tech Transformer Manufacturer Sdn. Bhd. Flood Light Model: S70150 - MH70W S70150 - MH150W Specification: Ingress Protection: IP65 Voltage: 220V ~ 240VAC 50Hz Lamp Wattage: 70W ~ 150W Holder Type: RX7s Ceramic Lamp Holder Maximum Weight: 5kg Colour of Housing: White & Black DM Series - Current Transformer DM Series Model - Low Voltage Current Transformer R-DM-20/30 1 of 11
RCT Series - Current Transformer RCT Series Model - Low Voltage Current Transformer: RCT-60 RCT-90 RCT-110 RCT-25 RCT-35 Battery Tester Model: BT - 612 UFO Led High Bay Light Model: RC-UFO-100B - 100W RC-UFO-150B - 150W RC-UFO-200B - 200W Panel Meter - Power Factor Meter Power Factor Meter For 3 phase circular, balanced load 45-65Hz and for 1 phase AC 50Hz Model: DE-PE96,DE-PF72 Class: 2.5 Voltage: 100V,380V,440V Frequency: 50Hz,60Hz Scale graduation: 0.5cap-1-0.5ind,0.3cap-1-0.7ind,0.4cap-1-0.3ind Orders to be noted Type of Current: 1P,3P 3W circuits, balanced load Rated Volt: The voltage is line voltage (between two wire) Operating Current: If used with CT, the secondary current 5A or 1A is standard 2 of 11
Panel Meter - Max.Demand Ammeter Maximum Demand Ammeter For measuring mean maximum current value, when it is 8min,15min or 30min. Model: DE-M96,DE-M72 Accuracy: Class 3.0 Specification: 8min 5A,15min 5A,30min 5A,8min 1A (No specification for 30min 5A for SF-M48). With bimetal movement and thermal delayed indicator for measuring the maximum mean load during a period of 8 or 15 minutes, eats red maximum pointer. Lead seal can protect resetting knob of maximum pointer. Response time 8, 15 or 30minutes (to be specified when ordering) Heat resistance: Case of non-combustible plastic material Changeable scale: All scales with printing technique. The dial plate with different scale which is at the same internal value can be changeable. But the accuracy is unchangeable. Fastening: By means of nuts, absolutely safe, fast, robust, side-by-side Mounting depth: Max 43mm Panel Meter - Frequency Meter Moving Coil Instruments Frequency Meter Pointer Type : Model: DE-F96,DE-F72,DE-F48 Class: 1.0 Volt: 50V,100V,220V,380V Frequency: 44-55Hz,45-65Hz,55-65Hz,47-53Hz,57-63Hz,44-56Hz,54-66Hz,450-550Hz,550-650Hz 3 of 11
Panel Meter - DC Type Moving Coil Instruments DC Ammeter: Model: DE-C96, DE-C72, DE-C48 Class: 1.5 Specs: 25uA,30uA,50uA,1mA,2mA,5mA, 10mA,20mA,30mA,50mA,75mA,100mA,150mA,200mA,250mA,300mA,500mA, 1A,3A,5A,7.5A,10A,20A,30A,50A,75A,100A(used with Shunt) Note: For 60/75A/100A direct meters, the class in 2.5 Advantage: The scale can be easily changed without opening the front frame so that the class will not be influenced Moving Coil Instruments DC Voltmeter: Model: DE-C96, DE-C72, DE-C48 Accuracy: Class 1.5 Specs:3V,5V,75V,10V,15V,20V,30V,50V,75V,100V,120V,150V,200V,250V,300V,400V,45 Note: Over 6000V should be used with Ext. Resistor (Rated current 5mA) Panel Meter - AC Type Moving Iron & moving coil Instruments AC Ammeter: Model: DE-T96, DE-T72, DE-T48, DE-C96, DE-C72, DE-C48 Class:1.5 Specs:.0.1A,0.5A,1A,1.5A,3A,5A,7.5A,10A,20A,25A,30A,50A,75A,100A(use Ext.CT5A) Note: For 60A/75A/100A direct meter, the class in 2.5 Advantage: The scale can be easily changed without opening the front frame so that the class will not be influenced. Moving Iron & moving coil Instruments AC Ammeter: Model: DE-T96, DE-T72, DE-T48, DE-C96, DE-C72, DE-C48 Accuracy: Class 1.5 Specs:.30V,50V,75V,100V,120V,150V,250V,300V,450V,600V (For 450-380KV, should be used with potential transformer whose secondary voltage 100V) RC-LED High Bay Fittings IP Rating IP65 TYPE RC-LED 601-50w RC-LED 602-80w RC-LED 603-150w L.E.D Street Light - SL50W 4 of 11
L.E.D Street Light - SL80W L.E.D Street Light - SL120W L.E.D Street Light - SL150W Battery Charger Battery Charger Model: RC-126 RC-1213 RC-1524 RC-2248 5 of 11
RC-ABC Standby Automatic Standby Automatic Battery Charger Model: RC-ABC-1205 RC-ABC-1210 RC-ABC-2405 RC-ABC-2410 Protective Current Transformer Specifications Primary Current Range: 60A ~ 5000A Secondary Current: 5A Maximum Rated Voltage: 720V Working Frequency: 50Hz ~ 60Hz Insulation Class: B Current Transformer Type Class 10P5 15VA Class 10P10 15VA Class 5P10 15VA 6 of 11
