Installing and Removing Power Supplies

Similar documents
Installing Power Components

Installing the Switch

Installing the Switch Chassis

Switch Installation. Preparing for Installation. Warnings CHAPTER

Installing the ONS M6 Shelf

Connecting to DC Power

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

Installing the Air Flow Regulator

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

Cisco ASR 1002 Router Overview and Installation

MODEL ELC-12/60-D BATTERY CHARGER

Cabinet and Rack Installation

TOYOTA TUNDRA HANDS FREE BLU LOGIC Preparation

HP Modular Cooling System 200/100 Options Installation Guide

Cabinet and Rack Installation

Manual. Curtis Model 1625 Battery Charger. Curtis Instruments, Inc. 200 Kisco Avenue Mt. Kisco, NY

TOYOTA CAMRY HANDS FREE BLU LOGIC Preparation

3-Phase 10-Slot Power Supply System USER GUIDE

REMOTE POWERING Central Energy System ( HUB )

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit

TOYOTA VENZA HANDS FREE BLU LOGIC Preparation

Preparing the Site. Information About the Site Requirements CHAPTER

Cisco Nexus 9396PX Switch Site Preparation and Hardware Installation Guide

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

SWX-100-INT-PCR Internal Isolation Switch

Mounting an EX 8200 series Switch on a Rack or Cabinet Without Using a Mechanical Lift

Install the Shelf and Common Control Cards

Power and Cooling. Chassis Power System

Legacy Installation Manual

SCION XB HANDS FREE BLU LOGIC Preparation

Cabinet and Rack Installation

GE Programmable Control Products. PACSystems* RX3i Rackless Energy Pack IC695ACC403 Quick Start Guide. GFK-3000 December 2016

E-Series and EF-Series Systems

M100F Incremental Motor Actuator R81F Interface Board

GMT Fuse Panel Installation Guide

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

DPoE Power System. User Manual

EB Conveyor Maintenance Guide

Replacing the Battery in the Patriot SPS 250, SPS 300 and SPS 450

Custom Dynamics Spyder Stingerz Installation Instructions

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

TOYOTA TACOMA HANDS FREE BLU LOGIC Preparation. Item 5 Item 6 Item 7 Item 8. Item 4. General Applicability Note: Recommended Tools

Setup, Assembly, & Adjustment

Model 1672, 1673 Triple Output Power Supply

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A

INSTALLATION INSTRUCTIONS

160S Rewind Option Kit Installation Instructions

AIS and 40 kva 400 V. Site Preparation and Installation Manual

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

Installation of Raxiom Switchback Turn Signal Conversion Kit w/resistors

RSA5UP Option 53 RSA5100A Series Real-Time Signal Analyzers Memory Extension, 4 GB Acquisition Memory Total Upgrade Instructions

GPS Steering System Installation Manual

TT /17 INSTALLATION INSTRUCTIONS. Introduction. Required Tools and Equipment

CAUTION. Even Brakes with a black cable need second vehicle kit Even Brakes with a blue cable need second vehicle kit 98450

SCION TC HANDS FREE BLU LOGIC Preparation

Foreword

Model Fixed Rack-Mount Kit

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

GPS AutoSteer System Installation Manual

Installation instructions

* * APPLICABLE MODELS: 2014 > Mazda 3

TOYOTA tc HANDS FREE BLU LOGIC Preparation

* * APPLICABLE MODELS: 2014 > Mazda 6

TOYOTA TUNDRA TVIP V4 Preparation

Powerware Battery Charger Module. User s Guide. Models ASY-0652 and ASY

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

INSTALLATION INSTRUCTIONS

User s Manual. Automatic Switch-Mode Battery Charger

Cabinet and Rack Installation

CANVAS DOOR KIT P/N , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

Chapter 8 Interior Wiring and Lighting

TPM/GMT Panel Installation Guide

* * APPLICABLE MODELS: 2017 > CX-5

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

Triple Output Power Supply

SPECTRACOOL Slim Fit Air Conditioners (Surface-Mount Units Only) Quick Start Operation Guide

Plasma Display Electric Pop-Up Lift (PUL)

