INSTALLATION & OPERATION MANUAL MagIQtouch BMS Industrial Controller MS1 (Coolers Only)

Similar documents
APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10)

BULK FOOD TROLLEY MODEL BFT-150-E

c-go 24V/6A 24V/8A 24V/12A

MULTI FUNCTION POWER PAK PLUS

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

GLM SERIES CONTROL Users Manual Rev:

Installation and Operation Instructions

Domestic Water Supply Pressure Pumps

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

BATTERY CHARGER BTC-1005A

Gator Pet 18V Let s get started

Electrical Safety CSA Z462 & NB Regulations

Fault Codes. J control

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Manual. Curtis Model 1625 Battery Charger. Curtis Instruments, Inc. 200 Kisco Avenue Mt. Kisco, NY

Installation manual ACO Mains operated drain doser (MODD) for Grease Traps

30A SMART ENERGY MANAGEMENT SYSTEM TM

INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT

SSV2BR INSTRUCTIONS INSTALLATION INSTRUCTIONS

Installation Instructions & Users Manual

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

Sectional And Tilting Door Opener

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

FlushMaster Cistern & Valve assembly

AirTMCordless HANDHELD

Sectional and Tilting Door Opener

Porte 150 Users Manual Swing Gate Opener 24V DC

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Operating instructions in the back. PD1820LF

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

Micro. Fully charged. Charging Keepower MICRO Nominal battery voltage 12V Charge current 0.8 A. Keepower Battery Charger.

12V 160A/24V 185A MANUAL WORKSHOP BATTERY CHARGER

User Manual. Solar Charge Controller 3KW

Aurora Wind Interface Box

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33

Operating instructions in the back. PD1420LP

User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T/EVC30T-IN

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC DIMMER CONTROLLER BY BROMIC IMPORTANT

ELECTRICAL SYSTEM RP-7

12/24V 30A AUTOMATIC/MANUAL WORKSHOP BATTERY CHARGER

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

Rolling Door Opener INSTALLATION INSTRUCTION AND OWNERS MANUAL

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

REMOTE POWERING Central Energy System ( HUB )

MRXBOX-VSC Visual System User Control Installation and Maintenance

INTELLI-POWER BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE. P/No.s IC700, IC700W, IC1000, IC1500

Troubleshooting Manual

PHV V NT VERTICAL AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Section 3 Technical Information

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

Battery Charger JCB- SCH20LI.2

Air duct switching damper

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

INTELLI-CHARGE BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE

Flight Systems. Replacement for KASSEC DESCRIPTION

Battery Charger JCB-FCH20LI2

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

DRENOX IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

AXA DALI P20. DALI Broadcast Controller. Installation Manual

PRESSURE BOOSTER 150

User Manual Solar Charge Controller 3KW

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS

Freedom egen System End-of- Line Functional Checklist

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

KEWTECH. KT56 digital multi function tester. Instruction manual

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

8-STAGE AUTOMATIC BATTERY CHARGER MCU CONTROLLED - HIGH FREQUENCY SWITCHMODE MODELS: KACHG1207, KACHG1212, KACHG1220, KACHG2410. Instruction Manual

Power and Cooling. Chassis Power System

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

INSTRUCTION & INSTALLATION

Technical Manual. DLM Module. This manual should remain with the unit.

C3 Operating Instructions

Solar Hybrid Inverter SP Brilliant Grid Series

B 3000 Instant Chilled Filtered Water System. User guide

GCU-10. Automatic Engine Control Unit Operators Manual

SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0

Sectional and Tilting Door Opener Installation Instructions and User Guide

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

3 Phase Smart Controller

INDUS rail /

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

2.0Ah BATTERY INSTRUCTION MANUAL

Guidance to Installers of Viridian EV Charging Stations

Multi-Mover Charger for model L25

Breezair TBA 550 Installation Manual

Power Connect TM Series RX60

BATTERY METER SMART BATTERY GUAGE

PowerOhm Installation Manual for BM R Series Braking Modules

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User manual. Minivator Limited 82 First Avenue Pensnett Estate Kingswinford West Midlands DY6 7FJ England

OpenEVSE - 40A Charging Station

HPP1 MK5 Owner s Manual

Installation Instructions for Load Management Kit A051C329

Cordless Rechargeable Saw Instructions for Use

DOC # DOCSST-D 08/16/99

Transcription:

