Mini-Roto TM Paddle Wheel Installation & Operation Manual

Similar documents
Super-Safe-Plus Roto-Bin-Dicator

Roto-Bin-Dicator PRO Installation & Operation Manual

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

BMRX Series Rotary Level Indicator

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

BMRX Series ROTARY LEVEL CONTROL

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

Bin-Dicator FEATURES AND BENEFITS

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Installation, Operation & Maintenance Instructions

Service Instructions. Models: SLC-B & SXLC-B Hopper Level Control

ROTARY Point Level Measurement for Inventory Control

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

Level Devices. Rotary Level Indicators Roto-Bin-Dicator

ISO-9001:2000 certified Aplus Finetek Sensor, Inc.

Model 550 Series Vibration Switches

IMPORTANT SAFEGUARDS

Shortening Disposal Unit

THE ORIGINAL DRY BULK LEVEL MEASUREMENT & CONTROL

PRO REMOTE Series CAPACITANCE PROBE

MP461SC Flex Probes* Installation Instructions

(SDU 50, SDU 90, and BKSDU) Shortening Disposal Unit * * Installation, Operation, Service, and Parts Manual

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

THE LEADER The Leader IN DRY BULK in LEVEL Dry MEASUREMENT

Lube Level Maintainer

Air Curtain. Installation, Operating and Maintenance Instructions

Installation And Operation Instructions

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Rotary Paddle Bin Monitor MODEL KA & KAX

SAVE THESE INSTRUCTIONS

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

The Mobrey product range provides reliable point level detection in a variety of dry solid applications

TrueCap RF Capacitance Level Sensor

RP-4000 Reserve Power Control

PRO REMOTE 25 LV CAPACITANCE PROBE

Switching DC Power Supply

TABLE OF CONTENTS SPECIFICATIONS...3 SAFETY SUMMARY...4 INTRODUCTION...5, 6 INSTALLATION...7, 8, 9, 10 TESTING THE REMOTE OPERATION AIR PURGE...

Operating Instructions

Model 5000 Level Controller

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

Installation and Operation Manual

WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES

Bourdon Tube Pressure Switches

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

Installation And Operation Instructions

CVR-625. Compact Vibrating Rod Instruction Manual

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Direct Coupled Damper Actuator Model MY6050A1001

Installation Operation Maintenance ADDENDUM

WIND STOPPING 14 (WMI) AND WIND STOPPING 16 (WMH) INDUSTRIAL SERIES

VEGETABLE OIL DISPOSAL UNIT (MSDU) OPERATOR & SERVICE MANUAL

Quarter Master Series 94 Actuator

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Bin Level Control. Original Roto-Bin-Dicator. Original Roto-Bin-Dicator Specifications

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

WARRANTY INFORMATION...

1100 Series Piston Type Differential Pressure Gauges

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm

Lube Level Maintainer

MF4E MF4E

Instruction Manual PN-Z PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation.

SECTION MOTOR REQUIREMENTS for HVAC

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Electrical Installation

Installation and Operation Manual. Value Switch Package (VSP and VSP+)

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

QUALITY MISTING PUMPS

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

Installation And Operation Instructions

USER MANUAL English / Español

General Installation Instructions for Valves and Gates

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

KOBOLD DF-MA Flow Transmitter. User Instructions

Operation and Maintenance Manual for. Joyce/Dayton Linear Actuator Pound Capacity DC Actuator, LA152L, and LA152C

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

Installation Instructions for Eaton Surge Protective

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

Turn-Dex Rotary Vane Actuators

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

CHEM-FEED. Engineered Skid Systems. ProSeries. by Blue-White Ind.

Illuminator System Series CM

WALL-MOUNT SCONCE LIGHT OWNER S MANUAL

DP140e. Installation & Operations Manual

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Auto-Flo Air-Assist Automatic Dispensing Valve

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

LTX RF LEVEL SENSOR. Instruction Manual

FSAF24(-S) US, FSAF120(-S) US

LEVEL CONTROLS 313 IOM

MOTORTRONICS Solid State AC Motor Control

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

FHSCP-UNV-10P-L-SD SPECIFICATIONS

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

Transcription:

IOM LMR8000 Rev. F Mini-Roto TM Paddle Wheel Installation & Operation Manual

Mini-Roto TM Paddle Wheel Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... Inspection and Handling Disposal and Recycling Storage II. GENERAL SAFETY...2 Authorized Personnel Use Misuse III. PRODUCT DESCRIPTION... Theory of Operation Special Feature IV. MECHANICAL INSTALLATION...4 Location and Installation Mounting Surface Preparation V. ELECTRICAL INSTALLATION...5 Field Wiring Figure : AC Circuit Board Figure 2: DC Circuit Board

SAFETY SYMBOLS WARNING: IDENTIFIES CONDITIONS OR PROCEDURES, WHICH IF NOT FOLLOWED, COULD RESULT IN SERIOUS INJURY. RISK OF ELECTRICAL SHOCK. CAUTION: IDENTIFIES CONDITIONS OR PROCEDURES, WHICH IF NOT FOLLOWED, COULD RESULT IN SERIOUS DAMAGE OR FAILURE OF THE EQUIPMENT.

