INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Similar documents
Simulation Analysis of Closed Loop Dual Inductor Current-Fed Push-Pull Converter by using Soft Switching

BIDIRECTIONAL FULL-BRIDGE DC-DC CONVERTER WITH FLYBACK SNUBBER FOR PHOTOVOLTAIC APPLICATIONS

II. ANALYSIS OF DIFFERENT TOPOLOGIES

A Reduced switch count Soft-Switching Current-Fed Full-Bridge Isolated DC/DC Converter for Fuel Cell Vehicles

Power Electronics Projects

A PARALLEL SNUBBER CAPACITOR BASED HIGH STEP UP ISOLATED BIDIRECTIONAL FULL BRIDGE DC TO DC CONVERTER

POWER ELECTRONICS & DRIVES

Inverter with MPPT and Suppressed Leakage Current

A Novel DC-DC Converter Based Integration of Renewable Energy Sources for Residential Micro Grid Applications

Implementation of Bidirectional DC-DC converter for Power Management in Hybrid Energy Sources

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 02, 2016 ISSN (online):

Analysis and Design of Improved Isolated Bidirectional Fullbridge DC-DC Converter for Hybrid Electric Vehicle

Design and Development of Bidirectional DC-DC Converter using coupled inductor with a battery SOC indication

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

Design of Three Input Buck-Boost DC-DC Converter with Constant input voltage and Variable duty ratio using MATLAB/Simulink

The Master of IEEE Projects. LeMenizInfotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry

A NEW ZCS-ZVS SINGLE PHASE PFC CONVERTER WITH A LCD SNUBBER FOR OUTPUT VOLTAGE REGULATION

INVESTIGATION AND PERFORMANCE ANALYSIS OF MULTI INPUT CONVERTER FOR THREE PHASE NON CONVENTIONAL ENERGY SOURCES FOR A THREE PHASE INDUCTION MOTOR

Multi-Port DC-DC Converter for Grid Integration of Photo Voltaic Systems through Storage Systems with High Step-Up Ratio

Fuzzy logic controlled Bi-directional DC-DC Converter for Electric Vehicle Applications

SPIRO SOLUTIONS PVT LTD POWER ELECTRONICS 1. RENEWABLE ENERGY PROJECT TITLES I. SOLAR ENERGY

Raised Step-Up Converter Using Three-Winding Coupled Inductor for Fuel Cell Potential Source Purposes

FOUR SWITCH THREE PHASE BRUSHLESS DC MOTOR DRIVE FOR HYBRID VEHICLES

Soft Switching of Two Quadrant Forward Boost and Reverse Buck DC- DC Converters Sarath Chandran P C 1

Performance Analysis of Bidirectional DC-DC Converter for Electric Vehicle Application

A Bidirectional Universal Dc/Dc Converter Topology for Electric Vehicle Applicationsand Photovoltaic Applications

DC-DC BIDIRECTIONAL ISOLATED CONVERTER FOR FUEL CELLS AND SUPER-CAPACITORS HYBRID SYSTEM

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

A NOVEL MULTIPHASE BIDIRECTIONAL FLY-BACK CONVERTER TOPOLOGY IS APPLIED TO INDUCTION MOTOR DRIVE

[Patil, 7(2) April-June 2017] ISSN: Impact Factor: 4.015

Design of Four Input Buck-Boost DC-DC Converter for Renewable Energy Application

Isolated Bidirectional DC DC Converter for SuperCapacitor Applications

Battery-Ultracapacitor based Hybrid Energy System for Standalone power supply and Hybrid Electric Vehicles - Part I: Simulation and Economic Analysis

Implementation Soft Switching Bidirectional DC- DC Converter For Stand Alone Photovoltaic Power Generation System

BIDIRECTIONAL DC-DC CONVERTER FOR INTEGRATION OF BATTERY ENERGY STORAGE SYSTEM WITH DC GRID

POWER ELECTRONICS TITLES LeMeniz Infotech

Dual power flow Interface for EV, HEV, and PHEV Applications

Australian Journal of Basic and Applied Sciences

A.Arun 1, M.Porkodi 2 1 PG student, 2 Associate Professor. Department of Electrical Engineering, Sona College of Technology, Salem, India

ISSN Vol.07,Issue.11, August-2015, Pages:

