Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital)

Similar documents
Solenoid Valve Manifold for use with Digital Pressure Control Coupler

Digital Manifold with Digital Hydrant Control

Transducer/Cable Assembly. Model IN64108 August 1997 Applicable additional manuals: IN64035 INSTALLATION INSTRUCTION. Installation Instruction

Digital III Fueling Vehicle Control System

3 Inch & 4 Inch Fuel Operated Bypass Pressure Control Valves. Models & 64513

Models & Inch & 4 Inch Digital Inline Pressure Control Valves SM64504

Bottom Loading & Recirculation Adapters

3 Inch & 4 Inch Digital Bypass Pressure Control Valves

Models & & 4 Air Operated Bypass Pressure Control Valves SM64501

Digital II Pressure Control Module. Model IN64235 August Installation Instructions. Applicable addition manuals:

Model INTERNAL/BOTTOM LOADING VALVES SM Maintenance & Repair Manual. July Applicable addition manuals: None

Maintenance & Repair Manual

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

Swivel Quick Disconnect To Mate Various Carter Brand Nozzles. Model SM Maintenance & Repair Manual

Model Maintenance Manual. SM44646 October Applicable additional manuals:

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Pilot-Operated Regulators

Carter Pressure Loss Compensator and Venturis. Model Model Model Model Model 64086

SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO.

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

I-BFV.KIT Butterfly Valve Gear Operator Replacement

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

B21 Series BASOTROL Gas Valve

Installation. Installation. 12. System Diagram... 10

Maintenance & Repair Manual. Misc. Male Adapters To Mate Model Nozzles And Model Couplers. SM427MISC June 1, 1993

MANUAL FOAM SYSTEM MODELS: MFA200 CLASS A FOAM MFA201 CLASS B FOAM MFA220 CLASS A and B FOAM

OPERATION AND PARTS MANUAL

Worldwide Contacts.

Pressure Sensor No Series

Flow Control Valve IOM 770-U

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Type N550 Emergency Shutoff Valves. Instruction Manual. Type N550 Emergency Shutoff Valves. Introduction. Specifications. Scope of Manual.

SM64155 Maintenance & Repair Manual

Type 644 and 645 Differential Pressure Pump Governors

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

CIRCLE SEAL CONTROLS

Maintenance Manual. Dry Break Quick Disconnect (Old Style) Model SM November 1, 2011 Applicable additional manuals: SM60427 Nozzle

Quick Disconnect To Mate Nozzle. Model SM40679 August Applicable additional manuals: SM60427 Nozzle SM Hose End Regulator

INSTALLATION & MAINTENANCE MODEL mm

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Miscellaneous Male Adapters To Mate Nozzle Models & 64348

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Type N550 Snappy Joe Emergency Shutoff Valves

Installation, Operation and Maintenance Manual

TECHNICAL INSTRUCTIONS

INSTALLATION INSTRUCTIONS

BFMM DC4A SBF EFFECTIVE AUGUST 1, 2016

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

Pressure Independent Control Series

Fisher 644 and 645 Differential Pressure Pump Governors

Instrument Valves and Manifolds

NECO Pumping Systems

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

THE INSIDE STORY OF THE QPV OR MPV:

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

Type EZR Relief Valve or Backpressure Regulator

PARTS AND INSTALLATION MANUAL

Horizontal Pre-Piped Bladder Tanks with Proportioner

Non-Valved Unisex Coupling

Flow Computer Installation

TECHNICAL MANUAL MT029

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

IFOA Integral Flow Orifice Assembly

Operation and Maintenance Manual

Vertical Pre-Piped Bladder Tanks with Proportioner

Digital II Pressure Control System

Fisher 4194S Differential Pressure Controllers

Pressure Independent Control Series

DEMA MIXRITE PROPORTIONING PUMP MODELS 574 & CL & 575CL FOR CORROSIVE LIQUID CHEMICALS INSTALLATION INSTRUCTION.

