Pow-R-Flex low ampere busway

Similar documents
Pow-R-Way III low voltage busway. Meeting the needs of a global marketplace

Pow-R-Way III Low Voltage Busway. Product Focus. Pow-R-Way III Offers a Full Line of Low Voltage Busway to Meet the Needs of a Global Marketplace

BUSWAY Low Voltage (Pow-R-Flex)

Low voltage busway Pow-R-Flex low ampere busway

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Low voltage busway Pow-R-Flex low ampere busway

Busway Construction. Bus Bars

Pow-R-Way III Busway Service and Solutions

Engine Generator Circuit Breakers

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Mining service breakers with true rms sensing designed specifically for trailing cable applications

Medium Voltage Metal-Enclosed Switches

PowerWave Bus System. For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Metal-enclosed medium-voltage power factor correction system

Metal-enclosed medium voltage power factor correction system

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Medium Voltage Metal-Enclosed Switches

COMPACT BUSWAY 40 & 60 AMP HOUSING

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Ampgard The name motor applications rely on

PDI PowerWave 2 Bus System

Dry-Type Transformers Mini-Power Centers

INTEGRID TRACK (120V) SPECIFICATIONS

Specification made simple for selective coordination in a compact size

Design Standard. Purpose: Design Standard:

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

POWERBUS 225 Busway and Plug-In Units

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K

Quick selector reference guide. Pow-R-Stock panelboards, safety switches, and transformers

WavePro LT Busway Cost effective solution for electrical distribution

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Generator Fire Safety: Generator assemblies should be located outside the building.

Product Selection Guide: T5 Series- 250, 400 & 800 Amps

MOUNTING SYSTEMS SPECIFICATIONS

A. Submit manufacturer's literature and technical data before starting work.

SURFACE TRACK (120/250V) SPECIFICATIONS

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

Product Selection Guide

HIGH POWERBAR COPPER UL857

University of Houston Master Construction Specifications Insert Project Name

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Professional Engineering Services. Service Focus. PowerChain Management Audit

Busway Products Medium Voltage Busway Nonsegregated Phase Bus

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

ASCO SERIES 185 Power Transfer Switches

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

LSI 20 Series 30A, 120V Surface Busway Components 1

Low Voltage Busway. 6.2 Pow-R-Flex A Busway

Put the Power in Your Hands

SECTION PANELBOARDS

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Critical Power Switchboards. Selection and Application Guide

Product Guide. enclosed NEMA STARTERS

PowerWave 2 TM Bus System

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Introduction. Upon completion of Busway you should be able to:

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

POWERPLEX PANELBOARD 1

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

Service Entrance Methods

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

Bolted contact switches. Pringle switches

Flexible, Customizable Power Solutions for Mission Critical Success

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

RECESSED TRACK (120V) SPECIFICATIONS

This small footprint makes a BIG impact

SD Series. Cord and Light Reels. Engineered Solutions to Help you Work Smarter and Faster. Quality Cord and Light Reels

Single-Phase Step Voltage Regulators

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

2016 Photovoltaic Solar System Plan Review List

Multi-Pak Group Control

W-VACi MV circuit breakers

Product guide. Enclosed NEMA starters. Answers for industry.

Single-phase step voltage regulators

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Power System Solutions (PSS)

Power Break II Switchboard

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

University of Houston Master Construction Specifications Insert Project Name

INTELLIGENT MEDIUM POWERBAR

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

New Products for Integrated Electrical Systems/Questions and Answers/Resources. necdigest. Bringing a new level of electrical protection into the home

RV Park Equipment Product Focus. Power Pedestals Distribution Equipment

Transcription:

Pow-R-Flex low ampere busway Commercial Industrial Telecommunications Data centers Research Light manufacturing Pow-R-Flex low ampere busway

Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway provides flexible power distribution solutions for a variety of applications where change and adaptation are important. Product offering Plug-in busway Feeder busway Busway fittings Plug-in units 225 to 600 amperes copper 150 to 400 amperes aluminum Straight sections of plug-in busway are available in 24-inch (609.6 mm) incremental lengths from 2 feet (0.6m) to 10 feet (3.0m) maximum Plug-in outlets are on one side, spaced every 12 inches (304.8 mm) for a standard nine plug-in outlets per 10-foot (3.0m) section Each joint location is adjustable +/ 0.50-inch (12.7 mm) in length 225 to 600 amperes copper 150 to 400 amperes aluminum Straight sections of indoor busway are available in 1-inch (25.4 mm) increments from 2 feet (0.6m) to 10 feet (3.0m) Each joint location is adjustable +/ 0.50-inch (12.7 mm) in length Standard 90-degree elbow bends upward, downward, forward and rearward directions Standard tee fittings forward and rearward directions Offset fittings upward/downward, forward/rearward directions Cable tap boxes end and center positions Gear flanges Phase transpositions Expansion joints Molded case circuit breaker overcurrent protection from 15 to 250 amperes Fusible overcurrent protection from 30 to 200 amperes Surge protective devices (SPDs) 240V receptacle units with circuit breaker overcurrent protection from 15 to 60 amperes 480V receptacle units with circuit breaker overcurrent protection from 15 to 60 amperes Eaton s Pow-R-Flex low ampere busway is the latest design in a family of innovative busway products and is the newest in the industry. Pow-R-Flex offers a heavy-duty design and does not sacrifice on aesthetics. Standard features include an extruded aluminum housing, two standard color options, shutter mechanism safe plug-in outlets, integral ground path, high short-circuit withstand ratings and a variety of plug-in units. Through barrier penetration fire barriers End closures www.eaton.com/busway 3

Pow-R-Flex capabilities Innovative housing design Pow-R-Flex is constructed with lightweight and rugged U-shaped extruded housing. The U-shaped housing is the base channel that holds the conductor support blocks. Front covers are then used and are also made from lightweight, extruded aluminum. The U-shaped base housing and front cover are joined together through a unique hinge design that locks in one side of the cover, reducing fasteners and offering clean lines. This adds to the aesthetic look and feel of the product. This innovative housing design puts safety first and totally encloses the conductors, preventing any incidental contact with live conductors. The non-magnetic, all-aluminum housing provides for excellent heat dissipation and a significant reduction in reactance and magnetic flux leakage as compared to a steel or steel and aluminum combination housing. The integrity and strength of the housing ensures specifiers and users of a safe and durable installation over a broad spectrum of applications. Product features and benefits This world-class product design meets the requirements of NEMAT, UL,T CSAT and ISOT The aluminum housing provides lightweight durability and product integrity The Pow-R-Bridge joint assembly and torqueindicating bolt provides a durable, flexible, secure and easy-to-install connection Unique housing design allows for simple flush mount or back-to-back installations Silver-plated contact surfaces provide highquality connections Extruded housing channels provide simple and secure support and accessory connections Flexible neutral and ground options provide solutions for any application problem Multiple short-circuit withstand ratings coordinate with any electrical system A full family of plug-in units is available for every power need Product support Busway product and application support is available from a professional team of Eaton employees that includes field sales engineers, application engineers, Eaton Engineering Services & Systems, and the Greenwood plant busway sales and product engineers. Pow-R-Flex capabilities Plug-in units are available in stock for immediate shipment in select ampere ratings and system configurations The busway manufacturing facility is located in Greenwood, SC, and is able to meet your emergency or quick ship lead-times from one day to three weeks Customer approval drawings are available in three weeks or less to meet your project requirements The Eaton Final Field Fit program ensures accurate layout and allows for minor last-minute layout modifications during installation The Eaton Field Measurement Service takes the time and worry out of getting accurate layout measurements and guarantees an accurate installation Additional information Technical Data TD01701003E Installation and Maintenance Instructions IB01701002E Distribution Equipment Catalog CA08101001E Busway Service and Solutions Brochure BR01701002E Pow-R-Bridge joint Pow-R-Flex joint connections are made with the heavy-duty Pow-R-Bridge joint package. One Pow-R-Bridge is installed on each section of Pow-R-Flex busway prior to shipment. The bridge joint assembly uses a double-headed, torque-indicating bolt to ensure that the proper installation torque is achieved. No special tools or equipment are required to torque down the joint bolt. Torque is applied only to the outer bolt head. When the proper torque value is achieved, this outer bolt head will shear off, allowing fall-away instruction tags to fall to the floor. The fall-away instruction tags allow for visual torque indication from a distance. Any joint that is improperly torqued will retain the highly visible (caution yellow) tag at the bolt head. The inner bolt head remains intact for future work and a label with the proper torque information is provided on the Pow-R-Bridge. Due to the single bolt non-rotating design, the Pow-R-Bridge maintains its configuration integrity when it is removed from a section of busway. The conductor plates and insulators do not displace or swivel, making re-installation quick and easy. The insulators are made of a high-strength, molded glass polyester and are rated as Class B, 130ºC, insulating material. www.eaton.com/busway 5