S6 BATTERY REPLACEMENT

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Carousel Unit User Manual Replacing the Check Stand Motor

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

Pole Mount COD Installations (PMCOD)

INSTALLATION INSTRUCTIONS

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Electric Range installation manual

Installation and Service Manual

Conflicts: JBL Audio, Factory Navigation, Accessory XM Satellite Radio, and Accessory Sirius Satellite Radio

Switching DC Power Supply

GENUINE PARTS INSTALLATION INSTRUCTIONS

Ignition Lock Cylinder

Replacing an IOTA Load Center (ILC) 3045 Charger with an IOTA DLS or DLS-X

INSTALLATION INSTRUCTIONS

Lifeline Medical Systems

IMPORTANT SAFEGUARDS

Handyman Motor Capacitor Meter PART NO

INSTALLATION INSTRUCTIONS FOR FACTORY MUTUAL APPROVED INSTRUMENTS

Transcription:

Power Supply Overview, page 2 Installing Power Supplies, page 3 Removing Power Supplies, page 8 Finding the Serial Number, page 9 1

Power Supply Overview Power Supply Overview You can install two types of power supplies in the chassis: Figure 1: Cisco Catalyst 6840-X AC Input Power Supply Figure 2: Cisco Catalyst 6840-X DC Input Power Supply The switch chassis has two slots in which you can install power supplies using any of the following combinations: Two AC-input power supplies 2

Installing Power Supplies Two DC-input power supplies One AC-input power supply and one DC-input power supply One AC-input power supply (leaving the blank cover on the other slot) One DC-input power supply (leaving the blank cover on the other slot) Note If you leave any power supply slots empty, you must ensure that the blank cover is installed in that slot to maintain the designed airflow. This table lists the power supply models. Part Number C6840-X-750W-AC= C6840-X-750W-DC= C6840-X-1100W-AC= C6840-X-1100W-DC= Description Cisco Catalyst 6840-X power supply AC-750W Cisco Catalyst 6840-X power supply DC-750W Cisco Catalyst 6840-X power supply AC-1100W Cisco Catalyst 6840-X power supply DC-1100W The power supplies can work together in Redundant Mode, in which each power supply operates at approximately 50 percent of its capacity, no greater than 60 percent and no less than 40 percent. If one power supply fails, the other power supply can provide power for the entire system on its own. This is the default and recommended mode for production. Installing Power Supplies Before You Begin You follow the same steps to install the AC-input and DC-input power supplies, but you must ground them differently. The switch chassis must be installed in a cabinet or rack that is secured to the data center. Remove the power supply from its shipping container and remove any packaging. You need the following additional tools and equipment: Nut driver attachment for number 1 Phillips-head screwdriver or ratchet wrench with torque capability (used only for DC-input power supplies). For the DC-input power supply, you need four power cables sized to reach the DC power source or power interface unit (PIU). Grounding wire Size this wire to meet local and national installation requirements. For U.S. installations, you must use a 8-24 AWG copper conductor. For installations outside the U.S., 3

Inserting the Power Supply consult your local and national electrical codes. The length of the grounding wire depends on the proximity of the switch to proper grounding facilities. Inserting the Power Supply To insert the power supply into the chassis, follow these steps: Procedure Step 1 Step 2 Step 3 Step 4 Remove the blank cover and store it for future use. Verify that the power supply is not connected to any power sources. Hold the handle on the power supply with one handand position the power supply with its back end at the open power supply bay. See the figure for an example (AC power supply is shown as an example, DC power supply can be installed in the same way). Slide the unit all the way into the power supply bay until the release latch on the front of the power supply clicks and prevents you from moving the power supply in or out of the chassis. Figure 3: Installing the Power Supply 1 AC power supply Connecting to the Power Source You follow the same steps to install the AC-input and DC-input power supplies, but you must ground them differently. 4

