TECHNICAL DATA SHEET 400 Series Pneumatic Actuators

Similar documents
Model 8329 Table of Contents

DP Series Diaphragm Valve Installation and Maintenance Instructions

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators

Ball Valves in investment cast stainless 2-way

Air Operated 3 Way Stainless Steel Ball Valve

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Model Table of Contents. SERVICE & OPERATING MANUAL Original Instructions. Instructions Sheet:

USER'S MANUAL and INSTALLATION GUIDE

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

S E LV Ball Valves VA

55-Gallon Powder Drum Truck

IOM Manual. IOM Manual. Series 76/77.

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

SECTION 4 - FUEL SYSTEMS AND CARBURETION

INSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR

Air Operated Stainless Steel V-Ball Control Ball Valve

INSTALLATION AND OPERATING MANUAL

Service and Parts Manual. Minimum Filtration Required:

Solenoid Valve Manifold for use with Digital Pressure Control Coupler

PN K K050012: Rebuild Kit for Delco Non-Delay Height Control Valve

DO NOT INSTALL, OPERATE, OR MAINTAIN AN ATI PRODUCT UNLESS TRAINED AND QUALIFIED IN PRODUCT AND ACCESSORY INSTALLATION, OPERATION AND MAINTENANCE.

G Type Range of Actuators

Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT

M673LD3 / M673L3. Soundshield Assembly Instructions. East Coast Branch th Avenue. 15 Aegean Dr. Northwest. Suite 4 Seattle, WA 98107

I & M MK96 & MK96C. Ideal Installation. Start-Up. Maintenance PROTECT VALVES WITH LINE STRAINERS

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

Economy Air Operated Brass Ball Valve

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

INSTALLATION & MAINTENANCE MANUAL

Thank you for purchasing a Nelson RainTrain2.

Nikki Carburetor Vertical Models , ,

33 CENTERVILLE ROAD LANCASTER, PA

INSTALLATION INSTRUCTIONS

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules.

INSTALLATION AND OPERATING MANUAL

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01

P99 Pressure Reducing Regulator

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

505F Multi-Port Ball Valve

Transfer Valve Actuator Overhaul Instructions

Chapter 11: Valves and Actuators with the NAMUR-interface

Control Valves & Valve Accessories

Air Operated 3 Way Brass Ball Valve

PMV P36C AND P41C POSITIONERS ACTUATORS

26 Series Stainless Steel 2-way Ball Valves

EVP SERIES PROPORTIONAL CONTROL VALVES

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

AS-Interface Installation Manual. ASAHI / AMERICA, Inc. Thermoplastic Valves and Piping Systems

36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance

OPERATION AND MAINTENANCE INSTRUCTIONS


CR4 Discrete Valve and Manifold Valve Repair or Replacement Procedure

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

Pilot-Operated Regulators

Installation Operation Maintenance

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2)

Railroad Ball Valves Series 5REB3

Pneumatic Actuator Durastroke Series 2000 Installation & Maintenance Instructions

Multiple Nozzle Body Assemblies for Dry Booms

Air Operated Stainless Steel 6000psi Ball Valve

New$Ways$of$Gas$Bearing$Sealing$In$Bulk$Powder$Handling$ By#Drew#Devitt# Founder,#CTO# New#Way#Air#Bearings# # #

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

IOM FOR DYNATORQUE D-LOCK LOCKING DEVICE (DL TYPE)

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

1/2" AIR DRIVEN DIAPHRAGM PUMP

82 SERIES PTO PARTS LIST AND SERVICE MANUAL

INSTALLATION INSTRUCTIONS

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.

Pneumatic Actuators. 1. DIE CAST ALUMINUM END CAPS: standard polyester powder coated

specification DAtA V R0 pilot operated tank blanket VAlVe, pressure regulating VAlVe SERIES V500

Operation and Maintenance Manual

A Type Double Acting Actuator Type: PA2911

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT

Product Maintenance Information

AV-430. Application. Features. Applicable Literature. Valve Linkage for Pneumatic Actuators General Instructions

505F. Multi-Port Ball Valve. Full Port ISO 5211 Mounting Pad. For Automated & Manual Service. General Chemical. Industrial

TECHNICAL INSTRUCTIONS

Winslow Liquid Fuel Filters Standard Design Type 2 Service Instructions

INSTALLATION, OPERATION & MAINTENANCE MANUAL Description Handling Installation Actuators...

