3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

Similar documents
QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

3M Cold Shrink Splice Kit QS-III 5536A

Branch Splice QS-2001B

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

3M Mechanical Shearbolt Connectors, QCI Series

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber Termination

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

3M Cold Shrink Splice Kits, QS T Series

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

Cold Shrink Silicone Rubber Termination Kit QT-III 7620-S, 7690-S and 7680-S Series kv

Cold Shrink QS T Trifurcating Transition Splice Kit

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M Cold Shrink QT-lll Silicone Rubber Indoor Tubular Termination Kits With High-K Stress Relief

High Voltage Joints and Terminations up to 72,5 kv 145 kv

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

Cable Ties. Data Sheet

QT-III Cold Shrink Silicone Rubber

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

3M Cold Shrink QT-III Silicone Rubber Skirted and Inverted Skirted Termination Kits, 7640-S, 7650-S and 7660-S Series 5, 8, 15, 25/28 and 35 kv

Data Sheet July For RoHS information, please visit

3M Products for Electrical Networks Wind Farm Capabilities. Leading Edge. Electrical Solutions for. Wind Farms

Terminations. 3M Cold Shrink Terminations FAX TERMINATIONS. Glossary of Terminations Terms 263 Cable Types for Terminating 264 3M

3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

3M Ladder Kit 3M710/MS 2 -TMK-LK

Loadbreak Apparatus Connectors

Instructions. Quick Term II 2047MT 74. Quick Term II. Silicone Rubber Termination

3M Electrical Tapes Product Selection Guide. Insulate & Protect. with Quality Tapes. Preliminary

3M Locator Plate

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)


Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

3 TM Cold Applied Barrier Boot System

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

3M Locator Plate

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

4 AWG to 2000 kcmil at 15 kv, 2 AWG to 1750 kcmil at 25 kv and 1 AWG to 1500 kcmil at 34.5 kv. Stress Control

3M Connector System 0.050" x 0.100" Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810

3M Pleated Foil I/O Cable Assemblies MDR Series

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

3M CP2 Press-Fit Headers and Sockets, 2 mm

INSTALLATION PRODUCTION TESTS

3M Mini D Ribbon (MDR) Cable Assembly.050 High Speed Video Data Transmission System, 50 Position 14X50-SZWB-XXX-0NC

3M Three-Wall and Four-Wall Headers. Series 3XXX

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet

Contents. Design Test Results for Specimen Design Test Results for Specimen Voltage Impulse Oscillograms...9

Medium Voltage Catalog

3M Closure System 2-Type Cover (505)

Medium Voltage. Joints & Terminations

MEDIUM VOLTAGE TERMINATIONS

Complete care. kind of cable. for any. Cable Accessory Products FAX CABLE ACCESSORY PRODUCTS

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

3M Cable Ties Product Guide. Made in USA. & Plenum Rated

25kV 200A Loadbreak Bushing Insert and Elbow Design Test Report. Report Number:

3M Textool Test and Burn-In Sockets for 1.0 mm Area Array Packages Including Ball Grid Array and Land Grid Array

25 kv class fused loadbreak elbow connector

Product Number

3 Reenterable Encapsulated PST Dome Closure

600 A 35 kv class separable splices

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions

710 Splicing Rig. Instructions. January E

600 A 25 kv class BT-TAP deadbreak connector

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C

C Power Connection Kit

MEDIUM VOLTAGE

3M No Polish LC/APC Connector SM, Angle Splice, 250/900 µm 8830-APC/AS

3M No Polish LC Connector SM and MM, Flat Splice, 250/900 µm

600 A 35 kv class BT-TAP deadbreak connector

SLiC Aerial Closures

TABLE OF CONTENTS Page

Transcription:

3M Cold Shrink QS-III Inline Splice Kits 15 kv Data Sheet June 2014! CAUTION Working around energized high-voltage systems may cause serious injury or death. Installation should be performed by personnel familiar with good safety practice in handling high-voltage electrical equipment. De-energize and ground all electrical systems before installing product. Product Description The 3M Cold Shrink QS-III Splice Kits are 15 kvclass inline splices for joining tape, longitudinally corrugated (LC), wire and UniShield shielded power cables. They are a cold shrink design sized to fit Type MV-90 or Type MV-105 cables with copper or aluminum conductor sizes ranging from 2 AWG to 1000 kcmil (35 to 500 mm 2 ). The cold shrink splice body is a one-piece molded design made of specially formulated silicone rubbers, while the cold shrink jacketing is made of EPDM rubber for physical protection. Each splice manufactured is factory tested to provide reliability. The splices can be used with standard copper (Cu) or aluminum (Al/Cu) inline compression (crimp type) connectors or specified shearbolt connectors, and can be used for size transitions within the listed kit size range. They are designed to exceed minimum industry test standards, and have a BIL rating of 150 kv (equal to a 25 kv voltage class). The Cold Shrink QS-III Splice Kits meet or exceed the 15 kv Voltage Class rating requirements of ANSI/IEEE Std. 404. 78-8125-9892-4 Rev D 1 of 9 3

