Comparison of 1½- and 2-Inch Suction Hose When Used With Portable Pumps. David V. Haston, P.E., Mechanical Engineer

Similar documents
Small generators frequently are used in remote sites and

Merv Eriksson Project Leader. Sharon Kosmalski Project Assistant. July 2006

Airtanker. Drop Guides. Ground Pattern Performance of the Western Pilot Services Dromader. Figure 1 39% 4 7/8 x 3 Original Photo 9.25 x 6.

Airtanker. Drop Guides. Ground Pattern Performance of the Erickson Air Crane Paul Solarz, Program Leader, and Cammie Jordan, Project Assistant

Highlights... Fire. Better Performance of Aerial Ignition Spheres Through Proper Storage and Handling. Technology & Development Program

The Introduction to Mechanized Trail Equipment video will be distributed by the San

Quarterly Hogs and Pigs

Fats and Oils: Oilseed Crushings, Production, Consumption and Stocks

Fire. The Heli-Claw: A New Way To Transport Mulch for Erosion Control. Technology & Development Program. Tim Lynch, Project Leader

Fats and Oils: Oilseed Crushings, Production, Consumption and Stocks

Quarterly Hogs and Pigs

Missoula Technology and Development Center

Fats and Oils: Oilseed Crushings, Production, Consumption and Stocks

Livestock Operations Summary. April United States Department of Agriculture. National Agricultural Statistics Service.

Quarterly Hogs and Pigs

UPPER MIDWEST DAIRY NEWS

Fats and Oils: Oilseed Crushings, Production, Consumption and Stocks

Safe Use of Cranes and Hoists. Susan Jenkins and Ian Barlow, Nez Perce National Forest; Bob Beckley, Project Leader

Fats and Oils: Oilseed Crushings, Production, Consumption and Stocks

Recreation, Transportation

Quarterly Hogs and Pigs

Sheep and Goats. Final Estimates United States Department of Agriculture. National Agricultural Statistics Service

EVALUATION OF THE AQUA-DUK PUMP

This Tech Tip explains demand charges, how they are

Utility Vehicle Flamethrower Apparatus

Motor Vehicle Use Map 2009

Manufacturer Submission Procedure for the Qualification Testing of General-purpose, Screen, and Locomotive Spark Arrester Exhaust Systems

DECISION DECISION RATIONALE

Field crews working away from their offices or work

4-H Newsletter. Crook County

Quarterly Hogs and Pigs

Lucky Peak Greenhouse Top Pruner

Highway 18 BNSF Railroad Overpass Feasibility Study Craighead County. Executive Summary

STANDARD TEST PROCEDURE FOR GENERAL PURPOSE SPARK ARRESTERS

Criterion 6 Indicator 28: Total and Per Capita Consumption of Wood and Wood Products in Roundwood Equivalents

Helicopter Dip Tank Capabilities and Users Guide. Ronald Tam, Mechanical Engineering Technician

Pump Service Testing

New Jersey Motor Vehicle Commission

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE STANDARD FOR SPARK ARRESTERS FOR INTERNAL COMBUSTION ENGINES

2011 Soft Red Winter Wheat Quality Survey. Final

All-Terrain Trail-Trailer and Sprayer Modules

Program & Services Guide The Energy to Serve You

Maryland Regulations on Transporting Horses

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE SPECIFICATION FOR PUMP, LIGHTWEIGHT, PORTABLE

This publication is a supplement to Oregon

INVITATION TO BID FUEL PRODUCTS

"Double Colored Man Tou" steamed buns, photo by Roy Chung Soft Red Winter Wheat Quality Survey

PUMP PERFORMANCE TEST

DATE Updated November 30, 2007

JOB CLASSIFICATION: Heavy Equipment Operator

SANDAG Vanpool Program Guidelines as of February 2018

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions

Woodland owners routinely want to measure property acreage,

DOT EMPLOYMENT APPLICATION (49CFR ) Answer ALL questions please print

Motor Vehicle Use Map

Fire Department Access & Water Supply

Request For Bids. Sewer Cleaning Truck

Why calibrate? Calibrating your spray equipment

City of Minnetonka Maximum Parking Regulations Urban GIS. Group Members Brad Johnston Mark Kelley Jonathan Winge

Driver License. Requirements

Citrus Herbicide Boom Sprayer Calibration 1

Motorcycle ATV Braking Data Analysis. Progress Report

US 81 Bypass of Chickasha Environmental Assessment Public Meeting

FACT SHEET. Lighting and Marking Recommendations for Buggies and Wagons AEX

US FOREST SERVICE TECHNOLOGY AND DEVELOPMENT CENTER PROJECT UPDATE

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

Memorandum Federal Highway Administration

Driver's Application For Employment

Application Equipment and Techniques 1

ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

Project Number 56b January Hard Cab Design for HMMWV

Civil Engineer. Tasks

Form UST FP-290 Notification for Underground Storage Tanks Regulated Under 527 CMR 9.00

Employment Application

Calibration of Herbicide Applicators 1

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

MIFACE INVESTIGATION: #03MI066

2018 Flue-Cured Tobacco Production Guide Disease Resistance Tables Table 4. Flue cured tobacco variety reactions to Black Shank.

