and Refrigeration Institute). CNX Special Purpose Contactors

Similar documents
Definite Purpose Contactors

General + Definite Purpose Contactors

General + Definite Purpose Contactors

Series CA6 Contactors

Lighting Contactors. 6.1 Open Control. Product Overview...

Technical Information

Contactor Types CI 61-98

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Industrial Contactors CTX 3 3P 185A - 800A

Sprecher + Schuh s broad line of IEC/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. Cataloged enclosures

6.1. Lighting Contactors. Contents. Application Description. Product Overview. Open Control

Technical Information

Technical Information

AF series contactors (9 2650)

Mini Contactors CI 4-

AF series contactors (9 2650)

Series CA5 Contactors

A200 NEMA Contactors and Starters A200

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

CI-TI Contactors and motor starters Types CI 61 - CI 98

The contactor for large horsepower applications

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]

Technical Information

4 - Miniature controls

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

Motor Controllers + Circuit Breakers

C -5 to +55 (0.8 to 1.1Uc) Permissible o

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Series CA7 Contactors

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Modular contactors and relays

For Info: Phone: Fax:

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

Replace ** for the required coil voltage eg: P7 (230V 50/60Hz) Co nt act or Heating Guides, 9-95A

Bulletin 100-D IEC Contactors

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

A7 Magnetic Contact/Switch CONTENTS

Industrial Control Transformers

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Product Selection 3-Pole Contactors

[V] Common Control Transformer Control (See page 1-78 Note)

Application Description

4.1. Definite Purpose Contactors and Starters. Contents

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

IEC Utilization Categories (Explanation)

Operation and Protection of Motors up to 600Hp at 460Vac (800A)

Lighting and Heating Control Electrically Held Lighting Contactors

4.1. Lighting Contactors. Contents Description UL Rated AC Contactors Catalog Number Selection...

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Industrial contactors CTX-1

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Certi 堵脝 cation Record

TYPE LS-K CONTACTORS TECHNICAL SPECIFICATIONS

Installation Contactors RIC, RAC

C E R T I F I C A T E O F C O M P L I A N C E

Command and signalling E 250, E 259 selection table

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

JOSLYN CLARK VACUUM CONTACTOR FEATURES

Selection Guide Motor Control Device Solutions

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Modular contactor for installation into distribution boards

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

Micro Contactor MA Series

W Datasheet: DIN Rail Contactors, series AMPARO

JOSLYN CLARK VACUUM CONTACTORS

Series L9 UL489 Miniature Circuit Breakers

General information about motor protection

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

CI-TI Contactors and Motor Starters Type CI 6-50

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V)

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Controls. CONTACTORS CWB Line (up to 40A)

Series KTU7 UL489 Molded Case Circuit Breakers

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

NEMA Contactors & Starters (Freedom)

Series KTU7 UL489 Molded Case Circuit Breakers

Type E/F Simplex & Duplex Pump Controllers

Quick selection table

KT4 Manual Motor Starter

For many applications

Ideal for use as a manual starter

XT SERIES Jockey Pump Controllers Features

ESW/PESW. Non-Combination Starters

Series CA6 Contactors

Operation and Protection of Motors up to 600Hp at 460Vac (800A)

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON

Transcription:

Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors NEM size labeled contactors The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases, these devices are UL and CS approved for these specialized uses. Where appropriate, contactors also carry approval by specific industry associations such as RI (ir Conditioning and Refrigeration Institute). CNX Special Purpose Contactors CNX Special Purpose Contactors are rated by FL & LR as well as resistive current rated - primarily to meet the demands of the HVC and compressor markets. CNX contactors have all the flexibility of a C7 contactor like easy coil change out, DIN rail mounting and field installable auxiliaries as well as mechanical interlocks not normally associated with true definite purpose contactors. CNX contactors may also be combined with CEP7 or CT7N overload relays to make a special purpose starter. CNX starters are cul rated and labeled as well as RI (ir Conditioning and Refrigeration Institute) approved. CN7 NEM size labeled contactors CN7 contactors are UL Listed in accordance with NEM standards publication ICS-2. CN7 contactors are UL labeled for application under IEC KW, as well as NEM Size, for specified horsepower at various voltages. CN7 contactors have been purposely selected larger to increase the life of the device. Only the devices listed here are available with the NEM size on the UL label. CN7 NEM sized contactors may be combined with all Sprecher + Schuh overload relays to make a NEM sized starter. Hydraulic Elevator Wye-Delta Contactors Most industrial wye-deltas consist of three contactors with interlocks but Hydraulic Elevators are a special application. Hydraulic Elevator wye-deltas consist of a pair of mechanically linked contactors with sufficient auxiliaries for electrical interlocks. The wye-delta is similar to a reversing contactor but the power wiring is different. We offer Hydraulic Elevator contactors with a choice of power wiring inter-connections for ease of installation, or without power wiring inter-connections, allowing the elevator serviceman to make use of the existing power cables. This convenient selection of a complete assembly saves time and effort in the field. 40

