WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

Similar documents
Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

GDD - Supply Grille. Halton GDD. Supply Grille

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

TBV - Terminal Unit. Halton TBV. Terminal Unit

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

DAC - Conical Diffuser. Halton DAC. Conical diffuser

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

ULA - Valve. Halton ULA. Valve

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

Halton PRL Plenum for grilles

series Linear grilles

HIGH CAPACITY LINEAR SLOT DUFFUSERS

Aircell Polymer Range

Ceiling swirl diffusers

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Ceiling swirl diffusers with perforated face plate

Compact Grille Model KG

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

Wall and Ceiling Grille

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

REK, LEK, ROK and LOK

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Ventilation grilles for installation into walls, sills or rectangular

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

Slot diffusers, Round duct diffusers. IMP Klima

SDV Vane Swirl Diffusers

REK, LEK, ROK AND LOK

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Ceiling swirl diffusers

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

ADJUSTABLE SLOT DIFFUSER TYPE: SE800

SERIES K GILBERTS. Fixed Blade Grilles. Features

Small Format Circular Diffusers. Small format circular diffuse

CornerAir. CornerAir. Active chilled beam

SERIES K. Fixed Blade Grilles

Ventilation grille Model AL

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P

Grilles Linear Grilles

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

DRUM SLOT DIFFUSER TYPE: RT350

Perforated Face Ceiling Diffusers

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

Ventilation grilles for installation into walls, sills or rectangular

SERIES H. Heavy Duty Adjustable Deflection Grilles

Halton Rex 600 RE6 - Adaptable active chilled beam

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

LINEAR DIFFUSERS AND BAR GRILLES

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

LINEAR SLOT DUFFUSERS

FlowBar High Capacity Slot Diffuser

Air Displacement Vent Units

LINEAR SLOT DIFFUSERS

SERIES HSL. High Capacity Linear

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

Ceiling swirl diffusers

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

Grilles Linear Grilles

Ceiling Slot Diffuser DSC

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

SERIES GSL. Linear Slot Diffuser

ADJUSTABLE PERFORATED AIR SUPPLY DIFFUSER TYPE: DC560S

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Casing Hot galvanised steel / Option: stainless steel EN (AISI316L) Reheat coil EN (AISI 304)

For installation into ductwork

Ceiling Slot Diffuser DSC

Slot diffusers for ceiling installation

Airline Linear Grilles

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

SERIES H. Heavy Duty Adjustable Deflection Grilles

MADEL. DMT fixed blades return grilles at 45º. klin SYSTEM. The DMT series grilles are designed to be used in extractors of cold and hot air.

Transcription:

Halton WDD/WSD Universal Grille Horizontal air supply, suitable also for exhaust Adjustable vertical front vanes, adjustable horizontal rear vanes: WDD, adjustable horizontal vanes: WSD Aluminium construction with elegant outlook Detachable grille enables cleaning of the grille and ductwork Accessories Airflow adjustment damper Installation frame Balancing plenum with measurement and adjustment functions Plenum insulation MATERIAL AND FINISHING PART MATERIAL FINISHING Frame Aluminium Epoxy-painted, (std RAL 9010 50% gloss, Mill finished Vanes Aluminium Epoxy-painted, (std RAL 9010 50% gloss, Mill finished NOTE Special colours available Special colours available Installation frame Galvanised steel Plenum box / spigot Galvanised steel The bevel angles of the outer frame have been welded so that the joints are almost invisible. 1