A safety-first plug-in busway design All Pow-R-Flex plug-in busway and plug-in devices are designed with the safety of the installer and user as key criteria. Plug-in outlets protect against accidental contact with live conductors by an operator/installer. Each outlet has a mechanical spring shutter that automatically pushes closed when a plug-in unit is removed and the outlet is no longer in use. Each outlet is shipped with the shutter held closed with a screw. The screw must first be removed before the outlet can be used. Once the screw is removed, the shutter is mechanically operated by the plug-in unit when the plug-in unit is being inserted into the outlet on the busway. One plug-in outlet or provision is provided every 12 inches (304.8 mm) along the busway. Each plug-in unit ground stab makes positive contact connection with the integral busway housing ground and/or internal ground bar before the phase and neutral stabs make contact with the phase conductors. Pow-R-Flex offers grounding and neutral options to meet every customer preference and need 50% 50% 50% integral ground The extruded aluminum housing is UL listed as a 50% integral ground path (integral earth) and is fully fault rated. The system ground continuity is maintained through each joint by ground path contact surfaces in the joint covers. When the covers are installed, the contact surfaces are bolted directly to the extruded aluminum housing. 50% internal ground bus If a traditional 50% internal ground bar conductor is preferred, Pow-R-Flex can be fitted with a ground bus that runs internal to the housing similar to the phase conductors. The internal ground bus is raised within the housing to ensure that plug-in unit ground stabs make positive ground contact before making contact with the phase conductors. 100% 100% ground option In certain industrial applications, a ground path greater than 50% may be required. Pow-R-Flex makes this possible without the need to overrate the busway. By combining the 50% integral ground with the 50% internal ground bus, a fully rated 100% ground path is achieved. Oversized neutral option Power system harmonics are generated by various types of nonlinear loads. Examples of nonlinear loads are personal computers, UPS systems, variable frequency motor controllers, electronic lighting ballasts, medical test equipment, and many other microprocessor-based loads. On 208 volt wye systems, certain nonlinear loads cause odd triple harmonics that are additive and will not cancel each other in the neutral. The neutral current can be as high as 1.73 times the phase current. This can lead to a deterioration of equipment performance and shortened life cycle. Pow-R-Flex offers oversized neutral ratings on its low to mid current ratings. The additional neutral capacity prevents the overheating caused by high harmonic neutral currents. 6

