DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-13344 This is to certify that the Terminal Block with type designation(s) MBKKB, MT, MTTB, UK, UKKB, ZFK;MBK, UHSK, UKH, UK, PIK, UKKB, UKK, MTK, UDK, URTK; URELG, UVKB.;USLKG Issued to Phoenix Contact GmbH & Co. KG Blomberg, Germany is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards Application Modular through terminal blocks. Protective ground terminal blocks. For use in Marine and Offshore Applications This Certificate is valid until 2016-12-31. Issued at Høvik on 2014-05-07 DNV local station: Essen CMC Western Germany for Det Norske Veritas AS Approval Engineer: Nicolay Horn Marit Laumann Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas. Form No.: TA 1411a Issue: 2013-10 Page 1 of 5
Name & Place of Manufacturer Phoenix Contact GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany Phoenix Feinbau GmbH & Co. KG Gustavstr. 3 58511 Lüdenscheid Germany Phoenix Contact India Pvt. Ltd Dhatir Road, Village-Dhudhola Prithla, Palwal, Faridabad 121102 Haryana India Phoenix Contact Wielkopolska Spolka z.o.o. Ul. Celna 5 64-300 Nowy Tomysl Poland Eviop Tempo S.A. Leoforos Kymis 212 340 02 Vasilikon Greece Phoenix Contact Asia-Pacific (Nanjing) Co. Ltd. 36 Phoenix Road Jiangning Nanjing 211100 Nanjing Peoples Republic of China Product description Modular straight through terminal blocks with srew connection according to the following type designations: Type designation Cross-section Rated Current Rated Insulation Voltage Cat. No. [mm 2 ] [A] [V] MBKKB 2,5 2,5/4 24 500 1414064 MT 1,5 1,5 17,5 400 3100305 MT 1,5-PE 1,5-3100318 MT 1,5-TWIN 1,5 17,5 400 3001682 MT 1,5-TWIN-PE 1,5-3001705 MT 1,5-QUATTRO 1,5 16 400 3001679 MT 1,5-QUATTRO-PE 1,5-3001695 MTTB 1,5 1,5 17,5 400 1414129 UK 1,5 N 1,5 17,5 500 3005837 UK 2,5 N 2,5 24 800 3003347 UK 3 N 2,5/4 24/32 800 3001501 UK 5 N 4/6 32/41 800 3004362 UK 6 N 6/10 41/57 800 3004524 UK 10 N 10/16 57/76 800 3005073 UK 16 N 16 76 800 3006043 UK 5 RETURN 4/6 32/41 500 3002597 UK 5 RETURN-PE 4/6-3002584 UK 5 RETURN-PE-1 4/6-3002636 UKKB 5 4/4 32 500 2771146 UKKB 5-PE 4/4-3007123 Form No.: TA 1411a Issue: 2013-10 Page 2 of 5
Polyamide terminal blocks Type designation Cross-section Rated Rated Insulation Ins. Material Cat.No [mm 2 ] Current [A] Voltage [V] MBK 1,5 18 500 PA 1401019 MBK 5/E 4 34 500 PA 1415076 UK 3 2,5 26 750 PA 3002018 UKKB 3 2,5 26 500 PA 2771010 UK 4 2,5 26 750 PA 3003017 UDK 4 2,5 26 750 PA 2775016 UDK 4-MTK 2,5 15 750 PA 2775265 UVKB 4-FS 2,5(4) 40 500(2) PA 1954016 UVKB 4-FS/FS 2,5(4) 40 500(2) PA 1953017 PIK 4-PE/L/L 4 26 380 PA 2714022 PIK 4-L/L 4 26 380 PA 2714035 PIK 4-L 4 26 380 PA 2714048 UK 5 4 34 750 PA 3004016 UK 5-MTK 4 15 750 PA 3004032 UKK 5 4 34 500 PA 2774017 UKK 5-DIO 4 34/1(3) 500 PA 2791016 UK 10 6 44 750 PA 3005015 URTK/S 10 61 380 PA 0311087 URTK/S-BEN 10 61 500 PA 0309086 UK 16 10 61 750 PA 3006014 UHSK/S 2000 10 61 2000 PA 0704076 UKH 25 25 108 1000 PA 3009011 UKH 50 50 168 1000 PA 3009118 UKH70 70 192 1000 PA 3213140 UKH70-PE/S 70 - - PA 3213141 UKH 95 95 250 1000 PA 3010013 UKH 150 150 335 1000 PA 3010110 UKH 240 240 453 1000 PA 3010217 MTK 2,5 15 380 PA 3101016 MTK-P/P 2,5 15 380 PA 3104013 UK4-T-P/P 2,5 16 500 PA 3042010 URELG 3 2,5 4) 250 PA 2820136 URELG 4 2,5 4) 250 PA 2820149 URELG 7 2,5 4) 250 PA 2820178 URELG 3-PMTK 4 10(4) 250 PA 2820709 URELG 4-PMTK 4 10(4) 250 PA 2820712 URELG 7-PMTK 4 10(4) 250 PA 2820725 1) Insulating material Polyamid 6.6 2) The rated voltage is of value for full insulated tabs. 3) Continous/limit current of the diode. 4) The current limit is determined by the relay. End cover, partition plate and separating plate to be used according to the Phoenix catalogue. Form No.: TA 1411a Issue: 2013-10 Page 3 of 5
