Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Similar documents
WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

GDD - Supply Grille. Halton GDD. Supply Grille

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

TBV - Terminal Unit. Halton TBV. Terminal Unit

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

DAC - Conical Diffuser. Halton DAC. Conical diffuser

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

ULA - Valve. Halton ULA. Valve

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

Halton PRL Plenum for grilles

Aircell Polymer Range

HIGH CAPACITY LINEAR SLOT DUFFUSERS

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

series Linear grilles

Compact Grille Model KG

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

REK, LEK, ROK and LOK

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

REK, LEK, ROK AND LOK

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

SDV Vane Swirl Diffusers

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Ventilation grilles for installation into walls, sills or rectangular

LINEAR DIFFUSERS AND BAR GRILLES

Ventilation grille Model AL

Air diffuser system Model AUDIX -AW

CornerAir. CornerAir. Active chilled beam

Ventilation grilles for installation into walls, sills or rectangular

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

Ceiling swirl diffusers

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

DRUM SLOT DIFFUSER TYPE: RT350

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Ventilation grilles for installation into walls, sills or rectangular

Ceiling diffuser 4DE

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

Slot diffusers, Round duct diffusers. IMP Klima

ADJUSTABLE SLOT DIFFUSER TYPE: SE800

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Ventilation grilles for installation into walls, sills or rectangular

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

Ceiling diffuser 4DF

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

Ceiling impulse diffuser Model PIL

LINEAR SLOT DUFFUSERS

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Ceiling swirl diffusers

Linear Slot Diffusers Model Slot 20 & Model Slot 25

ADJUSTABLE PERFORATED AIR SUPPLY DIFFUSER TYPE: DC560S

ILO, OLO, OLE and OLOi

series KLR Linear slot diffusers

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

USS - External Louvre. Halton USS. External Louvre

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

Grilles Linear Grilles

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Wall and Ceiling Grille

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

Ceiling swirl diffusers with perforated face plate

Ceiling Slot Diffuser DSC

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

FlowBar High Capacity Slot Diffuser

ceiling swirl diffuser Model DQJA / DQJR

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

Slot diffusers for ceiling installation

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser

Grilles Linear Grilles

ceiling swirl diffuser DQJ

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Halton Rex 600 RE6 - Adaptable active chilled beam

Small Format Circular Diffusers. Small format circular diffuse

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

Particle Filter Box Model FKF

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Transcription:

Halton AWE/AWU Universal Grille Horizontal air supply, suitable also for exhaust Fixed front vanes, stable throw pattern with vertical 15 deflection: AWE, no deflection: AWU Adjustable rear vanes for horizontal deflection of the air jet Aluminium construction with elegant outlook Detachable grille enables cleaning of the grille and ductwork MATERIAL AND FINISHING PART MATERIAL FINISHING Continuous grilles available with modular construction Accessories Airflow adjustment damper Plenum options with measurement and adjustment functions Installation frame NOTE Frame Aluminium Anodised, Polyester-painted, White RAL 9010 50% gloss, Mill finished Vanes Aluminium Anodised, Polyester-painted, White RAL 9010 50% gloss, Mill finished Installation frame Plenum box / spigot Galvanised steel Galvanised steel Special colours available Epoxy-painting (100 %) available Special colours available Epoxy-painting (100 %) available ACCESSORIES ACCESSORY CODE DESCRIPTION Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise Plenum BDR Plenum for duct connection (with or without attenuation material) Airflow measurement and adjustment unit MSM For supply installation Sound attenuation IN Mineral wool for the BDR plenum box. Polyester fiber for the PRI plenum box. Flow adjustment damper OD Aluminium opposite blade damper~for airflow adjustment Installation frame IF For installation without plenum Concealed screw fastening CC For installation with BDR plenum or IF frame 1

