greater connecting options see page D6 Generally, conductors from the supply are connected to input terminals, 3, 5 and conductors from the load to terminals 2, 4, 6. But it is possible to reverse the connection (exchanging input and output terminals without limiting rated short-circuit ultimate breaking capacity I cu ) In case of reversed connection, in the majority of cases, circuit breaker/switch-disconnector must be fitted with OD-BHD-KS2 insulating barriers also on the side of terminals 2, 4, 6 (see page D2 for detailed information). Recommended cross-sections of cables, busbars and flexibars We recommend painting the connecting busbars Input and output conductors/busbars must be mechanically reinforced in order to avoid transferring electrodynamic forces to the circuit breaker during short circuiting. The way of connecting the power circuit must observe the deionization space of the circuit breaker/switch-disconnector see page D2 Auxiliary circuits Switches, shunt trips or undervoltage releases are connected using flexible Cu conductors with cross-section.5 mm 2 directly to terminals on these devices. I n [A] Cables S [mm 2 ] Busbars W x H [mm] Cu Al Cu Al 6 2.5 - - - 2 2.5 - - - 25 4 - - - 32 6 - - - 4 - - - 5 6 - - 63 6 25 - - 8 25 35 - - 35 5 6 x 2; 2 x 3 6 x 4; 2 x 5 25 5 7 6 x 4; 2 x 5 6 x 5; 2 x 6 6 7 95 6 x 5; 2 x 6 6 x 6; 2 x 8 Location of cavities in BC6NT circuit breaker/switch-disconnector. When using one of cavities 4, 5 or 6, neither a shunt trip nor an undervoltage release should be used.. 9 8 7 6 5 4 2 3 Location of cavities in BC6NT4... circuit breaker or switch-disconnector. When one of cavities 4, 5 or 6 is in use, cannot be used with a shunt trip or undervoltage release. Mechanical reinforcement of conductors for BC6 D7

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Connecting and installation Parameters of connection sets Type I max [A] Cable - ranges of connection cross-sections S [mm 2 ] Type of cable sector stranded sector solid round stranded round solid Busbars and cable lugs W x H [mm] Technical information CS-BC-B2 6 2x (25 2) 2x (25 2) 2x (25 2) 2x (25 2) page D2, D22 CS-BC-B42 6 2x (25 2) 2x (25 2) 2x (25 2) 2x (25 2) page D27 CS-BC-A 6 6 x page D2 CS-BC-A4 6 CS-BC-A2 6 6 x page D9, D23 CS-BC-A42 6 page D28 CS-BC-PS /6.5 2.5 / 4 6 CS-BC-PS4 /6.5 2.5/4 6 CS-BC-A33 6 RETROFIT - reduction for BA *33 circuit breaker with front connection 3 x page D2, D23 CS-BC-B4 6 5x (2.5 25) 5x (2.5 25) 5x (2.5 25) 5x (2.5 25) CS-BC-B44 6 5x (2.5 25) 5x (2.5 25) 5x (2.5 25) 5x (2.5 25) RETROFIT - sets, which allow replacement of older circuit breakers by a new circuit breakers without switchboard reconstruction D8

8 BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Connecting and installation Front connection - Cu/Al cables, busbars (connecting set is a part of circuit breaker/switch disconnector). 3. 4. 5. 2,5 6mm 2 Al, Cu... 4 N m 4 25 9mm 2 Al, Cu... 6 N m 4 2. 2 (max. 3) 7 Front connection - Cu/Al busbars Rear connection - Cu/Al busbars 3. 6,4 2. CS-BC-A 3. 8 6.. 2. CS-BC-A2 5. 6. 7. 5. 8 N m... 5 4. 6 (max. 7) 4. 8 N m... 5 D9

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Connecting and installation Front connection - 2 x Cu/Al cables Front connection - cable lugs CS-BC-B2. 3. 5. 2. CS-BC-A 7. 6. or ode r èëè leb o nebo 5. OD-BC-KS3 IP2. 8. 6 N m... 4 2. 7. 6.. 25 7mm 2 Al,Cu... Nm 5 95 2mm 2 Al,Cu... 5 Nm 5 4. Front connection - reduction to BA...*33 CS-BC-A33. 3. 4. 5. 2. 6 N m... 4 CS-BC-A33 37,5 37,5 3 6 83 9 22 35 22 8. 8 N m... 5 4. 7 3.,5 D2

