LIBERTY APPROVED OIL BURNERS AND SPECIFICATIONS. Supplemental Installation and Operating Instructions OIL-FIRED WATER AND STEAM BOILERS / NO.

Similar documents
Light oil - kerosene burner

Oil - kerosene burner

BURNER SERVICE MANUAL 37

Routine Burner Service

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

701CRD/801CRD Oil Burners

7. SERVICING AND COMPONENT ADJUSTMENTS

BOILER RATINGS. Net Ratings Oil Gas

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

Updated technical data can be found in this document, supplemented by the Riello BX Burner Manual regarding commissioning checks and adjustments.

Kerosene - oil burner

OIL FIRED FURNACE REPLACEMENT PARTS MANUAL FLF085D36C FLF110D48C. Models: Contents. General Notes. Important

REPLACEMENT PARTS MANUAL

Installation- and maintenance instruction BENTOFLEX ST133KA/K

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

Installation- and maintenance instruction B20KAV/KV

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

Installation- and maintenance instruction B20KA/K

SPARE PARTS MANUAL VAL HEATERS

MAINTENANCE SCHEDULE

Repair Manual. Modular Direct Steam Kettle

Installation- and maintenance instruction BENTOFLEX ST 108 PL

OLR Product Specifications

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

Installation- and maintenance instruction B20KA/K

Installation- and maintenance instruction ST120 S75/21

XL9 E-S Serial number N for XL9 E Edition 2005

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG)

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

Spareparts VAL 6-1 STEP KB - KL

Installation- and maintenance instruction B20K-2

OIL BURNER NOZZLES

Installation- and maintenance instruction BENTOFLEX ST120KAV

Installation- and maintenance instruction B80-2/3

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION

Energysaver 559FT. Rinnai New Zealand Limited Page 1 of 6 Rinnai Energysaver 559FT Spare Parts: 01-11

XL9E-S Edition2005. Serial numbern forxl9e

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

Mobile Diesel Heaters TOR / MIR Technical Training Course

PARTS LIST GAS TILTING SKILLETS MODELS: GLTS-30 GLTS-40

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

1.1.5 Reassembly of Cylinder Block

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

Installation Manual. English. French

PRESS P/N - P/N ECO SERIES

AEROMOTIVE Part # /2 4.6L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

HVF110, 210, 310, 410HD

OMNI Universal Ignitor

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

NUTONE RANGE HOOD NTM SERIES

FSG175 FENCE STAPLE GUN

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION

Solid-state ignition Beckett CleanCut fuel pump with oil valve Air tube 2-3/4" UL-recognized

OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG)

FUEL OIL BURNERS. By Mark Butterfield March 09

Installation- and maintenance instruction BENTOFLEX ST133K

Infrared oil heater. Model. Type. KBE5S for 120V 60Hz KBE5L for 120V 60Hz KBE5L 2-step for 120V 60Hz KBE1S for 230V 50Hz

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

OIL BURNERS - 115V / 230V

TECHNICAL SERVICE BULLETIN

B14 AAA FINE FINISH SERIES PUMP OUTFIT

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA

Hydraulic Pumping System

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

INSTALLATION INSTRUCTIONS

Specifications PERFORMANCE GENERAL SELLER. Specifications. Discharge Volume 3.6 GPM / 13.2LPM. Pump Head Pressure psi / 208 bar

M-SERIES DIAPHRAGM COMPRESSOR REBUILD KIT

B14 AAA FINE FINISH SERIES PUMP OUTFIT

RAYPAK ILLUSTRATED PARTS LIST

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

SEE M1, M2: HEAT EXCHANGER ASSEMBLY 27 SEE M2: ELECTRIC PARTITION ASSEMBLY PART NO REV B (REF EH-M2-10PL) * ITEM NOT SHOWN

SPARE PARTS LIST. for. Infrared oil heater. Model. Type. EPX5 for 120V 60Hz. May, 2017

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A

SEE M1, M2: HEAT EXCHANGER ASSEMBLY SEE M2: ELECTRIC PARTITION ASSEMBLY PART NO REV C (REF EH-M2-10PL) * ITEM NOT SHOWN

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

User s Manual D-Series Blowers and Exhausters

AEROMOTIVE Part # Ford 5.4L GT500 Shelby Mustang Fuel Rail Kit INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

COBB Tuning Catback Exhaust System MAZDASPEED3

AEROMOTIVE Part # L Ford F L Ford Expedition L Ford F-250 Super Duty INSTALLATION INSTRUCTIONS

MGM Brakes Service Manual

Parts and Accessories

RAYPAK ILLUSTRATED PARTS LIST

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Solid state ignition Beckett CleanCut fuel pump with oil valve Air tube 2-3/4" UL recognized. Beckett Burner Chart

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

RAYPAK ILLUSTRATED PARTS LIST

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

Replacement parts. Table 6. Item Description Part no. A Regular front section

OIL FIRED UPFLOW FURNACE SPECIFICATIONS


OPERATION MANUAL. TWE Pin Welder. Model TWP-2 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330) Revision 2.

