ADVANCE- GRP[ GD] S ERIES OP TIMA- EX[ GD] S ERIES

Similar documents
IS OL ATORS-EX S ERIES

ADVANCE GRP Series 125A Switched Interlocked socket outlets

IS OL ATOR S S E RIE S. Enclosed change-over switches I/O/II

UNIBOX Series Enclosure and wiring accessories IP40-IP55

EX-REPAIR AND MAINTENANCE RECEPTACLES

Plug and Socket Devices SolConeX 16 A Series 8570

M-0. M-0... series control, monitoring and signalling devices. Ex e

Linear Luminaire with LED Series EXLUX 6402/2

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

International approvals.

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

Emergency Luminaire with LED Series EXLUX 6409/1

Plug 16A 2P+E extra flat Wireable (body length up to 50 mm) SPA17. Plug 10A 2P+E straight S11. Plug 16A 2P+E straight S30. Plug 16A angled S30

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

YFC. Limit switch. Ex d. 24 operating head types

CCAI, CCAIF, CCAIF..H

Position Switches Series 8060/2

A good connection. International approvals.

Linear Luminaire with LED Series EXLUX 6002

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

ADVANCE- GRP S YS TEM. Switched Interlocked socket outlets [ ]

Ex e, ia Junction boxes TNCN. Features

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

LED Linear Luminaire Series EXLUX 6402

Unused flameproof threads for cable glands have to be closed with certified plugs.

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

FHL. Ex d. Body in aluminium

Position Switches Series 8074/2

I Ex-safety switches I

Position Switches Series 8070/2

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

Compact Sheet-Steel Light Fittings Series 6114/1

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS

Floodlight LED Series 6125

Solenoid coils VACF Type codes

PY, SPY; FSQC, FP; EPC; AP

INSTRUCTION MANUAL (ATEX / IECEx)

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

Glass Reinforced Polyester Enclosures

Junction boxes for control, monitoring and control panel Ex tb

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

I Ex-Safety switches I

INSTRUCTION MANUAL (ATEX / IECEx)

EXEL-L. Detail of the internal side. Transparent polycarbonate

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Flameproof Enclosures

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Operating Instructions

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

A good connection. International approvals.

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

Floodlight LED Series 6525

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Permissible overload. 22 A > A Hz > Hz 42 A > A. Heat resistance

Floodlight LED Series 6525

New products Ex Equipment 2015

Mechanical features. Spring-loaded elastic terminals: resist vibrations

I Ex-safety switches I

Compact Sheet-steel Emergency Light Fitting Series 6118/1

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

Terminal Boxes Series 8125

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

OPERATING INSTRUCTIONS

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

E-MOBILITY EVSE COMPONENTS

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Rated current In (A) Other electrical data. IEC 309 range. EN see 70 RT range IK

explosive environments Lighting

COMBUSTION AND ENERGY

Terminal Boxes in Stainless Steel SLS**.T

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Control Buttons / Switches for Panel Mounting Series 8003

PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

7 Lighting Technology

EX-D ENCLOSURES AND DISTRIBUTIONS

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Transcription:

ADVANCE GRP[ GD] S ERIES OP TIMA EX[ GD] S ERIES Plug and socket for applications in potentially explosive atmospheres GAS & DUST [ ATEXIECEx ] II 2GD

