Load cells. Data sheet. Special features. Cable assignment (six wire configuration)

Similar documents
HLC A1... HLC B1... HLC F1...

HLC A1... HLC B1... HLC F1...

PW29... Data Sheet. Single point load cell. Special Features. Optional: Dimensions (in mm; 1 mm = inches) B en

Presented By. NicolScales.com Contact Us

Load cell PR for maximum corrosion resistance. Load cell PR 6212 benefits. Mounting kit PR 6012 benefits

Compression load cell Inteco, converter Connexx, mounting kits PR 6001, PR 614x

Surface thermocouple Model TC50

SLB415 Load Cell. Global Usage No Compromise on Performance. SLB415 Beam Load Cells Cost Efficient Solution

0745A Load Cell. Global Usage Fully Approved for Accuracy and Safety. 0745A Beam Load Cell Fully Approved

Measuring insert for process resistance thermometer

SWC515 PinMount. Right the First Time Safe, Accurate, Service Friendly. SWC515 PinMount. Right the First Time

Cable resistance thermometer Model TR40

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

SWB505 MultiMount EN1090

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Resistance thermometer Without thermowell Model TR10-H

Load disconnect switch Series 8146/5-V11

SLB515 Load Cell. Global Usage Fully Approved for Accuracy and Safety. SLB515 Beam Load Cell Fully Approved

Type Electronic Limit Switch

Superior Accuracy. Control Your Process Anytime SLB615D POWERCELL. Know What s Ahead. Superior Accuracy

SWB505 MultiMount. SWB605 PowerMount. Right the First Time Safe, Accurate, Service Friendly. Right the First Time

Thermocouple For additional thermowell Model TC10-B

Load Cell A special beam load cell has been developed by METTLER TOLEDO to meet hygienic criteria. Self draining and a mirror polish make it unique.

Thermocouple Without thermowell Model TC10-H

Cable thermocouple Model TC40

Product specification

Product specification

Control Buttons / Switches for Panel Mounting Series 8003

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Load Cells SIWAREX WL230 BB-S SA

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Load Cells Bending beam load cells SIWAREX WL230 BB-S SA

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Position Switches Series 8074/2

Weighing Technology for Industry

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Terminal Boxes Series 8125

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Plug and Socket Devices SolConeX 16 A Series 8570

Measuring insert for resistance thermometer Model TR10-A

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Position Switches Series 8060/2

Leading the way in hazardous areas Features EATON

Terminal Boxes in Stainless Steel SLS**.T

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Tubeskin thermocouple assembly Model TC59-V

Tubular Light Fitting with LED Series 6036

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Product specification

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Assembly. Trunk IN + - S U, I U, I. Spur 1

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Ex m Solenoid Operator Type 0519

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Position Switches Series 8070/2

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Tubeskin thermocouple assembly Model TC59-V

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Linear fluorescent luminaire LED V-CG-S

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Tubeskin thermocouple assembly Model TC59-W

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Compact temperature switch Model TCS

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Compact Sheet-Steel Light Fittings Series 6114/1

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

ATEX/IECEx RTD temperature probe

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Floodlight Series 6121

Type 2REX-A. Oil & Gas / Heavy Industry

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

HI LPRC03 Advantage Hermetic Rocker Load Points

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Mini pressure switch Stainless steel switch enclosure Model PXS

Compact Sheet-steel Emergency Light Fitting Series 6118/1

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Mini temperature switch Stainless steel switch enclosure Model TXS

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

ExBin-P Pressure switches 5 Pa Pa

Spring loaded resistance thermometer

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Compact differential pressure switch Models DC, DCC

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

HTSB system System overview

Transcription:

HLC A1 HLC B1 HLC F1 Load cells Special features - Hermetically encapsulated (IP68) - Maximum capacities: 110 kg... 10 t - Rust resistant materials - Low height of construction - Meets EMC requirements as per EN 45501:2015 - Legal for trade per OIML R60 to 6000 divisions - Explosion proof versions per ATEX and IECEx, FM and EAEU Data sheet Cable assignment (six wire configuration) (gray) (black) Sensing element (-) Excitation (-) (white) Signal (+) (blue) (green) (red) (stranded wire) Excitation (+) Sensing element (+) Signal (-) Cable shield connected to enclosure ground