SERVICE BULLETIN No. 1088

Transcription:

LIBERTY II OIL-FIRED WATER AND STEAM BOILERS / NO. 2 OIL Supplemental Installation and Operating Instructions APPROVED OIL S AND SPECIFICATIONS FOR KNOCKED-DOWN BOILERS AND KNOCKED-DOWN BOILER/ UNITS ONLY NO. 2 FUEL ONLY Approved Oil Burners and Specifications For assembly and parts information for knocked-down boilers and knocked-down boiler/burner units, refer to Publication No. LD-41K. For installation and operating instructions see publication LD-43K. Use of an oil burner not approved by Slant/Fin voids the Liberty boiler warranty. CONTENTS PAGE Burner and Nozzle Specifications for: Table 1: Slant/Fin supplied burners for knocked down boiler/burner units......................2 Table 2: Field supplied burners for model LD-30 knocked down boilers........................3 Table 3: Field supplied burners for model LD-40 knocked down boilers........................4 Table 4: Field supplied burners for model LD-50 knocked down boilers........................5 Burner Adjustment Illustrations: Beckett, Carlin & Wayne Burners.................6 ABC........................................7 Riello.......................................8 Part No. 43-0293 Printed in U.S.A 402 Publication No. LD-42KB Revision C

Table 1: Specifications for Slant/Fin supplied burners only for boiler/burner units with full combustion chambers. BOILER FIRING RATE SIZE NOZZLES ANGLE & TYPE LD-20 Beckett F.O..75.75 80B DELAVAN 100 8 CLOSED N.A WU AFG LD-20 Carlin Wrapped.75.75 70A DELAVAN 100 BLANK 45% 1-2 WU 99FRD Shield LD-30 Beckett AFG F-4S 1.10 1.10 80 SS HAGO WU &SU 80 W DELAVAN 100 9 CLOSED N.A. LD-30 Beckett AFG F-4S 1.25 1.25 80 SS HAGO WU 80 W DELAVAN 100 10 1 N.A. LD-30 Carlin 99FRD Wrapped 1.10 1.10 70 SS HAGO WU & SU 84467, See note 1 Shield 70 W DELAVAN 100 BLANK 40% 4 LD-30 Carlin 99FRD Wrapped 1.25 1.25 70 H HAGO WU 84467, See note 1 Shield 70 A DELAVAN 100 BLANK 50% 5 LD-40 Beckett AFG F-120 1.60 1.50 80 SS HAGO WU & SU 80 W DELAVAN 113 10 1/2 N.A. LD-40 Beckett AFG F-120 1.80 1.75 80 SS HAGO WU 80 W DELAVAN 105 10 3 N.A. LD-40 Carlin 99FRD Standard 1.60 1.50 70 SS HAGO WU & SU 84459, See note 2 70 W DELAVAN 113 FULL 40% 5 LD-40 Carlin 99FRD Standard 1.80 1.75 70 SS HAGO WU 84459, See note 2 70 W DELAVAN 105 FULL 30% 8 LD-50 Beckett AFG F-164 2.10 2.00 80 SS HAGO WU & SU 80 W DELAVAN 110 10 2 N.A. LD-50 Beckett AFG F-164 2.35 2.25 80 SS HAGO WU 80 W DELAVAN 109 10 3 N.A. LD-50 Carlin 102CRD-3 Standard 2.10 2.00 70 SS HAGO WU & SU 87312, See note 3 70 W DELAVAN 110 FULL 20% 4 LD-50 Carlin 102CRD-3 Standard 2.35 2.25 70 SS HAGO MFR. OIL PUMP PRESSURE (PSIG) APPROXIMATE S * SHUTTER * BAND * NOTE: 1. S.S. wrapped shield air-tube assembly 1051A 160B Air shutter blank part # 1007-1 Dual slotted air band part # 1008 See figure 2B. 2. Standard air-tube part # 1051-5. (Figure 2A) 3. Standard air-tube and flange assembly part number 71142. * To see how adjustments are made on CARLIN & BECKETT burners, see illustrations only on pages 11 & 12 of publication LD-40, but use values in table 1, above. All pump pressures may be 100 PSI but will fire at a slightly lower rate. WU = water units SU = steam units 2