DIMENSIONS LxH L1 L2 H1 H2 200x100 226 176 126 76 250x100 276 226 126 76 300x100 326 276 126 76 300x150 326 276 176 126 400x150 426 376 176 126 400x200 426 376 226 176 500x200 526 476 226 176 600x200 626 576 226 176 800x200 826 776 226 176 1000x200 1026 976 226 176 600x300 626 576 326 276 800x300 826 776 326 276 1000x300 1026 976 326 276 1000x400 1026 976 426 376 1200x400 1226 1176 426 376 WDD 25 WSD 25 L2 L1 5 H1 48 H2 WDD: With OD (airflow adjustment damper) total depth = 48 mm + 45 mm. WSD: With OD (airflow adjustment damper) total depth = 32 mm + 45 mm. L2 5 25 32 Special dimensions In addition to these standard sizes, other dimensions H1 H2 are available by special order. The maximum size is 1500mm x 600mm 25 L1 ACCESSORIES ACCESSORY CODE DESCRIPTION Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise Plenum BDR Plenum for duct connection (with or without attenuation material) Airflow measurement and adjustment unit MSM For supply installation Airflow measurement and adjustment unit MEM For exhaust installation Sound attenuation IN Mineral wool for the BDR plenum box. Polyester fiber for the PRI plenum box. Flow adjustment damper OD Aluminium opposite blade damper for airflow adjustment Installation frame IF For installation without plenum Visible screw fastening SF Screw fastening Concealed screw fastening CC For installation with BDR plenum or IF frame Wax-bulb actuator (WDD) MT The actuator controls the vane angle depending on the supply air temperature Wax-bulb actuator (WDD) In applications, where both heating and cooling are provided, the air pattern can be changed automatically via the wax-bulb actuator. The wax-bulb actuator alters the angles of the horizontal rear vane depending on the supply air temperature. Neither auxiliary energy nor dedicated control system are needed. When cold air is supplied at a temperature up to 18 C the supply jet is horizontal. The vane angle is 0. As the supply air temperature rises, the actuator piston progressively changes the angle of the rear vanes to direct the supply air jet downwards. Vane angle reaches 45 in 10 to 20 minutes. No maintenance is required for the wax-bulb actuator. 2

WDD WSD Function Supply air is supplied with horizontal and vertical deflection through the vanes into the space: WDD. Supply air is supplied with possible deflection through the horizontal vanes into the space: WSD. The supply air mixes with the room air in front of the grille. The supply air is directed with the horizontal adjustable vanes. Moving the vertical vanes can change the length and form of the flow pattern (WDD). In wall installations, the recommended distance from the ceiling is 200 mm, when the supply air is directed to the ceiling. The rear vane angle can also be controlled by optional wax-bulb actuator (WDD). The grille can also be used as an exhaust unit. Pressure drop, throw pattern and sound data WDD or WSD, wall installation at a distance of 200mm from the ceiling (with Coanda effect) 200x100, 300x100, 300x150, 400x150, 400x200, 600x200 800x200, 600x300, 1000x200, 800x300, 1000x300, 1000x400, 1200x400 Selection example : Note : Requirements : qv = 20 l/s Selection : WDD-400x150 LpA < 35 db(a) LpA = 31 db(a) L0,2 < 25 m L0,2 = 24 m DPtot = 14 Pa When there is no coanda effect (installation greater than 200 mm from ceiling) the throw pattern must be multiplied by 0.7. 3

Sound power level with od damper Use of an OD opposite blade damper, will result in increased pressure loss. The resulting increase in sound level is computed from the selection chart value and the formula below: LpA = DLp + LpA Kp= Adjusted pressure drop Pressure drop in selection chart Example : WDD-400x150 + OD qv = 200 l/s LpA = 31 db(a) without damper OD/GDD DPs= 50 Pa (desired pressure drop) Kp = 50/14 = 3.6 LpA = 31 + 12 = 43 db(a) Throw length correction factor When the throw length is adjusted with the rear vanes, the actual throw length is obtained by multiplying the value obtained from the selection chart by the correction coefficient K1. L0.2 (a) = K1 x L0.2 The correction coefficient K1 is the average for the various grille sizes. Pressure drop correction factor Angle between vanes When the throw length is adjusted with the rear vanes, the actual pressure drop is obtained by multiplying the value obtained from the selection chart by the correction coefficient K2. DPs (a) = K2 x DPs The sound level increases when pressure drop is increased. The correction coefficient K2 is the average for the various grille sizes. Angle between vanes 4

