Electromagnetic Flow Monitor magphant

Similar documents
Electromagnetic Flow Monitor magphant

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Limit Switch liquiphant FTL 360 / FTL 361

Level Limit Switch soliphant FTM 930/931/932/ Z

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

ph-kompaktelektrodensystem sensopac CPA 320

Insertion magnetic inductive flowmeter

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Magnetic-inductive flow meter for hazardous areas

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

Conductivity Measurement CLM 280

Magnetic Inductive Flowmeter EP / UMF2 (B)

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Electromagnetic Flow Measuring System PROline promag 10 W

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

OPTIFLUX 6000 Technical Datasheet

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Soliphant II FTM30(D/S)/31(D/S)/32(D/S)

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

OPTIMASS 3000 Technical Datasheet

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

INSERTION flow sensor for continuous flow measurement

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Thermowell for temperature sensors omnigrad M TW 13

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

JUMO MIDAS S05 Pressure transmitter Type

Soliswitch FTE30. Technical Information

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Level Measurement Point level measurement - RF Capacitance switches

Pressure Transmitter JUMO dtrans p30 Type

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

Level limit switch Series RF 3000 Selection list

Addendum to the Catalog Diagnostic unit /DUE for function and wear monitoring of brakes BE.., BF.., BT..

Technical Information Proline Promag 10L

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Absolute pressure gauge with diaphragm

Thermowell for temperature sensors omnigrad M TW 11

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure transducer DMU 01K Compact version

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Series 3730 Electropneumatic Positioner Type

Conductivity Measuring Cells ConduMax W CLS 19

RTD Temperature Sensor omnigrad T -TR 470

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

97105 Inline. Ordering information. Technical data. Accessories See page 5

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

SITRANS F M flow sensors 711/A and 711/911E

Soliswitch FTE20. Technical Information. Point level switch for granular solids

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Dosimag. Technical Information. Electromagnetic volume flow measuring system for filling applications

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Paddle-wheel flow controller for On/Off control

Pressure transmitter for industrial applications Type MBS 4510

OPTIMASS 2000 Technical Datasheet

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

OPTISWITCH 6500 C Technical Datasheet

Sensor boxes SRBE Key features and product range overview

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Pressure transmitters for industrial applications Type MBS 4510

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Inductive conductivity meter

Digital ph transmitter

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

OPTISWITCH 6500 C Technical Datasheet

GA 24 Heavy-duty variable area flowmeter

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Electromagnetic flowmeters

Inductive conductivity meter

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

TIDALFLUX 2300 F Quick Start

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Differential pressure gauge with diaphragm

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Magnetic Inductive Flow

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

OPTIFLUX Electromagnetic Flow Sensor

FLOWX3 F3.60M.S Insertion Magmeter

Flow switches Series AD/VH

Electronic Limit Switch Type

Electromotoric Actuators

flow x3 flow monitoring

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

BATCHFLUX 5500 C Technical Datasheet

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

SITRANS P measuring instruments for pressure

Displacement Sensor. Model 8739, 8740, 8741

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Digital ph transmitter

Technical Information Omnigrad TST90, TET90

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Transcription:

Technical Information TI 036D/06/en No. 50078457 Electromagnetic Flow Monitor magphant Monitoring and measurement Flow monitoring with selectable limit values (relay output) Flow measurement via 4...20 ma current output Safe operation Reliable monitoring (4 ma) even with empty piping EMC tested according to IEC Measuring system self-monitoring Integrated testing to check correct functioning of the electronics Universal application One compact flow monitor for all applications Mounted in Steel piping from DN 25 Plastic piping from DN 15 Simple operation Switchpoint setting via rotary switch Local potentiometer setting of fullscale value Can be set-up before installation Endress +Hauser Nothing beats know-how

Magphant Measuring System Areas of application Flow information is often required to ensure a process is running correctly and that preset limit values are not exceeded. The Magphant flow monitor reliably provides the necessary information on flow in your piping. The electromagnetic principle used determines the flow velocity of the conductive liquid at the tip of the sensor. Cooling circuit of ventilation/exhaust systems, cooling air blowers, ventilators Flow measurement On/off switching according to flow rate Monitoring cooling systems Monitoring cooling systems Dry run protection for pumps Cooling control for pumps Application examples ti036y20 Areas of application: Process plant construction Chemical industry Energy production Water treatment Beverage industry Dairy industry Metal production and processing Farming and horticulture Applications: Dry run protection for pumps Flow monitoring On/off switching according to flowrate Control of cooling systems for pumps, turbines, compressors, heat exchangers Flow monitoring Monitoring pump function Monitoring coolant to bearings for turbines/generators in power plants Cooling circuits for transformers Status indication of valves in water distribution systems Blockage indication in pipes Filtration control Monitoring cleaning procedures Cooling systems in refrigeration plants Detecting breakdown of cooling systems for bearings and transmissions Control and monitoring of irrigation systems 2