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

PRO-BALANCE 1 1/4 IN. BRASS MANIFOLD. Product Instructions

I & M MK96 & MK96C. Ideal Installation. Start-Up. Maintenance PROTECT VALVES WITH LINE STRAINERS

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Adjustable Differential Relay A1

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

TECHNICAL DATA 1-1/2 (dn40)

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance

Model MTB-ASME Horizontal Pre-Piped Bladder Tanks

Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

Colt Series C400, C500

Model RM-1 Riser Manifold Commercial and Residential General Description

Bettis M11 Manual Hydraulic Override System Operating Instructions for HD, T, and G Series Pneumatic and Hydraulic Actuators

Whisper Pump Service and Repair Guide

Catalog HY /US Flow Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE LPM/GPM BAR/PSI

Hydrant Valve In Accordance With Bulletin API Model SM Maintenance & Repair Manual. January 2011

INSTRUCTION AND MAINTENANCE MANUAL GFH45 PRESSURE REGULATOR

PRESSURE REDUCING CONTROL VALVE

HKV 1 1/4 in. Brass Manifold Product instructions. Construction Automotive Industry

SERIES 8100 HAND-OPERATED PRESSURE CALIBRATION UNITS

Common Rail Injector

Transcription:

IN64124 August 15, 1997 Aerospace Group Conveyance Systems Divison Carter Brand Ground Fueling Equipment Applicable additional manuals: Installation Instructions Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital) Model 64124 Model 64080 Model 64110 Model 64002 Model 64082

SUMMARY OF REVISIONS DATE OF CHANGE PARAGRAPH/ PAGE REV LTR E.O. NO. REVISION 8/15/97 Page 1 A Revised to release under EO APPROVE D BY - 2 -

TABLE OF CONTENTS Para. Description Page 1.0 Scope ------------------------------------------------------ 4 2.0 Equipment Supplied by Customer--------------------- 4 3.0 General Description ------------------------------------- 4 4.0 Installation ------------------------------------------------ 5 4.1 Mounting on the Vehicle ------------------------------- 5 4.2 Air Bleeding --------------------------------------------- 11 4.3 Electrical Connections --------------------------------- 12 4.4 Pressure, Opening and Closing Control Setup------ 12 4.5 Installation/Adjustment of 64067 Maximum Rate of Flow Pilot -------------------------------------- 14-3 -

1.0 SCOPE These installation instructions have been developed for use in mounting Carter brand Model 64124/64080/64110 Inline Valves or 64060/64120 Bypass Valves on any refueling vehicle. There are several optional versions of the 64110 In-line Valve and all versions are covered in these instructions except for the digital version which is covered in separate manual, IN64050. These instructions do not cover all requirements for such an installation which might be dictated by other authorities which have jurisdiction over the use of your vehicle. The responsibility for proper final installation configuration is yours. Consult with the local airport authority or corporate authority for further information. 2.0 EQUIPMENT SUPPLIED BY CUSTOMER The following is a listing of the required equipment supplied by the customer on the refueling vehicle. All tubing needed to connect the valve to the other components within the system. On the basic 64110 (no options) the valve is furnished less the solenoid valve and opening and closing orifices. Customer must furnish needle valves to achieve an adjustable opening and closing time. All mounting hardware required. 3.0 GENERAL DESCRIPTION The face-to-face distance of the ANSI flanged versions of the 4 inch is 9.25 inches while the 3 inch measures 8.0 inches. The various valves covered by these instructions are described below. 64124 and 64080 - Air Set Pressure Control Valves - These valves are direct acting units requiring an air reference pressure set at approximately 25 psi greater than the desired control pressure. Typically they are connected to a Venturi to provide compensated pressure control at the nozzle(s). 64002 and 64082 - Air Set By-pass Pressure Control Valve - These units are installed as a by-pass control to provide compensated pressure to the nozzle(s). They are essentially the same as the 64124 and 64080 except for a lighter spring and the air reference pressure is used to normally close the valve. As the nozzle pressure increases, these units open to allow more flow to by-pass the pump reducing the control pressure. The bias (difference between the air reference pressure and the desired control pressure) for these units is zero psi, that is the air pressure is set at the desired control pressure. The B option for both valves provides an additional control that will allow the unit to open when the pump outlet pressure exceeds the setting of the control. 64110 - This unit is offered in four varieties as noted below. 64110 (no option) - A basic on-off valve for use as a deadman only type valve. This unit requires the addition of a three-way, two position solenoid valve and two needle valves by the customer to effect a proper deadman shutoff valve with adjustable