Ready or Not? Get Ready with A Tractor Operator Checklist 1

DRIVER'S APPLICATION FOR EMPLOYMENT

Estimated Annual Timber Products Consumption in Major End Uses in the United States,

Specification for Sealless Horizontal End Suction Centrifugal Pumps for Chemical Process

MCE SPECIAL MEETING Friday, September 28, :00 A.M. Agenda Page 1 of 2

Internal Audit Report. Fuel Consumption Oversight and Coordination TxDOT Internal Audit Division

North Lyon County Fire Protection District. Seasonal Firefighter Job Description

Guide to Determine What Weight Show Pig to Purchase

American Driving Survey,

Automatic Number Plate Recognition Cars (ANPR), Penalty Charge Notice (PCN) Petition from Taxi/Hackney Carriage Drivers in Dunstable

EEOC S RELATIONSHIP WITH STATE & LOCAL FAIR EMPLOYMENT PRACTICES AGENCIES

DEPARTMENT OF TRANSPORTATION

AGENDA INTERCITY TRANSIT AUTHORITY WORK SESSION January 20, :30 P.M. 1) APPROVAL OF AGENDA 1 min.

Instructions for Installation, Operation Care and Maintenance

Valves in Irrigation Systems 1

Valves in Irrigation Systems 1

New Jersey Motor Vehicle Commission

Petroleum Storage Tank Release Detection and Inventory Control

APPENDIX IX-H COMBINED TAX WITHHOLDING TABLES FOR USE WITH THE SUPPORT GUIDELINES

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 10 Apparatus Service Tests Revised

Choctaw Nation of Oklahoma Fleet Safety Program

CHAPTER 14 TRAFFIC CODE THE MINNESOTA HIGHWAY TRAFFIC REGULATION ACT.

Transcription:

Fire Management Tech Tips United States Department of Agriculture Forest Service Technology & Development Program December 2006 5100 0651 1308 SDTDC Comparison of 1½- and 2-Inch Suction Hose When Used With Portable Pumps David V. Haston, P.E., Mechanical Engineer Tech Tip Highlights There is no advantage to using 2-inch suction hose under operating conditions found most frequently in the field. At higher lift conditions, 2-inch suction hose results in less deterioration of pump performance than 1½-inch suction hose, particularly when a foot valve is used. In order to improve the performance of portable pumps, use a check-and-bleeder valve on the pump discharge instead of a foot valve on the pump intake. Introduction The San Dimas Technology and Development Center (SDTDC) was asked to perform an evaluation of suction hose and determine if there would be an advantage in using 2-inch suction hose instead of 1½-inch suction hose with portable pumps such as the Mark 3. Suction hose is used to draft water from natural water sources and from portable tanks during wildland firefighting operations. The Mark 3 Pump Kit (NFES 0870) is supplied through the National Interagency Support Cache System. In addition to the pump, the kit comes with one 10-foot length of 1½-inch suction hose (NFES 0115), a foot valve (NFES 0212), a check-and-bleeder valve (NFES 0228), as well as other components. A foot valve is used on the suction hose intake to maintain prime and to prevent reverse waterflow through the pump on an uphill hose lay when the pump is not running. A typical foot valve is shown in figure 1. Suction strainers (also known as bell strainers) also are used on the intake of suction hoses and prevent contact with the bottom of the water source. See figure 2. Foot valves and suction strainers have screens that prevent the intake of pebbles, rocks, and other material harmful to the pump and engine plumbing. Check-and-bleeder valves are installed on the discharge of a pump and perform the same function as a foot valve when the pump is not running they maintain prime and shut off automatically to prevent backflow through the pump (holding water in an uphill hose lay). Figure 1 Foot valve. Figure 2 Suction strainer. Figure 3 Check-and-bleeder valve. For additional information, contact: Fire Management Program Leader, San Dimas Technology & Development Center, 444 East Bonita Avenue, San Dimas, CA 91773-3198; Phone 909-599-1267; TDD; 909-599-2357; FAX: 909-592-2309 Lotus Notes: Mailroom WO SDTDC@FSNOTES Intranet (web site): http://fsweb.sdtdc.wo.fs.fed.us Internet e-mail: mailroom_wo_sdtdc@fs.fed.us 1

