Cradle Mounted Key Interlock Guide Frame Accessory

Similar documents
Instruction sheet WARNING. October, 2014

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

Installation Instructions For Motor Control Center (MCC) Units

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

Vacuum Circuit Breaker (Vehicle)

SIGNAL WORDS QUALIFIED PERSON

Instruction and Installation Guide

Vacuum Circuit Breakers (Vehicle)

Instruction Booklet IB E. Contents

Factory Authorized Mechanism Enhancement (FAME)

SIEMENS. Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide E87010-A0151-T003-A1-49EC. August, 2012

TYPE AST. Grounding Switch. ALL Ratings INSTALLATION & INSTRUCTION MANUAL

RGZESDI Inverter Duty AC Induction Motors

Vacuum Circuit Breakers (Vehicle)

Effective June 2016 New Issue

Vacuum Circuit Breakers (Vehicle) Type MSV 5kV. Instructions Installation Operation Maintenance SGIM-9988

SecoVac * Ground & Test Device

Operation and Maintenance Manual

Vacuum Circuit Breakers (Vehicle) Type FSV 5kV to 15kV. Instructions Installation Operation Maintenance SGIM-9968

Vacuum Circuit Breakers (Vehicle)

Vacuum Circuit Breakers (Vehicle) Type HKR 7.5kV to 15kV. Instructions Installation Operation Maintenance SGIM-9928C

Flush Mount AIN ALPHA Meters. General. Hardware Kit

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Vacuum Circuit Breakers (Vehicle)

Mechanism Operated Contacts

CCP2-FLR1-21_ flange-rod operating mechanism

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Remote Operator Accionamiento a distancia Commande motorisée

Vacuum Circuit Breakers (Vehicle)

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

SIMOREG CM. Application CM for more than three thyristors in parallel. 6RA70 Series. Microprocessor-Based Converters for Variable-Speed DC Drives

Universal Retrofit System Installation Instructions Revised:

n Ilation instructions Load Center Transfer TMOperator

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

Vacuum Circuit Breakers (Vehicle)

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Installation Sheet January, 2016 Supersedes February, 2013

Low Voltage WavePro TM and EntelliGuard TM Circuit Breakers Remote Racking Operator

IB PowlVac ITE-HK Remote Racking Device

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

Power Break Circuit Breakers

Installation Sheet January, 2016 Supersedes June 2013

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Effective November 2016 Supersedes September 1998 (S )

O & M Manual for the EATON Generator Ready Loadcenter

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

EntelliGuard Power Circuit Breaker Accessories. Network Interlock for Ampere Circuit Breakers. Introduction. Operation

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

SIMOREG SIMOREG DC-MASTER. 6RA70 Series

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

High-voltage primary bushings installation instructions

Magnum Breaker Remote Racking Device (MRR1000)

Gen 2 Portal Gear Hubs for Polaris Ranger Crew 570/900

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

Effective May 2017 Supersedes December 2004 (S )

Spectra Series Power Panelboards. General. Installation. Bolt-On Circuit Breaker Kits. DEH059 Installation Instructions

Effective March 2015 Supersedes S August 2012

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers

Instructions for installation, operation, and maintenance of medium voltage VC-W MR2 (integral racking)

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

DEMON CARBURETOR MANUAL CHOKE KIT #421441

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

H- or J-Frame Main Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

Instruction manual. Types GMSG and GMSG-GCB 5 kv to 15 kv vacuum circuit breakers.

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Toyota Hilux / fortuner BATTERY BRACKET

GE CONSUMER & INDUSTRIAL

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Type DTU De-energized Tap Changer Application, Installation & Selection Guide. IL A Instruction Leaflet Page 1 September, 2003

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

I N S TA L L AT I O N G U I D E

I N S TA L L AT I O N G U I D E

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

SIEMENS. Combination Starter Enclosure Kit Classes 49EC17 & 49EC18 Instruction Guide E87010-A0151-T003-A1-49EC. September, 2017

Two-way cable interlock kit for Magnum drawout circuit breakers

Two-way cable interlock kit for Magnum fixed circuit breakers

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

CITY AND COUNTY OF SAN FRANCISCO. SPECIFICATION FOR Copier Lease Agreement Last revision 03/03/2016

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

Type 38-3AH3 38 kv vacuum circuit breaker instruction manual. Installation operation maintenance E50001-F710-A238-V1-4A00. Answers for energy.