INSTALLATION & OPERATION MANUAL MagIQtouch BMS Industrial Controller MS1 (Coolers Only) BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 0VDC ACTUAL FAN ERROR SET FAN (English) (Industrial Controller MS1) BMS INDUSTRIAL CONTROLLER MS1 M1 TM Original English Instructions

i

TABLE of contents KIT CONTENTS 2 SAFETY 3 EMPLOYER AND EMPLOYEE RESPONSIBILITIES 3 Installer and Maintenance Contractors Risk Assessment 3 Other Important Points to Consider: 3 INSTALLATION PREPARATION 4 COMMUNICATION CABLE 5 Master Mode - Maximum Cable Length 5 Slave Mode - Maximum Cable Length 5 INSTALLATION 7 Mounting - Din Rail 7 Mounting - Wall Mount 7 ELECTRICAL INSTALLATION 8 Typical Installation Options 8 Master Mode - Single Cooler 8 Master Mode - Multi Coolers 8 Slave Mode - Single Cooler Option 1 9 Slave Mode - Single Cooler Option 2 9 Slave Mode - Multiple Coolers Option 1 10 Slave Mode - Multiple Coolers Option 2 10 Master Or Slave Mode 11 Master Mode 11 Slave Mode 11 Activating Master Or Slave Mode 11 Connecting Cooler or Wall Control to BMS MS1 12 Inputs Signals 13 Voltage Levels for Set Fan Speed Analogue Input. 14 Output Signals 14 Error Status 15 Actual Fan Speed 16 Diagnostic LED's 17 CONNECTION DIAGRAM 18 TROUBLE SHOOTING 19 MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL 1

(Coolers Only) BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 KIT CONTENTS Contents Item Images Qty Description BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 1 1 MaglQtouch Industrial Controller MS1 0VDC ACTUAL FAN ERROR SET FAN MagIQtouch BMS Industrial Controller MS1 2 1 Installation and Operation Manual ACTUAL FAN SET FAN 0VDC ERROR TM BMS INDUSTRIAL CONTROLLER MS1 M1 (English) (Industrial Controller M1) Original English Instructions INSTALLATION & OPERATION MANUAL 3 2 Wall Brackets 4 2 Wall Plug Yellow 5mm 5 2 Screw PAN PHIL 6ABX1 ZNP 6 1 3m Communications Cable ILL2109-A 2

SAFETY This document provides technical guidance on the installation and operation of the MagIQtouch BMS Industrial Controller MS1. EMPLOYER AND EMPLOYEE RESPONSIBILITIES Please read this manual carefully. Your failure to do so could result in injury to you or damage to the cooler and property. The installation and maintenance of coolers at height has the potential to create Occupational Health and Safety issues for those involved. Installers are advised to ensure they are familiar with Local Acts, Regulations and Standards, which may offer practical guidance on health and safety issues. Compliance with these regulations will require appropriate work practices, equipment, training and qualifications of workers. INSTALLER AND MAINTENANCE CONTRACTORS RISK ASSESSMENT Seeley International provides the following information as a guide to contractors and employees to assist in minimising risk whilst working at height. A risk assessment of all hazardous tasks is required under legislation. A risk assessment is an essential element that should be conducted before the commencement of work, to identify and eliminate the risk of falls or to minimise these risks by implementing control measures. There is no need for this to be a complicated process, it just is a matter of looking at the job to be done and considering what action(s) are necessary so the person doing the job does not injure themselves. This should be considered in terms of: What are the chances of an incident happening? What could the possible consequence be? What can you do to reduce, or better still, completely get rid of the risk? Other important points to consider: This MagIQtouch BMS Industrial Controller is to be installed indoors only, installation shall only be performed by suitably trained and qualified personnel, in accordance with local and national wiring rules. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. If any cables are damaged, they shall be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard. Stranded conductors shall not be consolidated by lead-tin soldering where they are subject to contact pressure, i.e on terminal block. The MagIQtouch BMS Industrial Controller has a 12Vdc input and output Safety Extra Low Voltage (SELV) circuit, this should only be connected to other SELV circuits. MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL 3

INSTALLATION PREPARATION WARNING! THIS INSTALLATION SHOULD ONLY BE PERFORMED BY SUITABLY TRAINED AND QUALIFIED PERSONNEL, IN ACCORDANCE WITH LOCAL AND NATIONAL WIRING RULES. Before commencing work on the cooler, ensure it is disconnected from the power source, when installing the MagIQtouch BMS Industrial Controller select and prepare an appropriate mounting site with the following features: Space for mounting on either DIN rail or directly to the wall. Clearance for inserting digital & analogue inputs & outputs. Within 100m of cooler. Dedicated 12Vdc power input for "Actual" fan speed and logic Error Status signal. Note! Do not use power boards and double adaptors! 4