1. RENEWABLE ENERGY I.SOLAR ENERGY PROJECT TITLES WE CAN ALSO IMPLEMENT YOUR OWN CONCEPT/IDEA

A Zero-Voltage-Transition Bidirectional DC/DC Converter

Power System Stability Analysis on System Connected to Wind Power Generation with Solid State Fault Current Limiter

DC-DC CONVERTER. 5.1 Advantages & Disadvantages of DC-DC Converters

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

CHAPTER 1 INTRODUCTION

LOAD SHARING WITH PARALLEL INVERTERS FOR INDUCTION MOTOR DRIVE APPLICATION

PASSIVE SOFT SWITCHING SNUBBER FOR SPWM INVERTERS

A Novel Hybrid PV/Wind/Battery based Generation System for Grid Integration

Design and Simulation of Grid Connected PV System

A Novel ZVS/ZCS Bidirectional DC DC Converter for DC Uninterruptable Power Supplies

Research Paper MULTIPLE INPUT BIDIRECTIONAL DC-DC CONVERTER Gomathi.S 1, Ragavendiran T.A. S 2

High-Voltage, High-Current DC- DC Converters Applications and Topologies

FAULT ANALYSIS FOR VOLTAGE SOURCE INVERTER DRIVEN INDUCTION MOTOR DRIVE

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

An Improved Efficiency of Integrated Inverter / Converter for Dual Mode EV/HEV Application

Energy Conversion and Management

NOVEL MODULAR MULTIPLE-INPUT BIDIRECTIONAL DC DC POWER CONVERTER (MIPC) FOR HEV/FCV APPLICATION

A Study of Suitable Bi-Directional DC-DC Converter Topology Essential For Battery Charge Regulation In Photovoltaic Applications

Review & Study of Bidirectional of DC-DC Converter Topologies for Electric Vehicle Application


Bidirectional Intelligent Semiconductor Transformer

Abstract. Introduction:

International Journal of Advance Research in Engineering, Science & Technology

Isolated Bidirectional DC DC Converter for SuperCapacitor Applications

Design and Implementation of Non-Isolated Three- Port DC/DC Converter for Stand-Alone Renewable Power System Applications

Battery Charger for Wind and Solar Energy Conversion System Using Buck Converter

Model Predictive Control of Back-to-Back Converter in PMSG Based Wind Energy System

Hybrid Energy Powered Water Pumping System

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid

Optimal Design Methodology for LLC Resonant Converter in Battery Charging Applications Based on Time-Weighted Average Efficiency

Design of High Performance and High Efficiency DC-DC Converter for Hybrid Electric Vehicles

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

Unified Power Quality Conditioner with Electric Double Layer Capacitor

DESIGN AND ANALYSIS OF CONVERTER FED BRUSHLESS DC (BLDC) MOTOR

Simulation of Fully-Directional Universal DC- DC Converter for Electric Vehicle Applications

PERFORMANCE AND ENHANCEMENT OF Z-SOURCE INVERTER FED BLDC MOTOR USING SLIDING MODE OBSERVER

5 kw Multilevel DC-DC Converter for Hybrid Electric and Fuel Cell Automotive Applications

SOLAR PHOTOVOLTAIC ARRAY FED WATER PUMP RIVEN BY BRUSHLESS DC MOTOR USING KY CONVERTER

Input-Series-Output-Parallel Connected DC/DC Converter for a Photovoltaic PCS with High Efficiency under a Wide Load Range

To Increase System Efficiency for Portable Electronics Devices with DC-DC Converter

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Modeling and Simulation of Multi-input Bi-directional Boost Converter for Renewable Energy Applications using MatLab/Simulink

A ZVS Interleaved Boost AC/DC Converter Using Super Capacitor Power for Hybrid Electrical Vehicles

A Novel Integration of Power Electronics Devices for Electric Power Train

POWER ELECTRONIC CONTROL OF INDUCTION GENERATOR USED IN SMALL HYDRO POWER SYSTEM

Hybrid Three-Port DC DC Converter for PV-FC Systems

International Journal of Advance Research in Engineering, Science & Technology

BI-DIRECTIONAL DC-DC CONVERTER FOR ENERGY STORAGE IN SOLAR PV SYSTEM

Implementation of Bidirectional DC/AC and DC/DC Converters for Automotive Applications