Test Conditions Testing was conducted with a Mark 3 pump (qualified to U.S. Department of Agriculture (USDA) Forest Service specification 5100-274) 1. Two hose sizes (1½ and 2 inch) and two hose lengths (10 feet and 24 feet) were tested. The 24-foot length of hose was made up of three individual 8-foot sections. For each test condition (hose length and lift), testing was performed with two different hose-end conditions a foot valve and a suction strainer. Note: A 2½-inch NH suction strainer was adapted to a 2-inch NPSH because a 2-inch suction strainer was not available. The following scenarios/conditions were evaluated: 10-foot-long suction hose tested at 2½-foot lift (4 tests). 24-foot-long suction hose tested at 2½-foot lift (4 tests). 24-foot long suction hose tested at 10-foot lift (4 tests). Lift is defined as the vertical distance between the water source surface and the centerline of the pump. The 2½-foot lift represents an operating condition found frequently in the field, and the 10-foot lift condition is consistent with the test requirements of National Fire Protection Association (NFPA) 1906, Standard for Wildland Fire Apparatus, 2006 edition. NFPA 1906 requires that priming and pumping tests be conducted at a 10-foot lift with a minimum 20-foot length of suction hose equipped with a suction strainer. Portable pumps should be capable of priming and pumping water from a 17-foot lift at sea level. Tests were conducted at SDTDC, at an elevation of approximately 1,000 feet. Test Methodology 1. A valve was installed on the discharge side of the pump, and pressure and flow transducers were installed between the pump and the valve for accurate data measurement. 2. The pump was primed and set to maximum throttle (maximum performance). Each test was started with the valve completely open, allowing the pump to operate at maximum flow rate and minimum pressure. 3. The valve was then closed slowly. As the valve closed, pressure increased and flow decreased. The valve was closed until maximum pressure (maximum pump close-off pressure) was attained and flow stopped. Pressure and flow were monitored continuously and automatically recorded during the test. 4. Pump performance curves were created from the pressure and flow data. 2

Test Results 2½-foot lift, 10-foot length of suction hose Note: This test condition represents a pump being used with the standard cache kit contents, i.e., close to the water source. Suction strainer: There was no difference in performance between 1½-inch and 2-inch suction hose. Foot valve: There was a difference in performance between 1½-inch and 2-inch suction hose at operating pressures below 100 pounds per square inch (psi), reaching a maximum difference of 16 gallons per minute (gal/min) at wide-open flow. Above 100 psi, there was no difference in performance between the two hose sizes. Figure 4 shows the graphical results of the test data. Figure 4 Pump performance for a 10-foot length of suction hose at a 2½-foot lift. 3

2½-foot lift, 24-foot length of suction hose Note: This test condition represents a pump being used at a greater distance from the water source with minimal elevation gain from the water source to the pump. Suction strainer: There was a slight difference in performance between 1½-inch and 2-inch suction hose at very low operating pressures (below 50 psi). Above 50 psi, there was no difference in performance between the two hose sizes. Foot valve: There was a difference in performance between 1½-inch and 2-inch suction hose below 150 psi, reaching a maximum difference of 26 gal/min at wide-open flow. Above 150 psi, there was no difference in performance between the two hose sizes. Figure 5 shows the graphical results of the test data. Figure 5. Pump performance for a 24-foot length of suction hose at a 2½-foot lift. 4

10-foot lift, 24-foot length of suction hose Suction strainer: There was a difference in performance between 1½-inch and 2-inch suction hose at pressures below 100 psi, reaching a maximum difference of 14 gal/min at wide-open flow. Above 100 psi, there was no difference in performance between the two hose sizes. Foot valve: There was a significant difference in performance between 1½-inch and 2-inch suction hose below 150 psi, reaching a maximum difference of 33 gal/min at wide-open flow. Above 150 psi, there was no difference in performance between the two hose sizes. Figure 6 shows the graphical results of the test data. Figure 6 Pump performance for a 24-foot length of suction hose at a 10-foot lift. 5