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Deionization space C=2 B=75 B=75 B= C=2 OD-BC-KS2 H E=7 G=4 Un > 4 V a.c. D=2 3 A A A2 F= G= Un 4 V a.c. H >5 A minimum distance between the circuit breaker/ switch-disconnector and uninsulated earthed wall (applicable for connections using insulated conductors, cables, flexibars or with rear connection) A minimum insulation length of bare conductors (using OD-BC-KS2 and OD-BC-KS42 insulating barriers from 5 mm to max. mm, or by adding additional insulation for the conductors with barriers to obtain at least A value) Reference A A A2 H Size 5 mm mm 5 mm 3 mm A2 minimum distance: - between the circuit breaker/switch-disconnector and uninsulated earthed wall (applicable for uninsulated conductors and busbars) - between the circuit breaker/switch-disconnector and busbar - between two circuit breakers/switch-disconnectors situated vertically above one another - between uninsulated connections of two circuit breakers/switch-disconnectors above one another C, D, E, F, G minimum distance between the circuit breaker/switch-disconnector and uninsulated earthed wall H minimum distance between uninsulated conductors USE OF INSULATING BARRIERS AND TERMINAL COVERS WITH CIRCUIT BREAKERS AND SWITCH-DISCONNECTORS FIXED DESIGN - front connection - terminals N,, 3, 5 - It is always necessary to use OD-BC-KS2 and OD-BC-KS42 insulating barriers or a OD-BHD-KS3 and OD-BHD-KS43 terminal cover (when using CS-BC-B42 connections sets for connecting circuit breaker/ switch-disconnector, the terminal cover is included in the connecting set). - terminals N, 2, 4, 6 - It is always necessary to use OD-BC-KS2 and OD-BC-KS42 insulating barriers or a OD-BC-KS43 terminal cover if the circuit breaker/switch-disconnector is connected to the source using terminals 2, 4, 6 (when using CS-BC-B42 connections sets for connecting circuit breaker/switch-disconnector, the terminal cover is included in the connecting set). - rear connection - Insulating barriers and covers need not be used D2

2 BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, front connection Drilling position ø6.4 8 2.5 93 7 25 8 3 98 68.5 2 2 38 4 3 63 4.5 45 R54.6 ø4x4 5 25 25 75 2 7 8 25 25 Fixed design, front connection (connecting set CS-BC-B2) 25 25 3 68.5 2 25 22 86 54 22 36 68 75 2xø6.2 D22

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, rear connection (connecting set CS-BC-A2) Drilling position 3 25 25 25 75 9.5 2 ø3.2 87 8 ø6.4 3 42 35 7 2 5.5 25 25 25 ø5 ø2x4 3 Fixed design, front connection (connecting set CS-BC-A33) RETROFIT - reduction for circuit breaker BA...*33 37.5 37.5 25 22 4 25 83 75 36.5 3 ø.5 2 2 D23

ø37 BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, front hand drive 75 BC6... RP-BC-CK.. RP-BC-CP.. 63 22.5 22.5 27.5 45 9 98 29 Fixed design, front hand drive with adjustable lever 75 BC6... RP-BC-CK.. RP-BC-CP.. RP-BC-CN.. 45 RP-BC-CH.. 63 45 22.5 22.5 SWITCHBOARD PANEL ROZVÁD E PANEL 27.5 45 9 98 24-448 (CH) 297-45 (CH2) Switchboard door adaptation min.5 ø6 32 32 D24

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, side hand drive - right PANEL SWITCHBOARD ROZVÁD E PANEL 9 RP-BC-CK3 RP-BC-CN.. 45 RP-BC-CH.. 63 45 BC6... RP-BC-CP.. 26.6 45.5-369.5 (CH) 28.5-37.5 (CH2) 5 4.5 Fixed design, side hand drive - left Switchboard modification RP-BC-CN.. 75 ø37 RP-BC-CP.. SWITCHBOARD PANEL ROZVÁD E PANEL 32 RP-BC-CK3 45 ø6 32 RP-BC-CH.. 63 BC6... 45 9 49.9 46.6 65.5-389.5 (CH) 238.5-39.5 (CH2) 4.5 Fixed design, circuit breaker with mechanical interlocking RP-BC-CB 2.5 or 25 48.2 D25

