TRITON 3:1 irculating Pumps TRITON 13HP 23375 & 233751 TRITON 38HP 23385 & 233816 Low shear, low pulsation performance delivers superior finish quality FETURES ND ENEFITS Low pulsation output provides a high quality finish for a consistent pattern and film on finished parts Low shear pumping action means minimal material degradation on circulating paints and coatings Diaphragm seal eliminates conventional throat packings and reduces maintenance costs Smooth pump fluid passages minimize time and material required for color changes and flushing Extremely quiet pump operation offers comfortable working conditions Two different pump sizes available: 38HP for smaller volume circulating systems and 13HP for larger volume circulating systems FINISHING PROVEN QULITY. LEDING TEHNOLOGY.
State-of-the-rt irculating Pump for Today s Demanding Materials! Quiet ir Motor For low sound level operation Spring-Loaded all hecks Provide superior priming and smooth flow delivery ccessory Outlet Fitting Offers a direct connection for hose and spray gun Precision ir Motor Valve Offers excellent control at low input pressures for wide performance range ll Stainless Steel onstruction Provides lasting durability when used with waterborne and solventborne materials Simple ir Valve Design Reduces repair time 1-Piece Diaphragm PTFE, diaphragm plate and rubber are molded together for smooth, quick flushing diaphragm operation Typical Fluids Handled Waterborne paints Solventborne paints Wood coatings Typical pplications Paint circulating systems oothside/satellite paint circulating systems Wood coating circulating systems
Typical Installation for TRITON 13HP in irculation System E F D G This drawing is a guide to provide a typical system layout. onsult an authorized Graco distributor before installing or designing a circulation system. KEY D TRITON 13HP irculation Pump Heavy-duty back geared agitator with drum cover, elevator and siphon kit ir Gard TM Runaway Valve ir Regulator FLUID LINES E Fluid supply line to spray booth F Fluid return line from spray booth IR LINES G ir supply line
Technical Specifications TRITON 38HP TRITON 13HP Pump ratio 3:1 3:1 Maximum fluid outlet pressure 3 psi 26 psi (21 bar, 2.1 MPa) (17.9 bar, 1.8 MPa) Maximum air input pressure 1 psi 88 psi (7 bar,.7 MPa) (6.1 bar,.6 MPa) Fluid flow @ 2 cpm.8 gpm (3.2 lpm) 1.85 gpm (7. lpm) Volume per cycle 5 oz (15 cc) 11 oz (35 cc) Maximum recommended continuous cycle rate 2 cpm 2 cpm ir consumption @ 88 psi air @ 2 cpm 3 scfm (.8 m 3 /min.) 1 scfm (.28 m 3 /min.) Sound pressure level @1 psi air @ 2 cpm 67 d 67 d ir motor inlet 1/4 npt(f) or 3/8 SPP(f) 1/2 npt(f) or 1/2 SPP(f) Pump fluid inlet 3/4 npt(f) or M26 x 1.5(f) 1 npt(f) or 1 SPP(f) Pump fluid outlet 3/8 npt(f) or 3/8 SPP(f) 1 npt(f) or 1 SPP(f) Weight 26 lb (12 kg) 64 lb. (29 kg) Instruction manual 39479 39476 Note: npt is National Pipe Taper thread SPP is ritish Standard Pipe Parallel thread for straight thread installations Performance urves TRITON 38HP FLUID OUTLET PRESSURE psi (bar, MPa) 3 (2.7, 2.) 25 (17.2, 1.7) 2 (13.8 1.4) 15 (1.3, 1.) 1 (6.9,.6) 5 (3.4,.3) YLES PER MINUTE 13 26 39 52 65 78 91 gpm.5 1 1.5 2 2.5 3 3.5 (lpm) (1.9) (3.8) (5.7) (7.6) (9.4) (11.3) (13.2) FLUID FLOW (Pump tested in No. 1 weight oil) 3 (.85) 25 (.71) 2 (.57) 15 (.42) 1 (.28) 5 (.14) IR ONSUMPTION scfm (m 3 /min.) TRITON 13HP FLUID OUTLET PRESSURE psi (bar, MPa) 3 (2.7, 2.) 25 (17.2, 1.7) 2 (13.8 1.4) 15 (1.3, 1.) 1 (6.9,.6) 5 (3.4,.3) YLES PER MINUTE 5 11 16 21 27 33 4 gpm.5 1 1.5 2 2.5 3 3.5 (lpm) (1.9) (3.8) (5.7) (7.6) (9.4) (11.3) (13.2) FLUID FLOW (Pump tested in No. 1 weight oil) 3 (.85) 25 (.71) 2 (.57) 15 (.42) 1 (.28) 5 (.14) IR ONSUMPTION scfm (m 3 /min.) IR PRESSURES LEGEND = @ 1 psi (6 bar,.6 MPa) ir onsumption = @ 6 psi (4 bar,.4 MPa) Fluid Flow = @ 3 psi (2 bar,.2 MPa) IR PRESSURES LEGEND = @ 88 psi (6 bar,.6 MPa) ir onsumption = @ 6 psi (4 bar,.4 MPa) Fluid Flow = @ 3 psi (2 bar,.2 MPa) Operating Notes: 1. Recommended continuous duty performance range is up to 2 cycles per minute. Flow rates exceeding 2 cycles per minute are achievable, but recommended for intermittent duty only. 2. Pump diaphragm life expectancy may decrease when operating above 2 cycles per minute continuously for extended periods of time. 3. void pressure-feeding pumps or operating pumps dry for extended periods of time. 4. During pump start-ups, gradually increase air inlet pressure and pump cycle rate.
