LHS-001 QUICKSTART GUIDE. 650 Watt Tungsten Open Face Light (Lightstar)

Similar documents
QUICKSTART GUIDE CHECKED BY

QUICKSTART GUIDE MW8. Mylo Daylight Half x 1 LED Light MB8. Mylo Bi-Color Half x 1 LED Light ikan Corporation. All rights Reserved

shadow focus floodlight SFS-300 INSTRUCTIONS

User Guide for Logo Projector

The POWER In PRESENTATION PRODUCTS

Operating instructions Bedienungsanleitung Mode d emploi

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

LED GEL MOUNTED FRAME

ALU-29CF Portable Light NSN:

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

ULTRA QUARTZ FOLLOWSPOT USER MANUAL

Swing Arm Magnifying Lamp

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Fluorescent Ring Light with Dimmer INSTRUCTIONS

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

AFL FLOODLIGHT SERIES

REMBRANDT 2,5/4 kw Dual Power Daylight. Mod. 2532

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

300 Watt LED Pole Top Light Fixture VAC W Metal Halide Equivalent - Slip Fit Yoke

LED IP65 Flood Light GI-FL10. Trusted by more than 1500 American companies! DESCRIPTION COMPLIANCE FEATURES. Page 1 of 5

4000 SYSTEM OPERATING MANUAL

WAVELIGHT -2 USER INSTRUCTIONS. Description:

1000W High Intensity LED Crane Light - 110,000 Lumens V AC - Stainless Steel Bracket

1.2.5 kw POSITION POSITION

The POWER In PRESENTATION PRODUCTS

B4A Instruction Manual

Image Pro. Create eye-catching holiday displays or project personalized images. Image projection system

USER MANUAL LUX-LD30W LED MOVING HEAD

WORKLIGHT LUZ DE TRABALHO LED LED WORKLIGHT MANUAL DE INSTRUÇÕES INSTRUCTION MANUAL FWL-1003 EN PT. tl fx.

General Installation Manual for American Gas Lamp Works Gas & Electric Lamps, Torches & Posts

Installation/Operating Instructions

Mania EF1 user manual

AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

1000 Watt High Intensity LED Light - 110,000 Lumens V AC - High Mast / Stadium Lighting

INSTRUCTION MANUAL. All PrimeTime Studio Lights are equipped with advanced reflector technology.

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Parts Manual Rev. A RZT48 /

Microscope light manual

Navigator ORDERCODE 40410

Measurements are expressed in millimeters.

FOLLOW SPOTLIGHT INSTRUCTION MANUAL. Equipment Type Rev. April 2007

Parts Manual Rev. B RZT48 /

Operator's manual. TruTool F 140 (1A1) english

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

Instructions. Warnings 2 Setup & Lamp Installation 3 Rear Panel 3 Mounting 4 Accessories 4-6 Warranty, Problems, Repairs & Information 7

Parts Manual Rev. A RZT54 /

The Miniature LED Fresnel 20W - CRI>96

INSTALLATION INSTRUCTION MANUAL

IMPORTANT SAFETY INSTRUCTIONS

Ego 01 Ego 02 Ego 03 Logo Projector user manual

BL7000 SYSTEM OPERATING MANUAL

HBC-20 - LED HIGH BAY

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

Industrial flue gas probes. Instruction manual

25W Explosion Proof LED Light VAC or 11-25V AC/DC - Pedestal Mount - 100' Cord w/ EPP Cap

Assembly & Operator s Manual

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

LED Specialty Lighting COKE OVEN EQUIPMENT

OCTA FLUORESCENT 7 SOCKET FIXTURE

Explosion Proof LED Drop Light / Trouble Light -10 Watt LED - 50 Foot SOOW Cord

WF-400S/FF Kit WF-400S/FG Kit WF-400S/FH Kit WF-400S/FI Kit WF-400S/F2 Kit

3000 Watt Pneumatic Light Tower - Extends to 18 Feet - Three 1000W Metal Halide Lamps

400W High Intensity LED Light - 54,000 Lumens V AC - Bar Clamp/Trunnion Mount - Outdoor