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, circuit breaker with mechanical parallel switching RP-BC-CD 48.2 +7 or 2.5 +7 or 25 +7 Fixed design, installation on 35 mm DIN rail 86 2.7 4.5 45 3 67 2 72 82 Fixed design, motor drive 94.4 5 8 7 45.4 4.5 3 45 2 32.8 39.2 2 D26

2 BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, front connection Drilling position ø6.4 8 2.5 25 25 25 Fixed design, front connection (connecting set CS-BC-B42) 25 25 25 25 22 86 54 22 93 8 3 7 98 68.5 2 2 38 4 5 63 45 3 R54.6 M3 4.5 2 7 8 5 25 68.5 3 2 36 68 2xø6.2 D27

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, rear connection (connecting set CS-BC-A42) Drilling position 25 25 25 25 25 25 5.5 25 ø3.2 87 3 42 ø5 25 3 3 8 2 M3 9.5 ø6.4 35 7 2 Fixed design, front hand drive 75 BC6... RP-BC-CK.. RP-BC-CP.. 63 22.5 22.5 52.5 45 9 98 29 D28

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, front hand drive with adjustable lever BC6... RP-BC-CK.. RP-BC-CP.. RP-BC-CN.. 45 RP-BC-CH.. 63 45 22.5 22.5 SWITCHBOARD PANEL ROZVÁDĚČE PANEL 52.5 45 9 98 24-448 (CH) 297-45 (CH2) Switchboard door adaptation min.5 ø37 ø6 32 32 D29

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, side hand drive - right SWITCHBOARD PANEL ROZVÁDĚČE PANEL 9 RP-BC-CK3 RP-BC-CN.. 45 45 RP-BC-CH.. 63 BC6... RP-BC-CP.. 62.5 26.6 49.9 4.5 45.5-369.5 (CH) 28.5-37.5 (CH2) Fixed design, side hand drive - left SWITCHBOARD PANEL ROZVÁDĚČE PANEL RP-BC-CN.. RP-BC-CP.. RP-BC-CK3 45 RP-BC-CH.. 63 BC6... 45 9 49.9 46.6 37.5 4.5 65.5-389.5 (CH) 238.5-39.5 (CH2) Switchboard modification ø37 32 ø6 32 D3

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, installation on 35 mm DIN rail 86 2.7 4.5 45 3 67 2 72 82 Fixed design, circuit breaker with mechanical interlocking RP-BC-CB 48.2 Fixed design, circuit breaker with mechanical parallel switching RP-BC-CD max.6 min. 48.2 D3

BC6N - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, motor drive 94.4 75 8 7 45.4 4.5 3 45 2 32.8 39.2 2 D32