Power Flow Management and Control of Hybrid Wind / PV/ Fuel Cell and Battery Power System using Intelligent Control

EXTENDED PHASE SHIFT CONTROL OF ISOLATED BIDIRECTIONAL DC-DC CONVERTER FOR RENEWABLE ENERGY SOURCES CONNECTED TO MICRO GRID

One-Cycle Average Torque Control of Brushless DC Machine Drive Systems

EMS of Electric Vehicles using LQG Optimal Control

Intelligent Power Management of Electric Vehicle with Li-Ion Battery Sheng Chen 1,a, Chih-Chen Chen 2,b

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Full Bridge Dc Dc Converter With Planar Transformer And

A Bidirectional DC-DC Battery Interface for EV Charger with G2V and V2X Capability

Transcription:

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET) Proceedings of the 2 nd International Conference on Current Trends in Engineering and Management ICCTEM -2014 ISSN 0976 6545(Print) ISSN 0976 6553(Online) Volume 5, Issue 8, August (2014), pp. 174-181 IAEME: www.iaeme.com/ijeet.asp Journal Impact Factor (2014): 6.8310 (Calculated by GISI) www.jifactor.com IJEET I A E M E SNUBBERLESS CURRENT FED HALF BRIDGE ISOLATED CONVERTER FOR FUEL CELL APPLICATIONS Raghavendra H S 1, Nagaraj A M 2 1 PG Student, Dept of EEE, DSCE, Bangalore-78 2 Asso. Prof. Dept of EEE, DSCE, Bangalore-78 ABSTRACT This paper presents a new class of current fed converter for a power electronic interface for fuel cell applications, photovoltaic inverters, etc. The proposed circuit shows advantage over conventional hard switched current fed half bridge isolated dc/dc converter and active clamped ZVS current fed half bridge isolated dc/dc converter with a simple solution to switch turn-off voltage spike problem without any additional snubber as in active clamped ZVS converter. It leads in reduced size, lower cost, and higher efficiency. A formal mathematical description was arriving at design parameters is also touched upon, for 250W converter. The results of the proposed topology are study in detail through simulation in PSIM 9.0 platform and results are presented with efficiency of 95%. Keywords: Fuel cell inverter, Half bridge isolated converter, current fed converter, Zero current switching (ZCS), dc/dc converter. I. INTRODUCTION With the concept of smart grid, smart metering, smart buildings, alternative energy sources, transportation electrification, hybrid micro-grid, etc., efficient, economical, and compact power conversion is getting increasing importance, and power electronics industries are revoking. So many alternative energy sources have been implementing as a hybrid with a present energy sources or some using as a complete alternative to them. In those alternative fuel cells are more dominating which as huge applications such as stationary loads, automotive applications, and interfaces with electric utilities due to the several advantages over conventional other alternative sources. To effectively utilize energy resources, the development of fuel cell generation systems is becoming increasingly important for global environment. The fuel cell, a clean and renewable energy source, has recently been revived and shows promising results for applications as small as cellular phones to 174

as large as utility power generations. This particular fuel cell system is intended for household standalone power generation. Fuel cells output is continuous and secure as long as the fuel supply is maintained unlike PV and wind. Fuel cell vehicles are true zero-emission vehicles and which are getting commercial attraction these days. Energy storage in gas (H2 and O2) form relieves from issues like disposal, lifetime, leakage, deep discharging, overcharging, and capacity variations with season in case of battery storage. Therefore, fuel cell systems will dominate in future smart grid. The fuel cell systems consist of front end dc/dc converters and followed by an inverter to converter the obtained dc to ac loads. This is shown in block diagram in Fig. 1(a). A fuel cell stack consists of an individual low-voltage cell as in block {1}; therefore, from a cost standpoint, minimum number of cells used to reduce the cost. Most of the fuel cell manufacturers have chosen a standard voltage of 28 43 Vdc. Fig. 1 (a): Block diagram of fuel cell power system This low-voltage characteristic requires that the output voltage of the fuel cell stack (input voltage of the inverter) should be boosted before it is inverted to ac source as in block {2}, so inverter is added with a dc dc converter on the front end. Sinusoidal AC source is again converted back to DC with bridge circuits as in block {3}, before delivering to load {5} supply will filtered for requirement {4}. Front-end dc/dc conversion is highly important in fuel cell inverters because its efficiency dominates the overall system efficiency. Selection of efficient and high performance converters is important. Many such converter and inverter topologies are presented and compared based on their performance and other parameters. Looking at the configurations of the circuits they are mainly of current fed and voltage fed converter configurations. The conventional voltage fed converter configurations are not optimal due to the several ripple current characteristic of the fuel cell. In order to handle the ripple current, a large number of electrolyte capacitors are essentially required, resulting in an increase in the overall system size and manufacturing cost. Moreover, in voltage fed converters, high winding ratio between the primary and secondary sides of the high frequency transformer is necessary because the boosting action is only performed by the winding ratio and it also causes the snubber to be enlarged to handle the surge at turn-off switching instants. Whereas, in the current fed converters using an inductor decreases the current ripple as well as the electrolyte capacitor size. An active boosting action can also be achieved with relatively low winding ratio. Therefore, for the fuel cell system current fed converter is a better choice than the conventional voltage fed converter. In current fed converter topologies switching of devices is being experimenting in order to obtain the better efficiency from hard switching to soft switching using zero current switching (ZCS) and zero voltage switching (ZVS) techniques. Fig. 1(b) shows conventional hard switching current fed technique circuit, due to switching losses in this technique of switching it is preferable to use soft switching technique [3]. 175