Kit Contents for 5513A, 5514A, 5515A and 5516A 1 3M Cold Shrink Silicone Rubber Splice Body 1 3M Cold Shrink Adapter Tube (2 adapters in the 5513A Kit) 1 3M Cold Shrink Jacketing Tube 2 3M Red Compound Tubes P55/R 6 Scotch Mastic Sealing Strips 2230 2 Scotch Rubber Mastic Tape 2228 Rolls 1 3M Cable Cleaning Pad CC-3 1 Cable Preparation Template 1 Shielding Sleeve 1 Ground Strap 5 Constant Force Spring Ground Connectors 2 Copper Tape Strips 1 Instruction Booklet Splice Features Cold Shrink Design for quick and easy installation; excellent for cable size transitions Complete Kit includes the required products to make one splice Silicone Rubber Construction for good high and low temperature performance Production Tested partial discharge and A.C. withstand tests to provide reliability Computer Aided Design for compact size and optimal distribution of electrical field Special Electrode Design minimizes electrical stress at critical cable/splice interface High Ampacity Shield faults current rated for 15,000 Amps for 15 cycles, neutral current rated for 350 Amps. Applications For splicing 15 kv shielded power cables: For inline splicing For feeder and distribution circuits For tape, longitudinally corrugated (LC), wire and UniShield shielded cables For transitions from shielded to neutral power cables For copper or aluminum conductors For use with standard inline crimp connectors For use with specified 3M Shearbolt Connectors QCI Series For size transition splicing For direct burial installations For submerged locations Physical and Electrical Properties The 3M Cold Shrink QS-III Splice Kits can be used on cables with a rated operating temperature up to 105 C, and an emergency overload rating of 140 C. A splice constructed from this kit is rated for 15 kv and meets or exceeds the requirements of IEEE Std. 404. The current rating of the splice meets or exceeds the current rating for the cables on which it is installed. BIL rating is 150 kv, which exceeds the normal 110 kv BIL rating for a 15 kv voltage class. 2 of 9 78-8125-9892-4 Rev D

Splice Selection Table Kit Number Cable Insulation O.D. Range Conductor Size Range AWG or kcmil (mm 2 ) 5513A 0.64-1.01 (16,3-25,7) 2-4/0 (35-95) 5514A 0.84-1.38 (21,3-35,1) 4/0-500 (95-240) 5515A 1.04-1.70 (26,4-43,2) 350-750 (185-325) 5516A 1.08-1.70 (27,4-43,2) 500-1000 (240-500) Table 1 Connector Dimensional Requirements Table Kit Number Minimum O.D. Maximum O.D. Aluminum (AI/Cu) Compression Maximum Length Copper (Cu) Compression 3M Shearbolt Connector QCI Series 5513A 0.40 (10,2) 1.06 (26,9) 4.50 (114) 5.00 (127) 4.41 (112) 5514A 0.69 (17,5) 1.38 (35,1) 5.00 (127) 5.75 (146) 5.75 (146) 5515A 0.80 (20,3) 1.84 (46,7) 6.75 (171) 7.50 (191) 6.93 (176) 5516A 0.80 (20,3) 1.84 (46,7) 6.75 (171) 7.50 (191) 7.83 (199) Connector O.D. Range Requiring adapters 0.40-0.64 (10,2-16,3) 0.69-0.84 (17,5-21,3) 0.80-1.04 (20,3-26,4) 0.80-1.08 (20,3-27,4) Table 2 Typical Dimensions (Installed Splice) Kit Number Typical Length (L) Typical Diameter (D) 5513A 28 (711) 2.25 (57) 5514A 29 (736) 2.50 (64) 5515A 32 (813) 3.00 (76) 5516A 32 (813) 3.00 (76) Table 3 3 of 9 78-8125-9892-4 Rev D

