M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

Similar documents
M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

Technical Data Sheet Sigma Series DS Meter

SIGMA SERIES DE METER

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

Technical Data Sheet Sigma Series DG Meter

Technical Data Sheet Sigma Series DE Meter

Smart Look Series Meter

PLATINUM SERIES SWITCHBOARD METERS

Data Sheet. Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144. Analogue Meters with. Moving - Iron Movement

DIN Panel Meters Long Scale

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS

Century Style Analog Panel Meters

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter

ANSI Switchboard Meters

AC Wattmeters and VArmeters

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters

Analogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy

Standard Program Technical Description

Crompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ORDERING INFORMATION

MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES

EM DC Multi-Function DC Energy Meter

YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant

Square Shape Instrument - PK Series

Moving Coil Indicators with direct temperature sensor input

Data Sheet. Data Sheet- Shunts. 50 mv 60 mv 75 mv 100 mv 150 mv. Shunts Class 0.5, 1.0

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

Thermal Overcurrent Circuit Breaker 3120-F...

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

AF40... AF96 3-pole contactors Technical data

Thermal Overcurrent Circuit Breaker 3120-F...

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

SECTION INDEX. Whether the need is for a simple voltmeter or a complex monitoring system, look to Blue Sea Systems for a solution.

Price List Effective from :

B2, B3, B4, B5, B6 Measuring shunts

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

Wind display type WSDI-2 DATA SHEET

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Product Information. Viewline Temperature gauges. Description. Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature.

Portable Instruments. Bulletin 2000-E

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays

MODEL 422 Submersible Pump Controller

Thermal Overcurrent Circuit Breaker 3120-F...

Technical Datasheet P-30/P-31. Standard transmitter.

Basic Series Accessories Low Voltage Current Transformer Class 1

Hillstone PowerBank HPB54 Series ( 400A 700A )

240 Series DIN Panel Meters

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

CI-TI Contactors and motor starters Types CI 61 - CI 98

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

Model 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Thermal Circuit Breaker 3120-F...

Panel Meters and Accessories Digital Panel Meter

Thermal Overcurrent Circuit Breaker 3120-F...

Bourdon tube pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21PB, NS 60, 80 and 100

JUMO MIDAS S05 Pressure transmitter Type

Air damper actuators

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Duplex pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21DPB, NS 60, 80, 100 and 130

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Non-Spring Return EconoDrive Floating Actuator

Magnetic and Hydraulic-Magnetic Circuit Breaker

FLOW METER WITH FLOAT type K

Actuators for Fire Protection Dampers

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

Pretest Module 29 High Voltage Unit 1

Precision Bourdon tube pressure gauges

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Thermal-magnetic Miniature Circuit Breaker 4230-T...

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Electronic Circuit Breaker ESS20-0..

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Air damper actuators

Screw-in resistance thermometers with plug connector

K - Flow Meter with Float

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Pressure transmitter for industrial applications Type MBS 4510

Magnetic and Hydraulic-Magnetic Circuit Breaker

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

MINIATURE CIRCUIT BREAKER

75a. Hoyt VU Meters. Industry Standard for Volume Level Measurements Sizes from 1.5" to 4.5" Choice of Styles & Mounting Made in U.S.A.

INVERTER/CHARGERS Off-Grid Power Solutions

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

RP-4000 Reserve Power Control

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

KINAX SR 709 Transmitter for Position Feedback

Bimetal Thermometers Model 54, Heavy Duty Series

Thermal Overcurrent Circuit Breaker 3120-F...

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

Electronic pressure switch with integrated analogue output

INSTALLATION INSTRUCTIONS

Low and High Voltage Power Supplies

Transcription:

Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial

Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide continuous surveillance of Amps and Volts. If used with transducers they monitor frequency, Watts or Vars, power factor or any other physical variable. One or two outputs with change over contacts are incorporated. Options are LOW or HIGH setpoints in five different models: Min one, one setpoint, LOW alarm Max one, one setpoint, HIGH alarm Min/Min two s, two setpoints, LOW alarm plus prewarning setpoint Min/Max two s, two setpoints, LOW and HIGH alarm Max/Max two s, two setpoints, HIGH alarm plus prewarning setpoint As standard, the s provide closed contacts (closed circuit principle): they de energize when the monitored signal value moves outside the chosen setpoint limits shown by adjustable red pointers or in case of power failure. As an option, the controllers can be supplied with s having open contacts (open circuit principle). Setpoint and zero adjustment are accessible from the front. Functional Principle RW 96 Moving iron movement with shell type system, pivot suspension. Spring loaded jewel bearings and silicon oil damping for vibration and shock resistance. RP 96 Self shielding moving coil movement with core type magnetic system, pivot suspension. Twin spring loaded shock absorbing jewel bearings. Integrated comparators optically scan the selected setpoint limits and drive the potential free outputs. Mechanical Data case details square case suitable to be mounted in switch boards or mosaic grid panels, stackable material of case pressed steel material of window glass colour of bezel black (similar to RAL 9005) of use vertical 5 panel fixing screw clamps panel thickness 1... 15 mm mounting stackable next to each other terminals voltmeters and hexagon studs, M5 screws and ammeters wire clamps C10 contacts and barrier type screw clamp (up to 2.5 mm 2 ) power supply protective wire connector blade 6.3 x 0.8 dimensions bezel 96 mm case 90 mm depth 78 mm without dial illumination 106 mm with dial illumination panel cutout 92 +0.8 mm weight approx. 0.5 kg Electrical Data measuring unit RW 96 AC voltage or current RP 96 DC voltage or current overload capacity (according to DIN EN 60 051-1) continuously 1.2 times rated voltage / current 5 s max. voltmeters 2 times rated voltage ammeters 10 times rated current measurement category CAT III operating voltage 300 V enclosure code IP 40 case front side IP 00 for terminals without protection against accidental contact IP 20 for terminals protected against accidental contact Measuring Ranges For mains use RW 96 AC current 1 ) RW 96 AC voltage 40 ma 40 V 60 ma 60 V 100 ma 100 V 150 ma 150 V 250 ma 250 V 400 ma 400 V 600 ma 500 V 1 A 1.5 A 2.5 A 4 A 5 A 6 A 10 A 15 A RW 96 for use on RW 96 for use on current transformer 1 ) voltage transformer N/1 A 100 V sec. N/5 A 110 V sec. Please state transformer ratio when ordering. power consumption RW 96 voltmeters approx. 1.5... 3 VA ammeters approx. 0.5... 1 VA for other ratings refer to Options 1 ) full scale value = 2 times rated current (overload scaling) 2 ) full scale value = 1.2 times rated voltage (overload scaling) 3 ) all resistance values are limited to a tolerance of 20%