Fig. 1(b): Conventional hard switched current fed half bridge isolated dc/dc converter Fig. 1(c): Lossless snubber current fed converter Fig. 1(d): Active lossless snubber current fed converter Fig. 1(e): Active clamping current fed half bridge converter Fig. 1(b) show the lossless snubber current fed converter which will operate only at turn off and its circuit is too much complicated, Fig. 1(c) shows the active lossless snubber converter here both turn on and turn off operates at zero-voltage switching(zvs) but the voltage across the auxiliary switches are twice of the main switch[2]. 176

Fig. 1(d) shows the active clamping current fed half bridge converter. This circuit switches operates at zero voltage switching. This circuit increases the current stresses across the components and introduces circulating current that leads to higher switch rms current. With that, it requires two additional active switches, two snubber capacitors, and one high- frequency (HF) capacitor of large value, which increases the component count and converter complexity. In this paper, a fuel cell generation system with a ZCS current fed half- bridge dc/dc converter with full bridge on secondary has been implemented. The proposed converter boosts the low output voltage (30 Vdc) of fuel cell stack to high dc voltage, such as 500 Vdc in a high efficient manner. The proposed 250 w converter analyses and design are verified by simulation results using PSIM 9.0. The rest of the paper addresses the operation principle, design consideration and simulation results. II. SYSTEM DESCRIPTION Proposed zero-current-switching (ZCS) current fed half-bridge dc/dc converter is shown in fig 2. In this converter voltage across the switches is clamped without an active clamp or passive snubber, which leads in reduction in size and cost. It improves the converter efficiency by ZCS of primary devices, zero-current turn-on of all devices, and natural commutation of secondary diodes and body diodes of primary devices. Switching transition losses are significantly reduced. It has negligible circulating current and lower conduction losses and, therefore, is expected to show better light load efficiency than hard switching and active-clamped circuits. This ZCS current fed half bridge dc/dc converter is having bidirectional ability and can be used for battery storage, fuel cell vehicles, and hybrid electric vehicles. Circuit consists of a current fed half bridge converter on the primary side of the high frequency transformer, and secondary side having full bridge converter [1]. Fig. 2: Proposed ZCS current fed half-bridge dc/dc converter Converter consists of a half bridge converter at primary side converting constant Vdc to AC voltage with the help of two switches S1, S2. Series inductor (Ls) is used for boosting purpose and to decrease the ripple current. Specially designed high frequency transformer of turns ratio 1:n is to used to step up the voltage to n times the converted voltage. Then with the full bridge at the secondary side of transformer the AC voltage is then converted back constant DC voltage, the full bridge circuit consists of IGBT s as the switches used accordingly to obtain desired output. The gating sequence of the primary switches and secondary switches are inter related, switch S3 and S6 turn on before switch S2 turns off meanwhile switch S4 and S5 turn on before switch S1 turns off. The primary switch S1 and S2 are operated with gating signal which are 180 phase shift and the reflected output voltage Vo/n appears across the transformer primary. This diverts the current from the primary switch into the transformer, causing the transformer current to decrease to zero. Once current decreases below zero, the body diode across the switch starts conducting, and the gating signal is removed, causing its ZCS turn-off. 177