Typical Physical and Electrical Properties Silicone Rubber (Splice Body Insulation) Physical Properties Test Method Hardness Shore A (ASTM D 2240) 50 Elongation (%) (ASTM D 412) 610 Tensile Strength (psi) (ASTM D 412) 1090 (7,5 N/mm 2 ) Modulus @ 100% (psi) (ASTM D 412) 340 (2,3 N/mm 2 ) Permanent Set % (100%, 100 C, 22 hrs) (3M TM 86) 5 Thermal Conductivity (W/m K) (ASTM D 518) 0.24 Electrical Properties Dielectric Strength (V/mil) (ASTM D 149) 370 (14,6 kv/mm) Dielectric Strength, Wet (V/mil) (ASTM D 149) 340 (13,4 kv/mm) Dielectric Constant (ASTM D 150) 3.3 Dielectric Loss (ASTM D 150) 0.005 Volume Resistivity (Ohm-cm) (3M TM 80) 6x10 14 Typical Value* Silicone Rubber (Splice Body Inner Electrode) Physical Properties Test Method Hardness Shore A (ASTM D 2240) 43 Elongation (%) (ASTM D 412) 510 Tensile Strength (psi) (ASTM D 412) 880 (6,1 N/mm 2 ) Modulus @ 100% (psi) (ASTM D 412) 200 (1,4 N/mm 2 ) Permanent Set % (100%, 100 C, 22 hrs) (3M TM 86) 4 Typical Value* Electrical Properties Volume Resistivity (Ohm-cm) (3M TM 80) 50 Silicone Rubber (Splice Body Semi-Con Shell) Physical Properties Test Method Hardness Shore A (ASTM D 2240) 43 Elongation (%) (ASTM D 412) 520 Tensile Strength (psi) (ASTM D 412) 890 (6,1 N/mm 2 ) Modulus @ 100% (psi) (ASTM D 412) 230 (1,6 N/mm 2 ) Permanent Set % (100%, 100 C, 22 hrs) (3M TM 86) 5 Typical Value* Electrical Properties Volume Resistivity (Ohm-cm) (3M TM 80) 150 *All values are averages, based on several determinations and are not intended for specification purpose. 4 of 9 78-8125-9892-4 Rev D

Ethylene Propylene Rubber (Jacketing Tubes) Physical Properties Test Method Color Black Hardness Shore A (ASTM D 2240) 48 Elongation (%) (ASTM D 412) 635 Tensile Strength (psi) (ASTM D 412) 1680 (11,6 MPa) Modulus @ 100% (psi) (ASTM D 412) 170 (1,17 MPa) Fungus Resistance, 28 days (ASTM G 21) No Growth Permanent Set % (250%, Strain) 8.8 (5 min. recovery, @ 40 F, 4.4 C) 14.6 Typical Value* Electrical Properties Dielectric Strength, Orig. (V/mil) (ASTM D 149) 490 (19,1 kv/mm) Dielectric Strength, Wet (V/mil) (ASTM D 149) 465 (18,1 kv/mm) Dielectric Constant, Orig. (ASTM D 150) 5.0 Dielectric Constant, Wet (ASTM D 150) 5.6 *All values are averages, based on several determinations and are not intended for specification purpose. Product (Open Specification) The tape, longitudinally corrugated (LC), wire and UniShield shielded power cable splice shall meet the requirements of ANSI/IEEE Std. 404 for a 15 kv rating, and must be rated by the manufacturer for use on 15 kv class cable systems. It must be rated for continuous operation at 105 C, with an emergency overload temperature rating of 140 C. The splice shall be capable of splicing cables with copper or aluminum conductors sized from 2 to 4/0 AWG (35 to 95 mm 2 ), 4/0 AWG to 500 kcmil (95 to 240 mm 2 ), 350 to 750 kcmil (185 to 325 mm 2 ) and 500 to 1000 kcmil (240 to 500 mm 2 ) or accommodate a conductor size transition within those size ranges. The splice shall be of a cold shrink design which does not require any additional heat source for installation. The cold shrink splice body must be of a molded design made of silicone rubber. The splice jacketing shall be of a cold shrink tubing made of EPDM rubber. The color of the splice body and outer jacket shall be black. Engineering/ Architectural (Closed Specification) Splicing of all 15 kv rated cables, tape, longitudinally corrugated (LC), wire and UniShield shielded power cables, sized from 2 AWG to 1000 kcmil (35 to 500 mm 2 ) copper or aluminum, shall be performed in accordance with the instructions provided with the 3M Cold Shrink QS-III Splice Kits. Shielding Short Circuit Testing The QS-III shielding system is rated for 15 ka for 15 cycles. The shielding system was submitted to an independent test laboratory for short circuit testing. High ampacity performance was verified by applying the following series: 10 ka-rms for 10 cycles, 12 ka-rms for 12 cycles and 15 ka-rms for 15 cycles. The QS-III Shielding System is rated for 350 Amps of neutral current. The shielding system was tested in a loop similar to that which is used in the ANSI C119.4 Connector Test Method, by measuring temperature and resistance. Ampacity performance was verified by applying current in 3-hour on/3- hour off cycles at levels up to and exceeding the 350 Amp rated current. The shielding system consists of a tin-plated braided copper sleeve which serves as the splice metallic shield and ground jumper, connected to the cable metallic shields with solderless constant force springs. 5 of 9 78-8125-9892-4 Rev D