HD Series. Pilot-Operated Regulating Valves. HD Series features & benefits

VG7000 Valve Linkage for M100 Series Motor Actuators

Installation Instructions

ILD LOCK CYLINDER CHANGE-OUT INSTRUCTIONS REVISION 2_012505

McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC

PNEUMATICALLY ACTUATED 2-WAY

INSTALLATION INSTRUCTIONS

VAL-138. Valves. Electrical Details for Solenoid Pilot. Operating Pressure

INSTALLATION AND OPERATING

Installation Guide. 3-Way/2-Way Transfer Valve E

TCI E4OD/4R100 Valve Body Performance Improver Kit

Air Actuated 3-Way Ball Valves T-Port, Lead Free Brass, Full Port 1/4 to 2 NPT

Flowserve Spring Diaphragm Rotary Actuators

TERMITICIDE APPLICATION TOOLS

INSTALLATION MANUAL. MB-180, MB-210 and MB-210L Motor Brake INSTALLATION. Force Control Industries, Inc. DESCRIPTION OPERATION

Fisher 3024C Diaphragm Actuator

Transcription:

TECHNICAL DATA SHEET 400 Series Pneumatic Actuators 2 Otter Court, Raymond, New Hampshire 03077 Tel. (603) 895-4761 FAX (603) 895-6785 www.geminivalve.com DESCRIPTION The 400 Series actuators are Gemini s legacy line of compact pneumatic automation. The 400 Series may be fitted to all Gemini 76, 86, 96, & 89 Series Valves by means of a rigid, precise mounting system. MATERIALS OF CONSTRUCTION BODY, END CAPS: : Aluminium with Teflon Imprenated Hard Anodized (PolyLube ) Sufaces SPRING MODULES: Aluminium with Teflon Imprenated Hard Anodized (PolyLube ) Sufaces SHAFT / DRIVER & EXTERNAL TRIM: 300 Series Stainless Steel RATINGS / SPECIFICATIONS TEMPERATURE: -20 F to 350 F POWER: Models B412D, A422D; 50-125 psi air, models B411D, A421D, B412SR, A422SR 75-125 psi air. Sufficient air delivery must be available at the actuator to ensure dependable operation. The following precautions should be observed: Air supply should be clean and free of moisture. When dirty or wet air is a problem; a filter / separator should be specified; these units are most effective when installed as closely as possible to the actuator. A filter, when used, should permit a minimum flow of 4 scfm at an upstream pressure of 60 psi. Eliminate severe restrictions to air flow (certain solenoid valves & fittings). The most restricted passage must have an area no smaller than.012 inches square, the area of 1/8 diameter orifice. If more than a single actuator is to be supplied by an individual pilot, the minimum passage requirement applies per actuator. TUBING: For short runs up to 5 feet 5/32 I.D. is suitable, 1/4 I.D. will serve up to 30 feet. For longer runs, use 3/8 I.D. or larger. TDS0010-0408

RATINGS / SPECIFICATIONS (continued) DUTY CYCLE: 100% CYCLE TIME: (To Open or Close) Approximately 1/2 to 1 second* * - Dependent upon actuator model, air pressure and delivery MAINTENANCE Gemini 400 Series Pneumatic Actuators are designed to be maintenance free and normally are replaced vs. repaired. Double-Acting Models: For double-acting models, rebuilding of the actuator by our Factory Authorized Service Center may enable the actuator to be returned to service depending on the duty cycle the actuator has seen. The cost to rebuild the actuator is generally 50% of the cost of a new actuator. For details on this service please contact us. Additionally, for those customer desiring to replace 0-rings, gasket(s) and lubricant, we offer o-ring kits which contain these genuine factory components. Spring-Return Models: The 400 Series are not recommended to be rebuilt and should be replaced when they have seen their useful life.