ADVANCEGRP[GD] Series OPTIMAEX[GD] Seriesimbro ATEXIECEx SPECIAL CHARACTERISTICS OUTSTANDING IMPACT RESISTANCE The glassfibre reinforced polyester used in ADVANCE GRP[GD] and the high thickness of the casing walls guarantee an excellent mechanical resistance to impacts. The SMC technology used to produce the casings makes ADVANCEGRP[GD] an indestructible product. The impact resistance of the casings is higher than 20J (IK10) according to EN50102, even under limit temperature conditions (50 C +0 C). RESISTANCE TO CHEMICAL AGENTS The ADVANCEGRP[GD] interlocked sockets and casings, thanks to the glassfibre reinforced polyester with which they are produced, have excellent resistance to aggressive chemical substances, saline solutions, diluted acids, hydrocarbons, mineral oils, alcoholic substances. They are ideal for use in highly corrosive atmospheres. RESISTANCE TO ATMOSPHERIC AGENTS The structure and materials used also make ADVANCE GRP[GD] a product suited for the most extreme environmental conditions. The degree of protection IP, guarantees an excellent seal against the entry of solid objects or liquids into the casings. Outstanding resistance to UV radiation, exceptional reliability under environmental stress and use at both low and high ambient temperatures (40 C +0 C) for 3/1A and (50 C + 0 C) for 1/32A. 2 In the chemical and petrochemical plants, or, in general, in all those places where, a production process gives the possibility to forming a potentially explosive atmosphere are necessary electrical equipment that protect from the risk of explosion and they comply at ATEX Directive 4 /2/EC. SCAME complete the ATEX project, which currently covers only the dust area (Zone 21), introducing a safety switch designed and manufactured by SCAME till 80A suitable for GAS environments. The plugs and sockets for Zone 1 unlike dust, require special design arrangements including the materials and the necessity of having a key insertion to prevent the connection of plugs of other builders, these and other, measures are required to prevent that any spark or arc, is formed through cutting the supply voltage, or at the time to coupling or decoupling plug and socket body, where they can come into contact with the surrounding atmosphere and cause an explosion. Upgrading to ZONE 1, the series as ADVANCEGRP[GD] and OPTIMAEx[GD] include the entire range, from 1A, 32A, 3A, up to 1A.

CHARACTERISTICS The ADVANCEGRP[GD] product line includes a series of 1A, 32A, 3A, 1A interlocked sockets (compliant with EN0304 standards) and the casings to contain them. It's the most complete range of interlocked sockets produced in GRP (Glass Reinforced Polyester) thermosetting material. A unique feature which enhances the exceptional mechanical strength of ADVANCEGRP[GD] products is the SMC (Sheet Moulding Compound) production process used for the casings. SMC is a technology which uses exclusively nonwoven sheets, preimpregnated with polyester resin. This method consists in preparing the sheet material inside a mould which, equipped with a negative mould, presses the composite so as to allow compaction. SMC is an advanced technology which enhances the quality of the raw material without reducing the highstrength characteristics during transformation; it's a highperforming technology in terms of the mechanical performance of the resultant product (glass fibre length, homogeneity of the material, integrity of the fibres). On the contrary, the BMC (Bulk Moulding Compound) technology is a technology for moulding composite materials which uses a raw material available in "blocks" (short, charged fibres) which are subjected to high thermomechanical stress during the transformation process, consequently diminishing the mechanical properties of the details, thereby reducing the impact strength and flexural strength. The glassfibre reinforced polyester used in ADVANCEGRP[GD] guarantees excellent mechanical strength and a long lifetime: this material is highly resistant to contamination, completely corrosion resistant and suited for applications requiring the use of components with low smoke emission and no halogens, LSOH (Low Smoke Zero Halogen) components. The outstanding properties of the material are also guaranteed over time, thanks to the high RTI value (Relative Temperature Index), measured to be 20,000h. Numerous verifications and tests have been carried out, even UV resistance tests, in order to guarantee the long duration of the material's initial performance. ATEXIECEx ADVANCEGRP[GD] Series OPTIMAEX[GD] Series OUTSTANDING HEAT AND FIRE RESISTANCE The glassfibre reinforced polyester used in ADVANCEGRP [GD] guarantees excellent heat and fire resistance: it does not propagate flames, emit halogens or smoke. This material has outstanding flame retardancy: Glow Wire 0 C according to EN 0521; V0 according to UL4. It's suited for applications requiring the use of components with low smoke emission and no halogens, LSOH (Low Smoke Zero Halogen). 3