BMS INDUSTRIAL CONTROLLER MS1 M1 COMMUNICATION CABLE The communication cable from the Cooler Controller to the MagIQtouch BMS Industrial Controller are 26AWG, 7/0.16, 6 core flat cable. 20m/66 cable is supplied with each Seeley cooler or heater. Important! Supplied cables should not be altered. Failure of the product or components to operate correctly due to modification to supplied cables, or the use of non-approved cable will NOT be accepted under the Manufacturer s warranty. MASTER MODE - Maximum cable length BMS INDUSTRIAL CONTROLLER MS1 M1 Seeley International cooler 0VDC ACTUAL FAN ERROR SET FAN 100m / 328' MAX ILL2472-A SLAVE MODE - Maximum cable length 20m / 66' MAX Seeley International cooler 0VDC ACTUAL FAN ERROR SET FAN 20m / 66' MAX 3m / 10' MAX LINK MODULE ILL2481-A MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL 5

COMMUNICATION CABLE cont. Should your installation require addition cables, 'genuine' Seeley International components can be ordered as follows; Part No. Length Details 862873 1.5m/5' MagIQtouch Industrial Wall Controller cable (No ferrite) 861265 3m/10' MagIQtouch Industrial Wall Controller cable (No ferrite) 833880 20m/66 MagIQtouch Industrial Wall Controller cable (No ferrite) 823553 20m/66 MagIQtouch Industrial Wall Controller cable (ferrite) 864396 30m/98 MagIQtouch Industrial Wall Controller cable (ferrite) 864402 40m/131 MagIQtouch Industrial Wall Controller cable (ferrite) 834238 60m/197' MagIQtouch Industrial Wall Controller cable (No ferrite) 834474 500m/1640' Roll of 6 core ribbon cable with no terminations or plugs Plug Type = 6 pin Farnell 781-289, wired as below. 670423 Hinged Bracket Ferrite WHITE BLACK RED GREEN YELLOW BLUE ILL2123-A 6

INSTALLATION MOUNTING - DIN RAIL BMS MS1 is suitable for internal installations only. The MagIQtouch BMS Controller is fitted with a DIN rail retainer on the rear of the enclosure. Locate the top catches onto the rail first, pivot down then secure the bottom catches onto the rail where the DIN rail retainer will click into place. ILL2103-A MOUNTING - WALL MOUNT BMS MS1 is suitable for internal installations only. Within the MagIQtouch BMS Industrial Controller kit are 2 x wall brackets, push fit them into the each side of the enclosure base. Mark and drill suitable holes in wall and insert wall plugs provided. Align and screw the MagIQtouch BMS Industrial Controller on to the wall. BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 0VDC ACTUAL FAN ERROR SET FAN ILL2104-A MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL 7

BMS INDUSTRIAL CONTROLLER MS1 M1 BMS INDUSTRIAL CONTROLLER MS1 M1 BMS INDUSTRIAL CONTROLLER MS1 M1 BMS INDUSTRIAL CONTROLLER MS1 M1 ELECTRICAL INSTALLATION TYPICAL INSTALLATION OPTIONS Installation of the cooler, wall controller and MagIQtouch BMS Industrial Controller must conform to local, national and international electrical safety and wiring regulations. Refer to the cooler installation manual for installation and electrical connection of cooler. MASTER MODE - SINGLE COOLER NOTE: 1 x BMS MS1 Master per 1 x cooler EVAP COOLER 1 100m BMS MS1 0VDC ACTUAL FAN ERROR SET FAN CUSTOMER BMS ILL2474-B MASTER MODE - MULTI COOLERS NOTE: 1 x BMS MS1 Master per 1 x cooler EVAP COOLER 1 EVAP COOLER 2 EVAP COOLER 3 0VDC ACTUAL FAN ERROR SET FAN 0VDC 100m ACTUAL FAN ERROR SET FAN 0VDC ACTUAL FAN ERROR SET FAN 100m 100m CUSTOMER BMS ILL2475-B 8