Mania DC3 user manual

Lights CONTINUED TURN SIGNAL/SIDE MARKER LIGHT HEADLIGHT PARKING LIGHT. Maintenance 237

LED Cab Light Upgrade Kit for CAT Challenger 75E Tractors - (10) LEDEQ-3X2-CPR

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

Light/Energy. Halogen floodlight. Fire Brigade 500 W halogen floodlight. Fire brigade 1000 W halogen floodlight. Quality since 1903

Detroit Speed, Inc. Rear Coilover Tower Brace Kit Camaro P/N:

Predator Medium Floodlight Wet Location

High Intensity Colored LED Light - 90 Watts - 30 LEDs - Red, Amber, Green, Blue

Before installing your Roush Performance Product(s), read through the entire installation procedure and check to make sure all items are present.

HyperFlex 12G.

I With Reflector 104-R 118-R. With Switch with Receptacle

Installation and Operation Manual

LIONEL Rev. 2/ Generator Car

2. Description of Standard NUV Lightsource (350nm-450nm) 3 3. Description of Deep UV (220nm-280nm) and Mid UV (280nm-310nm) Lightsource Systems 3

Bulb Replacement REPLACING BULBS

ConstantColor CMH MR16

ASTROSCAN (8 2 ) 2.5 HMI 1200 ENGLISH INSTRUCTIONS MANUAL SAFETY INFORMATION ENGLISH

OLYMPIAN MODEL 740 Operation and Service Manual

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

Lights TURN SIGNAL/PARKING LIGHT HIGH BEAM HEADLIGHT LOW BEAM HEADLIGHT. Maintenance

Sectional and Tilting Door Opener

I1 7.5 Pre-Lit Clear Christmas Tree

INSTALLATION INSTRUCTION

Installation Instructions

1000 DE BOSS. Installation & Operating Instructions COMMERCIAL FIXTURE READ THESE INSTRUCTIONS BEFORE FIRING UP YOUR BALLAST

Installation/Operating Instructions

Gavita HortiStar 600 SE EU

Compact LED profile with zoom

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

STRONG 575 Follow Spotlight

Bulb Renewal TOP ACCESS COVER

Series 1 Examination Lamp. Series 2 Examination- and Reading Lamp. Series 3 Reading Lamp. Series 4 Reading Lamp. Series 5 Examination Lamp

300 Watt LED High Bay Light Fixture VAC W Metal Halide Equivalent - 29,580 Lumens

Before replacing LED light ensure the unit is switched off, when you want to

Installation Instructions / Warranty

Transcription:

LHS-001 QUICKSTART GUIDE 650 Watt Tungsten Open Face Light (Lightstar) What s Included 1 x 650 Watt Lighting Fixture 1 x Barn Doors 1 x Yoke 1 x 6 Ft Power Cable 1 x Safety Screen CHECKED BY www.ikancorp.com 713.272.8822 support@ikancorp.com 2016 ikan Corporation. All rights Reserved