18 L2 5 18 H1 H2 48 AWE L1 DIMENSIONS NS L1 L2 H1 H2 AWU Function Supply air is supplied with vertical 15 angle deflection and with horizontal deflection (rear vanes) through the vanes into the space, mixing with room air in front of the grille. The flow pattern is adjusted by changing the angle of the adjustable rear vanes. Wall installation for horizontal supply or ceiling installation for vertical supply. In wall installations, the recommended distance from the ceiling is 200 mm, when the supply air is directed to the ceiling.(awe) The grille can also be used as an exhaust unit.(awu) 200x50 212 176 62 26 200x100 212 176 112 76 300x100 312 276 112 76 400x100 412 376 112 76 500x100 512 476 112 76 600x100 612 576 112 76 800x100 812 776 112 76 1000x100 1012 976 112 76 600x150 612 576 162 126 800x150 812 776 162 126 1000x150 1012 976 162 126 1200x150 1212 1176 162 126 1500x150 1512 1476 162 126 600x200 612 576 212 176 800x200 812 776 212 176 1000x200 1012 976 212 176 1200x200 1212 1176 212 176 1500x200 1512 1476 212 176 With flow control damper OD total depth = 48 mm + 45 mm. Special dimensions In addition to standard sizes, other sizes can be specially ordered. The maximum size is 1500x500 mm (LxH). It is possible to have a continuous grille of modular design when the installation length is greater than 1500 mm. The maximum total length is 20 m. 2

Installation frame (IF) PRI balancing plenum BDR plenum box Installation Concealed screw fastening (option) The grille is connected to the circular duct using either a PRI balancing plenum or a BDR plenum or alternatively directly to the rectangular duct using the IF installation frame. Clips fastening (standard) The grilles are supplied with clips fastening as standard. Clips fastening is used with PRI, BDR and IF. Concealed screw fastening is possible when the grille is installed with an installation frame (IF) or a BDR plenum, though not with a PRI balancing plenum. Holes for screws are provided in the BDR. For ceiling installation concealed screw fastening is recommended. Visible screw fastening is not possible due to the reduced width of the frame (18 mm). Size of the installation hole is LxH when installation frame is used, and (L-5)x(H-5) without installation frame. 3

K factor for installations with different safety distances (D= duct diameter) ØD PRI/S >8xD min 3xD Adjustment In order to enable airflow adjustment and measurement of airflow rate it is recommended that you connect the diffuser to the BDR plenum or PRI balancing plenum equipped with the MSM module. The supply flow rate is determined by using the MSM measurement and adjustment module. Detach the grille and pass the tubes and control spindle through the grille. Measure the differential pressure using a manometer. The flow rate is calculated using the formula below. 125 200x100 10.1 12.6 160 300x100 17.0 21.7 160 400x100 17.0 21.7 200 500x100 27.7 33.9 200 300x150 27.8 33.9 250 400x150 47.2 55.5 250 500x150 46.2 50.1 250 600x150 45.8 51.1 315 800x150 80.8 83.3 250 400x200 51.2 55.5 315 500x200 92.9 83.3 315 600x200 82.7 93.1 315 800x200 79.3 83.3 BDR >6xD min 3xD 100 6 7 125 10 12 160 19 22 200 28 32 250 49 51 315 77 83 q v = k * p m Adjust the airflow rate by rotating the control spindle until the desired setting is achieved. Lock the damper position with a screw. Replace the tubes and spindle in the plenum and replace the grille. Airflow adjustment damper OD The airflow rate is adjusted by turning the damper blades behind the grille using a screwdriver. The measurement is carried out when grille is installed. 4

Pressure drop, throw pattern and sound data AWE or AWU, wall installation at a distance of 200 mm from the ceiling (with Coanda effect) 200x50, 200x100, 300x100, 400x100 500x100, 600x100, 800x100, 600x200 1000x100, 800x150, 1000x150, 800x200, 1000x200 1200x150, 1500x150, 1200x2000, 1500x200 Note : When there is no coanda effect (installation greater than 200 mm from ceiling) the throw pattern must be multiplied by 0.7. For exhaust use, adjust supply data by adding + 5 db(a) and DPs= DPs x 1.2. 5