BC6N - Technical information OVERCURRENT RELEASES Overcurrent release is built into circuit breaker. Release cannot be demounted and exchanged. 4-pole circuit breakers are produced in variants: +N (3 poles are protected, N pole is unprotected) (all 4 poles are protected) Permissible strength of N pole is % I n. Tripping characteristics Circuit breakers are supplied with four types of tripping characteristics. They are designated with the letters: L - lines (, +N, ) - protecting lines with low starting currents D - distribution (, +N, ) - protecting lines and transformers M - motor (, +N, ) - motors protection N - short-circuit release only (, ) BC6N circuit breakers with characteristic L have a given and fixed rated current value. The circuit breakers are produced with In values in a standardised series of currents from 4 A to 6 A (see table). Short-circuit release is fixed at 4 x I n. BC6 circuit breakers with characteristic D have the option of setting to a reduced current in a range of approximately.75 I n. The circuit breakers are produced with I n values in a standardised series of currents from 6 A to 6 A (see table). Short-circuit release is adjustable. Adjustment values are given in the table. BC6N circuit breakers with characteristic M have the option of setting to a reduced current in a range of approximately.75 I n. The circuit breakers are produced with In values in a standardised series of currents from 6 A to A (see table). Short-circuit release is fixed at the setting x I n. Circuit breakers are not produced in 4-pole design. BC6N circuit breakers with characteristic N have only short-circuit release. They are produced with I n values in a standardised series of currents from 32 A to 6 A. Short-circuit release is adjustable. Values are given in the table. Circuit breaker designation is set according to the requested rated current and protection characteristics. For example: Motor protection with I n = 32 A. Type designation will be BC6NT35-32M. Setting of tripping characteristic: Dependent release (thermal) L (for circuit breakers with characteristics D and M ). Dependent release (reduced current value I r ), is adjusted in a continuous range using the I r adjustment dial on the overcurrent release. The I r adjustment range is.75 I I n. Independent instantaneous release (short-circuit trip) I (for circuit breakers with characteristics D and N ). With an independent instantaneous release (short-circuit current value I rm ), adjustment is possible in a continuous range. Rated currents in accordance with ambient temperature I n [A] I ϑ +55 C +4 C +2 C -5 C 6 5 6 7 9 2 9 2 22 25 25 23 25 28 3 32 29 32 36 4 4 38 4 45 53 5 48 5 56 66 63 57 63 69 83 8 73 8 88 9 5 22 25 25 32 45 6 45 6 68 75 Tripping characteristic adjustment Circuit breakers with characteristic L t L Circuit breakers with characteristic D t Ir L I I Irm Adjusting I r and I rm for circuit breakers with characteristic D Adjusting I r I I Circuit breakers with characteristic M (only for 3-pole) t Adjusting I rm Ranges of overcurrent release and their possible setting at 4 C BC6NT35- -L BC6NT35- -D BC6NT35- -M BC6NT35- -N I n [A] I n [A] I rm [A] I r [A] I rm [A] I r [A] I rm [A] I r [A] I rm [A] 6 - - 2.5 6 6 24 2.5 6 6 - - 2 - - 6 2 2 3 6 2 2 - - 25 - - 2 25 25 375 2 25 25 - - 32 - - 25 32 6 32 25 32 32-6 32 4 4 6 32 4 2 4 32 4 4-2 4 5 5 2 4 5 25 5 4 5 5-25 5 63 63 252 5 63 35 63 5 63 63-35 63 8 8 32 63 8 4 8 63 8 8-4 8 4 8 5 8-5 25 25 5 25 625 25 - - - 625 25 6 6 64 25 6 8 6 - - - 8 6 Ir L Circuit breakers with characteristic N t L I I Irm I I D33

.5.3.5.3 BC6N - Technical information OVERCURRENT RELEASES Tripping characteristic class Tripping time of the overcurrent release of circuit breakers BC6 with characteristic M at 7.2 I n corresponds to the release class A, and 2 according to EN 6947-4-. Plate of the overcurrent releases of BC6 with characteristic M I n Type Class 6 BC6NT35-6-M A 2 BC6NT35-2-M A 25 BC6NT35-25-M A 32 BC6NT35-32-M 4 BC6NT35-4-M 5 BC6NT35-5-M 2 63 BC6NT35-63-M 2 8 BC6NT35-8-M 2 BC6NT35--M 2 Tripping characteristics Characteristic L, I n = 4, 5, 63, 8,, 25, 6 A BC6NT35-...-L BC6NT45-...-L BC6NT35- BC6NT46-...-L L Characteristic D, I n = 6, 2, 25 A BC6NT35-...-D BC6NT45-...-D BC6NT35-...-D BC6NT46-...-D 6 5 6 5 3 2 3 2 5 5 5 2 t [min] 2 5 L 5 2 t [min] 2 5 L 2 2 5 In= 4...6A 5 In= 6...25A t [s] 2 t [s] 2. 5. 5. 2. I. 2. I.5.5.2.2...2. 5 2 5 2 5 x In...2.5 2 5 2 5 x In D34

..2.5.3..2 BC6N - Technical information OVERCURRENT RELEASES Tripping characteristics Characteristic D, I n =32, 4, 5, 63, 8,, 25, 6 A BC6NT35-...-D BC6NT45-...-D BC6NT35-...-D BC6NT46-...-D Characteristic M, I n = 6, 2, 25 A BC6NT35-...-M 6 5 6 5 3 2 3 2 5 5 5 2 2 L 5 2 2 L t [min] 5 t [min] 5 2 2 5 In= 32...6A 5 In= 6...25A t [s] 2 t [s] 2. 5. 5. 2. I. 2. I.5.5.2.2...2. 5 2 5 2 5 x In...2. 5 2 5 2 5 x In Characteristic M, I n =32, 4, 5, 63, 8, A BC6NT35-...-M Characteristic N, I n =32, 4, 5, 63, 8,, 25, 6 A BC6NT35-...-N BC6NT45-...-N BC6NT35-...-N BC6NT46-...-N 6 5 6 5 3 2 3 2 5 2 t [min] 5 2 5 L 5 2 t [min] 5 2 5 2 2 5 In= 32...A 5 In= 32...6A t [s] 2 t [s] 2. 5. 5. 2. I. 2. I.5.5.2.2...2. 5 2 5 2 5 x In...2. 5 2 5 2 5 x In D35

