ACS motor protection circuit breakers KT 7 Introduction

Similar documents
Technical Information

FMotor Circuit Controllers

Motor Protection Circuit Breakers

Short form catalogue Motor protection and control Manual motor starters

Industry Automation Control Components

Series KTU7 UL489 Molded Case Circuit Breakers

General data 5/37. Overview

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Series KTU7 UL489 Molded Case Circuit Breakers

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Manual motor starters Overview and benefits

KT4 Manual Motor Starter

Ideal for use as a manual starter

Bulletin 190-M Compact Starters. Selection Guide

ACW Molded-Case Circuit Breaker UL 489 Listed

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

DPX earth leakage DPX 3 -I earth leakage

ABB s new control and protection devices

Essential equipment for all your requirements

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

XT IEC Power Control Manual Motor Protectors

3 - Protection components Motor circuit-breakers

3VU13, 3VU16 Circuit-Breakers

Protection Equipment

Protection Equipment. 5/2 Introduction

Bulletin 140M Motor Protectors

Motor Starting Solutions Open Type Version, in Kit Form

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

DPX moulded case circuit breakers

DPX Magnetic only

Motor Controllers + Circuit Breakers

Motor Circuit Breakers C4

Protection components

Electronic circuit breaker EBU10-T

Manual Motor Starters. Meta-MEC

Low voltage circuit breakers

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Technical Information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Motor Applications Automation. Command and Signalling Power Management Product Overview for Machinery

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

cor Long Run Experience

Self-protected Combination Starters System PKZ 2-SP

Motor Protection Circuit Breakers 3VU13 and 3VU16

Low voltage switch gear

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Components for EEx e Panels

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Manual Motor Starters

WORKSHOP SPECIFICATIONS

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Circuit breakers for power distribution A1 Ordering information

Ktec Contactors and thermal overloads

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Electromagnetic Industries LLP

Selection Guide Motor Control Device Solutions

KT7. Methods. of Applying. & Molded Case Circuit Breakers F119. Motor Circuit Controllers

DPX Electronic + earth leakage

Protective Devices: Circuit-Breakers 1 )

MS General Information Extended Product Type: MS

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Thermal-magnetic Miniature Circuit Breaker 4230-T...

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

UMBW-UL489 and UL1077 Listed

max pole for t=15 ms

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Short form catalogue. Motor protection & control

FMotor Circuit Controllers & Circuit Breakers

KT4 Manual Motor Starters

Circuit-Breakers Bulletin 140 / KTA 3

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Manual. Industrial Controls. Protection Devices. SIRIUS 3RV Motor Starter Protectors. Edition 12/2017. siemens.com

Selective main circuit breakers S 750 series Technical Data

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

New Dimension in Motor Protection Manual Motor Starter MS116

DX³ 4-pole RCBO 6000 A/10 ka

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

and other modular devices for low voltage installation

UBW Family UL489 Molded Case Circuit Breakers

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

Features. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12

Short-circuit current limiter S800-SCL-SR

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

AF series contactors (9 2650)

GLOBAL RANGE. Global Range Motor Control. Contactors. Features. Applications. Overload Relays. Features. Applications. Manual Motor Starter Features

Tmax Molded Case Circuit Breakers

01 Spectra Plus - Introduction

Enclosures. See Section Typical Description

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Series L9 UL489 Miniature Circuit Breakers

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Miniature Circuit Breakers

Transcription:

Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different protection characteristics all covering currents up to Amps. KTA 7 Motor protection circuit breaker KTB 7 Starter protection (magnetic only) KTC 7 Transformer and high inrush current motors Protection characteristic Magnetic Thermal KT 7 available in two frame sizes Motor KTA 7 Starter KTB 7 Transformer KTC 7 1 x Ie 1 x Ie x Ie Yes None Yes Simplified assembly and stock For the entire range, a common and complete array of accessories are available. Auxiliary contacts, trip contacts and voltage / undervoltage release can be snappedon or built into the KT 7 devices without tools. The circuit breakers follow consistently the ideas of the Advanced Control System (ACS). All components are designed for electrical and dimensional coordination which makes assembly extremely easy. Consistent 9 mm spacing simplifies planning and installation. CA 7 and KTA 7 22 kw with type 2 coordination Tomorrow s technology today Sophisticated construction and the latest technology in materials results in outstanding features and performance without the need for current limiters. High and effective current limiting and an extremely short dropout time produces an excellent short circuit breaking capacity. Combined with other ACS components, powerful load feeders are assembled in an economical way. Type 2 coordination is automatic Due to the high speed performance, the circuit breakers are compatible electrically and mechanically with short circuit coordination Type 2 according to IEC 6097. No oversizing of the contactor is required, therefore you save time in selection and planning with security in operation assured. Clear visual and electrical signals The rotary handle ensures quick and secure recognition of the operating status. The jump mechanism has exactly defined operation modes i.e., Off, On and Trip. Manipulation errors are almost impossible. To reset a trip contact, simply reset the circuit breaker. You will always see the real operating state of the load feeder represented. The various trip contacts allow optimal plant floor production by quickly detecting defective system parts. The unique front mounted trip contact saves valuable panel space. A red short circuit trip flag clearly shows the reason for trip. Complete type 2 coordinated starter with connection links OFF ON TRIPPED 2

Main features KT 7 has more advantages Standard and high breaking capacity up to Amps No current limiters required Differential phase failure protection Magnetic only version for starter combinations with separate overload (e.g. CEP 7) Version for high inrush current loads or transformer switching Common accessories up to Amps Rotary handle for all frame sizes Front and side mount auxiliary contacts Test trip lever Separate signalling of thermal and short circuit tripping Rotary door interlock extension handle Highly flexible accessories Front mounted trip and signal contacts Side mounted shunt and undervoltage trip modules Compact busbars in different spacing Handle padlock accessory Disconnect device with control circuit testing facility Shunt trip module Undervoltage trip module Padlockable handle KT 7 DS for padlocks Short circuit breaking capacity I cu The rapid current limiting characteristic of KT 7 ensures a minimum breaking capacity of ka over the range up to Amps ( Amps including the KTA ). Front mounted auxiliary contact Compact busbar Efficient termination to IEC 97 Reliability starts with good terminations. The terminals of the Amp frame allow for up to 6 mm wire size while the Amp frame size uses effective cage terminals with two separate wire compartments. Reliable contacts with jump system The switching mechanism prevents teasing of the contact system during manual operation and preserves the life of the contact system, (Important for motor starting). Tripped

KTA 7S ACS motor protection circuit breakers KT 7 Technical information characteristics Motor protection circuit breaker Rated Thermal Magnetic Switching of phase AC motors, AC 21, AC Icu Ics operational release release current Ie adjustment operating phase (kw) ( Hz) 00/ V Cat. No. (A) range (A) current (A) V 00/ V 690 V (ka) (ka) Standard range 0.1 Amp (90 x x 69.5 mm) KTA 7S0.A KTA 7S0.A KTA 7S0.A 0. 0. 0. 0.1 0. 0. 0. 0. 0. 2.1. 5.2 0.02 0.06 0.09 KTA 7S0.6A 0.6 0. 0.6 8.2 0.06 0.09 0.12 0.18 0. KTA 7S1A 1 0.6 1 1 0.12 0. 0.7 0.55 KTA 7S1.6A 1.6 1 1.6 21 0.18 0. 0.7 0.55 1.1 KTA 7SA KTA 7SA KTA 7S6.A KTA 7SA KTA 7SA KTA 7SA KTA 7SA 6. 1.6 6. 6. 18 0.7 0.55 5.5 High performance range 1.6 Amp (90 x x 79.5 mm) KTA 7H KTA 7HA KTA 7HA KTA 7H6.A KTA 7HA KTA 7HA KTA 7HA KTA 7HA 6. 1.6 6. 6. 18 0.7 0.55 5.5 High performance range 6. Amp (0 x 5 x 9.5 mm) KTA 7H KTA 7HA KTA 7HA KTA 7HA KTA 7HA KTA 7HA KTA 7HA 6..... 18 2 585.7 5.5 5.5 22 22 0 7 Notes: / V rated coils are suitable for use on /00 V in accordance with AS 6008: 00. 12