Measuring Current Transformer Specifications Primary Current Range: 30A ~ 5000A Secondary Current: 5A Maximum Rated Voltage: 720V Working Frequency: 50Hz ~ 60Hz Insulation Class: B Current Transformer Type Class 1 15VA Class 3 5VA Remote Control Gear Specification : MH 70W Remote Control Gear MH 150W Remote Control Gear MH 1000W Remote Control Gear C/w (IP43 Metal Enclosure) MH 1000W, 2000W, SON 1000W Remote Control Gear C/w (IP65 High Pressure Die-Cast Aluminium Enclosure) HIGHBAY Specification & Range High Bay c/w Bulb (Plasma/ Slyvania/ Phoenix/ Philips) & 16 / 18" Aluminium Reflector. Metal Halide (MH) 250W Metal Halide (MH) 400W Mercury 250W Mercury 400W HID Ballast 7 of 11
Specification Rated Supply Voltage: 220V ~ 240VAC 50Hz Types of Ballast: Mercury (HPMV): 80W, 125W, 250W, 400W Metal Halide (MH): 70W, 150W, 250W, 400W Sodium (SON): 70W, 150W, 250W, 400W Electronic Ignitor Electronic Ignitor Model: RC9003 SP - Superimposed Ignitor RC9000 PI - Pulse Ignitor RC9000 SP - Superimposed Ignitor Voltage Stabilizer TECHNICAL SPECIFICATIONS Input Single Phase : 240V ± 10%* Three Phase : 415V ± 10%* Frequency : 50Hz / 60Hz ± 5% Output Single Phase : 240V ± 2%* Three Phase : 415V ± 2%* Frequency : 50Hz / 60Hz ± 5% Harmonic Distortion : Nil Efficiency : Better than 98% Load Power Factor : 0.5 lagging / leading ** Other range of input and output voltages available on request. Environmental Operating Temperature : 0 to 45 ºC 8 of 11
Relative Humidity : 0 to 90% non-condensing Audible Noise at : <60dB 1 meter STANDARD FEATURES Power On Indicator Output Voltmeter (3KVA and above) Output Ammeter (10KVA and above) Input Breaker (90KVA and below) OPTIONAL FEATURES Start-up delayed output connection Phase loss output disconnection Precision output with +/- 1 volt accuracy Manual by-pass activation DESIGN FEATURES No Sliding Electrical Contacts In motor-driven-variac technology, sliding contacts are the major contributors to the inherent wear and tear problems associated with the design. MCT stabilizer employs digital switching technology, eliminating the use of sliding contact, thereby achieving long term reliability. High Efficiency Motor-driven-variac technology uses two sets of transformers; a sliding transformer (variac) and a buck-boost transformer, contributing to almost all of the energy loss in the stabilizer. In contrast, the MCT stabilizer uses only one set of transformer cascading transformer), as a result the energy loss is reduced by half. Fast Correction Time Depending on the application requirement, MCT stabilizer can be configured to attain its rated output voltage level in not more than 2 second responding to a full range of supply voltage variation. Automatic Bypass Device In the unlikely event of component failure that may result in the loss of output voltage regulation, MCT stabilizer is incorporated with automatic bypass device to switch the load directly to the supply, bypassing the stabilizer circuit, without interrupting the output power. View More Info : relcotech.com.my/product/voltage-stabilizer Motor Starting Auto Transformer Technical Specification: Capacity: 3.75KW, 5.5KW, 7.5KW, 11KW(ST), 11KW(3T), 11KW(4T), 15KW, 22KW, 30KW, 37.5KW, 45KW, 56KW, 66KW, 80KW, 94KW, 110KW, 132KW, 150KW, 180KW, 225KW, 261KW, 336KW, 373KW, 418KW. E-I Silicon Steel Grade: 0.5mm Silicon Steel from Japan Tapping Percentage: Single tapping @ 70% Three tappings @ 50%, 60% & 75% Four tappings @ 40%, 50%, 60% & 75% Insulation Class: Class F & Class H Isolation Power Transformer 9 of 11
Technical Specification: Primary Voltage Range: Single Phase 110V - 240V - 380V - 415V - 440V Three Phase 200V - 220V - 380V - 415V - 440V Secondary Voltage Range: Single Phase Range 12V - 24V - 220V - 415V - 440V Three Phase 100V - 200V - 380V - 415V - 440V Capacity: Single Phase - 3VA ~ 100KVA Three Phase - 50VA ~ 500KVA E-I Silicon Steel Grade: High quality 0.5mm silicon steel from Japan Enameled Copper Wire Grade: 1PEW 150 Class 1 Polyester enameled copper wire. EIW 180 Polyesterimide enameled copper wire. 200 C Varnish bonded fibre glass covered retangular copper wire. Insulation Class: Class A, B, F & H Special Application: Auto Transformer For Heavy Duty Starting Industrial LED High Bay Bulb Model: RCB-50W RCB-100W RCB-150W 10 of 11
tech Transformer Manufacturer Sdn. Bhd. No. 26 & 28, Jalan Satu, Taman Greatyear Capital, 48000, Rawang, Selangor, Malaysia Tel 03-6093 2886 Tel 03-6091 0868 Fax 03-6092 3886 Fax 03-6092 0866 E-Mail relcomart@yahoo.com E-Mail relcotech@yahoo.com E-Mail davidrelcotech@gmail.com Website www.relcotech.com.my Manufacturer Of Power Transformer & HID Ballast 11 of 11