Special Use Contactors - C Coil Special Purpose Contactors - Series CNX Non-Reversing, Three Pole Special Purpose Contactors With C Coil (Open type only) ➊ Full Load mps Locked Rotor mps - 3Ø Resistive mps ➌ 1 Ø 3 Ø Contacts per Contactor 200V 200V/ 230V 460V 575V 115V 230V 208V 230V 460V 575V NO NC Catalog Number Price 15 91 91 66 25 1-1/2 3 4 5 10 10 1 0 CNX-205-165 0 1 CNX-206-165 30 180 150 120 40 2 5 7-1/2 10 20 20 1 0 CNX-207-235 0 1 CNX-208-235 0 0 CNX-209-00- 273 40 240 200 160 50 3 5 10 10 25 25 1 0 CNX-209-10- 292 0 1 CNX-209-01- 292 0 0 CNX-212-00- 305 50 300 250 200 65 3 7-1/2 10 15 30 30 1 0 CNX-212-10- 325 0 1 CNX-212-01- 325 0 0 CNX-218-00- 481 90 540 450 360 120 ~ ~ 25 30 60 60 1 0 CNX-218-10- 500 0 1 CNX-218-01- 500 CNX-208-120 Special Purpose contactor Description Series CNX Special Purpose Contactors are standard C7 contactors that have been tested, approved and labeled by UL for heating, ventilation and air conditioning (HVC) applications. ➋ Coil Codes ➋ C Coil Code Voltage Range 50 Hz 60 Hz 220W 200V-220V 208V-240V 240 220V 277V 277 240V 440V 380 380V-400V 480V ➊ ll CNX contactors listed here are RI (ir Conditioning and Refrigeration Institute) approved. ➋ Other voltages available, see page 56. ➌ Reference page 77 for Operation Life Data. Discount Schedule B7 41

Special Use Contactors - C Coil NEM Labeled Contactors - Series CN7 Non-Reversing, Three Pole NEM Labeled Contactors with C Coil ➊ NEM Size 1Ø 3Ø Standard Contacts 115V 230V 200V 230V 460V 575V NO NC Catalog Number 00 1/3 1 1-1/2 1-1/2 2 2 1 0 CN7-12-10-283 0 1 2 3 3 5 5 1 0 CN7-16-10-320 Price 1 2 3 7-1/2 7-1/2 10 10 1 0 CN7-37-10-376 2 3 7-1/2 10 15 25 25 1 0 CN7-43-10-670 CN7 NEM1 labeled contactor (C) 3 7-1/2 15 25 30 50 50 1 0 CN7-85-10-1130 pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See page 56 for CN7 coils. Snap-on auxiliary contact blocks available in many configurations. See pages 47-48. vailable as open units or in Type 1, 3R, 4, 4X and 12 enclosures. Contact your Sprecher + Schuh representative for enclosed pricing. NEM sized starters with C Coils are listed on page C52. CN7 C Coil Codes ➋ CN7-12...85 C Coil Voltage Range Code 50 Hz 60 Hz 220W 200V-220V 208V-240V 240 220V 240V 277 240V 277V 380 380V-400V 440V ➊ Refer to page 85 for CN7 dimensional information. ➋ Other voltages available, see page 56 for other coil voltage. 42 Discount Schedule B8