ADVANCEGRP[GD] Series OPTIMAEX[GD] Series ATEXIECEx SWITCHED INTERLOCKED SOCKET OUTLETS REFERENCE STANDARDS ATEX IECEx IEC 0070 / EN 0070 Explosive Atmospheres. Part 0: general requirements. ATEX IECEx IEC 0070 / EN 0070 Explosive Atmospheres. Part 1: equipment protection by flameproof enclosures d. ATEX IECEx IEC 0070 / EN 0070 Explosive Atmospheres. Part 31: equipment dust ignition protection by enclose t. ATEX IECEx IEC 0070 / EN 0070 Explosive Atmospheres. Part 7: equipment protection by increased safety e. VERSIONS WITH MECHANICAL INTERLOCK With switchdisconnector 1A32A 3A1A EN 0301 Plugs, socket outlets and couplers for industrial purposes. Part 1: general requirements. EN 0302 Plugs, socket outlets and couplers for industrial purposes. Part 2: dimensional interchangeability requirements for pin and contacttube accessories of harmonised configurations. PRODUCTS FOR USE IN A POTENTIALY EXPLOSIVE ENVIRONMENT Scame offers products suitable for installation into environments under potential risk of explosion identified as Zone 1/22 and that enter into the field of application for the ATEX Directive (European Directive 4//CE and IECEx). EN 0304 Plugs, socketoutlets and couplers for industrial purposes. Part 4: Switched socketoutlets and connectors with or without interlock. SOCKET LABEL PLUG LABEL 5 0 4. 1 7 0 I N E R I S x x AT E X x x x x I E C E x I N E x x. x x x Ex d e IIC Tx Gb Ex tb IIIC Txxx C Db IP Ta m b. 50/+0 C E N 0 4 7 3 3 P + N I t h 8 0 A U i 0 V ~ 5 0 / 0 H z AC 2 3 A 3 A 5 0 0 V ~ AC 2 2 A 3 A 0 V ~ DO NOT OPEN WHEN ENERGIZED IN PRESENCE OF EXPLOSIVE ATMOSPHERE 0 0 5 1 I I 2 G D 2 1. 3 3 I N E R I S x x AT E X x x x x I E C E x I N E x x. x x x Ex e IIC Tx Gb Ex tb IIIC Txxx C Db IP Ta m b. xx/+xx C 3 P + 3 A U 3 8 0 4 1 5 V~ 0 0 5 1 I I 2 G D 4

BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS Saline solution Acids Bases Solvents Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol Mineral oil UV rays ATEXIECEx Resistant Rated current: Rated voltage: Frequency: Interlocked switch sockets: 1A32A3A1A: Plugs CE certificate 1A32A3A1A: 1A32A3A1A 100 0V~ 50 0Hz Insulating voltage: 0V~ Switchdisconnectors: 1A32A3A 1A ATEX Code: Limited Resistance Ex Protection type: Resistant COMMANDEX Series CZ0513 II 2GD Limited Resistance For specific substances please contact our technical service. TECHNICAL CHARACTERISTICS Ex d e IIC Txxx C Gb Ex tb IIIC T80 C Db IP Ambient temperature range: 50 C + 0 C for plug 1/32A 40 C + 0 C for plug 3/1A ATEX IEC Ex CERTIFICATE ELECTRICAL FEATURES UNDER CERTIFICATION INERIS XXATEXXXXX IECEx INExx.xxx UNDER CERTIFICATION INERIS XXATEXXXXX IECEx INExx.xxx Resistant Resistant Resistant Resistant Resistant Resistant Resistant Maximum permissible surface temperature (DUST): T80 C / T0 C Temperature class (GAS): Protection degree: Impact Resistance: T4/T5 IP Switched socket outlets with Dissipative interlock material: Thermosetting (GRP) Sockets colour: Plugs material: Plugs colour: 7J Black RAL005 PA Dissipative Black RAL011 ADVANCEGRP[GD] Series OPTIMAEX[GD] Series ELECTRICAL PARAMETERS Size 1/32A 3A 1A Unit Category 400 500 0 415 500 0 0 V AC3 1 A AC22A 32 3 1 A AC23A 32 3 1 A 5

ADVANCEGRP[GD] Series OPTIMAEX[GD] Series ATEXIECEx SWITCHED INTERLOCKED SOCKET OUTLETS IP ADVANCEGRP[GD] Series 504. Poles Hz Volt Colour h. 1A 32A 3A 1A 1 1 1 1 100 4 504.170 504.3270 2000 504.183 504.3283 380415 504.178 504.3278 2P+E 480500 trasf. 7 12 504.183 504.3283 >300500 >50 2 504.1834 504.32834 c.c. >500 3 c.c. >0 8 100 4 504.172 504.3272 504.372 504.172 2000 504.174 504.3274 504.374 504.174 380415 504.18 504.328 504.38 504.18 0 44040 480500 11 7 504.185 504.18 504.3285 504.328 504.385 504.38 504.185 504.18 000 5 504.187 504.3287 504.387 504.187 50 0 380 440 3 504.184 504.3284 504.384 504.184 100300 >50 10 504.181 504.3281 504.381 504.181 >300500 >50 2 504.182 504.3282 504.382 504.182 100 4 504.17 504.327 504.37 504.17 2080 504.175 504.3275 504.375 504.175 34415 504.187 504.3287 504.387 504.187 480500 000 7 5 504.187 504.1877 504.3287 504.32877 504.387 504.3877 504.187 504.1877 0 44040 11 504.1875 504.32875 504.3875 504.1875 50 0 380 440 3 504.1874 504.32874 504.3874 504.1874 >300500 >50 2 504.1872 504.32872 504.3872 504.1872 Pack Quantity.