Conclusions At lifts up to 10 feet and suction hose lengths up to 24 feet: o Regardless of end condition (foot valve or suction strainer) there was no difference between 1½-inch suction hose and 2-inch suction hose above 150 psi operating pressure. o When suction strainers were used, there was no difference in performance between 1½-inch and 2-inch suction hose above 100 psi operating pressure. Under operating conditions found most frequently in the field, i.e., low lifts with pump close to water source at pressures above 100 psi, there was no advantage to using 2-inch suction hose. As lift increased, 2-inch suction hose resulted in less deterioration of pump performance than 1½-inch suction hose, particularly when a foot valve was used. There was no decrease in performance with 2-inch suction hose when lift was increased from 2.5 feet to 10 feet, with or without a foot valve. 1½-inch suction hose has over four times the friction loss of 2-inch suction hose. Friction loss is negligible for short lengths of suction hose, but starts becoming important as hose length increases. Recommendations Based on the results of this evaluation, there is no need to change the suction hose size in the Mark 3 Pump Kit. Suction strainers offer a performance advantage over foot valves and should be considered for addition to the Mark 3 Pump Kit. If 1½-inch suction hose is used, install a check-and-bleeder valve on the pump discharge and use a suction strainer instead of a foot valve on the suction hose intake. Two-inch suction hose is recommended: o If foot valves are used on the suction hose intake. o At high lift conditions (10 feet and higher). o When drafting long distances (over 20 feet horizontally). Tips Using Portable Pumps for Hose Lays 1. Follow operational procedures. A pump can be ruined in minutes if proper operational procedures are not followed. 2. Keep the pump as close to the water source elevation as possible as the maximum vertical lift (water source to the pump) for most pumps is about 22 feet at sea level. As lift is increased, pump performance decreases. 3. Do not use longer suction hose than necessary. 4. For good priming, remove any humps in the suction hose. 5. For consistent priming: With the pump not running, prime from the discharge side of the pump. With the pump running, prime from the suction side of the pump. 6

6. For higher pump output at low discharge pressures, use a check valve on the discharge side of the pump instead of a foot valve at the end of the suction hose. 7. Protect the pump from sucking sand, silt, or gravel by using a suction strainer and putting the suction hose intake in a pail or on a shovel. 8. Use a check-and-bleeder or shutoff valve on the discharge side of the pump near the pump when pumping uphill to prevent draining the hose lay (by backflow) when the pump is not running. Note: A check-and-bleeder valve operates automatically, whereas a shutoff valve must be operated manually. 9. Know your water source. Some natural sites may have other water-use demands. Water levels and flows can change on a daily basis. Check the pump site and available water levels before conducting continuous operations. 7

About the Author Dave Haston has been with the USDA Forest Service since 2003. Before coming to the center, he worked for 18 years in private industry in the areas of design engineering, manufacturing, and project management, the last 12 of which were spent designing respiratory protection equipment for structural firefighting and industrial applications. Dave is a licensed mechanical engineer in the State of California and is the holder of four patents for life support equipment. He represents the USDA Forest Service on three NFPA committees Fire Apparatus, Fire Hose, and Respiratory Protection Equipment. SDTDC wishes to acknowledge the following center employees for their contributions to this publication: Dan McKenzie, mechanical engineer (retired) Joe Fleming, mechanical engineering technician Paul Jun, mechanical engineer SDTDC wishes to thank the following individuals for their comments and technical review of this publication: Susan Zahn, Fuels Management Specialist, SDTDC Ralph Gonzales, Fire Program Leader, SDTDC Matt Cnudde, Emergency Management Specialist, National Interagency Fire Center, Boise, ID Doug Benton, USDA Forest Service, Pacific Northwest Regional Fire Cache Manager (R6) Justin Muhlhauser, Fire Cache Manager, State of Idaho SDTDC s national publications are available on the Internet at http://www.fs.fed.us/eng/pubs/. USDA Forest Service and U.S. Department of the Interior Bureau of Land Management employees also can view videos, CDs, and SDTDC s individual project pages on their internal computer network at http://fsweb.sdtdc.wo.fs.fed. us/. For additional information on this comparison study, contact Dave Haston at SDTDC. Phone: 909-599-1267 ext. 294; or by e-mail at dhaston@fs.fed.us. (Footnotes) 1 Although testing was conducted with a Mark 3 pump, similar results would have been obtained for the Mercedes Textiles Wick 375 pump. The Wick 375 is also USDA Forest Service-qualified and is interchangeable in the field with the Mark 3. The information contained in this publication has been developed for the guidance of employees of the Forest Service, U.S. Department of Agriculture, its contractors, and cooperating Federal and State agencies. The Forest Service assumes no responsibility for the interpretation or use of this information by other than its own employees. The use of trade, firm, or corporation names is for the information and convenience of the reader. Such use does not constitute an official evaluation, conclusion, recommendation, endorsement, or approval of any product or service to the exclusion of others that may be suitable. The U.S. Department of Agriculture (USDA) prohibits discrimination in all its programs and activities on the basis of race, color, national origin, age, disability, and where applicable, sex, marital status, familial status, parental status, religion, sexual orientation, genetic information, political beliefs, reprisal, or because all or part of an individual s income is derived from any public assistance program. (Not all prohibited bases apply to all programs.) Persons with disabilities who require alternative means for communication of program information (Braille, large print, audiotape, etc.) should contact USDA s TARGET Center at (202) 720-2600 (voice and TDD). To file a complaint of discrimination, write USDA, Director, Office of Civil Rights, 1400 Independence Avenue, S.W., Washington, D.C. 20250-9410, or call (800) 795-3272 (voice) or (202) 720-6382 (TDD). USDA is an equal opportunity provider and employer. 8