Dimensions (in mm; 1 mm = 0.03937 inches) K (cable length) J J HLC... B C D H G F E A cable: Ø 5.4 mm HLC A1... (220 kg; 550 kg; 1.1 t; 1.76 t; 2.2 t; 4.4 t) HLC B1... (110 kg; 220 kg; 550 kg; 1.1 t; 1.76 t; 2.2 t; 4.4 t; 10 t) M Holes only for maximum capacities 1.76 t L M HLC A1... HLC B1... N Mounting accessories for HLC B1...: see pages 4 and 5 HLC F1... (220 kg; 550 kg; 1.1 t; 1.76 t) 90 22.2 16 HLC F1... 7.7 4.8 3 17.2 Integrated overload stop Mounting accessories for HLC F1...: see page 5 Maximum capacity A B C D E F G H J K L M N 110 kg; 220 kg; 550 kg; 1.1 t 133.4 30.2 30.7 57.7 15.4 76.2 25.4 1.7 13 3 m 20.6 M12 14.2 1.76 t 133.4 30.2 30.7 51.7 15.4 76.2 25.4 1.7 13 3 m 20.6 M12 14.2 2.2 t 1) 171.5 36.5 36.8 76.2 19.1 95.3 38.1 2.5 20.5 6 m 30.2 M20 17.0 4.4 t 1) 171.5 42.9 42.9 76.2 19.1 95.3 38.1 2.5 20.5 6 m 30.2 M20 20.1 10 t 2) 245.1 72.9 60 119.9 30.2 134.9 1) Maximum capacities 2.2 t and 4.4 t only for HLC A1... + HLC B1... 2) Maximum capacity 10 t only for HLC B1 D1... 50 0.05 11.2 27 6 m 51 +0.2 32 20 Mounting accessories (to be ordered separately) According to the mounting conditions, HBM presents different, tested load applications for load cell types HLC B1... and HLC F1... (see pages 4 and 5), to minimize the effects of load application errors. HBM 2

Specifications Type HLC A1... Maximum capacity (E max ) (Load application = tapped through hole) Type HLC B1... Maximum capacity (E max ) (load application = sinking + tapped hole) 3) Type HLC F1... Maximum capacity (E max ) (Load application = blind hole + integrated overload stop) Accuracy class per OIML R60 Number of load cell verification intervals (n LC ) Minimum load cell verification interval (v min ) D1 1000 % of E max 0.0285 HLC A1 D1 /... + HLC A1 C3 /... 220 kg; 550 kg; 1.1 t; 1.76 t; 2.2 t; 4.4 t HLC B1 D1 /... 110 kg; 220 kg; 550 kg; 1.1 t; 1.76 t; 2.2 t; 4.4 t; 10 t HLC B1 C3 /... 110 kg; 220 kg; 550 kg; 1.1 t; 1.76 t; 2.2 t; 4.4 t HLC B1 C4 /... + HLC B1 C6 /... 220 kg; 550 kg; 1.1 t HLC F1 D1 /... + HLC F1 C3 /... 220 kg; 550 kg; 1.1 t; 1.76 t C3 3000 C4 5) 4000 0.0100 (220 kg; 1.76 t; 2.2 t; 4.4 t) 0.0090 (110 kg, 550 kg + 1.1 t) Nominal (rated) sensitivity (C N ) mv/v 1.94 (10 t = 2.00 mv/v) Sensitivity tolerance % 0.5 0.1 Temperature coefficient of zero signal (TC 0 ) % of C n / 10 K 0.0400 0.0140 (220 kg; 1.76 t; 2.2 t; 4.4 t) 0.0126 (110 kg, 550 kg + 1.1 t) Temperature coefficient of sensitivity (TC S ) 4) 0.0420 0.0140 0.0105 0.0070 Relative reversibility error (d hy ) 4) 0.0500 0.0166 0.0125 0.0083 Non linearity (d lin ) 4) 0.0500 0.0170 0.0166 % of C Creep upon loading (d n cr ) over 30 min. 0.0500 0.0166 0.0166 0.0122 Minimum dead load output return (MDLOR) 0.0500 0.0166 0.0125 0.0083 Input resistance (R LC ) 350... 480 Ω Output resistance (R 0 ) 350 2 350 0.12 Reference voltage (U ref ) 5 Nominal (rated) supply voltage range (B U ) V 0.5... 15 ( Ex versions max. 12 V!!! ) 5... 10 Insulation resistance (R is ) GΩ > 5 Nominal (rated) ambient temperature range (B T ) -10... +40 Operating temperature range (B tu ) C -30... +70 Storage temperature range (B tl ) -50... +85 Limit load (E L ) 150 Limit lateral loading (E lq ) 100 % Breaking load (E d ) of E 300 max Relative perm. vibrational stress (F srel ) (oscillation width per DIN 50100) 70 Nominal (rated) displacement at E max (s nom ), approx. mm 0.5 (1.76 t = 1.4 mm) Weight (G), approx. kg 0.9 (110 kg... 1.76 t); 1.6 (2.2 t); 2.2 (4.4 t); 6.2 (10 t) Degree of protection per EN 60 529 (IEC 529) IP68 Material: Measuring body Cable entry Cable sheath stainless steel 6) stainless steel 6) / seal: Viton PVC 1) Maximum capacity 10 t: Load application = sinking + tapped hole 2) The values for non linearity (d lin ), relative reversibility error (d hy ) and temperature coefficient of sensitivity (TC S ) are recommended values. The sum of these values is within the cumulated error limit laid down by OIML R60. 3) Accuracy classes C4 and C6 only for HLC B1... / 220 kg; 550 kg; 1.1 t 4) As per EN 10088 1 C6 5) 6000 Mounting accessories (to be ordered separately) According to the mounting conditions, HBM presents different, tested load applications for load cell types HLC B1... and HLC F1... (see pages 4 and 5), to minimize the effects of load application errors. 3 HBM