DC current internal resistance 3 ) / DC voltage >5 V RP 96 voltage drop approx. RP 96 sensitivity 3 ) 100 A 5000 6 V 1 k/v 150 A 3600 10 V 1 k/v 250 A 2200 15 V 1 k/v 400 A 1300 25 V 1 k/v 600 A 260 40 V 1 k/v 1 ma 60 mv 60 V 1 k/v 1.5 ma 60 mv 100 V 1 k/v 2.5 ma 60 mv 150 V 1 k/v 4 ma 60 mv 250 V 1 k/v 5 ma 60 mv 6 ma 60 mv 10 ma 60 mv 15 ma 60 mv 20 ma 60 mv 25 ma 60 mv 40 ma 60 mv 60 ma 60 mv 100 ma 60 mv 150 ma 60 mv 250 ma 60 mv 400 ma 60 mv 600 ma 60 mv 1 A 60 mv also with rectifier incorporated for use on sinusoidal AC voltage RP 96 for use with external shunt sensitivity 3 ) 60 mv 1 k/v 150 mv 1 k/v a total lead resistance of 0.05 is considered in the calibration of the for connecting leads 1 m, 2 x 0.75 mm 2 Not for mains use RP 96 DC voltage 5V sensitivity 3 ) 100 mv; 150 mv; 250 mv; 400 mv; 600 mv 1 k/v 1 V; 1.5 V; 2.5 V; 4 V 1 k/v also with rectifier incorporated for use on sinusoidal AC voltage RP 96 for use on transducer ( live zero ) 4... 20 ma mechanically suppressed zero, without zero adjustment, voltage drop approx. 60 mv Scaling pointer bar / knife edge pointer pointer deflection 0... 90 scale RW 96 initial scale compressed, starts at characteristics approx. 1 / 5 th of rated scale value RP 96 linear scale division coarse fine scale length 78 mm overload scaling ammeters 2 times rated current voltmeters for use on 1.2 times rated voltage voltage transformers for other ratings refer to Options Data Sheet M Series 140.D.101.06 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Auxiliary Supply auxiliary voltage power consumption AC 230 V (195.5... 253 V), 48... 62 Hz 3 VA max. Measuring input and auxiliary supply are electrically insulated. Accuracy at Reference Conditions accuracy class 1.5 according to DIN EN 60 051-1 reference conditions ambient temperature 23C of use nominal 1 input rated measuring value frequency RW 96 50 Hz wave form RW 96 sinusoidal, distortion factor <5% others DIN EN 60 051-1 influences ambient temperature 23C2K of use nominal 5 frequency RW 96 15... 100 Hz (voltage) 15... 400 Hz (current) stray magnetic field 0.5 mt Environmental climatic suitability operating temperature range storage temperature range relative humidity shock resistance vibration resistance climatic class 2 according to VDE/VDI 3540 sheet 2 0... +40C 25... +65C Rules and Standards 75% annual average, non condensing 15 g, 11 ms 2.5 g, 5... 55 Hz DIN 43 718 Measurement and control; front - frames and frontpanels of measurement and control equipment; principal dimensions DIN 43 802 Line scales and pointers for indicating electrical measuring instruments; general requirements DIN 16 257 Nominal s and symbols used for measuring instruments DIN EN 60 051 Direct acting indicating analogue electrical measuring instruments and their accessories 1 Part 1: Definitions and general requirements common to all parts 2 Part 2: Special requirements for ammeters and voltmeters 9 Part 9: Recommended test methods DIN EN 60 529 Enclosure codes by housings (IP - code) DIN EN 61 010-1 Safety requirements for electrical measuring, control and laboratory equipment Part 1: General requirements DIN EN 61 326-1 Electrical equipment for measurement, con - trol and laboratory use EMC requirements Part 1: General requirements (IEC 61 000-4-3 evaluation criterion B) DIN IEC 61 554 Panel mounted equipment Electrical measuring instruments Dimensions for panel mounting VDE/VDI 3540 sheet 2 reliability of measuring and control equipment (classification of climates) (non- condensing)

Setpoints control modes (closed circuit principle ) RW/P 96 Min 0 45 90pointer LOW setpoint 1 energized 0 de energized 1 setpoint with : energized with pointer above chosen setpoint limit. setpoint adjustment 0... 93 % of scale length RW/P 96 Max RW/P 96 Min/Max 0 45 90pointer LOW setpoint 1 energized 0 de energized HIGH setpoint 2 setpoints with and s: s energized with pointer above resp. below chosen setpoint limits. setpoint adjustment 7... 91 % of scale length 9... 93 % minimum span 2 % RW/P 96 Max/Max 0 45 90 pointer HIGH setpoint Max (HIGH ) Max (HIGH ) 0 45 90pointer HIGH setpoint HIGH setpoint Max (HIGH ) Max (HIGH ) 1 energized 0 de energized 1 setpoint with : energized with pointer below chosen setpoint limit. setpoint adjustment 7... 100 % of scale length RW/P 96 Min/Min 1 energized 0 de energized 2 setpoints with 2 s: s energized with pointer below chosen setpoint limits. setpoint adjustment Max (HIGH ) 7... 96 % of scale length Max (HIGH ) 11... 100 % minimum span 4 % Min (LOW ) Min (LOW ) 0 45 90pointer LOW setpoint 1 energized 0 de energized LOW setpoint Min (LOW ) Min (LOW ) 2 setpoints with 2 s: s energized with pointer above chosen setpoint limits. setpoint adjustment Min (LOW ) 0... 89 % of scale length Min (LOW ) 4... 93 % minimum span 4 % accuracy response value 1% of scale length repeatability <0,2% of scale length differential <1% of scale length output s 1 SPDT on each setpoint; maximum contact rating non inductive: contact voltage 250 V AC contact current 6 A contact output 1500 VA operations 10 5 at above load mech. operations 10 7