SOUND LEVEL DATA, SUPPLY WDD/WSD qv DPst DPtot F (Hz) LpA NR NC (l/s) (m 3 /h) (Pa) (Pa) 125 250 500 1000 2000 4000 [db(a)] 200x100 58 209 8 13 26 27 26 24 21 16 25 21 18 75 270 12 21 29 30 31 29 27 22 30 26 24 96 346 20 34 33 34 36 34 32 29 35 31 29 122 439 33 55 36 38 40 39 38 34 40 37 34 300x100 72 259 5 8 28 28 27 24 20 13 25 20 18 92 331 8 13 32 32 32 29 26 20 30 25 24 116 418 12 21 35 36 37 34 31 26 35 30 29 146 526 19 33 39 40 41 39 37 32 40 36 34 300x150 113 407 4 8 30 30 28 24 19 10 25 20 18 143 515 7 13 34 34 33 29 24 17 30 25 23 181 652 11 21 37 38 37 34 30 24 35 30 29 225 810 18 33 41 42 42 40 35 30 40 36 34 400x150 152 547 5 8 31 30 28 24 18 10 25 20 18 191 688 7 13 35 34 33 29 24 16 30 25 23 241 868 11 21 38 39 37 34 30 23 35 30 29 301 1084 18 33 42 43 42 40 35 29 40 36 34 400x200 188 677 4 7 32 31 28 23 16 6 25 19 17 237 853 6 11 36 35 33 29 22 13 30 25 23 297 1069 9 18 40 39 38 34 28 21 35 30 29 369 1328 14 27 44 43 42 39 34 28 40 35 34 600x200 258 929 3 6 34 32 28 22 14 3 25 20 18 322 1159 5 9 38 37 33 28 20 10 30 25 23 401 1444 8 14 42 41 38 33 26 17 35 30 29 496 1786 12 22 46 45 43 39 33 24 40 35 34 800x200 366 1318 3 6 36 33 29 4 14 3 25 21 19 455 1638 5 10 40 38 34 16 21 10 30 26 24 557 2005 7 14 44 42 39 27 27 17 35 31 29 665 2394 10 20 47 46 43 37 32 23 40 35 34 1000x200 397 1429 2 5 36 33 28 21 11 3 25 20 18 495 1782 3 7 40 38 33 27 18 7 30 25 24 607 2185 5 11 44 42 38 33 24 14 35 30 29 750 2700 8 16 48 47 43 38 31 21 40 36 35 600x300 369 1328 2 5 35 32 28 21 12 3 25 20 18 457 1645 4 7 39 37 33 27 19 7 30 25 24 566 2038 6 11 43 42 38 33 25 14 35 30 29 696 2506 8 17 47 46 43 38 31 22 40 35 34 800x300 421 1516 2 4 37 34 27 20 9 3 25 19 17 518 1865 3 6 41 38 33 26 16 5 30 25 23 635 2286 4 9 45 43 38 32 22 11 35 30 29 776 2794 7 13 49 47 43 37 29 18 40 35 34 1000x300 489 1760 2 3 37 33 27 18 6 3 25 19 17 599 2156 2 5 41 38 33 24 13 5 30 24 23 726 2614 4 7 45 43 38 30 20 10 35 30 28 880 3168 5 10 49 47 43 36 27 15 40 35 34 1000x400 670 2412 1 3 38 34 26 17 4 3 25 19 16 818 2945 2 5 42 39 32 24 11 3 30 24 22 989 3560 3 7 46 43 37 30 18 8 35 29 28 1191 4288 5 10 50 48 43 35 25 12 40 35 34 1200x400 812 2923 1 3 38 34 28 18 4 3 25 19 17 987 3553 2 5 43 38 33 24 11 4 30 25 23 1199 4316 3 7 47 43 38 30 18 8 35 30 29 1451 5224 5 10 51 48 43 36 25 11 40 35 34 LpA values presented with room attenuation 4 db (red 10m 2 - sab). When using room attenuation 8 db (red 25m 2 - sab): LpA - 4dB. NR/NC noise criteria 5