Function Measuring principle In accordance with Faraday s law of electromagnetic induction, a voltage is induced in a conductor that is moved through a magnetic field. In the electromagnetic principle of measurement the flowing and electrically conductive fluid represents the moving conductor. The induced voltage is proportional to the flow velocity and is fed to the amplifier by a pair of electrodes. Microprocessor-controlled electronics, with a stable zero-point, convert the voltage into an analogue 4...20-mA output signal. Magnetic lines of force B Exciter coil Sensor L U e Magnetic core v Electrodes ti036y08 Design Measuring system design A construction overview of the Magphant measuring system is shown in the diagram below. Housing cover can be unscrewed. After opening the cover, operating and display elements as well as the terminal block are easily accessible. Cable gland PG 16 / M20 x 1.5 / 1 / 2 " NPT / G 1 / 2 " PVC cable gland PG 16 Signal cable Ground terminal Union nut M30 x 2 with clamp ring Sensor sleeve Power supply 20...30 V DC Electronics housing Weld stub DN 25 Weld stub DN 40 (mounting length indicated) Union nut and adapter for Magphant installation in plastic piping Electrodes Measuring system design ti036y04 3

Mounting Instructions Orientation in the piping The Magphant is best mounted in vertical piping. If the piping runs horizontally, the Magphant is to be mounted to the side. This mounting procedure ensures that the electrodes are always immersed in flowing fluid. Preferred mounting orientation Non-recommended mounting orientation Possible air bubbles 45 Caution! Never weld the weld stub to the pipe with the Magphant in place. Recommended inlet and outlet pipe sections: 5...10 x DN Possible build-up of solids ti036y05 Mounting in steel piping Weld stub The Magphant is mounted using the weld stub supplied. Two different versions are available, depending on nominal diameter: Weld stub for DN 25 For DN 25 piping, the weld stub has the appropriate radius to match the diameter. Opening in the piping: = 23 mm Place the weld stub on the opening and weld it at right angles to the axis of the piping. ti036y07 Weld stub for DN 40 For DN 40...300 piping, the weld stub has a graduated scale to ensure that the stub can be correctly positioned for mounting. Opening in the piping: = 30 mm Insert the weld stub into the opening, with the marking (according to the nominal diameter) flush against the outer wall of the piping and weld it at right angles to the axis of the piping. ti036y11 Mounting in plastic piping Adapter piece for plastic piping For mounting in plastic piping, Magphant is delivered with an adapter piece and a plastic union nut, with which Magphant can be mounted in a T-fitting (DN 15...DN 50) or a plastic weld stub ( DN 65). The T-fittings or plastic weld stubs can be obtained from Georg Fischer (+GF+). ti036y19 4

The T-fittings are available in PVC-U, PP and PVDF. The weld stubs are available in PVC-U, PP and PE and must be adapted according to the diagram opposite and the given diameter. The length L can be calculated from the following formula: L = 40 - S - E S = wall thickness of the pipe E = can be taken from the table below: Pipe outside diameter 65 75 110 125 140 160 200 225 250 280 315 355 400 450 500 630 E 6.9 8.3 11.4 14.4 17.7 17.7 12.0 5.0 5.0 5.0 The total length (68 mm) must also be observed. Hole in the pipe: Ø = 40 mm ti036y21 Operational safety Comprehensive self-monitoring of the measuring system assures high safety. Any error messages that occur (process errors, instrument system errors) are immediately signalled via the current and relay outputs. The Magphant measuring system fulfils all general requirements for electromagnetic compatibility (EMC) according to CE (EN 50081-1-2 and EN 50082-1-2). Protection type IP 66 is standard (DIN 40050). Magphant fulfils the EU directives for low-voltage and EMC and bears the CE mark. Electrical Connection Terminal block Fuse 160 ma slow blow Current output 4...20 ma Load R L = 750 Ω max. Relay output Power supply 20...30 V DC 75 V DC / 0.5 A 60 V AC / 0.4 A Current output The Magphant has an analogue output which is proportional to the flow. The 4...20-mA output signal can be used for other systems such as a PLCs, controllers, etc. Relay output The Magphant also has a dry changeover contact which is especially suitable for monitoring purposes. Exceeding the range of set limit values (min./max. fail-safe) is indicated via this relay output. Power supply cable Ground terminals for cable shields Signal cable Warning! Do not install, wire up or dismantle the instrument when the power supply is switched on. Note connection polarity and operating voltage. ti036y02 5