Performance Test IEEE Std. 404 15 kv Voltage Rating Design Test and Sequence Test Requirement Minimum partial discharge (corona) level 13 kv-rms @ < 3pC Alternating-current 1 minute withstand 35 kv rms Direct-current 15 minute withstand 70 kv dc Impulse withstand (BIL) at 25 C (77 F)* ±110 kv crest (150 kv)* Impulse withstand (BIL) at 140 C (284 F)* ±110 kv crest (150 kv)* Minimum partial discharge (corona) level 13 kv rms @ < 3 pc Cyclic aging (in air and water) 26 kv rms Minimum partial discharge (corona) level 13 kv rms @ < 3 pc High voltage time: 5 hr. alternating-current withstand 31 kv rms 5 min. alternating-current withstand 39 kv rms Short-time current (ICEA P 32 382 and ANSI/IEEE C37.09) 250 C conductor temp with no damage Alternating-current 1 minute withstand 35 kv rms Shielding IEEE Std. 592 Connector thermal and mechanical ANSI C119.4 Production Test Test Requirement Production splices tested 100% Minimum partial discharge (corona) level 13 kv rms @ < 3 pc Alternating-current 1 minute withstand 35 kv rms *Notes: (1) BIL rating for 5513A (5415A splice body), 5514A (5416A splice body), 5515A (5417A splice body) and 5516A (5418A splice body) QS III is upgraded to ±150 kv crest. (2) Impulse test wave is 1.2 x 50 µsec. (ANSI/IEEE Std. 4). Operating Temperature Reference: AEIC CS5 and AEIC CS6: Normal Operation: 105 C Emergency Operation: 140 C Installation Techniques for 5513A, 5514A, 5515A, and 5516A Kits Detailed instructions for installing the 3M Cold Shrink QS-III Splice Kits 5513A, 5514A, 5515A, and 5516A are included with each kit. A Cable Preparation Template is provided: 1. Prepare cable according to standard procedure. 2. Slide cold shrink jacketing tube and cold shrink splice body onto prepared cables. 3. Position expanded shield sleeve onto one cable 4. Install connector. Dimensional requirements table provided. 5. Apply a tape marker on one cable. 6. Apply 3M Red Compound P55/R on cable insulation and fill in edge of cable semi con. DO NOT use silicone grease. 7. Install splice over connector area, aligning end with tape marker, and removing core by pulling and unwinding counterclockwise. 8. Install shield sleeve, centered over splice body, and attach to cable metallic shields with constant force springs. 9. Connect ground strap if circuit grounding is required at this location. Apply mastic sealing strips to seal ground strap at end of cable jacket. 10. Apply rubber mastic tape around the end of both cable jackets. 11. Install cold shrink jacketing tube over splice. 12. Connect ground strap to ground if splice is to be grounded. 13. If located in direct sunlight, overwrap splice with vinyl tape.. 6 of 9 78-8125-9892-4 Rev D

