Z-TECH FAN Z-TECH FAN WITH Z-CHILL. Features & SPECIFICATIONS

Similar documents
Z-Tech Fan. Features & specifications. page 1 of 13.

Z-chill. Fan & Diffuser System. Features & specifications. page 1 of 13.

Z-TECH3 FAN. installation and Technical operations guide

Z-TECH FAN 3 blade. installation and Technical operations guide

Z-TECH FAN. installation and Technical operations guide

TRI-LITE HVLS SERIES CEILING FANS ABOUT THESE FANS THE TUBERCLE ADVANTAGE THE BENEFITS OF TRI-LITE HVLS FANS

2017 Price Guide. 6 to 24 HVLS Ceiling Fans High Volume Low Speed Technology. Effective through February 1, 2018

EnginEEring and design guide TM

Electronics Cooling. Thermoelectric Coolers. Protective Cooling: Thermoelectric

VENTILATION PRODUCTS. For The Dairy Industry. (519)

Full Profile Insertion


CH5000 Heat Recovery Ventilator

Use the following standards for system design and performance requirements.

AD-1251 Probe with Differential Pressure Transducer

Inverter Speed Ratio Information

2017 CATALOG East Main Street Mesa, AZ

Qty: L50 50W. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45 PM6 60.

LED lighting system. We Brighten Your Brands.

THE TOUGHEST BASKETBALL SYSTEM ON THE PLANET. INTRODUCING THE ALL NEW GOALRILLA DC AND CV IT TAKES MORE TO BE HERE.

Unshrouded 60, 100 and 200 Watts Shrouded 60, 100 and 200 Watts

INSTALLATION MANUAL. Melink Corporation (513) Revision

SLR Series. All-New, Ultra-Low Profile Rooftop HVAC System featuring ComforTEK for Shuttle and School Bus Applications.

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940

UPS packages are charged dimensional, not physical weight.

Unshrouded 60, 100 and 200 Watts Shrouded 60, 100 and 200 Watts

CAPACITIES: SPANS: ROTATION: STYLES: Up to 30' Manual or Motorized Free Standing, Wall Mounted or Gantry

Contact-Cooled Rotary Screw Air Compressors. Nirvana kw ( hp)

CYCLO HBB. ofc. Gearmotor. Premium Efficient Motor Edition. Catalog

Global Finishing Solutions Table of Contents

ExpressBuild STANDARD FAN RANGE

Qty: R4 Type IV Distribution. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45

304 Series LED Recessed Canopy Luminaires

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE

220 to volts. Electronic unit injection

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

ROGERS MACHINERY COMPANY, INC

2520- EC Motor Speed Controller

Big Ass Light High Powered Fixture

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

X3-R. Garaventa X3-R. Residential Inclined Wheelchair Lift. Design and Planning Guide

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

BetaLED Recessed Canopy Luminaires

TECHNICAL SPECIFICATIONS

150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

Low Silhouette Power Roof Ventilator Propeller

AXLE LED PENDANT ASYMMETRIC W W W. L U M E N W E R X. C O M

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Industrial and Commercial Duty IEC Motors

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB H0N

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

Sullair: An Industry Leader

SITESTAR ELECTRONICS CABINET DESCRIPTION

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

Blue e+ chillers with the principle

Powered to Perform. Electric Motors

Mancoolers Models MCY, MCB, MCP

SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

Voltage 220 to or 1800 RPM

Danfoss LX Electric Floor Heating

EQUIPMENT PROTECTION

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

Cat 3412 Diesel Generator Sets

Continuous, Prime, Standby, Mission Critical

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

Generator Set Specifications 60 ekw (75 kva)

S 58 SX S 61 SX. Custom Carrier Mounted Concrete Pump with 4-section Placing Boom

Super-high output LED high bay. Affordable replacement for up to 400W HID. RAIL RCLIGHTING.CA

Commercial Radiant HeaterRH Series

Air-Cooled Liquid Chiller with integrated hydraulic module

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

one giant leap for electric power. The 2-4MW family of diesel generator sets powered by the C175

Guidance Document EP.NA.

Cat C Diesel Generator Sets

AC METRIC (IEC) MOTORS THREE PHASE

Versatile and Rugged Industrial LIthium/LiPO Charger Series

D M S 760 C01 A A 1 1

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

SG-3000 Series Generator Sets

High-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES

The Perfect Fit. Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive. usa.siemens.

