Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer

Similar documents
Agilent InfinityLab LC Series 1260 Infinity II Fraction Collectors

Agilent 1290 Infinity Autosampler

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Agilent SD-1 Purification System ml/min

Agilent 1290 Infinity II Ultra Low Dispersion Kit

Agilent G5632 Valve Kit Instructions

Agilent InfinityLab Quick Change Valve G4237A

Agilent G4239C Valve Kit - Instructions

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D

Agilent InfinityLab Quick Change Valve G4235A Instructions

Agilent 210/218 - Isocratic Pump

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Agilent Valve Kit G4231A/B and G4232A/B/C

Dual-Needle Infinity II Upgrade Kit

Installation Note for Solvent Selection Valve Upgrade Kit (G1360A)

Agilent G4236A 2D-LC Valve Installation Guide

Agilent Online-SPE Direct Inject Kit G4744A

Agilent 210/218 - Binary Pump

Agilent InfinityLab LC Series Multi-wash Upgrade Kit

G1160A Agilent 1100 Series Multiple Purpose Switching Valve

1260 Infinity II Multicolumn Thermostat

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Agilent 218 Purification Solution

Agilent 1200 Series Valves

Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment

1260 Infinity II Degasser User Manual. 5 Maintenance

6890 Installing ¼ Glass Columns

10 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module Infinity Binary Pump User Manual

Agilent 1100 Series Thermostatted Column Compartment. Reference Manual

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Agilent 1200 Series Nano Pump

Agilent 1200 Series High Performance Autosamplers & Micro Well Plate Autosampler

Installing a Purged Packed Inlet

Installing the 6850 Direct Valve Column Connector Kit

Agilent 1260 Infinity Quaternary Pump VL

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Agilent 1100 Series Isocratic Pump. Reference Manual

Agilent 1200 Series Thermostatted Column Compartment G1316A/G1316B/G1316C

Agilent 1260 Infinity Manual Injector

Agilent 1260 Infinity Micro Degasser

Agilent 1200 Series Manual Injector

Agilent 1290 Infinity Quaternary Pump

Agilent 1260 Infinity Capillary Pump

Installing a Purged Packed (PP) Inlet

Agilent 1260 Infinity Binary Pump VL

QuickSplit TM Flow Splitters

Agilent 1200 Series Preparative Pump

98 동방하이테크상사 T.(02) F.(02)

Application Note. Authors. Abstract. Energy & Chemicals

Installing a PTV Inlet

One-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings.

Installing the Flame Ionization Detector EPC Flow Control Manifold

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

Agilent 1290 Infinity Quaternary Pump

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Agilent 1100 Series Capillary LC System. System Manual

Agilent SD-1 Isocratic Solvent Delivery Module

Nickel Catalyst Tube Accessory 19205A

Agilent 1260 Infinity Bio-inert Manual Injector

Agilent 1200 Series Micro Vacuum Degasser

Agilent 1260 Infinity Standard Autosampler

Ultra High Performance Fittings. Fittings Connectors Kits

REMOVING CYLINDER HEAD COVER (VALVE COVER) - AS OF MY 2004 (CAYENNE TIP, CAYENNE MAN) > PRELIMINARY WORK > PRELIMINARY WORK

Agilent 1290 Infinity Binary Pump

1260 Infinity II SFC System

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science

Fixed Flow Splitter *

For more information about Agilent Technologies services please visit our web site using the following URL

System Manual. Agilent 1260 Infinity Capillary LC System

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Installing a PTV Inlet

Installing a Cool On-Column Inlet

Agilent G3510A/G3511A Multimode Inlet

Agilent 1200 Series Standard and Preparative Autosamplers

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

DIONEX ELUENT GENERATOR CARTRIDGE DIONEX EGC 500 K 2 CO 3 HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start

Agilent 1260 Infinity High Performance Micro Autosampler

Installing the CO 2 Cryogenic Oven Cooling Kit

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Agilent 1200 Series Capillary Pump