BC6N - Technical information SWITCHES Auxiliary switch PS-BC- / PS-BC--Au - changeover contact Specifications Type PS-BC-, NS-BC- PS-BC--Au, NS-BC--Au Rated operating voltage U e 6 25 V a.c. 6 25 V d.c. 5 6 V a.c. 5 6 V d.c. Rated insulation voltage U i 25 V 25 V Rated impulse U imp 4 kv 4 kv withstand voltage Rated frequency f n 5/6 Hz 5/6 Hz Rated operating current I e / U e AC-2 AC-5 DC-2 DC-3 6 A/25 V 5 A/6 V, 3 A/ V,.5 A/23 V.25 A/25 V.5 A/6 V,.2 A/ V,. A/25 V.4. A/5 6 V.4. A/5 6 V. A/6 V.4. A/5 6 V Thermal current I th 6 A.5 A Contacts arrangement Connection cross-section S.5 mm 2.5 mm 2 Terminals protection (connected switch) IP2 IP2 Signal switch NS-BC- / NS-BC--Au - changeover contact - switch can be used only in cavity No. Location of cavities in BC6N... circuit breaker/switch-disconnector When one of cavities 4, 5 or 6 is in use, cannot be used with a shunt trip or undervoltage release. Function, name and location of switches according to type designation Type Switch name Switch location Switch function PS-BC- Signals state of circuit breaker/switch-disconnector s Auxiliary Cavity 2), 2, 3, 4, 5, 6 ) PS-BC--Au main contacts NS-BC- Signals tripping of the circuit breaker Signal Cavity 2) NS-BC--Au by the overcurrent release ) - When one of cavities 4, 5 or 6 is already in use for auxiliary switches, cannot be used with a shunt trip or undervoltage release. 2) - In cavity, PS-BC- auxiliary switch and NS-BC- signal switch cannot be used simultaneously. For states of switches in circuit breaker/switch-disconnector cavities, see page D7 D36

BC6N - Technical information SHUNT TRIPS Specifications Type SV-BC-X Rated operating voltage U e 24, 48,, 23, 4 V a.c. 24, 48,, 22 V d.c. Rated frequency f n 5/6 Hz Input power at, U e AC DC 2 VA 2 W Characteristic U.7 U e circuit breaker must trip Time before switching off 5 ms Loading time Connection cross-section S.5 mm 2 Terminals protection (connected releases) IP2 Emplacement in cavity No. SIGNAL SWITCH - signals switching off by shunt trip Rated operating voltage U e 23 V a.c. Rated insulation voltage U i 25 V Rated impulse withstand voltage U imp 4 kv Rated frequency f n 5/6 Hz Rated operating current I e /U e 2 A/23 V a.c. Thermal current I th 6 A Contacts arrangement Location of cavities in BC6NT... circuit breaker/switch-disconnector When undervoltage releases are used, cavities 4, 5, 6 cannot be used for auxiliary switches. Type designation according to rated operating voltage U e Typ 24, 48 V a.c./d.c. SV-BC-X24, 23 V a.c./, 22 V d.c. SV-BC-X 23, 4 V a.c./22 V d.c. SV-BC-X23 The specific rated operating voltage of the shunt trip is set up by jumpers directly on the release. The setting from the manufacturer is always to the value corresponding to the type designation. (see fig. ) Fig. - Setting up the rated operating voltage L+ B2.Y 2 SV -BC-... B.Y N- D37