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Cat C32 Diesel Generator Sets

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

PRIME 225 ekw 281 kva

Current Automation Catalogue Page 27

Selection Guide Motor Control Device Solutions

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

SOLAR HEATING SYSTEM

SECTION VARIABLE FREQUENCY DRIVE UNITS

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Commercial Blower Coil Air Handlers

Transcription:

Catalog Number: Z-TECH FAN Features & SPECIFICATIONS Notes: Type of Fan: Z-TECH TM INTENDED USE: Ideal for spaces that need air movement to deliver optimum people comfort, safety, and productivity while enabling energy savings, material and labor cost avoidance resulting in the lowest total cost of ownership. Applications include warehousing, manufacturing, gymnasiums, agriculture and other indoor spaces with minimum 14 FT ceiling height. Z-TECH FAN Z-CHILL TM INTENDED USE: The highly engineered, game changing combination of proven technologies brought to you exclusively by Go Fan Yourself! Use your Z-Tech TM fan to temper the air feeding the fan to provide the only true "cooler than ambient" breeze in the HVLS fan market. Heat is also available for spot control of important areas of virtually any facility. Control Z-Chill TM with your building management system and your GFY solution is only limited by your imagination! NUMBER & TYPE OF BLADES: (5) patent-pending Z-Tech blades with 20 plus pitch. BLADE CONSTRUCTION: Extruded anodized aluminum blade with ABS leading edge and end caps with UV inhibitors. Frame is powder coated steel with a cast aluminum hub A356-T6. Blade leading edge color is GFY orange. ELECTRICAL (MOTOR): Superior motor built specifically for Go Fan Yourself. Designed for use with variable frequency drives; wound with 392 (200 C) moisture resistant Inverter Spike Resistant (ISR) magnetic wire. Dramatically extends the life of the motor compared to motors with non-isr wire. ELECTRICAL (CONTROLLER): Premium control with hardware flexibility, programmability, and scalability for an optimal solution. ABB Variable Frequency Drive Nema 4X, IP66. ESFR relay ready to connect to existing fire suppression systems, integral LOTO (lockout, tag-out) disconnect ship standard. ROHS compliant. 208-230v or 460v-480v standard. INSTALLATION: Suitable for mounting by I-Beam, Top Chord angle iron, Bottom Chord angle iron, L-Bracket, and Z-Purlin. Standard mount is used for 6"-10" I-beams, XL mount is used for 12"-15" I- beams. 1 FT down tube is standard. SAFETY: Safety ring (1/4" powder coated steel), two safety cables (5/16" stainless steel aircraft cable), guy wires (1/8" stainless steel aircraft cable) with 4 FT or greater down tube extension. LISTINGS: Motor: IP55 Controller: NEMA 4X, IP66 Z-TECH FAN WITH Z-CHILL DESIGNER SERIES: Optional color & designs available. OPERATING TEMPERATURES: Motor & Gearbox: - 7 o C (20 o F) to 50 o C (122 o F) Controller: - 7 o C (20 o F) to 50 o C (122 o F) WARRANTY: Lifetime warranty on blades, hub and mounting system. 15-year warranty on motor, gearbox and controller. Complete warranty terms located at www.gofanyourself.com/company/warranty. Page 1