Mini-Roto TM Paddle Wheel I. HANDLING AND STORAGE SAVE THESE INSTRUCTIONS INSPECTION AND HANDLING Do not dispose of the carton or packing materials. Each package should be inspected upon receipt for damage that may have occurred due to mishandling during shipping. If the unit is received damaged, notify the carrier or the factory for instructions. Failure to do so may void your warranty. If you have any problems or questions, consult Bindicator Customer Support at -800-778- 9242. DISPOSAL AND RECYCLING This product can be recycled by specialized companies and must not be disposed of in a municipal collection site. If you do not have the means to dispose of properly, please contact Bindicator for return and disposal instructions or options. STORAGE If the Mini-Roto is not scheduled for immediate installation following delivery, the following steps should be observed:. Following inspection, repackage the unit into its original packaging. 2. Select a clean dry site, free of vibration, shock and impact hazards.. If storage will be extended longer than 0 days, the unit must be stored at temperatures between -40 and 70 C in non-condensing atmosphere with humidity less than 85%. CAUTION: DO NOT STORE A NON-POWERED UNIT OUTDOORS FOR A PROLONGED PERIOD. LMR8000 Rev. F

II. GENERAL SAFETY AUTHORIZED PERSONNEL All instructions described in the document must be performed by authorized and qualified service personnel only. Before installing the unit, please read these instructions and familiarize yourself with the requirements and functions of the device. The required personal protective equipment must always be worn when servicing this device. USE The device is solely intended for use as described in this manual. Reliable operation is ensured only if the instrument is used according to the specifications described in this document. For safety and warranty reasons, use of accessory equipment not recommended by the manufacturer or modification of this device is explicitly forbidden. All servicing of this equipment must be performed by qualified service personnel only. This device should be mounted in locations where it will not be subject to tampering by unauthorized personnel. WARNING: ALWAYS REMOVE POWER BEFORE SERVICING. MISUSE Improper use or installation of this device may cause the following: Personal injury or harm Application specific hazards such as vessel overfill Damage to the device or system If any questions or problems arise during installation of this equipment, please contact the Bindicator Customer Support at 800-778-9242. 2 LMR8000 Rev. F

III. PRODUCT DESCRIPTION THEORY OF OPERATION The Mini-Roto utilizes a low torque, slow speed permanent magnet synchronous motor and two micro switches. During normal operation (no material present) the synchronous motor rotates the paddle at RPM. When the paddle rotation is impeded by material surrounding it, the motor rotates and activates two micro switches. One switch is used to control the customer s equipment. The second switch will shut off the motor, illuminate the red Alarm LED and turn on the heater. SPECIAL FEATURE The inside lower frame houses a tension spring for torque adjustment. The units are shipped to our customers in high sensitivity for low bulk density materials. The spring should be moved to the next peg (peg furthest away from the motor assembly) for high bulk density material applications. CAUTION: IF THE SPRING IS MOVED, ENSURE IT IS DIRECTED TOWARDS THE OUTSIDE OF THE PEGS. THIS WILL PREVENT THE SPRING FROM IMPEDING ON THE PIVOT OF THE MOTOR. FUNCTIONAL Operating Power Motor Rating Switch Rating 20/240 VAC, 24 VDC or 24 VAC Permanent-magnet synchronous, 2 watts SPDT 0A 25 VAC 0A 250 VAC / 2 A 25 VDC / 4 A 250 VDC Operating Temperature -40 F (-40 C) to 200 F (9 C) PHYSICAL Drive Shaft Assembly Precision machined shaft with two shielded ball bearings Shaft Seal Teflon /Viton TM Lipseal TM rated / 2 micron @ 0 psi (2. kg/cm 2 ) @ 400 F (204 C) Housing and Cover Injection Molded Minlon, corrosion resistant weatherproof (NEMA 4, 4X, 5) Mounting / 4 NPT Paddle Nylon, Ryton or Polysulfone Injection Molded; Insertable, 4 Vane and 2 Vane (PVC only) Shaft Extension PVC or 04 Stainless Steel Conduit Entry / 2 NPT Screw Terminals For power and switch wiring Shipping Weight 0 lb (4.5 kg) LMR8000 Rev. F

IV. MECHANICAL INSTALLATION LOCATION AND INSTALLATION The paddle and shaft are to be kept out of the direct flow of material. If the Mini Roto-Bin-Dicator is installed and contacts the flow stream, it is recommended that a protective baffle be installed on the inner wall. CAUTION: WHEN SIDE MOUNTING, THE CONDUIT OPENING SHOULD BE PLACED DOWN TO ELIMINATE MOISTURE FROM ENTERING THE UNIT FROM THE CONDUIT. MOUNTING SURFACE PREPARATION On a 4 /4 (20.65 mm) bolt circle, drill and/or tap 6 equally spaced holes in the bin wall for /6 bolts or cap screws. Bolt heads should be tack welded to bin inner wall. Insert gasket between mounting plate and bin wall. Cut a /4 diameter hole in order to insert 4-vane paddle. An insertable paddle will pass through a /4 coupling at the bin wall. 4 LMR8000 Rev. F