Installation frame (IF) PRI balancing plenum BDR plenum box Installation The grille is connected to the circular duct using either a PRI balancing plenum or a BDR plenum or alternatively directly to the rectangular duct using the IF installation frame. Visible screw fastening Clips fastening (standard) For ceiling installation, we recommend using visible screw fastening. The auto screws, 4.2x25 (bevel headed screws) are supplied. The grilles are delivered with clips fastening as standard. Clips fastening is used with PRI, BDR and IF. Concealed screw fastening (option) Concealed screw fastening is possible when the grille is installed with an IF installation frame or with a BDR plenum, not with a PRI balancing plenum. Holes are provided for screws in BDR. For ceiling installation, concealed screw fastening is recommended. The dimensions of the installation holes are LxH when an installation frame is used, and (L-5)x(H-5) without installation frame. 30 to 40 6

Adjustment Supply In order to enable airflow adjustment and measurement of airflow rate we recommend connecting the diffuser to a BDR plenum or PRI balancing plenum equipped with the MSM module. The supply flow rate is determined by using the measurement and adjustment module MSM. Detach the grille and pass the tubes and control spindle through the grille. Measure the differential pressure with a manometer. The flow rate is calculated using the formula below. q v = k * p m Exhaust The airflow rate is selected by measuring the pressure difference between the measurement tap on the PRI balancing plenum or BDR plenum and the room air. The corresponding airflow rate is calculated and can be adjusted by turning the control spindle of the adjustment unit MEM. Airflow adjustment damper OD The airflow rate is adjusted by turning the damper blades behind the grille using a screwdriver. The measurement is carried out when grille is installed. Adjust the airflow rate by rotating the control spindle until the desired setting is achieved. Lock the damper position with a screw. Replace the tubes and spindle into the plenum and replace the grille. K-factor for installations with different safety distances (D= duct diameter). PRI Supply >8xD min 3xD Exhaust~>8xD 125 200x100 10.1 12.6 12.4 160 300x100 17.0 21.7 19.7 200 300x150 27.8 33.9 31.1 250 400x150 47.2 55.5 43.4 250 400x200 51.2 55,5 53.7 315 600x200 82.7 93.1 85.6 315 800x200 79.3 83.3 116.4 BDR >6xD min 3xD 100 6 7 125 10 12 160 19 22 200 28 32 250 49 51 315 77 83 7

Servicing Remove the grille by gently drawing it out by the frame. Use a screwdriver if necessary. Clean the parts by wiping them with a damp cloth. Push the grille back into place until the springs lock (or fix by screwing on the concealed screws). Suggested Specifications The grille shall be made of extruded aluminium, with an anodised or epoxy-painted with a white (RAL9010) standard colour. The bevel angles of the outer frame shall be welded so that the joints are almost invisible. Option: with balancing plenum PRI + MSM (MEM) or BDR + MSM (MEM) Remove the measurement and adjustment module by gently pulling the shaft (NB not the control spindle). Wipe the parts with a damp cloth, instead of immersing in water. Remount the measurement and adjustment module by pushing in the shaft until the module meets the stopper. Push the grille back into place so that the clips lock. WDD: The WDD grille shall have horizontal and vertical adjustable vanes. The rear vanes shall direct the supply air jet horizontally. The length and form of the air pattern shall be adjusted by turning the front vanes. WSD: The WSD grille shall have horizontal adjustable vanes and a 25 mm wide radius frame (which shall incorporate a sealing gasket). Optionally The supply air jet shall be controlled according to supply air temperature by a wax-bulb actuator. Alternative 1 The grille shall be connected to the ductwork using a plenum, with mineral wool as sound insulation material. Alternative 2 The grille shall be connected to the ductwork using a balancing plenum, which comprises sound attenuation material made of polyester fibre with a washable surface. The plenum shall comprise an airflow measurement and adjustment unit. The grille shall be removable in order to provide access to the measurement and adjustment module in the plenum. 8

Product Code WDD-L-H WSD-L-H L = Length 200,+1,..,1500 H = Height 100,+1,..,600 Specifics and accessories FS = Fastening CL Clips SF Screw fastening CC Concealed screw fastening FI = Finishing AN PN MF Anodised Painted Mill finished CO = Colour W X N White Special colour No painting AC = Accessories WM Wax-bulb actuator Code example WDD-200-100, FS=CL,FI=AN,CO=N Sub products BDR Plenum PRI Plenum IF Installation frame (Grilles) OD Opposed blade damper (Grilles) 9