TECHNICAL SPECIFICATIONS Number and Type of Blades: Blade Construction: Fan Diameter: Fan Weight: Nominal Motor: Nominal RPM: Air Movement: Max. Destratification Coverage: Max. Cooling Diameter: Power Consumption: Nominal Amperage: Torque: Standard or Optional XL Mount: ABB VFD Controller: Safety Features: Warranty 1 : 5 patent-pending Z-Tech blades with 20 o plus pitch. Extruded anodized aluminum blade with ABS leading edge and end caps with UV Inhibitors. 8 FT 10 FT 12 FT 14 FT 16 FT 18 FT 20 FT 22 FT 24 FT 230 lbs 245 lbs 255 lbs 270 lbs 290 lbs 335 lbs 355 lbs 365 lbs 375 lbs 1 hp (.75 kw) 1 hp (.75 kw) 1 hp (.75 kw) 1.5 hp (1.1 kw) 1.5 hp (1.1 kw) 2 hp (1.5 kw) 2 hp (1.5 kw) 2 hp (1.5 kw) 2 hp (1.5 kw) 100 100 100 73 73 56 56 56 56 44,245 cfm 92,550 cfm 140,860 cfm 166,075 cfm 191,285 cfm 268,920 cfm 346,550 cfm 385,775 cfm 425,000 cfm 80 FT 100 FT 120 FT 140 FT 160 FT 180 FT 200 FT 220 FT 240 FT 65 FT 75 FT 90 FT 115 FT 130 FT 135 FT 150 FT 165 FT 180 FT 892 W 892 W 892 W 989 W 989 W 1449 W 1449 W 1449 W 1449 W 1.94 A 1.94 A 1.94 A 2.15 A 2.15 A 3.15 A 3.15 A 3.15 A 3.15 A 243 ft-lbs 243 ft-lbs 243 ft-lbs 24-lbs 24-lbs 377 ft-lbs 377 ft-lbs 377 ft-lbs 377 ft-lbs Universal I-beam clamps; Down Tubes from 1-10 FT in length. Premium motor control with hardware flexibility, programmability and scalability for an optimal solution. ROHS compliant, ESFR relay ready, integral LOTO disconnect and IP66 Nema 4X rated. Safety ring (1/ 4 powder coated steel), two safety cables (5/16 stainless steel aircraft cable), guy wires (1/8 stainless steel aircraft cable) with 4 or greater down tube extension. 15-year on motor, gearbox and control panel. Lifetime on blades, hub and mounting system. FOOTNOTES: 1) See Installation & Technical Operations Guide for warranty specifications/exclusions (prorated/limited). Example Part Number: GFY-Z-24-460-3-1-STD-T Family Style Diameter Voltage Phase GFY Z Z-Chill 1,9,17 8 (8 FT) 10 (10 FT) 12 (12 FT) 14 (14 FT) 16 (16 FT) 18 (18 FT) 20 (20 FT) 22 (22 FT) 24 (24 FT) 120 2 230 2 460 2 575 2 Down Tube 1 (Single) 2 3 (Three) 2 1 (1 FT) 3 2 (2 FT) 3 (3 FT) 4 (4 FT) 4 X (X FT) 5 Mount STD (6"-10" Beam) 6 XL (12"-15" Beam) 7 Mounting Kit T (Truss/I-Beam) 8 Z (Z-Purlin) 8, 15 WB (Wood Beam) 16 (Concrete Beam) 16 Options DS 11 (Designer Series) (enter 1, 2, 3, 4, or C) 10 RK 12 CP 13 FM 14,18 (Remote Mount Keypad) (Custom Programming) (VFD Field Mounted to Fan Frame) FOOTNOTES 1) Z-Chill TM requires a 2 FT Down Tube. 2) Available voltages: a) Three Phase Applications: 200-240VAC 380-480VAC 500-600VAC b) Single Phase Applications: 100-120VAC 200-240VAC 3) 1 FT Down Tube is standard with all GFY Z-Tech TM fans. If ordering the optional Z-Chill TM a 2 FT Down Tube is required. 4) Down Tubes longer than 3 FT require a Guy Wire Kit shipped automatically with the Down Tube. 5) Consult the factory for Down Tubes longer than 4 FT. 6) Use STD mount for optional Truss Mount, Z-Purlin Mount and Wood / Concrete Beam Mounts (consult a local structural engineer for all concrete beam fan mounts). 7) XL Mount is only used for 12"-15" I-beam applications. 8) Truss Mount and Z-Purlin Mounts require contractor supplied 3"x3"x1/4" steel angles cut to size. See pages in this spec sheet or the Installation and Technical Operations Guide for greater detail. 9) Z-Chill TM only available on Z-Tech TM fans 16 FT in diameter and larger. 10) Designer Series Options (see paperwork in this spec sheet for greater detail, pictures of Designer Series fans and ordering information): a) Option #1 - Motor and all (5) Z-Tech TM leading edges a standard GFY RAL color. Customer logo to replace GFY logo on hub. b) Option #2 - Motor and (3) Z-Tech TM leading edges one standard GFY RAL color, (2) Z-Tech TM leading edges another standard GFY RAL color. Customer logo to replace GFY hub logo. c) Option #3 - Motor and all (5) Z-Tech TM leading edges a standard GFY RAL color. Aluminum Blades one standard GFY RAL color. Customer logo to replace GFY logo on hub. d) Option #4 - Motor and (3) Z-Tech TM leading edges one standard GFY RAL color, (2) Z-Tech TM leading edges another standard GFY RAL color. Aluminum Blades one standard GFY RAL color. Customer logo to replace GFY hub logo. e) Custom Option: Motor MUST be a standard GFY RAL color. Z-Tech TM leading edges and aluminum blades may be a custom color. Customer logo to replace GFY hub logo. 11) Designer Series fans have custom lead times. Consult the factory to receive a lead-time quote for your desired option. 12)Allows the control keypad to be mounted up to 14 FT from the ABB controller. Keypad mounts inside a GFY custom mount. Kit ships complete with 15 FT CAT 6 data cable. Maximum cable length is 150 FT. Longer CAT6 data cables to be supplied by installing contractor. 13)Consult the factory as an extended lead time will apply. Customer's team and GFY's team must communicate so programming details may be identified. There may be additional hardware or software charges. Not all programming options may be available on every control. 14)Optional fan mounted VFD. ABB VFD control mounting bracket and hardware ships with fan to be field installed by the contractor. Contractor needs only run power to the fan location, mount the bracket to the fan, mount the controller to the bracket and make the motor and power connections inside the controller. Remote Keypad Kit ships automatically with a 150' CAT 6 data cable. 15)Z-Purlin applications require a 2 FT Down Tube for all Z-Tech TM fans 18 FT and larger to provide the fan the required 5 FT of clearance above the blades. 16)Contact a local structural engineer for all concrete and wood beam applications to verify the beam will support the fan with the prescribed mounting system. 17) Z-Chill equipped fans must not be hung with the Z-Purlin Kit. Z-Chill equipped Z-Tech fans must mount to the I-Beams in Z-Purlin applications. 18)Fan Mounted VFD option is not available with Z-Chill TM Page 2