21. PLUGS IP OPTIMAEX[GD] Series PLUG ACCESSORIES PLUGS COVER ATEXIECEx 1A cable gland 10/40 21. 21.133 21.138 21.133 21.1332 21.1334 21.1338 21.131 21.134 21.13 21.135 21.13 21.137 21.134 21.131 21.132 21.132 21.135 21.137 21.137 32A cable gland 10/40 21.3230 21.3233 21.3238 21.3233 21.32332 21.32334 21.32338 21.3231 21.3234 21.323 21.3235 21.323 21.3237 21.3234 21.3231 21.3232 21.3232 21.3235 21.3237 21.3237 3A cable gland /24 21.331 21.334 21.33 21.335 21.33 21.337 21.334 21.331 21.332 21.332 21.335 21.3 37 21.337 1A cable gland 1/8 21.131 21.134 21.13 21.135 21.13 21.137 21.134 21.131 21.132 21.132 21.135 21.137 21.137 Description 1A/20A 2P+E 10/100 570.013 1A/20A 1A20A 10/100 570.014 1A/20A 10/100 570.015 32A/30A 32A30A 2P+E and 10/100 570.0324 32A/30A 10/100 570.03 3A0A 2P+E, and 10/100 570.03 1A100A 2P+E, and 10/100 570.1 SOCKET ACCESSORIES EARTH STUD Description Earth stud. 44.E50 AUXILIARY CONTACT ADVANCEGRP[GD] Series OPTIMAEX[GD] Series 21.1377 21.32377 21.3377 21.1377 21.1375 21.32375 21.3375 21.1375 21.1374 21.32374 21.3374 21.1374 21.1372 21.32372 21.3372 21.1372 CONFIGURATION SOCKET OPTIONAL ACCESSORIES 504. 183 E 2 EARTH STUD AUXILIARY CONTACT 1 = 1 NO 4 = 2 NC 2 = 1 NC 5 = 1 NO+1NC 3 = 2 NO 7

8 L L P P D C I G M M N N A B I/2 I/2 O Ø H H F E ATEXIECEx II 2GD [ ] ADVANCEGRP[GD] Series OPTIMAEX[GD] Series ADVANCEGRP[GD] SERIES DIMENSIONS 1A 32A 3A 1A 20 20 20 20 20 20 380 380 575 575 A TYPE 170 170 280 280 B 370 375 33 35 35 403 550 550 800 800 C min 280 282 282 285 285 28 420 420 2 2 D 170 175 182 18 18 185 2 2 3 3 E 1,8 1,8 1,8 1,8 1,8 1,8 205,75 205,75 0 0 F 114,5 114,5 114,5 114,5 114,5 114,5 150 150 7 7 G 7,75 7,75 7,75 7,75 7,75 7,75 8,3 8,3 11,5 11,5 H 7 7 Ø 18 18 18 18 18 18 310 310 48 48 I 234 I/2 31 31 31 31 31 31 35 35 54 54 L 32,5 32,5 50 50 M 32,5 32,5 N O 33,5 33,5 33,5 33,5 33,5 33,5 40 40 4 4 P 2P+E 2P+E

CROSS SECTIONAL AREAS CONDUCTORS & TORQUE TERMINALS CONTACTS TORQUE ADVANCE GRP[GD] In Cross Sectional Areas Conductors Tightening Torque (Nm) 1/32A EARTH TERMINALS AUXILIARY CONTACTS Cross Sectional Areas 10 mm² finelystranded 0.8 1 mm² singlewire 0.8 mm² finelystranded 2.5 3A 35 mm² singlewire 2.5 1A 50/70mm² finelystranded 3.5 EARTH TERMINALS CONTACTS TORQUE Type Cross Sectional Areas Conductors Tightening Torque (Nm) 1/32A 10/1mm² 1.2 3A Weidmuller Ex e terminal type WPE35 35mm² 3.5 1A 50/70mm² 3.5 In the sockets ADVANCE GRP[GD] type 1A, 32A, and 3A can be install as optional 2 auxiliary contacts maximum, on model type 1A is not possible to install auxiliary contacts. HOW TO INSTALL AUXILIARY CONTACT Insertion aux. contact "B" B They are optional accessories with ATEX/IECEx separate certificates. Installation and maintenance shall be done as prescribed by manufacturer documents. Insertion aux. contact "E" B ATEXIECEx ADVANCEGRP[GD] Series OPTIMAEX[GD] Series A A Insertion aux. contact "A" Insertion aux. contact "A" ADVANCE GRP[GD] 1/32A ADVANCE GRP[GD] 3A