Table 2: Field supplied burners for knocked down boilers with Slant/Fin supplied full combustion chambers. BOILER FIRING RATE SIZE NOZZLES ANGLE & TYPE LD-20 Beckett F.O..75.75 80B DELAVAN 100 8 CLOSED* N.A WKD AFG LD-20 Carlin Wrapped.75.75 70A DELAVAN 100 BLANK 45% 1-2 WKD 99FRD Shield LD-30 Beckett AFG F-6 1.10 1.10 80 W DELAVAN 100 8.5* CLOSED* N.A. WKD &SKD LD-30 Beckett AFG F-6 1.25 1.25 80 SS HAGO WKD 80 B DELAVAN 100 10* 1* N.A. LD-30 Carlin 99FRD Wrapped 1.10 1.10 70 SS HAGO WKD &SKD 84467 Shield 70 W DELAVAN 100 BLANK 40%* 4* See note 1 Kit # 65524 LD-30 Carlin 99FRD Wrapped 1.25 1.25 70 H HAGO WKD 84467 Shield 70 A DELAVAN 100 BLANK 50%* 5* See note 1 Kit # 65524 LD-30 Beckett AFG F-4S 1.10 1.10 80 SS HAGO WKD &SKD 80 W DELAVAN 100 9* Closed* N.A. LD-30 Beckett AFG F-4S 1.25 1.25 80 SS HAGO WKD 80 W DELAVAN 100 10* 1* N.A. LD-30 ABC FC-134 1.10 1.10 60 SS HAGO 100 NONE 3/4 3/16 WKD & SKD LD-30 ABC FC-134 1.25 1.25 70 SS HAGO 100 NONE 3/4 3/8 WKD 70 W DELAVAN LD-30 Riello F-5 1.10 0.85 70 ES HAGO WKD & SKD 40 Series 70 B DELAVAN 160 3.5 N.A. 2 LD-30 Riello F-5 1.25 1.00 70 ES HAGO WKD 40 Series 70 W DELAVAN 160 4 N.A. 2. LD-30 Wayne HS 1.25 1.25 80 A DELAVAN 100 3.5 2 3 WKD Blue Angel 10 Vane damper MFR. OIL PUMP PRESSURE (PSIG) APPROXIMATE S SHUTTER BAND NOTE: 1. S.S. wrapped shield air-tube assembly 1051A 160B Air shutter blank part # 1007-1 Dual slotted air band part # 1008. See figure 2B. * To see how adjustments are made on CARLIN & BECKETT burners, see illustrations only on pages 11 & 12 of publication LD-40, but use values in table 2, above. Wayne blue angel part # 100-393 flame lock Wayne blue angel part # 100-420 air cone with no holes WU = water units SU = steam units 3

Table 3: Field supplied burners for knocked down boilers with Slant/Fin supplied full combustion chambers. BOILER FIRING RATE SIZE NOZZLES ANGLE & TYPE LD-40 Beckett AFG F-60 1.60 1.50 80 W DELAVAN 113 10* 1-1/2* N.A WKD & SKD LD-40 Beckett AFG F-12 1.60 1.50 80 SS HAGO WKD & SKD 80 A DELAVAN 113 10* 0* N.A. LD-40 WKD Beckett AFG F-12 1.80 1.75 70 A DELAVAN 105 10* 1-1/2* N.A. LD-40 Beckett AFG F-120 1.60 1.50 80 SS HAGO WKD & SKD 80 W DELAVAN 113 10* 1/2* N.A. LD-40 Beckett AFG F-120 1.80 1.75 80 SS HAGO WKD 80 W DELAVAN 105 10* 3* N.A. LD-40 Carlin 99FRD Wrapped 1.60 1.50 70 SS HAGO WKD &SKD See Note 1 Shield 70 A DELAVAN 105 FULL 50%* 8* Kit # 65524 LD-40 Carlin 99FRD Wrapped 1.80 1.75 70 SS HAGO WKD See Note 1 Shield DELAVAN 100 10* 1* N.A. Kit # 65524 LD-40 Carlin 99FRD Standard 1.60 1.50 70 SS HAGO WKD & SKD 84459, See note 2 70 W DELAVAN 113 FULL 30% 5* LD-40 Carlin 99 FRD Standard 1.80 1.75 70 SS HAGO WKD 84459, See note 2 70 W DELAVAN 105 FULL 30%* 8* LD-40 ABC FC-134 1.60 1.50 60 ES HAGO 113 NONE Full & 1/2 WKD & SKD 70 W DELAVAN 2-3/4 LD-40 ABC FC-234 1.80 1.75 70 ES HAGO 105 NONE Full & 1/2 WKD 70 B DELAVAN. 1/2 LD-40 Wayne HS 1.60 1.50 70 A DELAVAN 113 5 2 2 WKD & SKD Blue Angel 10VANE damper LD-40 Riello F-10 1.60 1.25 60 ES HAGO WKD & SKD 40 Series 70 B DELAVAN 160 2.5 N.A. 1 LD-40 Riello F-10 1.80 1.35 70 ES HAGO WKD 40 Series 70 B DELAVAN 180 3.5 N.A. 1 MFR. OIL PUMP PRESSURE (PSIG) APPROXIMATE S SHUTTER BAND NOTE: 1. S.S. Wrapped shield air-tube assembly 1051A 160B. Air shutter blank part # 1007-1 Dual slotted air band 1008. 2. Standard air-tube part number 1051-5. WKD = Water knocked down. SKD = Steam knocked down * To see how adjustments are made on CARLIN & BECKETT burners, see illustrations only on pages 11 & 12 of publication LD-40, but use values in table 3, above. Wayne blue angel part # 100-393 flame lock Wayne blue angel part # 100-389 air cone with 6 holes. All pump pressures may be 100 PSI but will fire at a slightly lower rate except Riello. 4