Non-Reversing, Three Pole NEM Labeled Contactors with DC Coil ➊ NEM Size 1Ø 3Ø Standard Contacts 115V 230V 200V 230V 460V 575V NO NC Catalog Number 00 1/3 1 1-1/2 1-1/2 2 2 1 0 CN7-12E-10- ➌ 495 0 1 2 3 3 5 5 1 0 CN7-16E-10- ➌ 551 1 2 3 7-1/2 7-1/2 10 10 1 0 CN7-37E-10- ➌ 607 2 3 7-1/2 10 15 25 25 1 0 CN7-43E-10- ➌ 879 Price 3 7-1/2 15 25 30 50 50 2 1 CN7-85D-10-1164 Special Use Contactors - DC Coil NEM Labeled Contactors - Series CN7 CN7 NEM1 labeled contactor (24V Electronic DC shown) pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See page 57 for CN7 DC coils. Snap-on auxiliary contact blocks available in many configurations. See pages 47-48. vailable as open units or in Type 1, 3R, 4, 4X and 12 enclosures. Contact your Sprecher + Schuh representative for enclosed pricing. NEM sized starters with C Coils are listed on page C52. CN7 Electronic DC Coil Codes ➌➍ CN7-12E...43E DC Coil Code Voltage Range 12E 12V 24E 24V 36E ➎ 36-48V 48E ➎ 48-72V 110E ➎ 110-125V 220E ➎ 220-250V CN7 DC Coil Codes with integrated Diode ➋ CN7-85D DC Coil Code Voltage Range 24DD 24V 110DD 110V ➊ Refer to page 86-87 for CN7 dimensional information. ➋ Other voltages available, see page 57 for other coil voltage. ➌ CN7-12E..43E electronic coils are not interchangeable with non-electronic DC or C coils. ➍ Voltages of 36V DC and greater are supplied with backpack module standard. See page 86. ➎ Not applicable with Electronic Timer accessories (CRZ_7). Discount Schedule B8 43

Hydraulic Elevator Wye Delta, with C Coils (Two Contactor Type ➊) Three Phase Industrial pplication ➎ UL/CS Elevator Duty ➏ Contacts per Contactor Open Type 200V 230V 460V 575V NO ➍ NC ➌ Catalog No. Price 10 15 30 30 0 1 C7Y2-30-02- -LW 531 10 10 30 30 1 1 C7Y2-30-22- -LW 572 15 20 40 40 0 1 C7Y2-37-02- -LW 616 10 15 30 40 1 1 C7Y2-37-22- -LW 655 20 25 50 50 0 1 C7Y2-43-02- -LW 667 15 15 40 50 1 1 C7Y2-43-22- -LW 706 25 30 60 60 0 1 C7Y2-55-02- -LW 738 TBD TBD TBD TBD 1 1 C7Y2-55-22- -LW 777 30 40 75 75 0 1 C7Y2-60-02- -LW 880 15 25 50 60 1 1 C7Y2-60-22- -LW 918 40 50 100 100 0 1 C7Y2-72-02- -LW 996 25 30 60 75 1 1 C7Y2-72-22- -LW 1035 50 60 125 125 0 1 C7Y2-85-02- -LW 1109 30 40 75 100 1 1 C7Y2-85-22- -LW 1150 50 60 125 125 0 1 C7Y2-97-02- -LW 1341 TBD TBD TBD TBD 1 1 C7Y2-97-22- -LW 1381 HP Selection Larger sizes available. Contact your Sprecher + Schuh representative. C7-30..37 Reduced Voltage Contactors - C Coil Wye Delta - Series C7Y2 C7Y2-30 Wye-Delta contactor Includes: Line side coil terminations Mechanical and electrical Interlocks ➋ C7Y2-60 97 include a back pan Optional: Power Wiring available but not included (see page 55) ➊➐ Elevator controllers often require additional auxiliary contacts. ➌ C7-30..37 C7-PWD43 C7-43..55 C7-43..55 2M S 2M S C7-PWD43 C7-PWLM37M C7-PWLM55M Coil Codes ➍ C Coil Voltage Range Code 50 Hz 60 Hz 220W 200V-220V 208V - 240V 240 220V 240V 277 240V 277V 380 380V-400V 440V ➊ For -PW Option dd the following to List Price C7Y2-30 37 25 C7Y2-43 55 32 C7Y2-60 97 45 C7-60..97 2M C7-PWLM85M C7-60..97 C7-PWD85 ➊ For Contactors with power wiring change catalog number suffix -LW to -PW. For example C7Y2-30-22- -LW becomes C7Y2-30-22- -PW. NOTE: C7Y2-30 55-22- -PW do not include a backpan. ➋ The NC auxiliary contacts are supplied as part of the mechanical interlock (Cat.# CM7-02) and are used to electrically interlock the contactors. ➌ The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliary contacts must be special ordered. Contact your Sprecher+Schuh representative. ➍ Other voltages available, see page 56. ➎ HP selection based on UL508 for Industrial pplications. ➏ HP selection based on UL/CS Elevator Duty Ratings. ➐ See typical Wye-Delta Wiring Diagram on page C117. S 44 Discount Schedule B7