Nominal Dimensions Component descriptions Fan Mount. STD shown. XL optional for 12" to 15" I-Beam applications only. Dimension set by Down Tube. Down Tube. 1 FT standard with GFY fans. Optional lengths available. Used to lower the fan to provide blade clearance around obstacles. Fan length with standard 1 FT Down Tube is 44" Motor Frame. Motor. 28" Hub. Follow the Factory Mutual Insurance Company (FM Global) standards, Heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code authorities. z-chill tm GFY's patent pending revolutionary tempered air delivery system. Z-Chill TM is a highly engineered vent/louver system that delivers tempered air to GFY's Z-Tech TM fan. Cool air, hot air, or both can be introduced into the top of your Z-Tech TM fan and optimally spread across the Z-Chill TM coverage area. Z-Chill TM is the most innovative product to hit the HVLS fan market since 1996 when the first HVLS fan was made. Easily installs with any GFY Z-Tech TM fan. A 2 FT down tube is required and will ship automatically with every Z-Chill TM. Available with new Z-Tech TM fans or retrofit existing Z-Tech TM fans. Page 3

GFY Fan Location GUIDELINES G A F D B E GFY Fan Location Guidelines: A. Clearance from solid roof surfaces or solid trusses: 8-12ft fans = 3ft 14-16ft = 4ft 18-24ft fans = 5ft (Open trusses do not need to be considered for air flow restriction) B. Diameter of fan from tip to tip. C. Fan diameter minus 4' (nominal). Blades must be a minimum of 10' from the deck. D. Should be equal to the diameter of the fan from tip to tip. E. Should have at least 2 feet of clearance from obstructions. F. Should not be less than 2 feet with any fan diameter. G. Fan must be located at least 20' from a heat source or exhaust fan to the tip of the blade of the fan. C Legend A. Distance from the ceiling B. Diameter of the fan C. Distance from the floor D. Distance from fan blades to outer walls E. Distance from obstructions F. Proximity of fan tip to roof with pitch G. Heat Source / Exhaust Fan Page 4