Table 4: Field supplied burners for knocked down boilers with Slant/Fin supplied full combustion chambers. BOILER FIRING RATE SIZE NOZZLES ANGLE & TYPE LD-50 Beckett AFG F-22 2.10 2.00 80 H HAGO WKD & SKD 80 W DELAVAN 110 10* 2* N.A LD-50 Beckett AFG F-12 2.35 2.25 80 SS HAGO WKD 80 W DELAVAN 109 1* 3* N.A. LD-50 Carlin 102 CRD Standard 2.10 2.00 70 SS HAGO 110 WKD & SKD Note 1 70 W DELAVAN FULL 20%* 4* LD-50 Carlin 102 CRD Standard 2.35 2.25 70 SS HAGO WKD Note 1 70 W DELAVAN 109 FULL 50%* 5* LD-50 Beckett AFG F-164 2.10 2.00 80 SS HAGO WKD & SKD 80 W DELAVAN 110 10* 2* N.A. LD-50 Beckett AFG F-164 2.35 2.25 80 SS HAGO WKD 80 W DELAVAN 109 10* 3* N.A. LD-50 Blue Angel HS #10 2.10 2.00 80 H HAGO 1.5 5 WKD & SKD Note 2 Vane 80 W DELAVAN 110 6.5 damper LD-50 Blue Angel HS #10 2.35 2.25 80 H HAGO 109 7 1.5 7 WKD Note 2 Vane damper LD-50 Riello 40 F-10 2.10 1.75 60 W DELAVAN 150 3.5 N.A. 3 WKD & SKD Series 1.65 60 SS HAGO 162 4.5 N.A. 4 LD-50 Riello 40 F-10 2.35 1.75 60 W DELAVAN 170 4 N.A. 3 WKD Series 60 ES HAGO LD-50 ABC FC-234 2.10 2.00 60 P HAGO 110 NONE FULL & 1/2 WKD & SKD 60 W DELAVAN 1" LD-50 ABC FC-234 2.35 2.25 60 P HAGO 109. NONE FULL & 1/2 WKD 70 W DELAVAN 2 MFR. OIL PUMP PRESSURE (PSIG) APPROXIMATE S SHUTTER BAND NOTE: 1. Standard air-tube part number 1251B-5. 2. Wayne blue angel part number 100-393 flame lock. All pump pressures may be 100 PSI but will fire at a slightly lower rate except Riello. * To see how adjustments are made on CARLIN & BECKETT burners, see illustrations only on pages 11 & 12 of publication LD-40, but use values in table 4, above. WKD = Water knocked down SKD = Steam knocked down 5

Figure 1 Beckett AFG Note 1: Extended head for only (F4S, F-120, & F-164 heads). Note 2: 2-3/4 static plate. Note 3: Insertion depth 2-5/32 for F4S & F120, 1-23/32 for standard heads. (F-6, F-60, F-12 and F-22) Note 4: Insertion depth 2-21/32 for F-164 head. Note 5: Boiler model L-50 does not use static plate. Remove plate if so equipped. Figure 2A Carlin 99FRD Standard Figure 2B Carlin 99FRD Figure 3 Wayne Blue Angel Burner Gun Setting Gauge Instructions (for HS series burners only) 6

