VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Similar documents
VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

INSTALLATION INSTRUCTIONS

Use and Care Guide.

INSTALLATION INSTRUCTIONS

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

Wireless Key Tracker. Locate Lost Keys instantly

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

WIRELESS SMART CHARGING PAD OPERATING INSTRUCTIONS PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Instruction Manual. SmarTire LF Initiator Tool. PN: Revision 1.2. Copyright 2006 SmarTire Systems Inc.

Owner's Manual. For latest instructions please go to

CAUTION: Read manual carefully for proper procedures and operation.

FLO Home TM G5 Model. Installation guide

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

BroadBand PowerShield. 20 AHr Battery. User Manual

RJH-4/6046. Wireless 3.5 Channel Mega Helicopter. (Instruction Manual)

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

User Guide. Digital Shipping Scale S150

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

Owner's Manual. For latest instructions please go to

MQ4C-24/6485 WIRELESS INDOOR/OUTDOOR QUAD-COPTER

SAVE THESE INSTRUCTIONS

Innovative Circuit Technology Ltd.

LED Recessed Troffer Retrofit Kit

TC26-B Vehicle Sensor

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

Installation and Operating Manual

Owner's Manual. For latest instructions please go to

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

Please read and understand all precautions prior to use.

User Guide. Model No.: GDI-GFD7200

Cruising Charger Series OWNER S MANUAL

6. Electrical. 7. Settings. 8. Quick

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

SENSE SERIES SPEAKERS

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

ADI-125/750 ADI-125/1500 ADI-125/2500

Owner's Manual. mycharge name and logo are registered trademarks of RFA Brands RFA Brands. All Rights Reserved. Patent Pending.

Model WS-6020U Solar Station QUICK SETUP GUIDE

Full Function Display User s Manual

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

OWNER S MANUAL Please read and understand all precautions prior to use.

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.

CLASSIC II Portable Braking System

Select II Portable Braking System

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

LED FLUSHMOUNT CEILING FIXTURES

LIPSTICK CHARGER POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

WF-5110R True Sine Wave Inverter

Operator s Manual UNIVERSAL MULTI-UNIT CHARGER STANDARD & RAPID WARNING. ericssonz

OPERATING INSTRUCTIONS

OWNERS MANUAL JANUARY 2007 ISO

Operator Manual For use with WFCO ULTRA III Power Center WF-9900 Series (model number located on the door assembly label)

/09 Rev 1. Lionel Little Lines The Polar Express Set Owner s Manual

Intelligent Charging System Series

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

Directed Passive Keyless Entry System (PKE) Model 2102T Owner s Guide

Operator s Manual UNIVERSAL DESK CHARGER STANDARD & RAPID WARNING. ericssonz

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Operator Manual For use with WFCO ULTRA III Distribution Center WF-8900 Series (model number located on the door assembly label)

USER GUIDE. c--' c-' Remote. for #SED-10R

V2700Z OWNER S GUIDE.

Extension Hopper Installation & Operator s Instruction Manual for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

DC to AC Power Inverters

Cable/Gate Lock INSTALLATION MANUAL

DC to AC Power Inverters

AM-134, AM-140, AM-234, AM-240, AM-334, AM-340, AM-368

Extension Boot System

User s Manual Lineage LI3000 UPS K

User s Manual Legend SB825 UPS K

USE AND CARE GUIDE 7000 LUMEN TWIN HEAD LED WORKLIGHT WITH TRIPOD

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

Thermometer models / 00831A

Bluetooth Smart Speed/Cadence Sensor Instruction Manual

Wireless Thermometer model 00380

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

4 WAY WIRELESS REMOTE CONTROL SYSTEM. User Manual

owner s manual IsoCenter-NS Series Rackmount Shielded Isolation Transformer and Power Distribution Center

Owners Manual for TPMS plus GPS

Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

Operating Instructions

Owner s Manual. OutCast 1.2. The Ultimate Outdoor Speaker System

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

MIL-24/2600Q MIL-24/3200DQ

Thermometer model 00826

System User Manual. Revision SRM GMBH

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

Trigger. Battery Cap. Radar Icon. Power Button

OWNERS MANUAL JANUARY 2007 ISO

Transcription:

Issue 5 24/48 VOLT DC SWITCHING POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the VP-4124 and VP-4124-E, 24/48 Volt Power Supplies. FCC INFORMATION This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. SPECIFICATIONS The VP-4124 and VP-4124-E are fully regulated 24VDC, 4 Amp Power Supplies. The primary is protected by a 3 Amp slo-blo fuse and the 2 Amp outputs by auto-resetting fuses. The outputs are floating with respect to ground. The regulator will maintain 24 Volts +/- 2% over the rated range of input voltages and output loads. A greater than 4 Amp load on power up will cause the power supply to current limit. Short circuit protection is provided. Overvoltage is provided to limit the output voltage to approximately 28 Volts should a failure occur within the power supply. Outputs may be used in a series for 48V @ 2A. Applications The are designed to be used with All Valcom page control units Valcom one-way amplified speaker assemblies Any application where 24VDC filtered talk battery is required Design Features VP-4124: 115VAC, 60Hz input VP-4124-E: 230VAC, 50Hz input (preset at the factory for the specific unit) Hold Up Time: 350ms Power Line Ride Through (2) LPS outputs (24VDC @ 2A each) Can be used as a 24 Volt or 48 Volt power source Short circuit protection 1 947272

