LEGAL REQUIREMENTS The Occupational Health and Safety Act (Act 85 of 1993) requires emergency evacuation lighting for workplaces without natural light. It is therefore illegal not to have emergency evacuation lighting in work areas or public places where no natural light is present. A minimum of 0.3 lux at the floor level is required to enable evacuation but a level of not less than 20 lux is required for moving machinery or where it is necessary to shut down plant or processes where dangerous materials are present. The act also requires that the emergency lighting must be activated within 15 seconds and the emergency lighting must be kept in good working order and tested at intervals of not more than three months.all emergency lighting must comply with the following requirements of SABS 1464 Part 22: Classification: Emergency luminaires shall have labelling to indicate whether they are self contained or centrally supplied, maintained or non-maintained, have test devices and emergency duration. The following symbols shall be used: X = self-contained, Z = centralsupply, 0 = non-maintained, 1 = maintained, 6 = satellite, A = including test devices, B =including remote rest mode, C = including inhibiting mode, D = high risk task area lighting, 10 = ten minutes duration, 60 = one hour duration, 120 = two hours duration, 180 = three hours duration. Marking: Luminaires shall be clearly marked with rated voltage, correct replacement lamps and maximum ambient temperature. Emergency lamp holders in combined luminaires shall be identified by a green dot. A label on the battery pack shall indicate replacement battery details, battery manufacture and commissioning date. An instruction leaflet shall be provided detailing test facilities and test procedures. Electrical safety: Requirements of SABS 598-1 shall apply. Endurance and thermal testing: The unit must satisfy various soak and cycle testing to ensure reliability. Battery charge and discharge: The batteries must be charged within 24 hours, deep battery discharge must be prevented and high temperature batteries must be used in self contained emergency luminaires. Photometric performance: The luminaire shall provide rated lumen output claimed by the manufacturer during emergency mode for 1 minute after failure of supply and continuously to the end of rated duration. In other words, if the unit is marked as a 50% light output then the emergency light output must be 50% of the mains light output. Pg7.1
PEM6 LED Emergency exit PEM6-LED 375 147 25 LED 2 hour emergency duration Slimline Satisfies all SABS specifications Long life LED s All SABS legends available Energy saving PEM7 LED Emergency exit PEM7-LED 375 147 25 LED 5 hour emergency duration Slimline Satisfies all SABS specifications Long life LED s Energy saving Pg7.2
PEM8 Emergency exit PEM8-19SS 550 355 130 1 x 9w CFL PEM8-29SS 550 355 130 2 x 9w CFL PEM8-19DS 550 355 130 1 x 9w CFL PEM8-29DS 550 355 130 2 x 9w CFL /ECG - Electronic control gear An economical range of beveled edge exit signs. Available with single or double side. Available with different pictograms. Standard with conventional control gear PEM2 Standard with EXIT pictoral Ceiling or wall mounted Toughened glass lense SMC-fiberglass frame Emergency exit PEM2EXIT-29PL 310 310 65 2x 9w PEM2MAN-29PL 310 310 65 2x 9w /ECG - Electronic control gear /EMG - Emergency gear /RD - Running man down exit /RL - Running man left exit /RR - Running man right exit /DS - Double sided mode /NM - Non-maintained mode Pg7.3
PIB1 PIB2 PIB1-1HR 1 Hour Fluorescent up to 65w PIB1-3HR 3 Hour Fluorescent up to 65w Figures below for 1hr units (3hr units figures in brackets) Lamp Type Light Output Battery Current Duration T8 : 58w 12% (11%) 1.3A (1A) 1.4 (4) hours T8 : 36w 18% (15%) 1.1A (0.9A) 1.6 (4.4) hours T8 : 18w 20% (22%) 0.7A (0.7A) 2.6 (6.1) hours T8 : 10w 30% (32%) 0.6A (0.5A) 3 (8) hours T5 : 8w 40% (45%) 0.7A (0.6A) 2.6 (6.8) hours TC-DEL: 26w 32% (18%) 1.2A (0.8A) 1.5 (4.7) hours TC-DEL: 18w 29% (26%) 1A (0.8A) 1.8 (4.7) hours TC-DEL: 13w 36% (30%) 1A (0.6A) 1.8 (6.8) hours TC-DD : 28w 25% (15%) 1.2A (0.7A) 1.5 (6.1) hours TC-L : 18w 23% (19%) 0.7A (0.6A) 2.6 (6.8) hours TC-EL : 11w 43% (42%) 0.9A (0.6A) 2 (6.8) hours TC-EL : 9w 36% (31%) 0.6A (0.5A) 3 (8) hours TC-EL : 7w 38% (44%) 0.7A (0.5A) 2.6 (8) hours Note: The emergency lighting duration and light output may vary due to ambient temperature, cell type and lamp manufacturer. The PIB1emergency control units cover all axial fluorescent lamps as well as four pin compact types from 6 to 65 Watts. Self testing pack PIB2-1HR 1 Hour Fluorescent up to 65w PIB2-3HR 3 Hour Fluorescent up to 65w Lamp Type Light Output Battery Current Duration T8 : 58w 15% 1.2 A 1.7 (3.3) T8 : 36w 20% 1.1 A 1.8 (3.6) T8 : 18w 44% 1.1 A 1.8 (3.6) T5 : 8w 71% 0.9 A 2.2 (4.4) TC-DEL: 26w 27% 1A 2 (4) TC-DEL: 18w 30% 1A 2 (4) TC-DEL: 13w 38% 0.8 2.5 (5) TC-DD : 16w 38% 1A 2 (4) TC-DD : 26w 25% 1A 2 (4) TC-L : 18w 38% 1A 2 (4) TC-EL : 9w 58% 0.9 2.2 (4.4) This emergency lighting control unit incorporates a self testing facility that exercises batteries and establishes lamp condition on a regular basis. Automatic tests are conducted on a weekly basis with full functional tests every month. The weekly tests, of two minutes duration, establish battery and lamp condition whilst the monthly tests last 40 minutes in order to remove battery memory effects. System faults are reported via both audible and visual means Pg7.4
PIB3 PIB3-1HR 1 Hour 36w & 58w The PIB3 emergency control units achieve 50% light output for 1 hour on 36w and 58w linear fluorescent tubes PIB4 PIB4-1HR 1 Hour 36w & 58w The PIB4 emergency control units achieve 100% light output for 1 hour on 36w and 58w linear fluorescent tubes PIB5 PIB5-1HR 1 Hour 2 Pin Compact fluorescent The PIB5 emergency control units are for 1 hour duration on compact fluorescent lamps. The inverter s small dimensions make it possible to mount in smaller luminaires LIGHT OUTPUT: 26w - 40% 11w - 70% 18w - 50% 9w - 80% 13w - 60% 7w - 100% Pg7.5
PIB6 PIB6-1HR 1 Hour LV & 8w Fluorescent The PIB6 System can be connected to six 8W fluorescent lamps, or two 12V 20W halogen lamps or one 12V 50W lamp Photometric data available on request PIB7 PIB7-1HR 1 Hour 20w & 50w LV The PIB7 has beeen designed to fit through the downlight hole in to the ceiling cavity, the unit can be used in maintained mode (where the normal Lv supply, fixed or dimming, is routed through the unit). Pg7.6