Operation Setting limit value as percentage of the set full-scale value Red LED for limit value or error indication Test mode Green LED for full-scale setting Potentiometer for setting the full-scale Time constant, current output and relay latch time Relay function, Min./max. fail-safe de-energising of relay on error and limit value or on limit value only Operating and display surfaces Operator settings can be noted on the operating and display surfaces. ti036y09 Technical Data Dimensions and weight Nominal Diameter H for mounting in steel piping H for mounting in plastic piping Note! Dimensions of the weld stub see page 4 25 40 50 80 100 150 200 250 300 237.0 234.0 234.0 230.0 227.0 220.5 214.5 207.5 201.5 see page 4 and 5 Dimensions and weight ti036y01 Weight: 1.2 kg 6

Power supply Power consumption Outputs 24 V DC (20...30 V DC) <2.5 W Current output 4...20 ma, active The measuring system can measure flow in both directions, i.e. bidirectionally. The current output is always positive. The relay responds to both flow directions. Relay output Potential-free change-over contact 60 V AC/0.4 A 75 V DC/0.5 A Ambient temperature -20... Process temperature -20...120 C (weld stub 1.4435 with clamp ring) -20...100 C (weld stub St.37 with clamp ring and NBR gasket) Pressure 16 bar at 25 C; 10 bar at 120 C Full scale value Accuracy Reproducibility Conductivity 1...5 m/s (infinitely variable) ±2% o.r. at measuring electrode with local calibration at flow velocities >1 m/s ±2% o.r. 20 µs/cm Interference immunity acc. to CE EN 50081-1-2 und EN 50082-1-2 Protection type IP 66 / NEMA 4X / Type 4X Materials Sensor Sensor tip: PVDF, Viton O-ring Electrodes: 1.4435/316L Sensor sleeve: 1.4435/316L with 1.4571/316Ti clamp ring for 1.4435/316L weld stub 1.4435/316L with clamp ring and NBR gasket for St.37/A570 weld stub Housing Weld stub (for steel piping) Adapter piece (for plastic piping) Plastic union nut (for plastic piping) Die-cast aluminium, epoxy powder coated 1.4435/316L St.37/A570 1.4435/316L (with 2 Viton O-rings) PVC Approvals CENELEC: VDE 0165 manufacturers certificate for Zone 2 SEV: Ex nv/w IIC T4...T6, Ex Zone 2 FM: NI Cl I Div. 2 Groups ABCD; DIP/II, III/1/EFG. NEMA 4X CSA: Class I Div. 2, Groups A, B, C and D; Class II E, F and G, Class III; Type 4X Thermal data and temperature classes for Ex Zone 2 IEC 758 T fluid (see above) T ambient T1 T2 T3 T4 T5 T6 100 C/120 C 100 C/120 C 100 C/120 C 100 C/120 C 95 C/ 95 C 80 C/ 80 C 40 C 7

Product Structure Version / Sensor gasket A1 Union nut for DN 25...2000 (1"...80") (only for weld on nipple) A2 For plastic pipes DN 15...1000 ( 1 / 2 "...40") (only for adapter for plastic pipes) 99 other Mounting Nipples / Sensor gasket 1 Weld on nipple DN 25, St.37 / A570 compression ferrule with NBR gasket 2 Weld on nipple DN 40...2000, St.37 / A570 compression ferrule with NBR gasket 3 Weld on nipple DN 25, 1.4435 / 316L compression ferrule 1.4571 / 316Ti 4 Weld on nipple DN 40...2000, 1.4435 / 316L compression ferrule 1.4571 / 316Ti 5 Adapter for plastic pipes, 1.4435 / 316L compression ferrule NBR gasket 9 other Cable glands A PG16 cable glands B M20x1.5 threads for cable glands C 1 / 2 " NPT threads for cable glands D G 1 / 2 " threads for cable glands 9 other Approvals 1 Version for non-hazardous areas 2 VDE 0165 Certificate of Conformity 3 SEV, Ex Zone 2, Ex n approval 4 FM, NI Cl I Div. 2 Gp ABCD 5 CSA, NI Cl I Div. 2 Gp ABCD 9 other Options A Standard version 9 other DTI 200 - Order code Supplementary Documentation Special Documentation Magphant (SD 016D/06/e) Operating Manual Magphant (BA 025D/06/e) Subject to modification Endress+Hauser GmbH+Co. Instruments International P.O. Box 2222 D-79574 Weil am Rhein Germany Tel. (07621) 975-02 Tx 773926 Fax (07621) 975345 08.93 Endress +Hauser Nothing beats know-how TI 036D/06/en/06.97 CV4.2