UL Listed for US and Canada FCC Class B CE Mark LED operational indicator EMI filtering 94.3% efficiency green technology Auto recovery overload protection 3 second power-up delay to drive large capacitive loads up to 40K µf Nominal Specifications General Efficiency: 94.3% Min @ 1A load 90% @ 4A full load Dimensions: 8.45"H x 4.70"W x 2.35"D (21.46cm H x 11.94cm W x 5.97cm D) Weight: 3.5 lbs. (1.59 kg) Input - VP-4124 115VAC Frequency: 60 Hertz 110 Watts Full Load Line Current: 1.0A Input - VP-4124-E 230VAC Frequency: 50 Hertz 110 Watts Full Load Line Current: 0.5A Output 100 Watts 24 Volts Current: 4 Amps, 2-2A outputs Fusing: Two - 2A Auto-reset polyswitch fuses Ripple & Noise: Less than 0.2% RMS Environmental Operating Temperature: Storage Temperature: Cooling: Humidity: Shock: Precautionary Notes: 0 to +40 o C -40C o to +85 o C Free Air Convection 10 to 90% (non-condensing) 10 G CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. INSTALLATION The VP-4124 and VP-4124-E are designed for wall mounting only. The unit should be mounted within 7 feet of an AC receptacle. Screw mounting plate to wall and position power supply on mounting plate via the mounting slots. See pages 5 and 6 for mounting instructions. Connections Connections to Valcom page control units are shown in Figure 1. When using the VP-4124 or VP-4124-E as a -24VDC power supply with Valcom page equipment, a strap may be added from the local ground terminal to both of the "+" outputs to provide an AC ground reference. When installing Valcom one-way amplified horns, connect the white and black wires of the horn to the power supply "-" and "+" terminals respectively. When installing Valcom one-way speakers, connect the "-24VDC" and "GND" terminals of the speaker to the "-" and "+" terminals respectively. Plug power supply into wall outlet. Power supply activates after 3 seconds delay. NOTE: Each -24VDC screw terminal is fused by a 2 Amp polyswitch automatic. Therefore, when connecting equipment to this power supply, the load should be distributed between the (2) 2 Amp output terminals (within 1.5 Amps) and each load should not exceed 2 Amps. TECHNICAL ASSISTANCE When trouble is reported, verify the unit is properly connected and there are no broken connections leading to this unit. Assistance in troubleshooting is available from the factory. When calling, you should have a VOM and a test set and call from the job site. Call (540) 563-2000 and press 1 for Technical Support or visit our website at http://www.valcom.com. Valcom equipment is not field repairable. Valcom, Inc. maintains service facilities in Roanoke, VA. Should repairs be necessary, attach a tag to the unit clearly stating company name, address, phone number, contact person and the nature of the problem. Send the unit to: Valcom, Inc. Repair and Return Dept. 2

5614 Hollins Road Roanoke, VA 24019-5056 TROUBLESHOOTING CHART 1. No output PROBLEMS 2. LED pulses in reset mode SOLUTIONS a. Verify AC present at receptacle. b. Remove DC load and check for 24VDC using a VOM. a. Locate and correct short circuit in output wiring. b. Verify total equipment power consumption does not exceed 4 Amps. Typical Page Control Unit A Ground A Battery B Ground B Battery Optional Ground Reference Strap To other page units or amplified speaker assemblies Power Supply FIGURE 1 Local GND -+ -+ 24V Outputs VALCOM LIMITED WARRANTY Valcom, Inc. warrants its products only to the original purchaser, for its own use, to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment. This Limited Warranty obligation shall be limited to the replacement, repair or refund of any such defective device within the warranty period, provided that: 1. inspection by Valcom, Inc. indicates the validity of the claim; 2. the defect is not the result of damage, misuse or negligence after the original shipment; 3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts and labor will be applied to units defaced or physically damaged); 4. freight charges for the return of products to Valcom are prepaid; 5. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to additional charges for parts and labor). This Limited Warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation, maintenance, installation, removal or use of the product. The maximum liability of Valcom under this warranty is limited to the purchase price of the specific Product covered by the warranty. Disclaimer. Except for the Limited Warranty provided herein, the product is provided as-is without any warranty of any kind whatsoever including, without limitation, any WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT. This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point. Headquarters: Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019-5056 Phone: (540) 563-2000 FAX: (540) 362-9800 3

CONNECTIONS FOR USE AS A 48 VOLT DC POWER SOURCE Output at 48 Volts 100 Watts 48 Volts Current: 2 Amps, 1-2A output Fusing: Two - 2A Auto-reset polyswitch fuses Ripple & Noise: Less than 0.2% RMS Connections (48 Volts) To use the unit as a 48 Volt power source, strap the center "+" and "-" terminals together (see Figure 2). Optional Ground Reference Strap Terminals connected together to provide a 48 Volt output Power Supply Local GND -+ -+ 48V Output To Valcom Page Control (+) GND (-) 48VDC Green Red Black White V-1038 30 Watt Horn FIGURE 2 Use Steps 1 through 3 and Figures 3 and 4 to mount the power supply on a wall or other surface capable of supporting the weight of the supply (approximately 5 pounds). Carefully unpack the power supply and inspect for shipping damage. Select a location for installation of the power supply in a clean, dry, vibration-free area with moderate temperature within six feet of an approved AC outlet. 1. Using the mounting bracket (see Figure 3) as a template, mark the two slotted holes on the surface of the wall. 2. Using mounting hardware capable of supporting approximately 5 pounds, mount the bracket to the wall ensuring that the mounting holes are oriented as shown in Figure 3. Top Slotted Holes Bottom Figure 3. Bracket 4

3. Using Figure 4 as a guide, mount the power supply onto the mounting bracket. 5