Protective ground terminal block with screw terminal connection according to the following type designations: Type designation Cross section Ins. Material Cat.no. [mm 2 ] USLKG 1,5 N 1,5 PA 3005853 USLKG 2,5 N 2,5 PA 0441119 USLKG 6 N 6 PA 0442079 USLKG 10 N 10 PA 3003923 USLKG 16 N 16 PA 0443023 USLKG 3 2,5 PA 0441083 USLKG 4 4 PA 0441012 USLKG 5 4 PA 0441504 USLKG 10 10 PA 0442011 USLKG 16 16 PA 0443010 USLKG 35 35 PA 0444019 USLKG 50 50 PA 0443049 1) Insulating material Polyamid 6.6 End cover, partition plate and separating plate to be used according to Phoenix catalogue. Application/Limitation End cover, partition plate and separating plate to be used according to Phoenix catalogue. As to the workmanlike mounting, the accessories indicated in the Phoenix-catalogue shall be taken into consideration. Type Approval documentation Type designation Data sheet Dated DS-No MBKKB 2,5 EV-FEA/Ni/Schu 95.05.03 1239 Rev. 03 MT 1,5 EV-FEA/Krö/Schu 97.05.20 0415 Rev. 01 MT 1,5-PE EV-FEA/Krö/Schu 97.05.20 0662 Rev. 01 MT 1,5-TWIN EV-FEA/Krö/Schu 97.05.20 0425 Rev. 01 MT 1,5-TWIN-PE EV-FEA/Krö/Schu 97.05.20 0663 Rev. 01 MT 1,5-QUATTRO EV-FEA/Krö/Schu 97.05.20 0421 Rev. 02 MT 1,5-QUATTRO-PE EV-FEA/Krö/Schu 97.05.15 0664 Rev. 01 MTTB 1,5 EV-FEA/Krö/Schu 97.05.15 0417 Rev. 01 UK 1,5 N EV-FEA/Krö/Schu 97.11.05 0042 Rev. 06 UK 2,5 N EV-FEA/Ni/Schu 97.11.05 0808 Rev. 00 UK 5 N FEAL/Ni/Schu 94.07.26 0647 Rev. 05 UK 16 N EV-FEA/Krö/Schu 98.02.19 0272 Rev. 05 UK 5-RETURN FEAL/Ni/Schu 94.08.19 0376 Rev. 01 UK 5-RETURN-PE FEAL/Ni/Schu 94.12.20 0430 Rev. 01 UK 5-RETURN-PE-1 FEAL/Ni/Schu 94.12.20 0980 Rev. 00 ZFK 4-TG EV-FEA/Töb/Schu 95.07.04 0356 Rev. 00 Phoenix contact laboratory datasheet 2835-00-GB 201 0-04 Phoenix contact laboratory datasheet 3528-00-GB 2013-02 Phoenix contact test report no 3.01-3.15 26.10.-16.12.1983 Phoenix contact test report no 3.01.-3.13 06.01.1984 Phoenix contact test report no DS-No. 1163 FEAL/Ni/Schu rev. 7 20.05.1994 VDE Prüfbericht 4596-9000-4006/A2 Dr. Dg-th-me Form No.: TA 1411a Issue: 2013-10 Page 4 of 5
Bundesanstalt für Materialprüfung 3.2/3376/84 Phoenix contact test report 3.01.-3.15 Phoenix contact test report no. 3.0-3.13 Verband Deutcher Elektrotechniker (VDE) Prüfbericht 4596-9000-4006/A2 Dr. Dg-th-me Bundesanstalt für Materialprüfung 3.2/3376/84 Type designation Data sheet Dated DS-No Test Nos. *) USLKG 1,5 N EV-FEA/Krö/Schu 97.11.05 0807 Rev. 00 1) USLKG 2,5 N EV-FEA/Ni/Schu 97.06.20 0467 Rev. 05 2) & 3) USLKG 6 N EV-FEA/Krö/Schu 98.03.31 0416 Rev. 02 1) USLKG 10 N EV-FEA/Krö/Schu 98.04.28 0492 Rev. 02 1) USLKG 16 N EV-FEA/Ni/Schu 95.06.12 1081 Rev. 04 2) & 3) USLKG 3 EV-FEA/Ni/Schu 97.06.24 0468 Rev. 05 2) & 3) USLKG 5 EV-FEA/Ni/Schu 97.04.18 0279 Rev. 06 2) & 3) USLKG 50 EV-FEA/Ni/Schu 95.08.18 0573 Rev. 04 2) & 3) *) For description of tests carried out on the specific product, please see the section below. Tests carried out IEC 60947-7-1 (2002), IEC 60947-7-2 (2002) 1) IEC 947-7-2 (2002) 2) DIN VDE 0611-3 (1989-11) 3) IEC 17B (Sec) 446 (1992) (partly) Marking of product Phoenix Contact - Type designation - Main data. All type designation may be followed by suffix such as color or packaging options. Periodical assessment The scope of the periodical assessment survey is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the survey are: Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensuring traceability between manufacturer s product type marking and Type Approval Certificate. Survey to be performed at least every second year. END OF CERTIFICATE Form No.: TA 1411a Issue: 2013-10 Page 5 of 5