BC6N - Technical information UNDERVOLTAGE RELEASES Specifications Type SP-BC-X Rated operating voltage U e 24, 48,, 23, 4 V a.c. 24, 48,, 22 V d.c. Rated frequency f n 5/6 Hz Input power at. U e AC DC 2 VA 2 W Characteristic U.35 U e circuit breaker must trip U.85 U e circuit breaker can be turned on Time before switching off 5 ms Loading time Connection cross-section S.5 mm 2 Terminals protection (connected release) IP2 Emplacement in cavity No. SIGNAL SWITCH - signals switching off of the undervoltage release Rated operating voltage U e 23 V a.c. Rated insulation voltage U i 25 V Rated impulse withstand voltage U imp 4 kv Rated frequency f n 5/6 Hz Rated operating current I e /U e 2 A/23 V a.c. Thermal current I th 6 A Contacts arrangement Location of cavities in BC6NT... circuit breaker/switch-disconnector When undervoltage releases are used, cavities 4, 5, 6 cannot be used for auxiliary switches. Type designation according to rated operating voltage U e Type 24, 48 V a.c./d.c. SP-BC-X24, 23 V a.c./, 22 V d.c. SP-BC-X 23, 4 V a.c./22 V d.c. SP-BC-X23 The specific rated operating voltage of the shunt trip is set up by jumpers directly on the release. The setting from the manufacturer is always to the value corresponding to the type designation. (see fig. ) Fig. - Setting up the rated operating voltage L+ A2.Y 2 SP-BC-... A.Y N- D38

BC6N - Technical information HAND DRIVES Description The hand drive permits controlling the circuit breaker/switchdisconnector by turning the lever, e.g. to switch machines on and off. The drive s modular concept allows for simple mounting on the circuit breaker (even as an add-on) after removing the cavity cover. An affixed drive may be sealed. The drive and its accessories are ordered separately according to your choice, see page D. Hand drive permits controlling the circuit breaker: a) from the front panel (Fig. ) Hand drive unit RP-BC-CK.. + Hand drive lever RP-BC-CP.. b) through the switchboard door (Fig. 2) Hand drive unit RP-BC-CK.. + Extension shaft RP-BC-CH.. + Hand drive bearing PR-BC-CN.. + Hand drive lever + RP-BC-CP.. c) through the side wall of the switchboard (Fig. 3) - in left- or right-side designs Hand drive unit for side control right RP-BC-CK3 or left RP-BC-CK3 + Extension shaft RP-BC-CH.. + Hand drive bearing PR-BC-CN.. + Hand drive lever + RP-BC-CP.. Fig. - DIMENSIONS see page D24 Fig. 3 - DIMENSIONS see page D25 Hand drive unit is affixed directly to circuit breaker or switch-disconnector.. Hand drive bearing is affixed to switchboard door and provides protection IP4 or IP66. Hand drive lever is fitted onto hand drive unit or onto hand drive bearing. Extension shaft is supplied in two variants, standard (length 35 mm can be shortened) and telescopic (adjustable length 99 352 mm). It is fitted onto the hand drive unit. Enhanced safety for operator: Hand drive unit and hand drive lever also are supplied with an option to lock the circuit breaker into the switched off manually position. The hand drive unit and lever can be locked with up to three padlocks with shank diameter up 4 mm. Fig. 2 - DIMENSIONS see page D24 Every hand drive bearing prevents the switchboard door from opening when the circuit breaker is switched on or in a state of being switched off by releases. By means of the device, it is possible to turn off this locking and to open the door. Locking of the switchboard door opening also is possible in the circuit breaker s switched off manually state. It is necessary to activate the locking by means of the lever on the bearing and to lock the hand drive arm. Two circuit breakers with hand drives can be provided also with reciprocal mechanical interlocking or mechanical parallel switching (see page D4). Specifications Switchboard door locking in circuit breaker state Type Description Colour Locking while circuit b. in switched off state Protection switched on switched off manually and locked Length [mm] RP-BC-CK Hand drive unit blue no - - - - RP-BC-CK2 Hand drive unit blue yes - - - - RP-BC-CK2 Hand drive unit yellow yes - - - - RP-BC-CK3 Hand drive unit - side, right blue no - RP-BC-CK3 Hand drive unit - side, left blue no - RP-BC-CP Hand drive lever black no - - - - RP-BC-CP2 Hand drive lever black yes - - - - RP-BC-CP2 Hand drive lever red yes - - - - RP-BC-CN Hand drive bearing black - IP4 yes yes - RP-BC-CN Hand drive bearing yellow - IP4 yes yes - RP-BC-CN2 Hand drive bearing black - IP66 yes yes - RP-BC-CN2 Hand drive bearing yellow - IP66 yes yes - RP-BC-CH Extension shaft - - - - - RP-BC-CH2 Extension shaft - - - - - 35 (can be shortened) 99 352 telescopic D39