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter

ÄKTA system Training Guide

Your Essential Resource for INFINITYLAB LC SUPPLIES

1260 Infinity II Degasser

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

ÄKTA avant 150. Product Documentation

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

MET-Biodiesel Capillary GC Columns

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

Installation Guide Thermal Conductivity Detector Accessory 19232E

2017 HPLC Product Catalog 1

260 Solvent Vapor Exit Accessory

User Manual Infinity II High Temperature GPC System

Installing an Auxiliary Pressure Control Module

Lamp House with 2.5 kw lamp

Adjustable Flow Splitter *

Setting up SilFlow for BackFlush in your GC

High Pressure Gradient System. User Manual. Version 1.0 ( )

Transcription:

Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer Technical Note This Technical Note describes the installation of the G9324A Delay Coil Organizer to an Agilent Infinity II system. Contents Delay Coil Organizer 2 Overview 2 Delivery Checklist 3 Parts 4 Installation 5 Assemble the Delay Coil Organizer 5 Assemble and Install the Leak Tray and Leak Sensor 7 Install the Delay Coil Organizer to another Module 8 Install the Delay Coil Organizer into the 1290 Infinity II Preparative Column Compartment 10 Agilent Technologies

Delay Coil Organizer Overview Delay Coil Organizer Overview The Delay Coil Organizer allows the storage of up to three Delay Coil combinations to achieve the required delay volume, and to easily detect and dispose of any possible leaks. The Delay Coil Organizer comes with a Pressure Relief Valve (PRV, as part of the accessory kit) for protection of the Fraction Collector inlet line. Figure 1 Delay Coil Organizer 2

Delay Coil Organizer Delivery Checklist Delivery Checklist p/n Description G7163-60010 Delay Coil Box Assembly G7163-68750 Accessory Kit Delay Coil Organizer 5067-6181 Knitted Delay Kit 1/2/5 m x 1.0 mm ESD Black (OPTIONAL) 5067-6800 Delay Coil Kit 4 8 ml/min ESD (OPTIONAL) 5067-6801 Delay Coil Kit 15 40 ml/min ESD (OPTIONAL) 5067-6802 Delay Coil Kit 40 80 ml/min ESD 1 (OPTIONAL) 5067-6804 Delay Coil Kit 80 200 ml/min ESD 1 (OPTIONAL) 5188-8053 ERI Remote / Leak Module (OPTIONAL) 1 requires Adapter Nut FB 1/4-28-M 5/16-24-F ST (5023-3093), which comes as part of the Delay Coil Kit NOTE Delay coils are specified to 25 bar. Accessory Kit p/n Description 5063-6527 Tubing assembly, i.d. 6 mm, o.d. 9 mm, 1.2 m (to waste) 5067-6655 Leak Sensor Assembly 3 m 5067-6857 PREP Pressure Relief Valve Kit 5067-5685 Clamp Guide Kit-IF-II 5043-0270 Leak plane 5043-0271 Holder leak plane 5043-0275 Clamp guide 3

Delay Coil Organizer Parts Parts Figure 2 Delay Coil Organizer parts Item p/n Description 1 5043-0270 Leak plane 2 5067-6857 PREP Pressure Relief Valve Kit 3 G7163-60010 Delay Coil Box Assembly 4 5067-6181 Knitted Delay Kit 1/2/5 m x 1.0 mm ESD Black (OPTIONAL) 5067-6800 Delay Coil Kit 4 8 ml/min ESD (OPTIONAL) 5067-6801 Delay Coil Kit 15 40 ml/min ESD (OPTIONAL) 5067-6802 Delay Coil Kit 40 80 ml/min ESD (OPTIONAL) 5067-6804 Delay Coil Kit 80 200 ml/min ESD (OPTIONAL) 4

Assemble the Delay Coil Organizer Installation You can install the Delay Coil Organizer either to the side of a particular module (see Install the Delay Coil Organizer to another Module on page 8), or in the 1290 Infinity II Preparative Column Compartment (see Install the Delay Coil Organizer into the 1290 Infinity II Preparative Column Compartment on page 10). Assemble the Delay Coil Organizer 1 Remove the delay coil organizer from its housing by pulling it to the front. 2 Remove the distributor from the delay coil organizer. 3 Install the Adapter Nut FB 1/4-28-M 5/16-24-F ST (5023-3093) for the Delay Coil Kit 40-80 ml/min ESD (5067-6802) and the Delay Coil Kit 80-200 ml/min ESD (5067-6804). 4 Tigthen the adapter nut with a torque of 2.3 Nm (about 10 after fingertight). 5 Mount the required delay coils to the available ports of the distributor, and fix them fingertight. Do not use any wrench or fitting handle. NOTE Use two vertical aligned ports for one coil (combination). You can install up to three combinations. 5