TECHNICAL SPECIFICATIONS & MAXIMUM COVERAGE GUIDE 24 Diameter Fan 2) Blade Pitch: 20 o + 3) Minimum Blade Height: 20 FT (Blade from Floor) 4) Maximum Cooling Diameter: 180 FT 5) Maximum Destratification Coverage: 240 FT 6) Air Movement: 425,000 CFM 7) Nominal Rotations Per Minute: 56 RPM 8) Nominal Motor: 2.0 HP (1.5kW) 9) Power Consumption: 1449W@480V 10) Actual Amps: 3.15A@480V 11) Torque: 377 ft-lbs 12) System Weight: 375 lbs 13) Typical Mounting Distance between fans: 170 FT 14) Clearance from solid roof surfaces: 5 FT 27.4 27.4 20 6.1 90 90 22 Diameter Fan 2) Blade Pitch: 20 o + 3) Minimum Blade Height: 18 FT (Blade from Floor) 4) Maximum Cooling Diameter: 165 FT 5) Maximum Destratification Coverage: 220 FT 6) Air Movement: 385,775 CFM 7) Nominal Rotations Per Minute: 56 RPM 8) Nominal Motor: 2.0 HP (1.5kW) 9) Power Consumption: 1449W@480V 10) Actual Amps: 3.15A@480V 11) Torque: 377 ft-lbs 12) System Weight: 365 lbs 13) Typical Mounting Distance between fans: 155 FT 14) Clearance from solid roof surfaces: 5 FT 25.1 25.1 18 4.9 82.5 82.5 20 Diameter Fan 2) Blade pitch: 20 o + 3) Min Blade Height: 16 FT (Blade from Floor) 4) Maximum Cooling Diameter: 150 FT 5) Maximum Destratification Coverage: 200 FT 6) Air Movement: 346,550 CFM 7) Nominal Rotations Per Minute: 56 RPM 8) Nominal Motor: 2.0 HP (1.5 kw) 9) Power Consumption: 1449W@480V 10) Actual Amps: 3.15A@480V 11) Torque: 377 ft-lbs 12) System Weight: 355 lbs 13) Typical Mounting Distance between fans: 140 FT 14) Clearance from solid roof surfaces: 5 FT 22.9 22.9 75 75 16 3.7 Page 5

TECHNICAL SPECIFICATIONS & MAXIMUM COVERAGE GUIDE 18 Diameter Fan 2) Blade Pitch: 20 o + 3) Minimum Blade Height: 14 FT (Blade from Floor) 4) Maximum Cooling Diameter: 135 FT 5) Maximum Destratification Coverage: 180 FT 6) Air Movement: 268,920 CFM 7) Nominal Rotations Per Minute: 56 RPM 8) Nominal Motor: 2.0 HP (1.5kW) 9) Power Consumption: 1449W@480V 10) Actual Amps: 3.15A@480V 11) Torque: 377 ft-lbs 12) System Weight: 335 lbs 13) Typical Mounting Distance between fans: 125 FT 14) Clearance from solid roof surfaces: 5 FT 20.6 20.6 14 6.1 67.5 67.5 16 Diameter Fan 2) Blade Pitch: 20 o + 3) Minimum Blade Height: 12 FT (Blade from Floor) 4) Maximum Cooling Diameter: 130 FT 5) Maximum Destratification Coverage: 160 FT 6) Air Movement: 191,285 CFM 7) Nominal Rotations Per Minute: 73 RPM 8) Nominal Motor: 1.5 HP (1.5kW) 9) Power Consumption: 989W@480V 10) Actual Amps: 2.15A@480V 11) Torque: 24-lbs 12) System Weight: 290 lbs 13) Typical Mounting Distance between fans: 120 FT 14) Clearance from solid roof surfaces: 4 FT 19.9 19.9 12 4.9 65 65 14 Diameter Fan 2) Blade pitch: 20 o + 3) Min Blade Height: 10 FT (Blade from Floor) 4) Maximum Cooling Diameter: 115 FT 5) Maximum Destratification Coverage: 140 FT 6) Air Movement: 166,075 CFM 7) Nominal Rotations Per Minute: 73 RPM 8) Nominal Motor: 1.5 HP (1.1 kw) 9) Power Consumption: 989W@480V 10) Actual Amps: 2.15A@480V 11) Torque: 24-lbs 12) System Weight: 270 lbs 13) Typical Mounting Distance between fans: 105 FT 14) Clearance from solid roof surfaces: 4 FT 17.5 17.5 57.5 57.5 10 3.7 Page 6