Technical information characteristics Magnetic only circuit breaker (feed or load feeder) Rated Magnetic Switching of phase AC motors, AC 21, AC Icu Ics operational release phase (kw) ( Hz) 00/ V current Ie operating Cat. No. (A) current (A) V 00/ V 690 V (ka) (ka) Standard range 0. Amp (90 x x 69.5 mm) KTB 7S0.A KTB 7S0.A KTB 7S0.A KTB 7S0.6A KTB 7S1A KTB 7S1.6A KTB 7SA 0. 0. 0. 0.6 1 1.6 2.1. 5.2 8.2 1 0.06 0.09 0.12 0.18 0. 0.7 0.02 0.06 0.09 0.12 0.18 0. 0.7 0.55 High performance range Amp (90 x x 79.5 mm) 0. 0.7 0.55 1.1 KTB 7HA KTB 7HA KTB 7H6.A KTB 7HA KTB 7HA KTB 7HA 6. 0.7 0.55 High performance range Amp (0 x 5 x 9.5 mm) KTB 7HA KTB 7HA KTB 7HA 585 5.5 6. 1 22 22 0 7 High current circuit breakers Rated Thermal Magnetic Switching of phase AC motors, AC 21, AC Icu Ics operational release release phase (kw) ( Hz) 00/ V current Ie adjustment operating Cat. No. (A) range (A) current (A) V 00/ V 690 V (ka) (ka) Standard range 0. Amp (90 x x 69.5 mm) KTC 7S0.A KTC 7S0.A KTC 7S0.A KTC 7S0.6A KTC 7S1A KTC 7S1.6A KTC 7SA KTC 7SA KTC 7S6.A KTC 7SA KTC 7SA 0. 0. 0. 0.6 1 1.6 6. 0.1 0. 0. 0. 0. 0. 0. 0.6 0.6 1 1 1.6 1.6 6. 6..2 5.2 8.2 1 21 0.06 0.09 0.12 0.18 0. 0.7 0.55 0.02 0.06 0.09 0.12 0.18 0. 0.7 0.55 0. 0.7 0.55 1.1 High performance range Amp (90 x x 79.5 mm) KTC 7HA KTC 7HA 5.5 High performance range Amp (0 x 5 x 9.5 mm) KTC 7HA KTC 7HA 18 2 585 5.5 6. 22 Notes: / V rated coils are suitable for use on /00 V in accordance with AS 6008: 00. 1

Technical information Time current characteristics Components for 22 kw Type 2 coordinated starter 1. Thermal release trip current: The adjustable inverse bimetal trip (with differential action) reliably protects motors against overloads. The curve shows the mean operating current at an ambient temperature of C starting from cold. Careful testing and setting ensures effective motor protection even in the case of singlephasing. Overload characteristics are also valid for transformer protection. 2. Magnetic release trip current: The instantaneous magnetic trip has a fixed operating current setting. This corresponds to 1 times the highest setting of the thermal overload trip. (Transformer protection x Ie max.) At the upper thermal trip setting, this tripping current is 1 () times; at a lower setting it is correspondingly higher. Current setting IeF: The overload trip corresponds to a thermal overload relay in a motor starter conforming to IEC 60971. If a different value is prescribed (e.g. reduced Ie for cooling medium having a temperature higher than 0 C or a place of installation higher than 00 m above sea level), the setting current is equal to the reduced rated current Ie of the motor. Notes: 1 ) Typical mean trip characteristic. For specific curves with tolerances please enquire. 1

Technical information Let through energy at V Let through current at V

Dimensions (mm).5 90 ➊ ➊ ➌ 18 2.8 ➍ ➍ ➋.5.5 5 9 62 72 KT 7S, KT 7H KT 7S KT 7H Mounting on DINrail EN 0225 Auxiliary contact (side mounted) π Undervoltage trip or shunt trip Auxiliary contact (front mounted) KT 7H KT 7H Mounting position a) KTA 7 mm KTA 7 mm