III. DESIGN CONSIDERATION To verify the feasibility of circuit, the proposed converter built on following specifications after designing [1]: Input voltage: Vin = 30 V; Output voltage: Vout = 500 V; Output power: Po = 250 W; Operating frequency: f = 100K Hz; Voltage conversion ratio: n =4; Series inductor: Ls = 15µH; L1 and L2 = 228µH; Load resistor = 1KΩ; Output capacitor = 2.6µF; Primary switch duty ratio = 0.76; Secondary switch duty ratio = 0.05; After considering all these parameters and simulated using PSIM 9.0 simulation software the overall efficiency obtained is 95%. IV. SIMULATION RESULTS In this section, simulation results for a 250 W converter design are verified using PSIM 9.0. Fig. (7) shows the PSIM simulation circuit with designed parameters. The following assumptions are made for converter analysis: Inductors L1 and L2 are large enough to maintain constant current through them Magnetizing inductance of the transformer is infinitely large All the components are ideal Ls is the leakage inductance of the transformer or a secondary inductor that includes the transformer leakage inductance. Fig. 7: Proposed ZCS Current Fed Half Bridge Dc/Dc Converter 178

Fig. 8: Input Current Current flowing through the boost inductors is exactly half of the input current, which is obtained because of the 180 phase shift obtained from primary switches. The phase shifting can be clearly observed in Fig. 9. Fig. 9: Current in the Boost Inductors Fig. 10: Current through the primary of the transformer Fig. 11: Current in the primary side switches showing ZCS turn-off 179

Fig. 11 shows the each switch current reaches zero naturally and anti-parallel body diode conducts, causing a zero voltage across it. Therefore, gate signal is removed without any additional snubber needed for switch turn-off. Fig. 12: Current Flowing Through the Secondary- Side Switches Fig. 12 shows the zero current turn-on of secondary switches as the current starts conducting from zero and builds up with a slope that depends upon the reflected value of Ls. Fig. 13: Voltage across the secondary switch Fig. 14: Voltage across the primary switch The voltage across the primary switch will be Vo/n, where n is transformer turn s ratio. Which can verified using Fig. 13 and Fig. 14. Fig. 15: Waveform showing output voltage 180

V. CONCLUSION In this paper, a current fed half-bridge isolated dc/dc converter with operates in ZCS proposed for fuel cell applications. In particular, compare with other previous converter topologies this converter is more efficient with following advantages low cost, simple circuit and less components. The following converter has been verified with PSIM 9.0 simulation tool and the efficiency of 95% has been recorded. VI. REFERENCES [1] Udupi R. Prasanna, Akshay K. Rathore, and Sudip K. Mazumder, Novel Zero-Current- Switching Current-Fed Half-Bridge Isolated DC/Dc Converter For Fuel-Cell-Based Applications, IEEE Trans. Energy Conversion, vol. 24, no. 4, pp. 1658-1668, jul/aug 2013. [2] A. K. Rathore and S. K. Mazumder, Novel zero-current switching current-fed half-bridge isolated DC/DC converter for fuel cell based applications, inproc. IEEE Energy Convers. Congr. Expo., 2010, pp. 3523-3529. [3] S. J. Jang, C. Y. Won, B. K. Lee, and J. Hur, Fuel cell generation system with a new active clamping current fed half-bridge converter, IEEE Trans. Energy Convers., vol. 22, no. 2, pp. 332-340, Jun. 2007. [4] T Y. Lembeye, V. D. Bang, G. Lefevre, and J. P. Ferrieux, Novel half-bridge inductive DC-DC isolated converters for fuel cell applications, IEEE Trans. Power Electron., vol. 24, no. 1, pp. 203-210, Mar. 2009. [5] M. Nymand and M. A. E. Andersen, High-efficiency isolated boost DC-DC converter for high-power low-power fuel cell applications, IEEE Trans. Ind. Electron., vol.57, no. 2, pp 505-514, Feb. 2010. [6] J-M Kwon and B-H kwon, High step-up active-clamp converter with input current doubler and output-voltage doubler for fuel cell power systems, IEEE Trans. Power Electron., vol. 24, no. 1, pp. 108-115, Jan. 2009. 181