ADVANCEGRP[GD] Series OPTIMAEX[GD] Series ATEXIECEx ELECTRICAL PARAMETERS AUXILIARY CONTACT ATEX Certification Auxiliary Contact Type V max I max Mode of protection (Nm) ATEX Certificate Ambient Temperature TECHNOR ZBWE 400V 4A Ex d e IIC INERIS 02 ATEX 007U 20 C / +0 C ZBWE 1 00V 4A Ex d e IIC INERIS 02 ATEX 007U 20 C / +0 C CORTEM M0530 M0531 400V 4A Ex d e IIC CESI 0 ATEX 01 U 40 C / +0 C IECEx Certification Auxiliary Contact only for 3A size Type V max I max Mode of protection (Nm) ATEX Certificate Ambient Temperature CORTEM M0530 M0531 400V 4A Ex d e IIC IECEx CES 11.0031U 40 C / +0 C The ambient temperature range will be limited by the components (Auxiliary contacts) with lowest rating. Refer to the label on the specific products. The ambient temperature is marked on the label and should not be used outside this range. DRILLING AREA The drilling area have to drilled respecting the minimum distance, and diameters e number of maximum hole indicated in table 2 (Clearance). Drilling Area Cable gland Clearance Socket Size Dimensions size a b 80x45mm 1/32A 20mm mm 32mm 21mm 2mm 33mm 3mm 4mm 5mm a Gland 110x55mm 1/32A mm 32mm 40mm 2mm 33mm 41mm 4mm 5mm 70mm 1x72mm 1A top side (A) mm 32mm 40mm 50mm 2mm 33mm 41mm 51mm 4mm 5mm 70mm 78mm 72x72mm 1A bottom side (B) mm 32mm 40mm 50mm 2mm 33mm 41mm 51mm 4mm 5mm 70mm 78mm b Clearance Only for ADVANCEGRP[GD] 3A and 1A needs to check carefully the installation when cable entry coming from the bottom side. 10

L OPTIMAEX[GD] SERIES DIMENSIONS ØG TECHNICAL FEATURES A ØMAX ØMIN PLUG SERIES OPTIMAEX Unit Value Rated Current 1A 32A 3A 1A Code 21.1... 21.32... 21.3... 21.1... Suitable Size cables GroundTerminals IP 1A 32A 3A 1A TYPE 2P+E 2P+E A Min øg L Min ø Min ø Max 11 123 140,5 142, 142, 150 1,5 1,5 214,5 214,5 73 81 88 2 2 101 112 112 128 128 140,5 147,5 15 174 174 180,5 217,5 217,5 274 274 (mm 2 ) 4 10 1 50 13 17 17 2 2 15 15 20 20 20 23 33 33 50 50 ATEXIECEx ADVANCEGRP[GD] Series OPTIMAEX[GD] Series Power Supply Terminals TighteningTorque (Nm) 1 1.5 2 4 Cable size accepted by CableClamp (eg.h07rnf) Cable Gland/CableClamp TighteningTorque (mm) (Nm) 2P+E 15 20 15 20 20 1323 2P+E 17 33 2 50 5, 5, 11 CableGland/CableClamp (Screw) TighteningTorque (Nm) 0.8 0.8 0.8 0.8 Handle Screws TighteningTorque (Nm) 1 1 1,2 1,2 11

Click&Go ZP0022GB1 www.scame.com/en/prodotto ser/sysadvgrp_ex.asp Argentina Bosnia Herzegovina Brazil Chile China Croatia Czech Republic France India Poland Portugal Romania Slovakia Spain U.A.E. United Kingdom Uruguay Ukraine ScameOnLine www.scame.com atex@scame.com SCAME PARRE S.p.A. VIA COSTA ERTA, 15 24020 PARRE (BG) ITALY TEL. +3 035 705000 FAX +3 035 703122