Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

Similar documents
Cutler-Hammer. January 2001

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Cutler-Hammer. January 2001

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Switchboards Instant Service

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

Product Line Overview. The Most Logically Designed Contact Assembly

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Molded Case. Circuit Breakers. Molded Case Circuit Breakers Contents

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

2.3. Molded Case Circuit Breakers. Contents

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Products :: Circuit Protection :: Thermal Circuit Breakers

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

Engine Generator Circuit Breakers

Product Selection 3-Pole Contactors

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

30 ma Ground Fault (Earth Leakage) Modules. Product Description

A302DN.40/.63A Thermal Current Motor Starter

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

XT IEC Power Control Manual Motor Protectors

SECTION PANELBOARDS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Application guide. Tmax Link OEM UL 891 Switchboard Program

Lighting and Power Distribution Panelboards

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

3. Coils shall be of molded construction

F-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at:

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

CENTERLINE 2100 Motor Control Centers

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

Industrial Control Transformers

SECTION MOTOR REQUIREMENTS for HVAC

Enclosures. See Section Typical Description

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

' '!' D Model, 70 to 250 Amperes. W Model, 63 to 250 Amperes. www. ElectricalPartManuals. com

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

MOLDED CASE CIRCUIT BREAKERS

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Description Series 70/71 Solid State Reduced Voltage Starters

Overload Relay Heater Tables

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Design Standards NEMA

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

Selection Guide Motor Control Device Solutions

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

Bulletin 190-M Compact Starters. Selection Guide

SECTION MOTOR CONTROLLERS

Air Conditioning Disconnects Molded Case Switch

Big performance in a small package

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

File E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Technical Information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Application Description


Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

Circuit Breakers Naval Shipboard Use

Design Standard. Purpose: Design Standard:

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

SECTION MOTOR CONTROL

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Self-protected Combination Starters System PKZ 2-SP

Transcription:

Vol. 1, Ref. No. 10499) Product Selection Table 12-56. Types 12-33

12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems. They are described by NEMA as,... a device for closing and interrupting a circuit between separable contacts under both normal and abnormal conditions, and furthermore as,... a breaker assembled as an integral unit in a supporting and enclosing housing of insulating material. The NEC describes them as, A device designed to open and close a circuit by non-automatic means, and to open the circuit automatically on a predetermined overload of current, without injury to itself when properly applied within its rating. So designed, Cutler-Hammer circuit breakers protect conductors against overloads and conductors and connected apparatus, such as motors and motor starters, against short circuits. In low voltage distribution systems, there are many varied applications of molded case circuit breakers. Cutler-Hammer offers the most comprehensive family of molded case circuit breakers in the industry. This family of circuit breakers includes: Thermal Magnetic Trip Breakers Electronic rms Trip Breakers Molded Case Switches Motor Circuit Protectors Current Limiting Breakers Special Application Breakers World Breakers Special Calibration Special non-ul-listed calibrations are available for certain ambient temperatures other than 40 C and for frequencies other than 50/60 Hz or DC. Reduced interrupting ratings will apply for 400 Hz applications. Maximum thermal calibration is limited to 135A at 400 Hz. Suffix H01 400 Hz 20% Adder Moisture-Fungus Treatment All circuit breaker cases are molded from glass-polyester which does not support the growth of fungus. Any parts which are susceptible to the growth of fungus will require special treatment. Suffix J01 Fungus Treated Freeze-Tested Circuit Breakers The circuit breakers may be ordered with freeze testing. This option uses special lubrication and mechanical operation is verified at -40 C. Suffix F01 Freeze Tested Marine Applications F-Frame circuit breakers can be supplied to meet the following marine specifications: U.S. Coast Guard CFR 46 ABS American Bureau of Shipping IEEE 45 These specifications generally require molded case circuit breakers to be supplied with 50 C ambient calibration, special nameplating, and plug-in adapter kits. When plug-in adapter kits are used, no terminals need be supplied. Circuit breakers can also be supplied to meet UL489 Supplement SA (Marine Use) and UL489 Supplement SB (Naval Use). UL489 Supplement SA applies to vessels over 65 feet in length. Requirements include 40 C ambient calibration, special labeling, and no use of aluminum conductors or terminals. Suffix H08 Marine UL 489 Supplement SB requires 50 C ambient calibration, vibration testings, special nameplating and no use of aluminum conductors or terminals. Suffix H09 Naval $325. + 20% Adder 20% Adder 10% Adder 10% Adder Standards and Certifications Molded case circuit breakers are designed to conform with the following standards: Underwriters Laboratories, Inc., Standard UL489, Molded Case Circuit Breakers and Circuit Breaker Enclosures National Electrical Manufacturers Association Standards Publication No. AB1-1993, Molded Case Circuit Breakers Australian Standard AS 2184, British Standards Institution Standard BS 4752: Part 1, Switchgear and Control Gear Part 1: Circuit Breakers Canadian Standards Association Standard C22.2 No. 5, Service Entrance and Branch Circuit Breakers International Electrotechnical Commission Recommendations IEC 157-1, Circuit Breakers Japanese T-Mark Standard Molded Case Circuit Breakers South African Bureau of Standards, Standard SABS 156, Standard Specification for Molded Case Circuit Breakers Swiss Electro-Technical Association Standard SEV 157-1, Safety Regulations for Circuit Breakers Union Technique de l Electricite Standard NF C 63-120, Low Voltage Switchgear and Control Gear Circuit Breaker Requirements Verband Deutscher Elektrotechniker (Association of German Electrical Engineers) Standard VDE 0660, Low Voltage Switchgear and Control Gear, Circuit Breakers Conformance with these standards satisfies most local and international codes, assuming user acceptability and simplified application. Molded case circuit breakers equal or exceed Federal Specification Classification W-C-375b requirements for the particular class associated with the circuit breaker frame being considered. 50 C Calibration Add suffix V to Catalog Number for complete breaker, listed above, when ordering listed ampere ratings for breakers to be used in 50 C ambients. Note: For further information, see Circuit Breaker, CD-ROM SA.74A.01.T.E. For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

Vol.

12-32 Cutler-Hammer Vol.

Vol. I.Ref. No. [0501] Line and Load Terminals Line and Load Terminals provide wire connecting capabilities