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

Transcription:

s Cradle Mounted Key Interlock Guide Frame Accessory Cat. No.: WLDLKRK, WLDLSUP, WLDLDKRK, WLDLDSUP, WLDLPR, WLDLDPR For Use With: Circuit Breaker Adapters WLG _ 3 Installation Instructions Instruction No.: 11-C-9019-01 DANGER Will cause death, serious injury. Turn off and lock out all power supplying this device before working on this device. Replace all covers before power supplying this device is turned on. WARNING Only qualified personnel should work on this equipment, after becoming thoroughly familiar with all warnings, safety notices, and maintenance procedures contained herein and on the devices. See the Operator s Manual for the definition of qualified personnel. The successful and safe operation of this equipment is dependent on proper handling, installation, operation, and maintenance. Only s authorized repair or replacement parts shall be used All installation instructions must be strictly followed.

NOTICE These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the Purchaser s purposes, the matter should be referred to the local Siemens Sales Office. The contents of this instruction manual shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligations of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements contained herein do not create new warranties or modify the existing warranty. Designations in this documentation can be trade-marks. Use by third parties for their own purposes violates the owner's rights.

CRADLE MOUNTED KEY LOCKING DEVICE This special function for draw-out circuit breakers prevents closing of any circuit breaker within this circuit breaker compartment unless the key(s) are installed and engaged. To activate the lock, the circuit breaker must be open. If the circuit breaker is closed, the locking device is blocked. The block is only effective if the key is withdrawn. The key can only be removed when the circuit breaker is in the "OPEN" position. 1 of 8

KEY INTERLOCK INSTALLATION KIT CONTENTS The following parts have are required to complete this installation. 1. Preassembled key intelock 9. Extension (FS III Only) 17. Spacer (FS III Only) 2. Key Lock 10. Pan head M4 screw (FS III Only) 18. Pan head screw M4 3. Spacer 11. Lock washer (FS III Only) 19. Countersunk Head Screw M6x16 4. Lever 12. Nut M4 (FS III Only) 20. Belleville Washer 5. Socket head M4 screw 13. Ramp Extension (FS III Only) 21. Nut M6 6. Bolt 14. Countersunk head screw M4 (FSI III) 22. Countersunk screw TAPTITE M4x10 7. 5mm Washer 15. Plastic Slider 23. Pan head screw TAPTITE M4x10 8. Bolt Clip 16. Small Attachment Angle 2 of 8

ATTACHING THE KEY LOCKS TO KEY LOCK PROVISION The method in which the locking unit is installed is the same whether the unit consists of one lock or two locks. Secure the key interlock(s) to the key lock provision, passing the key lock through the collar and lever, and securing with the provided #6-32 screws. MODIFICATION TO THE LEFT HAND SLIDE RAIL & CRADLE FLOOR The key interlock provision is secured to both the left hand slide rail and the cradle floor. 3 of 8

4 of 8

INSTALLING THE INTERLOCK BASE The interlock base should next be attached the the cradle floor. Draw the interlock out until it is fully extended. Position the interlock above the holes drilled in the cradle floor in the previous step, and attach with provided screws (with part a being item 22 M4x10 TAPTITE, and part b being the item 23 M4x10 pan head TAPTITE). ADJUSTING THE KEY INTERLOCK SLIDER The slider assembly must be attached to the left hand slide rail. The spacer (item 17) should only be used with Frame Size III cradles. 5 of 8

Adjust the slider for the correct cradle configuration per the following figure. For Frame Size III cradles, the extension bar must be mounted as shown. 6 of 8

DRILL HOLE INTO CUBICLE DOOR (1) (2) (5) (4) (3) (1) Lower edge of door cutout (2) Center of front panel (3) Circuit breaker or guide frame mounting surface (4) Hole for first key cylinder (5) Hole for second key cylinder (only if provided) KNOCK OUT FIELDS ON THE FRONT BREAKER PANEL 2 1 1 Knock out the fields on the front panel using suitable supports 2 Deburr the edges 7 of 8

ORDER NO. Key Locking device in OPEN position Manufacturer Catalog No. Single lock KIRK WLDLKRK 2 Double lock SUPERIOR KIRK WLDLSUP WLDLDKRK SUPERIOR WLDLDSUP 8 of 8