TECHNICAL SPECIFICATIONS & MAXIMUM COVERAGE GUIDE 12 Diameter Fan 2) Blade pitch: 20 o + 3) Min Blade Height: 10 FT (Blade from Floor) 4) Maximum Cooling Diameter: 90 FT 5) Maximum Destratification Coverage: 120 FT 6) Air Movement: 140,860 CFM 7) Nominal Rotations Per Minute: 100 RPM 8) Nominal Motor: 1 HP (.75kW) 9) Power Consumption: 892W@480V 10) Actual Amps: 1.94A@480V 11) Torque: 243 ft-lbs 12) System Weight: 255 lbs 13) Typical Mounting Distance between fans: 80 FT 14) Clearance from solid roof surfaces: 3 FT 13.7 13.7 10 3.1 45 45 10 Diameter Fan 2) Blade pitch: 20 o + 3) Min Blade Height: 10 FT (Blade from Floor) 4) Maximum Cooling Diameter: 75 FT 5) Maximum Destratification Coverage: 100 FT 6) Air Movement: 92,550 CFM 7) Nominal Rotations Per Minute: 100 RPM 8) Nominal Motor: 1 HP (.75 kw) 9) Power Consumption: 892W@480 10) Actual Amps: 1.94A@480 11) Torque: 243 ft-lb 12) System Weight: 245 lb 13) Typical Mounting Distance between fans: 65 FT 14) Clearance from solid roof surfaces or solid trusses: 3 FT 11.4 37.5 11.4 37.5 10 3.1 8 Diameter Fan 2) Blade pitch: 20 o + 3) Min Blade Height: 10 FT (Blade from Floor) 4) Maximum Cooling Diameter: 65 FT 5) Maximum Destratification Coverage: 80 FT 6) Air Movement: 44,425 CFM 7) Nominal Rotations Per Minute: 100 RPM 8) Nominal Motor: 1 HP (.75 kw) 9) Power Consumption: 892W@480 10) Actual Amps: 1.94A@480 11) Torque: 243 ft-lb 12) System Weight: 230 lb 13) Typical Mounting Distance between fans: 50 FT 14) Clearance from solid roof surfaces or solid trusses: 3 FT 9.1 30 9.1 30 10 3.1 ADDITIONAL SPECIFICATION NOTES: See GFY FAN LOCATION GUIDELINES in this spec sheet for additional details. 1. Minimum 2 FT of clearance from obstructions. 2. Minimum 2 FT below truss with any fan diameter. 3. Must be at least one fan diameter away from a heat source. 4. Must be at least one fan diameter away from any exhaust fan(s). 5. Must be at least one fan diameter away from any wall. 6. Fan should be centered between sprinkler heads. 7. Lights may need to be spaced 2 FT or greater away from the tip of the fan blade to prevent shadowing. Page 7

TYPICAL MOUNT DETAILS Top Chord Angle Iron Mount The 3"x3"x1/4" steel angles must be supplied by the installing contractor. Hardware used to secure the angles to the mounting structure is not included. If the truss span is wider than 8 FT (4) steel angles and the XL Mount are required. Reference the Installation & Technical Operations Guide or contact GFY for additional instructions. Bottom Chord Angle Iron Mount The 3"x3"x1/4" steel angles must be supplied by the installing contractor. Hardware used to secure the angles to the mounting structure is not included. If the truss span is wider than 8 FT (4) steel angles and the XL Mount are required. Reference the Installation & Technical Operations Guide or contact GFY for additional instructions. Page 8

TYPICAL MOUNT DETAILS Z-Purlin Mount Z-PURLIN REQUIREMENTS The 3"x3"x1/4" steel angles must be supplied by the installing contractor. Maximum unsupported length (see chart below). Spacing between Z-Purlins should 5 FT or less. Z-Purlins must be a minimum of 14 gauge steel. This mounting system may also be required to span concrete beams. Consult a local structural engineer for any concrete beam applications. Purlin Height 8" (20.3 cm) 9" (22.9 cm ) 10" (25.4 cm ) Purlin Length <20' (6.1 m) I ntended use I ntended Use I ntended Use <25' (7.6 m) N/A I ntended Use I ntended Use <30' (9.1 m) N/A N/A I ntended Use Wood Beam Mount Installing contractor must supply L-bracket anchor hardware as described below: (2) 1/2"-13 x "1 1/2" longer than the support structure" Grade 8 Hex Cap Screw (4) 1/2" ASTM F436 Type 1 Grade 8 Mechanical Galvanized Steel Structural Flat Washer (2) 1/2"-13 Grade 8 Steel Nylock Nut Page 9