Options Connections Data Sheet M Series 140.D.101.06 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial measuring RP 96 to include rectifier for use range on sinusoidal AC voltages ranging from 0... 1.5 V to 0... 500 V (RG 96) special measuring deviating from standard range adjustment of internal to 1% at 23C resistance RP 96 lead resistance RP 96 calibration to >0.05 operation open circuit principle auxiliary voltage AC 115 V (97.75... 126.5 V), 48... 62 Hz, 3 VA or DC 24 V (20.4... 26.4 V), 2 VA case window non glaring glass colour of bezel gray (similar to RAL 7037) of use horizontal or to be specified 15...165 performance increased mechanical shock 30 g, 11 ms loads vibration 5 g, 5... 55 Hz climatic suitability limited use in the tropics climatic class 3 according to VDE/VDI 3540 sheet 2 with operating 10... +55C temperature range marine application non certified accessories terminal protection against accidental contact full sized rear cover or protective sleeves terminals connector blades 6.3 x 0.8 (measuring input) dial blank dial pencil marked initial and end values scale division 0... 100%, and figuring linear (RP 96), full scale values acc. to standardized series (1-1.2-1.5-2 - 2.5-3 - 4-5 - 6-7.5 and any decimal multiple of these numbers e.g. 150 m 3 /h) or deviating from standard series; special calibration from customer s non linear graph or chart; scaling of voltmeters in ohms; captions optional additional lettering to be specified e.g. generator additional figuring to be specified coloured marks red, green or blue for important scale values coloured sector red, green or blue within scale division logo on the dial none or as specified zero centre zero or off set zero dial illumination by one 6 V, 12 V or 24 V to be installed from the rear, dial translucent AC voltage AC current DC voltage DC current terminal markings setpoint s, aux. supply up to series No. 1900: Max Max Min setpoint s as of series No. 2000: Min Max Min aux. supply ~ Max Max Min Min Max Min ~ setpoint s aux. supply Relay s shown refer to auxiliary voltage applied with pointer not having passed above resp. below chosen setpoint limits (s energized, closed circuit principle).

Dimensions Ordering Information a 64 without illumination 101 with illumination type two point controller with RW moving iron movement RP moving coil movement front dimension 96 96 mm x 96 mm control function Min with setpoint Max with setpoint Min/Min with LOW & prewarning setpoint Min/Max with LOW & HIGH setpoint Max/Max with HIGH & prewarning setpoint (scaled in mm) Weigel Meßgeräte GmbH Postfach 720 154 90241 Nürnberg Phone: 0911/42347-0 Erlenstraße 14 90441 Nürnberg Fax: 0911/42347-39 Sales: Phone: 0911/ 42347-94 Internet: http://www.weigel messgeraete.de e mail: vertrieb@weigel messgeraete.de measuring ranges refer to preceding table measuring range DC current or DC voltage 1 ) RP 96 sinusoidal AC voltage (RG 96) live zero RP 96 4... 20 ma mechan. suppressed zero 1 ) sp. measuring range to be specified 2 ) adjustments RP 96 internal resistance 20% 1 ) internal resistance to 1% at 23C lead resistance >0.05 operation closed circuit principle 2 ) open circuit principle auxiliary supply 230 V ~ 1 ) 115 V ~ 24 V= window glass 1 ) non-glaring glass colour of bezel black (similar to RAL 9005) 1 ) gray (similar to RAL 7037) of use vertical 1 ) to special order 15... 165 2 ) mechanical loads shock 15 g, vibration 2.5 g 1 ) shock 30 g, vibration 5 g climatic suitability class 2, 0... +40C 1 ) class 3, 10... +55C marine application none 1 ) non-certified terminal safety none 1 ) protection full-sized rear cover protective sleeves SW10 terminals screws and wire clamps 1 ) (measuring input) connector blades 6.3 x 0.8 dial scale division and measuring range alike resp. full-scale values acc. to standardized series for use on transformer 1 ) blank dial scale division and figuring 0... 100% linear (RP 96) to standardized series 2 ) linear (RP 96) deviating from standard 2 ) calibration fr. non-linear graph or chart 2 ) scaling in ohms for voltmeters 2 ) additional lettering to be specified 2 ) additional figuring to be specified 2 ) coloured marks red, green or blue 2 ) coloured sector red, green or blue 2 ) logo WEIGEL 1 ) none OEM logo 2 ) zero left hand zero 1 ) centre or off - set zero 2 ) dial illumination none 1 ) with 1 lamp 6 V, 12 V or 24 V 1 ) Standard 2 ) Please clearly add the desired specifications. ordering example RW 96 Min/Max, measuring range 0... 1 A, scale 0... 1 / 2 ka, window non glaring glass, WEIGEL logo specifications subject to change without notice; date of issue 04/15