Assemble the Delay Coil Organizer 6 Place the distributor with the installed coil(s) back into the delay coil organizer. 7 Install the distributor by pushing it through the holes in the module frame. 8 Slide the delay coil organizer into its housing to close it. 9 Install the Pressure Relief Valve (PRV) to the top port (OUT) of the Delay Coil (combination) to be used. This will indicate which port is in use. 6

Assemble and Install the Leak Tray and Leak Sensor Assemble and Install the Leak Tray and Leak Sensor 1 Attach the leak tray clamp to the leak tray. 2 Push the leak sensor into its holder. 3 Slide the leak tray onto the bottom of the Delay Coil Organizer. 7

Install the Delay Coil Organizer to another Module Install the Delay Coil Organizer to another Module 1 Assemble and install the leak tray and leak sensor to the delay coil organizer, see Assemble and Install the Leak Tray and Leak Sensor on page 7. 2 Ensure the power switch at the rear of the module is OFF and the power connector is unplugged. 3 Identify the marks for the screws on the side panel of the cabinet assy and screw the clamp guides to the side panel of the cabinet. 4 Slide the delay coil organizer into the clamp guides from front to back. 5 Attach the waste tubing to the leak plane and guide it to a proper waste container. 6 Connect the leak sensor cable to a module with ERI Remote connector (particularly G7159B, or G7161A/B), or to an ERI Remote / Leak Module (5188-8053). 7 Install the capillary from the detector to the bottom port (IN) of the Delay Coil (combination) to be used. 8

Install the Delay Coil Organizer to another Module 8 Install the tubing that goes to the fraction collector to the extended top front port of the PRV. Use the Fitting Handle to apply the correct torque. 9 Fix the waste tubing (1.6 mm x 650 mm ESD) to the bottom of the PRV. 10 Twist the PRV, such that the bottom does not get in the way of the bottom Delay Coil connection, but still ends inside the Leak Tray. NOTE All fittings used in combination with PRV, or inside the Delay Coil Organizer are ¼-28 FB. Fittings to the bottom port of the Delay Coil Organizer are 10-32 coned. 9

Install the Delay Coil Organizer into the 1290 Infinity II Preparative Column Compartment Install the Delay Coil Organizer into the 1290 Infinity II Preparative Column Compartment 1 Install the Delay Coil Organizer into the top valve position of the 1290 Infinity II Preparative Column Compartment according to the Purification Capillary Kits Technical Note. 2 Install the capillary from the detector to the bottom port (IN) of the Delay Coil (combination) to be used. 3 Install the tubing that goes to the fraction collector to the extended top front port of the PRV. Use the Fitting Handle to apply the correct torque. 4 Fix the waste tubing (1.6 mm x 650 mm ESD) to the bottom of the PRV. 10

Install the Delay Coil Organizer into the 1290 Infinity II Preparative Column Compartment 5 Twist the PRV, such that the bottom doesn't get in the way of the bottom Delay Coil connection, while the 650 mm waste line is guided alongside the small mounting plate inside the Column Compartment, to the Leak Plate and the tubing is fixed directly under the leak sensor assembly. NOTE All fittings used in combination with PRV, or inside the Delay Coil Organizer are ¼-28 FB. Fittings to the bottom port of the Delay Coil Organizer are 10-32 coned. 11

Install the Delay Coil Organizer into the 1290 Infinity II Preparative Column Compartment *G9324-90000* *G9324-90000* G9324-90000 Edition: 09/2017 Printed in Germany Agilent Technologies, Inc 2017 Agilent Technologies, Inc Hewlett-Packard-Strasse 8 76337 Waldbronn Germany