Flow Computer Installation

Similar documents
CYCLOPS Z Purge Indicator

CYCLOPS Z Purge Indicator

CYCLOPS X Purge Controller XP Version

CYCLOPS Y Purge Indicator

STP-MLD. Installation and Owner s Manual

Rosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol

CYCLOPS X Purge Controller SM Version

RegFlo TM RF100 Series Pressure and Flow Instruments

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Model 3051 Sensor Module Replacement

INTERNATIONAL METAL ENGINEERING

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Rosemount 3095FT MultiVariable Flow Data Logger

by Jim Phillips, P. E.

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Series 3730 Electropneumatic Positioner Type

Ignition energy enough for igniting the mixture is available, such as sparkles generated by friction and impaction, electric arc or hot surfaces.

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

Rosemount 4088 MultiVariable Transmitter

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

Installation, Operation & Maintenance Manual

Rosemount 4088 MultiVariable Transmitter

Type 2000 Transducer Product Instructions

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

KENCO ENGINEERING COMPANY

STP-MLD Installation and Owner s Manual

The 285 Annubar Primary Element Series

Instruction manual. Smart Thermal Mass Flow Meter. TYPE : 3000S Series. ientek Co., Ltd.

Petroleum industries are dealing with different hazardous materials starting from storing, processing and distributing the petroleum products These he

Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital)

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

CAUTION The sensor must always be completely filled with process media in order to measure accurately.

Product Manual. EX40, Version Last Updated: 11/7/16. Product Description:

instrument manifolds Instrument Manifolds Index General Purpose Manifolds Overview 1 2 Valve 2 3 Valve 4 5 Valve 6 Mounting kits 8

Thermal Mass Flow Meter (Analog)

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Low Profile Insertion Vortex

ELECTRICAL INSTALLATION

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

High Pressure Solenoid Valves

Rosemount 3051CFA Annubar Flowmeter

Figure 1: WPR2 Dimensions and Hardware

PF 3100 ION PILOT CARD PRO.FIRE

Manifold & Gauge Valves I [

MEASUREMENT SOLUTIONS FOR THE OIL & GAS INDUSTRY

2 Fluid Level Management

IFOA Integral Flow Orifice Assembly

SR100 Series Service Regulators. Technical Bulletin

STP-MLD+ Installation and Owner s Manual. Manual # Revision Date Changes from previous revision

SPECIAL SPECIFICATION 8676 Solar Panel Power Supply System

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

The installation and maintenance of this product must be done under the supervision of an experienced

Hand & Gauge Isolation Valves Needle Valves Gauge Valves Block & Bleed Valves. Manifolds

Instrumentation Manifold Valves

Evaporative Emissions

Hand & Gauge Isolation Valves Needle Valves Gauge Valves Block & Bleed Valves. Manifolds

Rosemount 3051S Electronic Remote Sensor (ERS) System

VAREC 5910B AND 5920B SERIES RELIEF VALVE WITH FLAME ARRESTER

Model 5000 Level Controller

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

Pneumatic Isolation Module

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

Venting valves. Valves. Manually actuated. Venting valves. Installation elements

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Product Data Sheet , Rev GA Catalog Content

Solutions beyond products...

SynergEX Panelboards for Hazardous Locations

ABB MEASUREMENT & ANALYTICS DATA SHEET. AV1 and AV2 Characterizable pneumatic and electro-pneumatic positioners

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

MPD Manifold 4 x psi with Integrated Control System and Coriolis Flowmeter

Installing an Auxiliary Pressure Control Module

SECTION HVAC POWER VENTILATORS

SKINNER Intrinsically Safe Series Four-Way

BLACKMER BYPASS VALVES

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Smart Pressure Transmitter

B21 Series BASOTROL Gas Valve

The use of batteries in hazardous areas. 1. Type of batteries and technical evolution. March 2018

Hot Tap Insertion Vortex

1000 Series Piston Type Differential Pressure Gauges

Rosemount 1195 Integral Orifice Primary Element

Diesel Engine Shutdown System

SECTION CENTRIFUGAL HVAC FANS

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter

Instrument Valves and Manifolds

Design and Application Details

Gas Conversion Kits and Instructions

Rosemount 485 Annubar Flanged Assembly

NV Direct Coupled Globe Valve Actuator

Installation, Operation, and Maintenance Manual

NC State University Design and Construction Guidelines Division 23 Energy Management

VAREA-METER FLOW MEASUREMENT BY-PASS TYPES

Easytork Solenoid Valve IOM

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

Rosemount 3051S Series of Instrumentation

AKRON ELECTRIC, INC. CONDUIT PRODUCTS GR SERIES... EYS SERIES... TU SERIES... XBD-50 SERIES...