Connecting to the Power Source AC-input power supply It is automatically grounded when you connect its power cable to the power supply and the power source. DC-input power supply You do not connect the power supply directly to the earth ground. You use one power cord for each power supply to connect the power supply to its power source. Before You Begin Before you connect power supplies to power sources, ensure the following: The chassis is connected to an earth ground. See Establishing the System Ground. You have receptacles for the power sources within reach of the power supply cables. If you are connecting to a DC power, check that you are using 8-24 AWG power cables to connect to the power supply. The 8-24 AWG wire size applies to the negative [-], and positive [+] cables that connect to negative and positive apertures on the connector. You have to procure the power cable. If you are installing more than one DC-input power supply, each must be protected by a dedicated circuit breaker or a fuse that is sized according to the power supply input rating and the local or national electrical code requirements. The power sources are rated as follows: For North American AC-input installations 10 A with 110 V circuits. For North American DC-input installations ( 48 VDC nominal at 37 A in North America (operating range: 40.5 to 56 VDC). For international installations Size the circuits by local and national standards. The power supply is already inserted into the chassis. Caution Ensure that the power source is OFF. As an added precaution, place the appropriate safety flag and lockout devices at the source power circuit breaker, or place a piece of adhesive tape over the circuit breaker handle to prevent accidental power restoration while you are working on the circuit. Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. Statement 1003 Connecting to an AC Power Source To connect to a power source, follow these steps: Warning Take care when connecting units to the supply circuit so that wiring is not overloaded. Statement 1018 5

Connecting to the Power Source Procedure Step 1 Step 2 Step 3 Plug the power cable into the power supply. Plug the other end of the power cable into an power source supplied by the data center. Note When using redundant mode, connect each power supply to a separate power source. Verify that the power supply is receiving power and outputting DC power by checking that the OK LED is on and is not yellow or blinking green. For an explanation of all the power supply LEDs and the conditions that they indicate, see Power Supply LEDs. When you first activate the power supply, you can verify the functionality of the LEDs by checking that each LED turns on for a couple of seconds. If the OK LED is flashing green, check the AC power connections on the power supply and the AC power source. Connecting to a DC Power Source Before you connect DC power supplies to power sources, you need to attach the DC connection wires to the DC power connector. To wire the connector: Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit.statement 1003 Warning Hazardous voltage or energy may be present on DC power terminals. Always replace cover when terminals are not in service. Be sure uninsulated conductors are not accessible when cover is in place. Statement 1075. 6

Connecting to the Power Source Procedure Step 1 Step 2 Step 3 Step 4 Step 5 Turn off the power at the circuit breakers for the portions of the DC grid power that you are connecting to and verify that all of the LEDs on the power supplies are off. Using a 1/8" flat head screwdriver or No. 1 Phillips head screwdriver, loosen the set screws on the connector to freely accept the power wires. The connector will accept 8-24 AWG wires, use what your local electrical code calls for. Strip 1/2" of insulation off the DC wires that you are using. Insert the black (DC negative) wire into the right aperture on the connector and tighten down the connection set screw. Finger tight or about 3 ft./lbs should be sufficient. Insert the red (DC positive) wire into the left aperture on the connector and tighten down the connection set screw. Do not tighten over 0.7 Nm. Figure 4: Connecting to a DC Power Source Step 6 For the powered down circuits connected to the power supplies, turn on the power at the circuit breaker. The LEDs should flash and then the INPUT OK LED on the power supply should turn on. 7

Removing Power Supplies Removing Power Supplies Procedure Step 1 Step 2 Turn off the power to the power supply that you are removing, as follows: a) If you are removing a DC-input power supply, ensure that the power is turned off at the power source by turning off the power for that circuit. Detach the power and ground cables, as follows: For the AC-input power supply, unplug the power cables that are attached to the power supply and the power source. For the DC-input power supply, remove the power cables from the power source. Step 3 Remove the power supply from the chassis, as follows: a) Press the ejector latch on the right of the power supply. b) Pull the power supply partially out of the slot by its handle. c) Pull the power supply fully from the slot. Caution If you intend to operate the switch without installing another power supply in the empty slot, then you must reinstall the blank cover over the empty power supply slot to ensure proper air flow in the system and for safety reasons. 8

Finding the Serial Number Finding the Serial Number If you contact Cisco Technical Assistance, you need to know the serial number. These figures show where the serial number is located. You can also use the show version privileged EXEC command to see the serial number. Figure 5: Serial Number on the AC Power Supply 9

Finding the Serial Number 10