Accessories for HLC B... (to be ordered separately; Dimensions (in mm; 1 mm = 0.03937 inches)) HLCB/PCX/1.76 t - Oscillating loading foot (stainless steel) for HLC B / 110 kg... 1.76 t, suitable up to accuracy class C6: HLCB/ZFP/1.76 T - Oscillating loading foot (stainless steel) for HLC B / 110 kg... 1.76 t: 59.5... 65.5 * 54.5... 60.5 * 2.3 Ø50 Ø60 13 a/f 17 a/f Steel 10 Rubber plate, can be removed 65.5-72* * Height adjustment 39-45.5* 50 60 Steel Rubber Loading foot secured in load cell with accompanying bracket HLCB/ZFP/4.4 T - Oscillating loading foot (stainless steel) for HLC B / 2.2 t + 4.4 t: HLCB/ZAK/1.76T - Oscillating loading foot, heightadjustable (stainless steel) for HLC B 1.76 t 85.5-93 * 1) 89-96.5 * 2) 47.5-55 * 1) 51-58.5 * 2) 80 90 Steel Rubber * Height adjustment, ( 1) = Maximum capacity 2.2t / 2) = Maximum capacity 4.4t) 63.2-68.2 16 80 Loading foot secured in load cell with accompanying bracket 19 across flats HLCB/...T/ZEL - Rubber metal bearing (galvanized; HLCB/1.76T/ZELR made from rust resistant material) for HLC B R X T (not for 110 kg) e Z B ZEL a Y L C Maximum permissible lateral displacement (when loaded at maximum capacity): HLCB/1.76T/ZEL: 4.5 mm HLCB/4.4T/ZEL: 8 mm HLCB/10T/ZEL: 9.5 mm Type Maximum capacity B C -0.1 L R T X Y Z a e HLCB/1.76T/ZEL HLCB/1.76T/ZELR 220 kg... 1.76 t 58.8 20 118 100 9 120 60 10 92 80 HLCB/4.4T/ZEL 2.2 t 71.2 30 152.4 125 11 150 100 10 113 100 HLCB/4.4T/ZEL 4.4 t 71.2 30 152.4 125 11 150 100 10 116 100 HLCB/10T/ZEL 10 t 85 50.8 214.9 175 13 200 100 12 167 150 HBM 4