Ordering Information 1. Select 38HP or 13HP, based on flow requirements of the circulating system. Refer to TRITON 38HP and 13HP pump performance charts 2. Select npt or SPP thread design based on circulating system pumping requirement 3. Order pump part number TRITON 38HP TRITON 38HP TRITON 13HP TRITON 13HP Pump Part Number (are Pump Only) 233816 23385 233751 23375 onstruction SST SST SST SST Thread design npt SPP npt SPP Seat onstruction SST SST SST SST all guides construction cetal cetal cetal cetal all construction cetal cetal cetal cetal Diaphragm construction PTFE PTFE PTFE PTFE Repair Kits Ordering Information PTFE diaphragm repair kit 24611 24611 243152 243152 ir valve repair kit 24566 24566 243153 243153 cetal balls and stainless seats kit (qty: 4 each) 24567 24567 243154 243154 Pneumatic cylinder seal repair kit N/ N/ 243155 243155 Fluid manifold seal kit N/ N/ 243156 243156 Mounting ccessories for TRITON 13HP 245875 Wall Mount Kit Includes wall bracket and hardware for mounting TRITON 13HP pump to wall. Does not include pump. 245874 Floor Stand Kit Includes stand frames and hardware for mounting TRITON 13HP pump on floor. Does not include pump.
ccessories for TRITON 38HP 2244 Pump Runaway Valve Use to prevent pump from running dry and running at high cycle rates. Maximum working pressure: 12 psi (.8 MPa, 8.4 bar). Inlet and outlet: 3/4 npt(f). 197426 Wall racket Includes wall bracket and hardware for mounting the TRITON 38HP pump on wall. Does not include pump. 23899 Grounding Wire and lamp 1 gauge, 25 ft (7.6 m) wire 24583 Suction Hose, Stainless Used to siphon material out of a 5 gal (18.9 l) pail. Includes 4 ft (1.2 m) hose, stainless siphon tube, and inlet strainer. Hose outlet fitting: 3/8 JI(f) (9/16-18 unf). 24585 Suction Hose Kit, Stainless, 55 Gallon Drum Used to siphon material out of a 55 gal (2 l) drum. Includes 6 ft (1.8 m) hose, stainless siphon tube, acetal bung adapter and inlet strainer. Hose outlet fitting: 3/8 JI(f) (9/16-18 unf). 1121 dapter Fitting, Stainless Use with bushing 11635 to connect 24583 and 24585 suction hose kits to TRITON 38HP fluid inlet. 3/8 JI(m) (9/16-18 unf) x 3/8 npt(m). 11635 Pipe ushing, Stainless Use with adapter fitting 1121 to connect 24583 and 24585 suction hose kits to TRITON 38HP fluid inlet. 3/4 npt(m) x 3/8 npt(f). ccessories for TRITON 13HP 245874 Floor Stand, 4-legged Includes stand frame and hardware for mounting the TRITON 13HP pump on the floor. Does not include pump. 245875 Wall racket Includes wall bracket and hardware for mounting the TRITON 13HP pump on wall. Does not include pump. 2244 Pump Runaway Valve Use to prevent pump from running dry and running at high cycle rates. Maximum working pressure: 12 psi (.8 MPa, 8.4 bar). Inlet and outlet: 3/4 npt(f). 2892 Siphon Kit, luminum Use to siphon fluid from a 5 gal (18.9 l) pail. Includes nylon suction hose 1776, 1 in ID, 4 ft (1.2 m) long, 3/4 npt(f) swivel. 23899 Grounding Wire and lamp 1 gauge, 25 ft (7.6 m) wire ll written and visual data contained in this document are based on the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. all today for product information or to request a demonstration. 1.877.84GRO (1-877-844-7226) or visit us at www.graco.com. 22, 24 Graco Inc. Form No. 3246 Rev. 5/4 Printed in the U.S.. ll other brand names or marks are used for identification purposes and are trademarks of their respective owners.