Getting to know your LIGHTSTAR Light The Lightstar LHS-001 (650 Watt) fixtures are intended for professional applications, and are only to be operated by qualified persons. Please read the following operating instructions very carefully before using this fixture. They contain important information on the operation of Lightstar lighting. For your own safety, please follow all safety instructions and warnings. Please follow the operating instructions of the lamp manufacturers. Please keep these operating instructions for you and subsequent users to reference in the future. CAUTION: These fixtures use high voltage, before replacing the lamp; disconnect the fixture from its power supply. WARNING! Lamp may be hot! Allow the lamp to cool down sufficiently before replacing it. Do not switch on the Fixture without a lamp inserted. Do not switch on the fixture without a Fresnel lens, safety mesh and reflector in place. WARNING! The housing of the fixture can achieve very high temperatures. Do not cover any ventilation slots. Always keep the mains cables away from the hot housing. A risk of overheating or fire can occur if misused. Do not overtax the fixture cables for transport or suspension of fixture. Always remove the lamp from the fixture for transport. Do not operate the fixture if it shows any visible damage. Mounting the Fixture Loosen the thumb screw on the yoke. Bring the fixture to the desired position. Tighten thumb screws until it locks in place. Check to ensure the fixture is securely fastened. If the fixture is being used in a hanging position, be sure to secure the fixture with a safety cable from the mounting pipe or truss. Accessories, not secured with a safety rope must be secured with a safety cable as well. The carrying capacity of the safety rope must be rated at a minimum of 10 times the weight of the fixture system including accessories. Stands must be set up in a stable position and capable of carrying the weight of the fixture including accessories and cables. Getting the Fixture Operational USE of the Fixture The lamp can be turned on by the inline switch on the light. The beam angle can be adjusted by turning the knob clockwise to change light coverage. Inserting the Lamp Before replacing the lamp, the fixture must be disconnected from the power supply. Before inserting, visually check the lamp for functionality. Damaged lamps must not be operated. Ensure the lamp is firmly fastened in its socket and the lamp must match the fixtures voltage. Connect the lamp head connector to the power source, and put the cable switch to the ON position. For the LHS-001 (650W) Light, you will remove the barn doors and the safety screen from the front of the housing. Turn the focus knob to move the lamp holder to the extended position. Push one side of the lamp into the holding pin. It is spring-loaded, so the lamp should insert into one side then insert into the other side of the fixture. Be careful not to over-exert the bulb as it is fragile and may break.

Inserting Accessories Inserting and exchanging accessories must be carried out from a stable position. Make sure all accessories being used with the LHS-001 are securely locked. WARNING! Do NOT operate the fixture with closed barn doors! The risk of overheating can occur. Internal Care Instructions Please clean the reflector and lens regularly with a customary glass cleaning agent. Please check that the reflector shows no kind of corrosion or damage. Keep the contact surfaces of the electrical connections and lamp holder clean. Lightstar Disclaimer The manufacturer disclaims liability for any damage to persons or property caused by inappropriate or misuse of the fixture. Damage of this kind is responsibility of the operator. Periodic Fixture Inspection 1. The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 working hours or at least once a year. This frequency may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar spare parts. 2. The lamp should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged otherwise explosion might occur. Defer to instruction provided by the lamp manufacture. 3. Always check the safety shield before every use. 4. All high-voltage components (ex: voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a year). 5. Outer door hinges and latching system must be checked every 250 working hours to insure proper seating of the safety shield. This will allow inspections of accessories and the holding clamps. 6. The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it becomes either cracked or broken. It is essential for the performance of the fixture.

Specifications & Photometrics LHS-001 Photometrics No Lens Distance 2.5m Beam Angle Luminance 1236 Spot 36 Beam Diameter 3.2 M Flood Optional Accessories LHS-001 Specs Head Type 3200K Rating 120V AC, 50-60 Hz Light Source 1-650 Watt Bulb Power Supply 6 Ft Power Cable Lens No Lens Beam Angle 36-70 Cooling System Air Cooled Yoke Cast-Aluminum 1 1/8" Pin Fixture Size 8 x 10 x 7 In. Fixture Weight 2 lbs Build Material Aluminum Shipping Dimensions 11 x 9 x 9 In. Shipping Weight 9 lbs Luminance 445 Beam Diameter 7.0 M Some other products that work well with the LHS-001 available from Ikan include: 70 HD-STND KCP-703 ROLLR-STND10 SW-04 Heavy Duty Light Stand Stage Clamp w/ 16mm Stud 2-Stage Roller Stand 10ft 6in Safety Wire

Learn More More dynamic information at official website: www.ikancorp.com Support Contact email: support@ikancorp.com CONDITIONS OF WARRANTY SERVICE Free service for one year from the day of purchase if the problem is caused by manufacturing errors. The components and maintenance service fee will be charged if the warranty period is expired. Free Service will not be Provided in the Following Situations:(*Even if the product is still within the warranty period.) Damage caused by abuse or misuse, dismantling, or changes to the product not made by the company. Damage caused by natural disaster, abnormal voltage, and environmental factors, etc. 2016 ikan Corporation. All rights reserved