BMS INDUSTRIAL CONTROLLER MS1 M1 BMS INDUSTRIAL CONTROLLER MS1 M1 ELECTRICAL INSTALLATION cont. SLAVE MODE - SINGLE COOLER option 1 EVAP COOLER 1 3m 20m LINK MODULE CUSTOMER BMS 20m BMS MS1 0VDC ACTUAL FAN ERROR SET FAN ILL2476-B SLAVE MODE - SINGLE COOLER option 2 EVAP COOLER 1 20m 20m BMS MS1 0VDC ACTUAL FAN ERROR SET FAN CUSTOMER BMS ILL2477-B MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL 9

BMS INDUSTRIAL CONTROLLER MS1 M1 ELECTRICAL INSTALLATION cont. SLAVE MODE - Multiple Coolers Option 1 (With link modules) SLAVE MODE - Multiple Coolers Option 2 (With Dual RJ socket on Cooler electronics) ILL2478-B EVAP COOLER 1 EVAP COOLER 2 EVAP COOLER 3 20m UP TO 135 COOLERS LINK MODULE BMS MS1 20m CUSTOMER BMS 20m 20m 3m 20m AIR SENSOR 0VDC ACTUAL FAN ERROR SET FAN ILL2479-C 10

ELECTRICAL INSTALLATION cont. Master or Slave Mode The BMS MS1 controller can be used as either a 'Master' or 'Slave' Controller. Master Mode The BMS MS1 is controlled with BMS signals only and no MagIQtouch wall controller can be used. Only 1 x BMS MS1 per 1 x cooler can be used in this configuration. Slave Mode The BMS MS1 controller is a 'Slave' to the MagIQtouch wall controller. When the BMS MS1 'ON/OFF' signal is 'ON' the BMS MS1 controller takes control of the MagIQtouch wall control remotely. During remote access the MagIQtouch wall control will display "BMS CONTROL" and will not be operational. Activating Master or Slave Mode Remove the front cover of the BMS MS1 controller and set the dip switch to the requirements of your installation. Master Mode Slave Mode ILL2480-A MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL 11

ELECTRICAL INSTALLATION cont. CONNECTING COOLER OR WALL CONTROL TO BMS MS1 ILL2481-A 12

ELECTRICAL INSTALLATION cont. S NALS 0VDC SET FAN ILL2482-A Name Label Function Low High Input Type On/Off Operation Mode Fan Speed ON COOL SET FAN Master mode only: Turn Cooler On or Off Slave mode only: Switch operation between Wall control and BMS Cool or Vent Recommended voltage level for digital inputs. Cooler Off Cooler On Digital 10Vdc MagIQtouch Control Fan Only BMS Control Cool Mode Set speed from 1-10 N/A N/A Logical Level Min Typ. Max Unit Low 0 2 Vdc High 4 10 12 Vdc Digital 10Vdc Digital 10Vdc Analogue 0-10Vdc MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL 13

ELECTRICAL INSTALLATION cont. S NALS - ANALOGUE Recommended voltage levels for Set Fan Speed analogue input. Set Fan Speed Increasing (0-10) Decreasing (10-0) 0 0 1 2.8 2.2 2 3.6 2.8 3 4.4 3.6 4 5.2 4.4 5 6.0 5.2 6 6.7 6.0 7 7.5 6.8 8 8.2 7.5 9 9.0 8.3 10 10.0 NALS - ERROR IN 12V R15 4K7 1 R22 470R D3 R18 ERROR + RXE005 3 B Q1 BC640 2 C E ISMA4753 ERROR - IN 0V ILL2483-B This circuit can be used in two ways depending if the optional IN 12V input is connected (12V_EXT 0V_EXT on the diagram). 14

ELECTRICAL INSTALLATION cont. NALS - ERROR CONT. - When the 12Vdc power input is not connected, the output can be used in open collector mode with either a pull-up load or Relay coil to the BMS power rail. BMS DC RAIL V+ BMS DC RAIL V+ BMS MS1 MODULE ERROR+ ERROR- BMS 0V PULL UP RESISTOR Monitor Voltage: V+ =NoError V- =Error RELAY COIL Normally Open contacts1 BMS MS1 MODULE ERROR+ ERROR- BMS 0V Contact open = No Error Contact closed = Error ILL2484-B - When the 12Vdc power input is connected, the output will be a signal that can be directly monitored. BMS MS1 MODULE ERROR+ ERROR- Monitor Voltage: V+ =NoError V- =Error ILL2485-B MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL 15