Hydro-Flow Model 3100

Transcription:

Flow Computer Installation WARNING: Only personnel who are experienced with field wiring should perform these procedures. All field wiring must conform to the National Electrical Code, NFPA 70, Article 501-4(b) for installations within the United States. Additional Local wiring ordinances may also apply. Installation Overview Read the following steps before installation. 1. Pre-Configure flow computer Input/Outputs Connect RS232 Communication (3 wires TX, RX and Ground) Wire the flow computer to the external power source and power the unit. Verify Display is ON. Configure flow computer using Dynacom Window Software on PC Disconnect the power and the unit is now ready to install. 2. Remove the meter run from service 3. Mount the flow computer assembly according to the mounting procedures. 4. If an external RTD is required, install the RTD and connect it to the termination board. 5. Connect the impulse lines if frequency input is configured. 6. Install all other input/outputs according the pre-configured software (Analog inputs, Status inputs, Switch outputs and Analog outputs). 7. Wire the flow computer to the external power source and power the unit. 8. Verify Display is ON. 9. Connect the flow computer unit to any other external communication devices such as DCS or PLC. 10. Calibrate the inputs from multi-variable sensor, analog input, and RTD using the calibration buttons on the Dynacom software. 11. Calibrate the Analog Output if used. 12. Verify the status inputs and switch outputs. 13. Place the meter run in service 14. Monitor the flow computer and Consult the Fault Finding if a problem is incurred.

Installation Requirements To plan an installation, location, ground locations, climate, and site accessibility and application should be considered. Environmental Requirements The flow computer enclosure is classified as a NEMA 4 equivalent enclosure. That provides the level of protection required to keep the units operating under a variety of weather conditions. The flow computer is designed to operate over a -40 to 85 C (-40 to 185 F) temperature range. The LCD temperature range is -20 to 70 C (-4 to 158 F). Errors or failure of the unit could occur if operation is beyond the recommended temperature range. Compliance with Hazaardous Area Standards The flow computer unit also has a Class I Division 1, 2, Groups A, B, C & D approval. Class defines the general nature of the hazardous material in the surrounding atmosphere. Class I is for locations where flammable gases or vapors may be present in the air in quantities sufficient to produce explosive or ignitable mixtures. Division defines the probability of hazardous material being present in an ignitable concentration in the surrounding atmosphere. Division 1 locations are presumed to be hazardous. Division 2 locations are areas where gas, dust or vapors can exist under abnormal conditions. Group defines the hazardous material in the surrounding atmosphere. Group A Atmosphere containing acetylene, gases or vapors of equivalent hazards. Group B Atmosphere containing hydrogen, gases or vapors of equivalent hazards. Group C Atmosphere containing ethylene, gases, or vapors of equivalent hazards. Group D Atmosphere containing propane, gases, or vapors of equivalent hazards. WARNING: Installation in a hazardous area could result in personal injury or property damage.

Mounting the Flow Computer The flow computer enclosure assembly can mount directly to an orifice plate meter or cone meter by using a 5 valve manifold. Hardware A 5 valve manifold for connecting process lines to the flow computer, mounting adapter, the threaded HEX adaptor, tubing and/or pipe for plumbing process connections, and other tools and accessories. To prevent fittings from turning and/or to avoid putting tension on stainless steel tubing, use a backup wrench to attach stainless steel tubing to a manifold. WARNING: The tubing and fixtures used to connect the flow computer to the flow line must be manufactured from materials that are appropriately rated for the pressure of the process. Installation Steps 1. Remove the meter run from service. 2. Bolt a flange-by-flange 5-valve manifold to the flow computer Locate the H and L markings on the flow computer sensor body Orient the flow computer and manifold assembly Considerations: The upstream side of flow line must be connected to the sensor s High port. The downstream side of flow must be connected to the sensor s Low port. For orifice plate applications, the handle of the orifice has the word Inlet on the side that faces upstream. Rotate flow computer to face the desired direction 3. Position the manifold so that all valves are easily accessible. 4. Connect the flow computer and manifold assembly to the differential pressure meter. A mounting adapter may be required. Hardware requirements will vary. 5. Locate the Multivariable RTD boss, remove the nut, and install RTD assembly if using the Multivariable RTD. It using the on-board RTD connection bring the RTD wiring through any of the ¾ NPT side openings on the housing. 6. Route any additional inputs/outputs or communication cable connections, etc. through the conduit ¾ NPT opening at the top of the flow computer. In hazardous environments, add a conduit seal. NOTE: For wiring drawings for a particular flow computer model please refer to that models manual.

7. Perform a manifold leak test Verify the instrument is properly connected to the pressure source Close vent valve. (The bypass/block valves should be open) Close bypass and block valves to isolate pressure between the block valve and the flow computer. Open both equalizer valves to distribute pressure throughout. Monitor the pressure reading and watch for a steady decrease in pressure. If leakage is indicated, depressurize the system by opening bypass and block valves, then check manifold and piping joints. Retest the leaks. If the test is leak free, close equalizing valves and the open the vent. Repair or replace the manifold if required. 8. The transmitter should be zeroed after mounting in order to correct for installation effects. 9. Verify the zero offset if required WARNING: Do not put flow computer into service until the valves are positioned properly.

The following Figures are a basic illustration of a direct-mount installation

DFC Engineering Bulletin

DFC Engineering Bulletin

DFC Engineering Bulletin

CHAPTER 1: Explosion-Proof Installation Drawings

DFC Engineering Bulletin