V. ELECTRICAL INSTALLATION WARNING: REMOVE POWER FROM THE UNIT BEFORE INSTALLING, REMOVING, OR MAKING ADJUSTMENTS. GENERAL SAFETY When using electrical equipment, you should always follow basic safety precautions, including the following: The installation and wiring of this product must comply with all national, federal, state, municipal, and local codes that apply. Do not modify any factory wiring. Connections should only be made to the terminals described in this section. DISCONNECT REQUIREMENTS FOR PERMANENTLY INSTALLED EQUIPMENT A dedicated disconnecting device (circuit breaker) must be provided for the proper installation of the unit. If independent circuits are used for power input and main relay outputs, individual disconnects are required. Disconnects must meet the following requirements: Located in close proximity to the device Easily accessible to the operator Appropriately marked as the disconnect for the device and associated circuit Sized appropriately to the requirements of the protected circuit (See specifications) CHASSIS GROUND The input power ground lead must be connected to the chassis ground terminal provided. Wire sizes must be selected such that it can safely carry the sum total of all circuits maximum amperage. WIRING Field wiring should conform to the requirements of the National Electrical Code and any other agency or authority having jurisdiction over the installation. Check nameplate for proper operating voltage Connect power wires to terminal block (TB-) located on circuit board (See Figure ) Figure : AC Circuit Board Figure 2: DC Circuit Board Connect wiring for alarm output to terminal block. (Diagram is also located in housing cover for position of terminal contacts) CAUTION: AFTER WIRING CONNECTION ARE COMPLETE, VERIFY THAT THE WIRES AT CONDUIT ENTRY ARE NOT IMPEDING THE SWITCHES FROM ACTUATING. LMR8000 Rev. F 5

Top View of Mini Roto Side Cut-away View of Mini Roto Circuit Board Control Switch (Top) Control Switch (Bottom) Permanent Magnet Synchronous Motor Torque Adjustment Spring Terminal Block Red Alarm LED (Optional) /4 NPT Process Connector Paddle Terminal Block Compression Spring (Part of Clutch) O Ring /2 NPT Conduit Connector Roll Pin Mounting Plate & 4 Vane Paddle 6 holes.22 (5.5 mm) die equally spaced on a 4.75 (20.65 mm) bolt circle Mounting Plate Material (Glass Filled Nylon) O Ring Gasket /2 NPT Conduit Connector Roll Pin 5.5 Dia. (9.7 mm).62 Dia. (9.95 mm) 4.00 (0.6 mm) 0.09 (2.28 mm) Power Pak Material (Minlon) Red LED Alarm (Optional) 0.09 (2.28 mm) approx. 4.88 (24 mm) approx..00 (25.4 mm) 2.04 (5.8 mm) approx. 4 Vane Paddle Material (Glass Filled Nylon) 6 LMR8000 Rev. F

Insertable Paddle O Ring Gasket /2 NPT Conduit Connector.62 Dia. (9.95 mm) /4 NPT Process Connector Roll Pin Insert Paddle Material (Nylon, Polysulfone, Ryton R-4) Power Pak Material (Minlon) Red LED Alarm (Optional) 4.68 (8.9 mm) approx.. (.02 mm) 5.50 (9.7 mm).0 (78.74 mm) 4 Vane Paddle with Shaft & Guard Extension O Ring Gasket /2 NPT Conduit Connector Material PVC or 04 SS.0 (25.4 mm).62 Dia. (9.95 mm) Power Pak Material (Minlon) Red LED Alarm (Optional) A /4 NPT Process Connector A Dimensions PVC Version 7.56 (92) LG SS Version 7.8 (87.45) LG Roll Pin 4 Vane Paddle Customer Insertion Length 4.0 (0.6 mm) LMR8000 Rev. F 7

4 Vane Paddle with Shaft & Guard Extension O Ring Gasket /2 NPT Conduit Connector Material PVC or 04 SS Insert Paddle Material (Nylon, Polysulfone, Ryton R-4).62 Dia. (9.95 mm) Power Pak Material (Minlon) /4 NPT Process Connector Red LED Alarm (Optional) Roll Pin.0 (78.74 mm) A Customer Insertion Length A Dimensions PVC Version 7.56 (92) LG SS Version 7.8 (87.45) LG 4 Vane Paddle with Shaft & Guard Extension.0 (76.2 mm) O Ring Gasket /2 NPT Conduit Connector Material PVC or 04 SS.62 Dia. (9.95 mm) 2.0 (04.8 mm) Power Pak Material (Minlon) /4 NPT Process Connector Roll Pin 2 Vane Paddle Red LED Alarm (Optional) A Customer Insertion Length A Dimensions PVC Version 7.56 (92) LG SS Version 7.8 (87.45) LG 50 Venture Boulevard Spartanburg, SC 2906 Tel: (800) 778-9242 Fax: (864) 574-806 sales@bindicator.com www.bindicator.com 205 All rights reserved. All data subject to change without notice. LMR8000 Rev F