opening and closing time controls. NOTE: It might be less expensive to utilize two two-way solenoid valves in lieu of a single 3- way. In that case following the wiring diagram for the 64110A3. 64110A1 or 64110B1 - Digital Pressure Control Valve - This unit is covered in IN64050 and will not be discussed further in this document. 64110A2 or 64110B2 - Fuel Operated Pressure Control Valve - This unit performs the pressure control function in a system where air is not available and incorporates either 12 or 24 VDC solenoid controls for the deadman function. The pressure control function has a simple adjustment. 64110A3 or 64110B3 - Fuel Shutoff Valve - The same as the basic unit except either 12 or 24 VDC solenoid controls and integral orifices are furnished to result in a deadman valve with proper controlled opening and closing. All of the various units above are available with ANSI flanges or Victaulic inlet and outlet as desired. See Bulletin 64124 for additional ordering information. 4.0 INSTALLATION 4.1 Mounting on the Vehicle 4.1.1 All of the subject units MUST be mounted HORIZONTALLY on the vehicle and all, except for the 64110 (basic unit) and 64110A(B)2 Shutoff Valves, mounted with the Solenoid Valve assembly or the ports labeled D and C (in the case of older 64124 Valves these ports may be labeled AIR and VENT ) on bottom of the unit (at the 6:00 o clock position). The two shutoff valve types (64110 and 64110A(B)2) should be installed with the solenoid valves or ports C and D orientated on the top of the valve (at the 12:00 o clock position). Failure to comply with this requirement will result in poor performance of the units. 4.1.2 If clearance around the 64110, with the solenoid or regulator package, is a severe problem, the solenoid valve assembly can be removed from the valve and mounted near the valve with new connections fabricated to appropriately connect the solenoid valve assembly to the 64110 housing. If the fittings are removed from the units and re-installed, DO NOT USE TEFLON TAPE. Use Loctite 59231 Pipe Sealant with Teflon for sealing pipe threads. CONSULT WITH CARTER FOR DETAILED INFORMATION REGARDING THIS BEFORE TAKING ACTION. 4.1.3 The 64124/64080/64110A(B)2 will normally be utilized with a Venturi to effect proper compensated pressure control at the nozzle. Otherwise a remote pressure sensing port is required to achieve a modicum of proper pressure control. The ports or connections to the various valves are to be connected to other locations on - 5 -

the refueling vehicle as noted in the table and figures below. PART NUMBER PORT CONNECT TO COMMENTS 64124/64080 D 3/8-64124/64080 Continued. C 1/4 - B 1/4 - A 3/8-64002/64082 D 3/8 - Air Reference Pressure Regulator Slop Tank, main tank on refuelers or inlet side of the pump (outlet of the by-pass valve if present). No connection necessary, this is an air bleed port. Port must be plugged. Fuel sense point, either a Venturi or static sense point. A 3-way air operated valve is installed in this port offering three other ports to which the following installations are to be made by the OEM: A - Connect to the main line from the outlet of the pump. B - Connect to air reference pressure regulator and to the fitting in port B on body. C - Connect to Venturi or sense port. Port may be labeled AIR on older valves. See Figure 1 below. If the port is left open leakage will eventually become apparent from this vent signifying that the seals within the valve need repairing. The valve is delivered with a check valve/orifice installed in the port in the body but there is an extended port for installation of the fuel sense connection. See Figure 2 below. - 6 -

FIGURE 1-64124/64080 IN-LINE CONTROL VALVE PART NUMBER PORT CONNECT TO COMMENTS C 1/4 - B 1/4 - A 1/4 - Slop Tank, main tank on refuelers or inlet side of the pump (outlet of the by-pass valve if present). Connect this extended port on all units, to the regulated air reference pressure. This port is plugged on basic units. On option B units, a controller is installed in this port. The port in the controller (1/4-18 NPT) is to be connected to the main line from the outlet of the pump. If the port is left open leakage will eventually become apparent from this vent signifying that the seals within the valve need repairing. See Figure 2 below. See Figure 2 below. - 7 -

FIGURE 2 - BY-PASS CONTROL VALVE PART NUMBER PORT CONNECT TO COMMENTS 64110 (basic) D 3/8 - NPT Connect to common port of 2-position, 3- way solenoid valve. See Figure 3 below. Connect normally closed port of 3-way solenoid valve through an adjustable needle valve to port provided in inlet of valve body. Connect normally open port of solenoid valve through an adjustable needle valve to slop tank, fuel storage tank or upstream of fuel pump. The needle valves will be used to provide adjustable opening and closing times for the unit. - 8 -

PART NUMBER 64110 (basic) Continued. PORT CONNECT TO COMMENTS C & A 1/4 - B 1/4-18 NPT Furnished plugged. Air breather furnished. FIGURE 3-64110 (BASIC, NO OPTIONS) SHUTOFF VALVE (Customer furnishes solenoid, opening and closing orifice controls) PART NUMBER PORT CONNECT TO COMMENTS 64110A2 or B2 D Used in Carter installation connecting to solenoid valves and relief valve. - 9 - See Figure 4 below. The port left open in the relief valve is to be connected to the inlet side of the pump. The open port in the solenoid manifold is to be connected to the slop tank, storage tank or inlet side of the pump.