NORD Motor NORD GFY Helical Gearmotor Specifications Catagory Motor Speed (rpm) Ratio Output Speed (rpm) Service Factor Nominal Output Torque (lb-in) Max. Torque Capacity (lb-in) Voltage (V) Frequency (Hz) Motor Enclosure Type Insulation Class Rated Current 1 (200-240VAC) Rated Current 2 (380-480VAC) Envirionmental Temp Breather Shaft Seal 2HP 1,660 31.16 56 1.90 2,366 4,532 230/460 60 IP55 F 6.34 3.17 50 C Autovent Dual Output Seal 1.5HP 1,660 23.74 73 2.10 1,352 2,885 230/460 60 IP55 F 4.84 2.42 50 C Autovent Dual Output Seal 1HP 1,650 12.2 95 6.20 466 2,912 230/460 60 IP55 F 3.66 1.83 50 C Autovent Dual Output Seal Page 10

ABB VARIABLE FREQUENCY DRIVES ABB ASC355 VFD Controller 200-240V 3 Phase 380-480V 3 Phase ABB ASC250 VFD Controller 100-120V 1 Phase 200-240V 1 Phase 500-600V 3 Phase Fan Control ABB Variable Frequency Drive Enclosure - Nema 4X (IP66). Special Wiring (Thermostats, Fire Alarm Interface, Networking, Etc.) (Optional) Consult Factory. 50 / 60 Hz Operation. All GFY Z-Tech TM Controls ship standard with an Early Suppresion Fast Response Relay ready to connect to existing fire suppression systems. GFY Z-Tech TM Fan Controls ship standard with an integral Lock Out Tag Out Disconnect. ASC355 can run up to 25 fans from a single keypad (Additional wiring required). Page 11

remote mount keypad on board controls Optional Remote Mount Keypad provides unlimited flexibility for your GFY fan installation. Mount the VFD Controller in the ceiling or high on the column for safety and security and drop the keypad down to a user friendly mounting height. Remote Keypad option ships from GFY with a 15 FT CAT6 data cable allowing the keypad to be mounted approximately 15 FT below the VFD Controller. Max CAT6 data cable length is 150 FT. Fan Mounted Control option locates the VFD Controller on a bracket mounting directly to the fan frame. o GFY - Access to the VFD is available o without fan disassembly. BAF - One airfoil must be removed to access the VFD for service work. The Remote Mount Keypad option is included in the cost of this option. GFY provides a 150 FT data cable to connect the Remote Mount Keypad option. Page 12

designer series OPTIONS Go Fan Yourself Standard "RAL" Colors Option #1 Motor, Z-Tech TM & Logo Black #9005 White #9003 Orange #2004 Red #3002 Green #6024 Blue #5005 Yellow #1018 Blue #5015 Option #2 Motor, Mixed Z-Tech TM & Logo Option #3 Motor, Z-Tech TM, Aluminum Blades & Logo Option #4 Motor, Mixed Z-Tech TM, Aluminum Blades & Logo Custom RAL* Motor, Z-Tech TM, Aluminum Blades & Logo Best practice for customers with one custom RAL color? Z-Tech TM = custom color / Motor = #9005 Jet Black Motors are only available in GFY standard RAL colors. Fill out the order form on the following page and submit the completed Designer Series Order Form with your fan order. Please submit customer artwork for the logo in an ".ai" file (Adobe Illustrator) electronically to Go Fan Yourself when placing the order. All custom color requests must be approved by Go Fan Yourself as additional cost and longer lead times may apply. Only the components listed have optional colors. All custom colors may not be available or may not be available on all components. Consult RAL website for color definitions and samples. Page 13

Designer series ORDER FORM Instructions: 1) This form MUST accompany the GFY Z-Tech TM Fan Order 2) Complete one form for each unique Designer Series fan 3) Reference the GFY standard RAL color list shown below 4) Enter the RAL number for each fan component 5) Logo MUST be sent to GFY with your order in an "ai" file (adobe illustrator) Go Fan Yourself Standard "RAL" Colors BLACK #9005 ORANGE #2004 GREEN #6024 YELLOW #1018 WHITE #9003 RED #3002 BLUE #5005 BLUE #5015 Motor Color Enter standard RAL number from the list above. Motors are only available in these 8 standard colors. Z-Tech TM Color Color #1 (All 5 or 3 of 5 blades) Color #2 (2 of 5 Blades Only) Custom colors available. Contact GFY for cost and lead time. Blade Color Enter Blade color. All 5 Blades must be the same RAL color. Custom colors available. Contact GFY for cost and lead time. Custom Logo Please send logo artwork in "ai" file (Adobe Illustrator) NOTES: Page 14