Series CL7 Lighting Contactors Compact contactors for North merican lighting applications Sprecher + Schuh C7 contactors can be used to control a wide variety of lighting loads. These contactors are well suited to handle the high inrush currents typical of this application as well as other non-motor (resistive) loads. Lamps can basically be divided into three categories: Tungsten Filament Lamps - General purpose incandescent - Special purpose incandescent - Infrared - Sodium Iodine Discharge Lamps (with Ballast) - Fluorescent lamps - Mercury vapor - High/low pressure sodium - Quartz - Halogen metal-vapor Mixed Light Lamps In application The tungsten filaments of incandescent lamps have a very low ohmic resistance when cold. s a result, the closing current is very high but also very short. The closing current of discharge lamps (lighting with ballast) is highly inductive (due to series-connected transformers or chokes), and its duration depends on the lamp type. In general, North mericans refer to Lighting Contactor ratings in amperes without distinction between incandescent or ballast type of load. The lighting contactor selection table provided on the following page is for North merican use, so ratings are selected for mixed lamp loads which account for the higher incandescent inrush. Electrically held contactors Electrically held contactors are available for use where the control signal is activated by a timer or other maintained electrical signal. The coil is energized as long as the contactor is closed. This design is well suited for applications where lights are operated frequently or where the control panel is in a remote location. Mechanically held contactors Mechanically held contactors are available for applications where quiet operation or critical lighting is required, i.e., institutions, hospitals and residential/commercial areas. fter the contactor closes, the voltage is disconnected from the operating coil and the contactor is held closed by the mechanical latch. Built-in clearing interlocks allow control from either a momentary or maintained pilot device for the separate pull-in and release functions. Europeans usually separate the values for incandescent from discharge (ballast) lighting. Both values are provided in the technical section of our general catalog and may be more appropriate for those applying by CE standards. CL7-20 60 are labeled and UL approved for lighting applications 45

Special Use Contactors - C Coil Lighting Contactors Series CL7 & CVL7 Lighting Contactors with C Coil ➍➎ Continuous Standard Max. C Volts, Type of mpere Open Poles to Load Load Rating Contacts Holding Type ➌ 1 for 1ø 3 for 3ø NO NC Type Catalog Number Price Tungsten or 20 277 480Y/277V Electrical CL7-20-M40-274 Ballast 15 347 600Y/347V 4 0 0 General 30 600 600 Mechanical CVL7-20-M40- -L10 ➊ 532 Tungsten or 30 277 480Y/277V Electrical CL7-30-M40-405 Ballast 25 347 600Y/347V 4 0 0 General 37 600 600 Mechanical CVL7-30-M40- -L10 ➊ 600 Tungsten or 60 277 480Y/277V Electrical CL7-60-M40-687 Ballast 55 347 600Y/247V 4 0 0 General 85 600 600 Mechanical CVL7-60-M40- -L10 ➊ 843 Larger sizes available. Contact your Sprecher + Schuh representative. See catalog page C44 for enclosed lighting contactors. # of Poles Operation of Mechanically Held Contactor with ON-OFF Pushbutton Catalog number CVL7 consists of a CL7 contactor with CV7-11 mechanical latch. Depressing the ON button energizes the L coil and the contactor closes. The mechanical latch locks the contactor in the closed position. The L coil is then deenergized by the coil, clearing contact UL (Terminals 65-66) to remove voltage. Depressing the OFF button energizes the UL coil, and the mechanical latch releases the contactor. The UL coil is immediately de-energized by the coil clearing contact L (Terminals 13-14) to remove voltage. The contactor is now open. Description The CL7 electrically held contactors and CVL7 mechanical held contactors are cul rated and labeled for tungsten and ballast lighting duty applications at 20, 30, and 60 amperes respectively. C(L)7 Coil Codes ➋ C Coil Code Voltage Range 50 Hz 60 Hz 220W 200V-220V 208V-240V 240 220V 240V 277 240V 277V 380 380V-400V 480V ➊ The N.O. auxiliary on the mechanical latch is used by the control circuit and is not available to the customer for other uses. ➋ Other voltages available, see page 56. ➌ Engineering practice permits 2.5 x I e to be applied to a contactor when 3 poles are connected in parallel for single phase discharge lamp (ballast lighting) applications. For example CL7-20-M40- Lighting Contactor plus a C7-P-B23 Paralleling Link can be used on a 50 ballast load. pplying parallel conductors to incandescent lamp loads does NOT result in a greater permissible load. Paralleling Links can be found in the ccessories section. ➍ Lighting contactor applications greater than 4-poles can be achieved. Contact Sprecher + Schuh representative for assistance. ➎ Definite Purpose Contactors can also be used in Lighting Contactor applications. See page 183. 46 Discount Schedule B7