Sound power level with OD damper Use of an OD opposite blade damper, will result in increased pressure loss. The resulting increase in sound level is computed from the selection chart value and the formula below: LpA = DLp + LpA Kp= Adjusted pressure drop Pressure drop in selection chart Example : ALE-1000x150 + OD/ALE qv = 300 l/s LpA = 31 db(a) without damper OD/ALE DPs= 50 Pa (desired pressure drop) Kp = 50/11 = 4.5 LpA = 31 + 14 = 45 db(a) Throw length correction factor When the throw length is adjusted with the rear vanes, the actual throw length is obtained by multiplying the value obtained from the selection chart by the correction coefficient K1. L0.2 (a) = K1 x L0.2 The correction coefficient K1 is the average for the various grille sizes. Pressure drop correction factor Angle between vanes When the throw length is adjusted with the rear vanes, the actual pressure drop is obtained by multiplying the value obtained from the selection chart by the correction coefficient K2. DPs (a) = K2 x DPs The sound level increases when pressure drop is increased. The correction coefficient K2 is the average for the various grille sizes. Angle between vanes 6

SOUND LEVEL DATA, SUPPLY AWE-AWU qv DPst DPtot F (Hz) LpA NR NC (l/s) (m 3 /h) (Pa) (Pa) 125 250 500 1000 2000 4000 8000 [db(a)] 200x50 17 61 16 18 34 33 27 21 13 7 9 25 19 17 21 76 25 28 39 38 32 26 18 12 14 30 24 23 26 94 38 42 44 43 37 31 23 17 19 35 29 28 33 119 58 65 49 48 42 36 28 22 24 40 35 33 200x100 35 126 11 13 34 33 27 21 13 7 9 25 19 17 44 158 17 20 39 38 32 26 18 12 14 30 24 23 54 194 26 30 44 43 37 31 23 17 19 35 30 28 66 238 40 46 50 49 43 37 29 23 25 40 35 34 300x100 51 184 9 11 34 33 27 23 15 7 9 25 19 17 64 230 15 17 39 38 32 27 19 12 14 30 24 23 78 281 22 26 44 43 37 32 24 17 19 35 30 28 97 349 34 40 50 49 43 37 29 23 25 40 35 34 400x100 64 230 8 9 35 34 28 22 14 8 10 25 19 17 80 288 12 15 40 39 33 27 19 13 15 30 24 23 99 356 19 23 45 44 38 32 24 18 20 35 30 28 124 446 30 36 50 49 43 37 29 23 25 40 35 34 500x100 78 281 7 9 35 34 28 22 14 8 10 25 19 17 97 349 11 13 40 39 33 27 19 13 15 30 24 23 121 436 17 21 45 44 38 32 24 18 20 35 30 28 151 544 27 33 50 49 43 37 29 23 25 40 35 34 600x100 92 331 7 8 35 34 26 22 14 8 8 25 19 16 114 410 11 13 40 39 32 27 19 13 14 30 25 22 141 508 16 20 45 44 37 32 24 18 19 35 30 28 176 634 25 31 50 49 42 37 29 23 24 40 35 33 800x100 117 421 6 7 35 34 28 21 13 8 10 25 19 18 145 522 9 11 40 39 33 26 18 13 15 30 24 23 181 652 15 18 45 44 38 32 24 18 20 35 30 28 224 806 23 27 50 49 43 37 29 23 25 40 35 34 1000x100 145 522 6 7 34 33 27 21 13 7 9 25 19 17 178 641 9 11 39 38 32 26 18 12 14 30 24 22 220 792 14 17 44 43 37 31 23 17 19 35 29 28 272 979 22 26 49 48 42 36 28 22 24 40 35 33 800x150 175 630 6 7 34 33 27 21 13 7 9 25 19 17 216 778 8 10 39 38 32 26 18 12 14 30 24 23 267 961 13 16 44 43 37 31 23 17 19 35 30 28 328 1181 20 24 49 48 42 36 28 22 24 40 35 33 1000x150 210 756 5 6 34 33 27 21 13 7 9 25 19 17 259 932 8 10 39 38 32 26 18 12 14 30 24 22 321 1156 12 15 44 43 37 31 23 17 19 35 29 28 397 1429 18 23 50 48 42 37 29 23 24 40 35 33 1200x150 243 875 5 6 34 33 27 21 13 7 9 25 19 17 298 1073 7 9 39 38 32 26 18 12 14 30 24 22 369 1328 11 13 44 43 37 31 23 17 19 35 29 28 459 1652 17 21 49 48 42 36 28 22 24 40 35 33 1500x150 290 1044 4 5 34 33 27 21 13 7 9 25 19 17 361 1300 7 8 39 38 32 26 18 12 14 30 24 23 446 1606 10 13 44 43 37 31 23 17 19 35 29 28 551 1984 15 19 49 48 42 37 29 22 24 40 35 33 600x200 290 1044 4 5 34 33 27 21 13 7 9 25 19 17 361 1300 7 8 39 38 32 26 18 12 14 30 24 23 446 1606 10 13 44 43 37 31 23 17 19 35 29 28 551 1984 15 19 49 48 42 37 29 22 24 40 35 33 800x200 178 641 6 7 34 33 27 21 13 7 9 25 19 17 220 792 9 11 39 38 32 26 18 12 14 30 24 23 271 976 13 16 44 43 37 31 23 17 19 35 29 28 334 1202 20 25 49 48 42 37 28 22 24 40 35 33 1000x200 225 810 5 6 35 33 27 22 14 7 9 25 19 17 280 1008 8 10 40 38 32 27 19 12 14 30 24 22 343 1235 12 14 45 43 37 32 24 17 19 35 29 27 426 1534 18 22 50 48 42 37 29 22 24 40 34 33 1200x200 272 979 5 6 35 33 27 22 14 7 9 25 19 17 336 1210 7 9 40 38 32 27 19 12 14 30 24 22 414 1490 11 13 45 43 37 32 24 17 19 35 29 27 512 1843 16 20 50 48 42 37 29 22 24 40 34 33 1500x200 385 1386 4 5 34 33 27 21 13 7 9 25 19 17 475 1710 6 8 39 38 32 26 18 12 14 30 24 23 583 2099 9 11 44 43 37 31 23 17 19 35 29 28 721 2596 14 17 49 48 42 36 28 22 24 40 35 33 LpA values presented with room attenuation 4 db (red 10m 2 - sab). When using room attenuation 8 db (red 25m 2 - sab): LpA - 4dB. NR/NC noise criteria 7