PART NUMBER PORT CONNECT TO COMMENTS B & C A 3/8 - Plugged by Carter Connect port in check valve to Venturi or fuel sense port. FIGURE 4-64110A(B)2 FUEL SET PRESSURE CONTROL VALVE PART NUMBER PORT CONNECT TO COMMENTS 64110A3 or B3 D A & C B Used in Carter installation connecting to solenoid valves. Plugged by Carter Breather installed by Carter See Figure 5 below. The open port in the solenoid manifold is to be connected to the slop tank, storage tank or inlet side of the pump. - 10 -

FIGURE 5-64110A(B)3 FUEL SHUTOFF VALVE (Furnished with integral solenoid controls) 4.2 Air Bleeding 4.2.1 64124/64080 In-line Valves - Once the physical installation is complete and the vehicle is filled with fuel, upon first pressurization by the pump, the plug in port B must be loosened to bleed air from the fuel sense line and from the internal cavity of the 64124/64082. Cycling the deadman on and off will cause the valve to open and close and facilitate bleeding. 4.2.2 64002/64082 By-pass Valves - The fittings connected to the C port on the 3-way valve (one connected to the sense line) must be loosened to effect bleeding air from the line. Cycling the deadman will facilitate the operation. On valves with the B option the fitting connecting the controller and the main line from the pump should also be loosened to bleed air from the line. 4.2.3 64110A(B)3 Shutoff Valves - If possible, loosen the unused fitting (plug) on the end of the Solenoid Valve Manifold Block as a bleeding point. Alternatively, loosen the fitting on the side of the Manifold Block next to the shorter of the two Solenoid Valves to which the stainless steel tubing is attached. With pressure applied to the inlet of the valve, activate the Deadman Control to apply pressure to this line. Air will escape from the loosened fitting. Fuel will soon appear. 4.2.4 64110 (basic) Shutoff Valve - Loosen the fitting installed in port D. - 11 -

With pressure applied to the inlet of the valve, activate the Deadman Control to apply pressure to the line. When most of the air is bled, slowly tighten the fitting to build pressure within the control cavity of the valve. This will cause the valve to open. After the valve has opened, re-loosen the fitting. If loose enough, the valve will stroke closed and exhaust some trapped air from the internal control cavity. Repeat this step until you are satisfied that all the air is removed from the control line and from the control cavity of the valve. 4.2.5 64110A(B)2 Fuel Set Pressure Control Valve - Bleed the same as for 64110A(B)3 above. In addition bleed the same as for 64124 above. 4.3 Electrical Connections 4.3.1 64110 Valves furnished with electrical deadman control - The Solenoid Valve assembly has two (2) electric connectors attached to the two Solenoid Valves (one per Solenoid Valve). These connectors have ½ female NPT ports for connecting a conduit fitting, or other style fitting, for carrying incoming wires. 4.3.2 Remove these connectors by removing the single screw at the center of each connector. With the screw removed (whether or not the connector has been pulled from the valve body) the cover will come off of the connector revealing the wiring connection points within the connector. 4.3.3 There are three connection points within the connector. The center one, marked GND, will not be used in this installation. Two wires will be used to connect each solenoid valve to one side of the battery while the other two are connected to the deadman switch as shown in Figure 4 & 5. (That are four (4) wires total for each 64124/64082.) THE TWO WIRES CAN BE CONNECTED TO THE TWO POINTS WITHIN THE CONNECTOR IN ANY ORDER. The solenoid valve will work the same in either case. 4.3.4 To connect the two wires, strip about 3/16 inch of insulation from the end of the wires, loosen the center screw of each connection point such that the stripped wire will enter the side of the connections point, insert the wire, and tighten down the center screw to clamp the bare wire in place. 4.4 Pressure, Opening and Closing Control Setup 4.4.1 64124/64080 Air Set In-line Valves - The only operation needed to achieve the correct pressure control is, once the system is connected to a flow test rig, is to adjust the air reference pressure to 25 psi above the desired control pressure, establish the desired optimum flow rate for the system, adjust the valve downstream of the nozzle connection until the valve begins to control. The resultant control pressure should be that desired. The closing time is adjustable by an orifice screw located in port D, the air reference port. It is necessary, after checking the closing time to disconnect the air line and remove the fitting to get to the adjustment. Counter-clockwise turning of the orifice screw with decrease the closing time and overshoot. It should be adjustable over a range of from 2-5 seconds. Refer to Service Manual - 12 -