A complete line of fi ttings to meet any application Pow-R-Flex offers an extensive range of Accessory fittings make installation easy Pow-R-Flex offers a complete complement of accessory fittings to finish off every installation. Wall flanges are available to help close off the cutout opening around the busway as it passes through the wall. Several types of hangers are available to help suspend, support and stabilize the busway system. Hardware is included with each accessory fitting. Innovative plug-in unit designs A variety of plug-in units have been designed for the Pow-R-Flex low ampere busway to meet multiple applications and a variety of installation conditions. Plug-in unit devices provide easy and flexible access to a building s electrical power system, while providing safe and overcurrent protection to equipment and wiring. All Pow-R-Flex plug-in units are designed with the safety of the installer and user in mind. The following safety features are standard for all fusible and molded case circuit breaker plug-in units: Positive Ground Contact Each plug-in unit ground stab makes positive contact with the busway ground (integral or internal) before the phase or neutral stabs make contact with the conductors. Guide Tabs Plug-in unit molded guide tabs are provided in the stab support base. These ensure proper phase alignment and open the busway outlet shutter mechanism. Interface Bracket Each plug-in unit has an interface bracket, which prevents the unit from being installed onto or removed from the busway while the device is in the ON or CLOSED position. Door Interlock Each plug-in unit has a door interlock, preventing the front cover from being opened while the device is in the ON or CLOSED position and preventing accidental closing of the device while the front cover is open. Line-Side Barriers Line-side barriers are provided over the line-side terminals to help prevent accidental contact with line-side connections. Outlet Seating Ridge When the plug-in unit is installed, the stab base assembly on the plug-in unit is recessed into the busway outlet cover to help seal against moisture and dust. Mounting Flanges Each plug-in unit has mounting flanges that bolt the unit to the housing and help protect the stab base assembly. Mounting hardware is included. fi ttings to meet every application need. Flanges, elbows, end cable tap boxes and end closures are some of the basic fi ttings that are included in the Pow-R-Flex design. For more complex layouts, combination elbows and offsets can be used along with expansion joints, tees, phase transpositions and vapor fi re barriers. With Eaton s experienced engineering staff, customized fi ttings and connections are available to meet unique applications. 8 www.eaton.com/busway 9

Plug-in units 240V plug-in unit devices Receptacle plug-in units Eaton s unique receptacle plug-in unit design makes them the most flexible receptacle units in the industry. They are well adapted for use in data centers, laboratories, machining shops, industrial manufacturing or anywhere small blocks of power are required. Pow-R-Flex receptacle plug-in units come fully assembled and wired, reducing installation time. Each unit is built to order based upon the receptacle type and rating combinations. Additionally, Eaton optimally phase balances each unit for the entire run. This eliminates the need to manually phase balance during installation. Each unit is UL and CSA listed and comes in seven different styles and two different breaker options using standard NEMA receptacle configurations. Single Receptacle Single receptacle units come with one receptacle and may be fitted with a single- or three-phase receptacle up to 60 amperes and 480 volts. Double Receptacle Double receptacle units come with two receptacles and may be fitted with any combination of single- and three-phase receptacles up to 60 amperes and 480 volts. Quad Receptacle Quad receptacle units come with up to four receptacles and may be fitted with any combination of single- and three-phase receptacles up to 60 amperes and 480 volts. Receptacles may be fixed-mounted to the front of the enclosure or cord-mounted to S/O cable dropping out the bottom of the unit. 400/480V plug-in unit devices SPD plug-in units Surge protective device (SPD) plug-in units are available in Pow-R-Flex plug-in units. The Eaton SPD Series products not only protect against externally created high-energy surges, such as lightning, but also provide needed protection against internally generated surges. Such surges may come from arc welders, adjustable frequency controllers and the switching on and off of electrical distribution equipment. The Eaton SPD combines metal oxide varistors (MOVs) for suppression and filtering capacitors to eliminate electrical line noise and ringing transients. IQ Energy Sentinel The Pow-R-Flex molded case circuit breaker plug-in units optionally include the IQ Energy Sentinel, a UL listed microprocessor-based submetering device capable of communication energy usage, demand usage. This innovative device offers internal CTs and is powered off the load-side cable terminations. Communications are done via customer-installed twisted-pair communications cable. Communication protocols include RS-232, Modbus,T Ethernet and Eaton INCOM. 10 www.eaton.com/busway 11

Eaton s Electrical Sector is a global leader in power distribution, power quality, control & automation and monitoring products. When combined with Eaton s full-scale engineering services, these products provide customer-driven PowerChain ManagementT solutions to serve the power system needs of the data center, industrial, institutional, public sector, utility, commercial, residential, IT, mission critical, alternative energy and OEM markets worldwide. PowerChain Management solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eaton.com/electrical. Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com 2009 Eaton Corporation All Rights Reserved Printed in USA Publication No. BR01701003E / Z9017 October 2009 PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.