Servicing Remove the grille by gently drawing it out by the frame. Use a screwdriver if necessary. Clean the parts by wiping then with a damp cloth. Push the grille back into place so that the clips lock (or fix by tightening the concealed screws). Product Code AWE-L-H AWU-L-H L = Length 200,+1,..,20000 Option: with balancing plenum PRI or BDR + MSM Remove the measurement and adjustment module by gently pulling the shaft (NB. not the control spindle or measurement tubes!). Wipe the parts with a damp cloth, instead of immersing in water. Reassemble the measurement and adjustment module by pushing the shaft until the module meets the stopper. Push the grille back into place so that the clips lock. Suggested Specifications H = Height 50,+1,..,500 Specifics and accessories FS = Fastening CL Clips CC Concealed screw fastening FI = Finishing AN Anodised MF Mill finished PN Painted The grille shall have horizontal fixed vanes with a 15 angle deflection:awe, no deflection: AWU and vertical adjustable rear vanes, and an 18 mm wide flat frame, anodised or epoxy-painted with a white (RAL 9010) colour. Flow pattern shall be adjustable by rear vanes. CO = Colour W X N Code example White Special colour No painting Option 1 The grille shall be connected to the ductwork using a plenum with mineral wool as sound insulation material. Option 2 The grille shall be connected to the ductwork using a balancing plenum, which comprises polyester fibre with a washable surface as sound attenuation material. The plenum shall comprise an airflow measurement and adjustment unit. The grille shall be removable in order to provide access to the measurement and adjustment module in the plenum. ALE-200-50, FS=CL,FI=AN,CO=N Sub products BDR Plenum PRI Plenum IF Installation frame (Grilles) OD Opposed blade damper (Grilles) 8