SM64124 or SM64080 for more information on testing the units. 4.4.2 64110A(B)2 Fuel Set In-line Valves - The system is to be attached to a flow test rig. Activate the deadman switch to open the valve and establish flow for at least 2 minutes to bleed the system. The fuel control pressure is adjustable by opening or closing the knob on the small relief valve mounted on the solenoid valve manifold (bottom of the unit). Counter-clockwise movement of the relief valve knob will reduce the pressure control level. Be sure that the valve downstream of the nozzle on the test rig is shut down sufficiently to cause the valve to control. It is suggested that a low flow rate (150 gpm or so) be set up at first to assure the need to control. If the system is wide open the valve will never sense the need to control and will remain wide open. Fixed orifices are supplied to provide the industry standard opening and closing times of from 5-10 seconds for the former and 2-5 for the latter 4.4.3 64110A(B)3 Shutoff Valves - Fixed orifices are supplied to provide the industry standard opening and closing times of from 5-10 seconds for the former and 2-5 for the latter. 4.4.4 64110 basic Shutoff Valve - OEM is to furnish orifices in the form of adjustable needle valves as mentioned earlier. The needle valve connected directly to the slop tank primarily controls the closing time and the one in the inlet of the valve that is connected to the solenoid valve primarily controls the opening time. Adjust each to achieve the desired times. Adjustment of one will have a slight affect upon the other time. Trial and error is the only way to achieve this adjustment. 4.4.5 64002/64082 By-pass Control Valves - Aircraft Control Pressure - Apply air reference pressure equal to the amount of desired control pressure. It is suggested that a low flow rate into the test rig (150-300 gpm or so, depending upon valve size) be set up at first to assure the need to control. If the system is wide open the valve will never sense the need to control and will remain closed. On option B units, the pump outlet pressure at which the unit will open can be varied using the following method: a). Loosen the locking nut on the Controller Assembly mounted in Port A. b). Turn the hexagon body clockwise to its stop. c). Turn the hexagon body counter-clockwise one full rotation. d.) With the pump on, open the deadman to establish flow through into the test rig, then keeping the deadman activated, close the flow with a valve downstream of the inline valve. The by-pass valve will go fully open. e). Turn the body counterclockwise to achieve the desired relief pressure at the outlet of the pump. f). Tighten the lock nut. 4.5 Installation/Adjustment of 64067 Maximum Rate of Flow Pilot - 13 -

The 64067 Rate of Flow Pilot can be used only with Carter 64124/64080 Air Reference In-line Control Valves and 64110A2 Fuel Set Control Valve. 4.5.1 Installation - Refer to Figure 6. The choice of the locations for obtaining the 2-10 psi differential may not be at the Venturi as shown. It is important that no less than 2 nor more than 10 psi differential be used. FIGURE 6-64067 INSTALLATION DO NOT USE TEFLON TAPE on any fittings.. Use Loctite 59231 Pipe Sealant with Teflon for sealing pipe threads. 4.5.2 Bleeding - Bleed as noted in 64124 above plus loosen the fittings installed in ports A, B, C & E of the 64076 during the deadman activating cycling process. 4.5.3 Adjustment of rate of flow - In a system capable of producing a flow rate greater than the amount at which the rate is to be limited, establish maximum flow capable. Note screw driver shown in Figure 4. Clockwise turning of the screw will reduce the rate of flow at which the unit will control. Allow time for the system to stabilize after each adjustment. Continue adjustment until desired flow rate is achieved. - 14 -

Aerospace Group Conveyance Systems Division 9650 Jeronimo Rd Irvine, CA 92618 Ph (949) 452-9500 Fax (949) 452-9992