Figure 4 ABC FC134 and FC234 5. Set electrodes as shown (5/16 above nozzle centerline, 1/32 from cup and 1/8 gap). 6. Reinstall firing assembly by reversing the procedure in paragraph no. 1. 7. Adjust cup to end-cone, dimension B, to firing rate by turning the dial at rear (see below) clockwise. This will pull firing-assembly away from end-cone, while exposing a 4-division scale. The amount of scale exposed is the distance (dimension B the combustion head is back from the end cone. For optimum burner efficiency fine tune (forward/backward) the final firing assembly location. 8. Tighten all screws and copper tube fittings. END VIEW Nozzle specifications HAGO ES or F, MONARCH AR or EQUAL (solid spray. Spray angle as required by shape of combustion area. 9. Check for leaks and oil cut off before leaving premises. See approximate head settings in tables 2&3. DIMENSIONS A FC 134 = 2-5/8 FC 234 = 3 DIMENSIONS B See approximate head settings in tables 2 & 3 ABC Sun Ray FC Series Burner Specifications Motor Fuel Unit Burner Sundstrand & Webster Model HP RPM Standard Optional FC-134 1/7 3450 One stage Two stage FC-234 1/7 3450 One stage Two stage Note: Specifications subject to change without notice. Part No. H40071 Setting Gauge Available On Request 1. To install the nozzle, the firing assembly must be removed. Remove copper tubing from elbow connection. Remove lock screw on ignition transformer and open. Lift end of firing assembly slightly and carefully pull out. Note: Spring pressure will cause some resistance. DO NOT force or bend the pipe and/or cup. 2. Loosen clamp screw on cut bracket and remove from nozzle adaptor. Examine cup for distortion. A bent cup will alter the firing characteristics of the burner. 3. Inspect the nozzle adaptor seat for any defects. A loose or improperly seated nozzle will cause an oil leak and poor oil cut off. Use an ideal type nozzle wrench or two wrenches to remove or tighten the nozzle. VIEW A-A FLAME RETENTION DIAL & SCALE DETAIL (enlarged) Figure 5A Riello 40 Series Model F-5 ELECTRODE 4. Reinstall the cup on the nozzle adaptor, with the leg having the part number between the electrodes. Slide the cup back against the adaptor shoulder and tighten clamp screw. Check that the cup bracket does not touch the electrode insulator. 7

Figure 5B RIELLO 40 SERIES F-10 ELECTRODE Important: For proper insertion into chamber (see figure 8). THE ADJUSTMENT PLATE (See figure 7) 1. The hydraulic SHUTTER (A) is operated by the HYDRAULIC JACK (F), assuring complete opening of the combustion air intake. Regulation of the combustion air flow is made by adjustment of the manual ADJUSTMENT PLATE (D) after loosening the FIXING SCREWS (C &E). The initial setting of the air adjustment plate should be made according to pages 3, 4 and 5. 2. The proper number on the manual ADJUSTMENT PLATE (D) should line up with the INDICATOR (B) on the fan housing cover. Once set, the air adjustment plate should be secured in place by tightening SCREWS C and E. Manually open and release the hydraulic air shutter to ensure it has free movement. 3. The final position of the air adjustment plate will vary on each installation. Use instruments to establish the proper settings for maximum CO 2 and a smoke reading of zero. NOTE: Variations in flue gas, smoke, CO 2 and temperature readings may be experienced when the burner cover is put in place. Therefore, the burner cover must be in place when making the final combustion instrument readings, to ensure proper test results. Figure 7 NOTE: ELECTRODES ARE PRESET AT THE FACTORY. REGULATION OF THE TURBULATOR AND SHUTTER FOR FOR PROPER COMBUSTION Turbulator Setting 1. Loosen nut, 1, then turn the screw, 2, until the index marker, 3, is aligned with the correct index number. 2. Retighten the retaining nut, 1. TURBULATOR S - RIELLO 40 SERIES The numbers on the casting are there to denote the high and low end of the scale - in all cases the first mark if Zero. The air/oil ration depends on accurate setting of the turbulator disc. Be careful when making this adjustment as an incorrect setting will result in an unsatisfactory installation. See figures 6A, B. Figure 6A Figure 8 FOR PROPER INSERTION INTO COMBUSTION CHAMBER Figure 6B SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 Phone: (516) 484-2600 FAX: (516) 484-5921 Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario www.slantfin.com