ACTUATOR TO VALVE MOUNTING INSTRUCTIONS 76, 86 & 96 SERIES VALVES These instructions detail the procedure for installing a Gemini 400 Series pneumatic actuator on a drive-key equipped Gemini 76, 86 or 96 Series ball valve. Valves may be purchased with the drive-key assembled or may be retrofitted with a drive-key conversion kit. Assemble Bracket to Actuator 1. Position the bracket gasket on the actuator mounting surface so that the alignment pins engage the slots (B410 Series) or holes (A420 Series) in the gasket. 2. Place the bracket, from the mounting kit, on the mounting surface over the gasket so that the alignment pins engage the bracket. In the interest of uniformity, mount the bracket so that the valve locator is on the same side as the actuator inlet ports (or spring module if you are mounting a spring return) as shown in Figure 1. Assemble Valve to Actuator 1. Double Acting Actuators: Check the valve to be sure that it is either completely open or completely shut. Observe the OPEN / SHUT indicator mounted on the actuator shaft; turn the shaft if necessary so that the indicator corresponds to the position of the valve. Spring Return Actuators: Turn the valve stem to orient the ball in the desired for spring action, i.e. spring to open or spring to close. Observe the OPEN / SHUT indicator mounted on the actuator shaft to assure that it reads correctly. If it does not, remove the two screws which hold the indicator cover and rotate the cover 180 degrees, reinstall the screws. 2. Place the actuator, with the bracket attached, atop the valve so that the 12 point socket engages the stem nut, the shaft notch engages the drivekey and locator engages the valve body hex. If your valve is a Series 86 or 96, the locator must contact the valve body on the side opposite the end plug as shown in Figure 2. If the valve stem nut will not engage the socket in the coupling, reposition the nut slightly (this should require less than 1/12 turn). The valve locator has been preassembled to the bracket to fit your valve; if the valve locator does not engage the hex, or if it prevents the bracket from contacting the upper surface of the valve body, it must be repositioned. 3. Position the retainer on the underside of the valve and fasten to the actuator bracket with the two hex-head capscrews. Tighten the screws alternately to assure balanced pulldown and to avoid skewing of the actuator bracket on the valve body. Continue tightening only until the actuator is securely anchored. A gap should remain between the lower surface of the bracket and the retainer ears when the assembly is complete.

ACTUATOR TO VALVE MOUNTING INSTRUCTIONS 89 SERIES VALVES These instructions detail the procedure for installing a Gemini 400 Series pneumatic actuator on a drive-key equipped Gemini 89 Series ball valve. Valves may be purchased with the drive-key assembled or may be retrofitted with a drive-key conversion kit. Assemble Bracket to Actuator 1. Position the bracket gasket on the actuator mounting surface so that the alignment pins engage the slots (B410 Series) or holes (A420 Series) in the gasket. See Figure 1; the mounting surface is crosshatched. 2. Place the bracket, from the mounting kit, on the mounting surface over the gasket so that the alignment pins engage the blind holes in the bracket. 3. Assemble the bracket to the actuator with two finethread socket head screws. (The B410 Series uses button-head socket screws; the A420 Series, standard socket head screws.) Tighten securely. Assemble Valve to Actuator 1. Double Acting Actuators: Check the valve to be sure that it is either completely open or completely shut. Observe the OPEN / SHUT indicator mounted on the actuator shaft; turn the shaft if necessary so that the indicator corresponds to the position of the valve. Spring Return Actuators: Turn the valve stem to orient the ball in the desired for spring action, i.e. spring to open or spring to close. Observe the OPEN / SHUT indicator mounted on the actuator shaft to assure that it reads correctly. If it does not, remove the two screws which hold the indicator cover and rotate the cover 180 degrees, reinstall the screws. 2. Place the actuator, with the bracket attached, atop the valve so that the 12 point socket engages the stem nut, the shaft notch engages the drive-key. If the valve stem nut will not engage the socket in the coupling, reposition the nut slightly (this should require less than 1/12 turn). Force the actuator and valve together until the actuator bracket bottoms in the valve bracket. 3. Fasten the actuator to the valve with two sockethead mounting screws. Your Gemini Actuated Valve is now ready for service.

ACTUATOR TO VALVE SELECTION DATA Actuator Models Suitable for Valve Series & Size 76 86 96 89 (Port) 309 B411D B412D B412SR A421D A422D A422SR 1/2 1/4& 3/8-0.5 1/2 3/4 1/2-0.6 3/4 1 3/4 1/2 - - 1-1/4 1 3/4 0.8-1-1/2 1-1/4 1 1.0-2 1-1/2 1-1/4 1.2 - - 2 1-1/2 1.5 -

DIMENSIONS 76, 86 & 96 SERIES VALVES 89 SERIES VALVES