ELECTRICAL INSTALLATION cont. NALS - ACTUAL FAN cont. Actual Fan Speed VOUT min VOUT typ VOUT max 0 0.0 0.8 1.0 1 1.0 1.3 1.6 2 1.7 2.2 2.5 3 2.7 3.2 3.5 4 3.7 4.2 4.5 5 4.7 5.2 5.5 6 5.7 6.2 6.5 7 6.8 7.2 7.5 8 7.8 8.2 8.6 9 8.8 9.3 9.6 10 9.8 10.3 12.0 Exact voltage levels may differ depending on the precision of the IN 12V supply. [Optional] 12Vdc power input ( IN 12VDC) Power input only required if ACT FAN and ERROR signals are required from the module. If Power input is not connected, ERROR can still be used in open collector mode. However, ACT FAN will not work. Min Typ. Max Unit Voltage DC 11.5 12 12.5 V 16

DIAGNOSTIC LED's LED Diagnostic and cooler operating information can be viewed from the MagIQtouch BMS Industrial Controller via the Error Code LED's. When power is applied to the RJ port of the BMS module MS1 and no error is detected the LED will illuminate continuously. If an error is detected by the controller, the ERROR LED will start illuminating on the front panel. The type of error will be indicated by the sequence of flashes highlighted on LED. Errors can be cleared by applying a low level and then high level on the ' ON '. Error codes can be cleared using the "RESET" button on the front of the controller. OFF: BMS Module Off (no power received from Cooler on RJ port). ON: BMS is operational (Communication to Cooler and Wall Control OK, Cooler has no faults). Flashing: cooler has a fault, number of flashes corresponds to Fault Code (i.e.: 2 flashes => FC02). 0VDC ACTUAL FAN ERROR SET FAN ILL2108-A Part No. Error 1 Flash Fault Code #1 Communication Failure. 2 Flashes Fault Code #2 Failure to Detect Water at Probes. 4 Flashes Fault Code #4 Failure to Clear Probes during drain. 7 Flashes Fault Code #7 Motor Fault NOTE: Error Codes can vary between products. Refer to the cooler Installation Manual. MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL 17

CONNECTION DIAGRAM 12V 12V FAN + FAN - ON + ON - COOL + COOL - POT SWITCH SWITCH POT SWITCH SWITCH ERROR + ERROR - ACT FAN + ACT FAN - Monitor Voltage: V+=NoError V-=Error Monitor Voltage: Checktable for ACT FAN PULL UP RESISTOR 10K ACT FAN not available Monitor Voltage: V+=NoError V- =Error IN12V 12V notconnected IN0V 0V CONFIGURATIONA With IN 12V connected 0V CONFIGURATIONB With IN 12V NOT connected ILL2512-A 18

TROUBLE SHOOTING Symptom Cause Action The PWR LED is not illuminated. The PWR LED is flashing (1-flash sequence). Cable not connected correctly Cable damaged or broken. The BMS MS1 configured in incorrect mode (Master/Slave). Cable not connected correctly Cable damaged or broken. Refit cable. Cycle power to cooler. Replace cable. Cycle power to cooler. Open enclosure and correct dipswitch position. Cycle power to Cooler. Refit cable. Cycle power to cooler. Replace cable. Cycle power to cooler. The PWR LED is flashing (multiple flashes sequence). The PWR LED is illuminated but the Cooler is not starting. The ACT FAN signal stays always low. The cooler has a fault. The ON input is not set to High. The 12VDC power input is not connected. Refer to cooler manual to solve the fault on the cooler. Cycle power to cooler. Set ON input signal to High. Connect 12VDC between IN 12VDC and IN 0VDC. MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL 19

Warranty Service Australia 1-300-650-644 Technical Support Australia 1-300-650-399 For regions outside Australia: Contact your local Dealer seeleyinternational.com MANUFACTURED BY: SEELEY INTERNATIONAL PTY LTD 112 O SULLIVAN BEACH RD, LONSDALE SA, 5160. AUSTRALIA IMPORTED BY: SEELEY INTERNATIONAL (EUROPE) LTD 5 PAPPLEWICK LANE, HUCKNALL, NOTTINGHAM, NOTTINGHAMSHIRE, NG15 7TN, UNITED KINGDOM SEELEY INTERNATIONAL (AMERICAS) LTD 1002 S 56TH AVENUE, SUITE # 101 PHOENIX, ARIZONA 85043, USA SEELEY INTERNATIONAL (AFRICA) PTY LTD 6 WITTON ROAD, FOUNDERSVIEW SOUTH, MODDERFONTEIN 1609, GAUTENG, SOUTH AFRICA It is the policy of Seeley International to introduce continual product improvement. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected. 865448-C seeleyinternational.com AU 1704