BC6N - Technical information MECHANICAL INTERLOCKING AND PARALLEL SWITCHING RP-BC-CB Mechanical interlocking Provides mechanical interlocking of two circuit breakers so that they cannot be tripped simultaneously, but always just individually. Both circuit breakers may be turned off simultaneously. Interlocking can be used between two BC6N circuit breakers. Each circuit breaker must be furnished with a hand drive (at least one with a hand drive unit and hand drive lever), see page D39. In order to use the interlocking, it is absolutely necessary to comply with the dimensions shown in the figure and given in the table. For correct function and signalling the state of the BC6 circuit breaker with RP-BC-CB mechanical interlocking, circuit breaker must be switched off, or switch-disconnector must be in loaded position. Dimensions [mm] X 87.5 or L 94.5 or 6 X L RP-BC-CD Mechanical parallel switching Provides simultaneous switching of two circuit breakers. Parallel switching can be used between two BC6N circuit breakers. Each circuit breaker must be furnished with a hand drive, and at least one with a hand drive lever, see page D39. In order to use parallel switching, it is absolutely necessary to comply with the dimensions shown in the figure and given in the table. X L Dimensions [mm] X 75 +7 or 87.5 +7 or +7 D4

BC6N - Technical information MOTOR DRIVES Motor drive side MP-BC-X...-B Connecting cable OD-BC-KA2 Description Motor drive is an accessory of the circuit breaker/switchdisconnector, by means of which it is possible to switch the circuit breaker or switch-disconnector on and off remotely. Modular design of the drives enables their simple mounting on the circuit breaker (also additionally). The drive is used for both remote and local control of 3-pole and 4-pole circuit breakers BC6. It is manufactured in the version for side mounting next to the circuit breaker on the switchboard panel or on DIN rail. Circuit breakers Modeion BC6 with the motor drive are intended for industrial, power engineering and infrastructure applications. The motor drives have a systém of direct control of the circuit breaker, without a spring storage unit. The motor drive can work in the local or remote control mode. The local control mode is used, for instance in loss of control voltage. Local control of the circuit breaker is accessibly only after lifting the transparent safety cover of the drive off. This action locks the remote electrical control circuits automatically. The lifted off position of the cover can be indicated remotely. The circuit breaker is switched on and off by means of the control lever driver. After returning the safety cover to the original position, the drive is switched into the remote control mode automatically. Motor drive automatic operation presets After tilting the safety cover off it is possible to handle an automatic mode selector switch. Under the transparent cover there is also a red LED which lighting indicates a failure (failed on/off/wind-up operations). Electronics circuits of the motor drive block erroneous control processes, e.g. drive cycling after overcurrent or auxiliary release tripping. Side drive can be locked in off position of the circuit breaker by up to three padlocks with shaft diameter with shank diameter max. 4 mm. It is possible to signal the locking remotely. The protective cover of the drives can also be sealed. The position of the main contacts of the circuit breaker is indicated by the position of the circuit breaker driver lever under the transparent protective cover of the drive. The wound up position of the circuit breaker can also be signalled remotely. In the remote control mode the circuit breaker is switched on and off by ON and OFF push buttons respectively. The motor drive accessories include an extension cable OD-BC- KA2. Switch position Automatic operation preset Preset description Circuit breaker switching off to position **) Circuit breaker winding up to position Circuit breaker switching on to position Symbol Description Switched on manually or by motor drive electrically Switched off by overcurrent releases, shunt trip or undervoltage release, TEST or REVISION push button Switched off manually or by motor drive electrically, wound up state *) Automatic winding up is on 2 3 Automatic winding up is off Simultaneous winding up and switching on - By overcurrent release - By REVISION push button - By auxiliary release - By TEST push button Motor drive carries out automatically The operator must press the OFF push button The motor drive is out of operation, the red LED is lighting By pressing of ON push button By pressing of ON push button By pressing the ON push button the motor drive will wind up and switch on the circuit breaker ***) *) Standard factory setting of the switch. **) When the circuit breaker is switched off by the motor drive electrically with the use of the OFF push button, the circuit breaker control lever gets into the wound up position automatically, independently of the automatic operation preset. ***) By pressing the OFF push button, the motor drive only winds the circuit breaker up to the position. Side drive description Locking rail Open safety cover Circuit breaker control lever driver Automatic mode selector switch LED indicating a failure (failed switching on/off/wind-up operation) D4