Maintenance Components of the 3M Cold Shrink QS-III Splice Kits 5513A, 5514A, 5515A and 5516 are stable under normal storage conditions. Normal stock rotation procedures are recommended. As provided, in the expanded state, the QS-III splice kits have an on-shelf storage life of three years from the date of manufacture. The installed splices can be field tested using standard field cable testing procedures (reference ANSI/IEEE Std. 400, Guide for Making High Direct Voltage Tests on Power Cable Systems in the Field ). Connectors for QS-III Splices The QS-III Cold Shrink Splice kits are designed to be used with 3M Scotchlok Connectors 10000, 11000, and 20000 Series, 3M Connectors CI-Series, or other UL listed inline compression connectors that fit within the dimension limits listed in the 3M Connector Dimensional Requirements Table 2. In addition, the following transition connectors may be used: Conductor Kit Number Sizes (AWG or kcmil) 3M Compression Connectors 3M Shearbolt Connectors QCI Series 2 to 1 CI-T2 2 to 1/0 CI-T4 5513A 2 to 2/0 1/0 to 3/0 2/0 to 3/0 2 to 4/0 1/0 to 4/0 2/0 to 4/0 3/0 to 4/0 CI-T7 QCI-2-250 5514A 5515A 5516A 4/0 to 250 4/0 to 300 4/0 to 350 2000T 4/0-350 CU/AL 250 to 350 2000T 250-350 CU/AL 300 to 350 2000T 300-350 CU/AL 350 to 500 2000T 350-500 CU/AL 350 to 500 2000T 350-500 CU/AL 350 to 600 500 to 600 350 to 750 500 to 750 500 to 750 500 to 1000 750 to 1000 QCI-4/0-600 QCI-350-750 QCI-500-1000 7 of 9 78-8125-9892-4 Rev D

Connectors for QS-III Splices The QS-III Cold Shrink Splice kits are designed to be used with 3M Scotchlok Connectors 10000, 11000, and 20000 Series, 3M Connectors CI-Series, or other UL listed inline compression connectors that fit within the dimension limits listed in the 3M Connector Dimensional Requirements Table 2. In addition, the following transition connectors may be used: Kit Number 5513A Conductor Sizes (AWG or kcmil) Homac Connectors Burndy Connectors 2 to 1 YRB25U2 2 to 1/0 SAC1/0R2 YRB25U2 MLCR 1/0-2 2 to 2/0 SAC2/0R2 1/0 to 3/0 SAC3/0R1/0 YRB27U25 MLCR 3/0-1/0 2/0 to 3/0 YRB27U26 2 to 4/0 SAC4/0R2 1/0 to 4/0 SAC4/0R1/0 2/0 to 4/0 SAC4/0R2/0 YRB28U26 MLCR 4/0-2/0 3/0 to 4/0 Mac Products 5514A 5515A 5516A 4/0 to 250 SAC250R4/0 YRB29U28 MLC 250 + AAR 250-4/0 Adapter 4/0 to 300 SAC300R4/0 4/0 to 350 SAC350R4/0 YRB31U28 MLCR 350-4/0 250 to 350 SAC350R250 YRB31U29 MLC 350 + AAR 350-250 Adapter 300 to 350 350 to 500 MLC 500 + AAR 500-350 Adapter 350 to 500 SAC500R350 YRB34U31 MLC 500 + AAR 500-350 Adapter 350 to 600 YRB36U31 500 to 600 YRB36U34 350 to 750 SAC750R350 MLC 750 + AAR 750-350 Adapter 500 to 750 SAC750R500 YRB39U34 MLCR 750-500 500 to 750 SAC750R500 YRB39U34 MLCR 750-500 500 to 1000 MLCR 1000-750 + AAR 750-500 Adapter 750 to 1000 MLCR 1000-750 8 of 9 78-8125-9892-4 Rev D

Shelf-Life This product has a 3-year shelf life from date of manufacture when stored in a humidity controlled storage (10 C / 50 F to 27 C / 80 F and <75% relative humidity). Availability 3M Cold Shrink QS-III Splice Kits 5513A, 5514A, 5515A and 5516 are available to splice 15 kv tape, longitudinally corrugated (LC), wire and UniShield shielded power cables. The connectors can be either ordered with the kit or provided separately. Standard dimension copper (Cu) or aluminum (Al/Cu) compression (crimp type) connectors are suitable for use with these splice kits, as are 3M Shearbolt Connectors QCI Series. These kits are available from your local authorized 3M electrical distributor. 3M, Scotch and Scotchlok are trademarks of 3M Company. UniShield is a registered trademark of General Cable Technologies Corporation. Important Notice Warranty; Limited Remedy; Limited Liability All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product, which are not contained in 3M s current publications, or any contrary statements contained on your purchase order, shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. This product will be free from defects in material and manufacture at the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Electrical Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 800.245.3573 FAX: 800.245.0329 www.3m.com/electrical Please recycle 3M 2014 All rights reserved 9 of 9 78-8125-9892-4 Rev D