Accessories for HLC B... + HLC F... (to be ordered separately; Dimensions (in mm; 1 mm = 0.03937 inches)) HLCB/ZDP/1.76 T Easy top - Rubber metal bearing for HLC B / 220 kg... 1.76 t (Load application: stainless steel, welding plate: galvanized) A* 12 80 60 max. 0.8 mm HLCB/ZDP/4.4 T Easy top - Rubber metal bearing for HLC B / 2.2 t + 4.4 t 72 ±0.5 (Load application: stainless steel, welding plate: galvanized) max. 0.8 mm 100 76 12 Height adjustment * Mounting optional B* (= condition at the time of delivery) 19 across flats Easy top secured in load cell with accompanying bracket Welding plate (schematic top view) ZPU/1.76T: 4x M8 ZPU/2.2T + 4.4T: 4x M10 1) = maximum capacity 2.2 t 2) = maximum capacity 4.4 t 79-87 Height adjustment HLC/ZPU/...T - Mounting base / mounting kit (galvanized) for HLC B Tightening torque M A : see table Load application via: HLCB/...t/ZEL HLCB/ZDP/...t View from below G = A C D = N P HLC/ZPU/...T E F B Type Max. capacity Breaking load A B C D E F G N P M A HLC/ZPU/1.76 T 110 kg... 1.76 t 3.52 t 60.5 168 100 70 16 136 13.5 20 10 130 N m HLC/ZPU/2.2 T 2.2 t 4.4 t 81.5 212 120 84 18 175 14 25 20 400 N m HLC/ZPU/4.4 T 4.4 t 8.8 t 88 212 120 84 18 175 14 25 20 400 N m HLCF/ZKP/1.76T - Oscillating loading foot, height adjustable; (stainless steel) for HLC F 1.76 t 56... 61 HLC F 16 Loading foot secured in load cell with accompanying bracket 19 across flats 80 5 HBM

HLC load cells, optional versions Order no. K HLC Code Option 1: Design A HLCA [not with Option 3 = 110 / 10] B HLCB F HLCF [only with Option 3 = 220 / 550 / 1100 / 1760] Code Option 2: Accuracy class D1 D1 (OIML) C3 C3 (OIML) [not with Option 3 = 10] C4 C4 (OIML) [only with Option 1 = B + Option 3 = 20 / 550 / 1100 + Option 5 = S3] C6 C6 (OIML) [only with Option 1 = B + Option 3 = 20 / 550 / 1100 + Option 5 = S3] Code Option 3: Maximum capacity 110 110 kg [only with Option 1 = B + Option 4 = N/(Al2/21)] 220 220 kg 550 550 kg 1100 1,1 t 1760 1,76 t 2200 2,2 t [only with Option 1 = A / B] 4400 4,4 t [only with Option 1 = A / B] 10 10 t [only with Option 1 = B] Code Option 4: Ex protection N No Ex protection AI1/21 IECEx-ATEX zone 1/21 and FM [not with Option 3 = 110] AI2/21 IECEx-ATEX zone 2/21 R1/21 EAEU zone 1/21 R2/21 EAEU zone 2/21 Code Option 5: Cable length S3 3m (standard) [only with Option 3 = 110/220/550/1100/1760] S6 6m (standard) [only with Option 3 = 2200/4400] 6 6m [only with Option 2 = D1/C3+Option 3= 110/220/550/1100/1760] 12 12m [only with Option 2 = D1/C3] Code Option 6: Other N None K-HLC - - - - - - N HBM 6

Options Ex protection versions per IECEx, ATEX and FM AI1/21 IECEx+ATEX zone 1/21 + FM intrinsically safe, II 2G Ex ia IIC T6/T4 Gb, II 2D Ex ia IIIC T125 C Db* AI2/21** IECEx+ATEX zone 2/21 not intrinsically safe, II 3G Ex na IIC T6/T4 Gc, II 2D Ex tb IIIC T125 C Db* * with EU type examination certificate (BVS13ATEX E 108 X) and IECEx Certificate of Conformity (IECEx BVS 13.0109 X) ** IECEx zone 2/21 includes option ATEX2/22 and also offers the additional customer benefit of usage with conductive dust as well. Ex protection versions per EAC (Eurasian economic union with the member states: Russia, Belarus, Armenia, Kazakhstan, Kyrgyzstan) R1/21 EAEU zone 1/21 TR ZU 012/2011 Ex certificate, 1 Ex ia IIC T6/T4 Gb X / Ex ia IIIC T125 C Db X*** R2/21 EAEU zone 2/21 TR ZU 012/2011 Ex certificate, 2 Ex ia IIC T6/T4 Gc X / Ex tb IIIC T125 C Db X*** *** with certificate СЕРТИФИКАТ СООТВЕТСТВИЯ ТС RU C-DE.ГБ08.В.01138 7 HBM

Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. measure HBM and predict with confidence 8 Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 64293 Darmstadt Germany Tel. +49 6151 803 0 Fax +49 6151 803 9100 Email: info@hbm.com www.hbm.com