Instruction Manual. UVC AUTOMATIC HEADPHONE SANITIZER Portable Automatic Sanitizer. Never-Ending Learning Innovation

Similar documents
Instruction Manual. Model #: MPEN. 80 Little Falls Road, Fairfield, NJ Never-Ending Learning Innovation

Maintenance Instructions

Infrared LED Handheld Spotlight - Pistol Grip Spotlight w/ 16' Coil Cord - 3 Watt

UV-AIRE AIR PURIFYING SYSTEM

AvaLight-DHS Deuterium Halogen Light Source Operating manual

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

ROOM AIR SANITIZER GERMICIDAL ULTRAVIOLET ADVANTAGES OF THE SANITAIRE SYSTEM

LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

Further information: Berriman Associates Model 850P.2 Owners Manual

INSTALLATION TEMPLATE

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

PCR 6. Operators Manual. Vertical Laminar Airflow Cabinet with U.V. Sterilisation. Issue 05 September 2013

Luzchem Solar Simulator SolSim2 Updated September 2018

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

Installation Instructions

240 Watt Portable Work Area Light Tower - Extendable Tower W/ Wheels - (4) 60 Watt LED Lights

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

WARNING Risk of property damage, injury, or death.

Safety, Installation and Service Manual Models 1952, 1953 & 1972

5 Million Candlepower Handheld Spotlight- Red Hunting Lens Watt Halogen - Spot/Flood Combo

Conduit ~15" Inlet. UV Sterilizer - Connection to Forcemain

PROTECTOR FIBERGLASS ENCLOSURES

EZTRIM - Data and Specifications 2019

7-ASC / 8-ASC / 9-ASC

14W Linear 2' LED Light Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware

CJRK Tactical Riflescope Mount

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

ULTRAVIOLET LAMPS. PL Series UV Hand Lamps. Compact UV Lamps. Handheld UV Lamps

In This Section Portable Hot Box Aluminum For Transport J ER-18 Enclosed Rack For Display J

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Q-Series Ultraviolet Lamps OPERATOR S MANUAL

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

100W Magnetic Sealed Beam HIR Spotlight w/ Cig. Plug " Base - 12 Mil Candlepower - 750' Beam

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Ultraviolet Lamps. Compact UV Lamps. Handheld UV Lamps. Ultraviolet Lamps

MOBILE LEADED BARRIERS & SHELDS

Image Pro. Create eye-catching holiday displays or project personalized images. Image projection system

CeraLux Lamp Module Assembly Instructions

Installation Instructions

CeraLux Lamp Module Assembly Instructions

UNPACKING THE UNIT. Alcohol cleaning pad

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

TRAILBLAZER LIGHTING TRAILBLAZER LIGHTING

Instruction Manual. Fudge Puppy Display Case

1.0 F300S Ultraviolet Flood Exposure System

300 Watt Portable Work Area Light Tower - Extendible Tower W/ Wheels - (2) 150 Watt LED Lights

LightWave Lighting Technology

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

DOOR LIMITS A) ENGAGE CHAIN/BELT CONNECTOR TO CARRIAGE CAUTION B) CLOSE TRAVEL LIMIT

FOODSAFE IL INSTALLATION MANUAL

Bring power safely and conveniently to wherever

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

Rechargeable HID Handheld Light - RL-11

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

IMPORTANT: SAFETY INSTRUCTIONS

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight

MODEL 950C-NP-UV Installation and Owners Manual

VH03 SAVE THESE INSTRUCTIONS

18 Watt LED Spotlight with Magnetic Base - Articulating Light Head Tilting - IP65-25' Cord w/ Plug

INSTALLATION AND CUSTOMER CARE INFORMATION 80 SERIES & 90 SERIES TREATMENT STATIONS

ALU-29CF Portable Light NSN:

LT Charging Cart for Laptops

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

Lamps CERAMIC METAL HALIDE

Operating Instructions August 2013

Dispenser & Warmer RIC-1909 RIC-1909EXP

2. Description of Standard NUV Lightsource (350nm-450nm) 3 3. Description of Deep UV (220nm-280nm) and Mid UV (280nm-310nm) Lightsource Systems 3

HEPA AIR FILTRATION SYSTEM

OL100 VENTILATED DUMP STATION REFERENCE MANUAL. TM Coolidge Hwy. Oak Park, Michigan

TECHNICAL INFORMATION Puissant 30-Watt Shortwave UV Light Sources Catalog Nos. SKSUV30, SKSUV40

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

1000W High Intensity LED Crane Light - 110,000 Lumens V AC - Stainless Steel Bracket

OPK-300N OPTIMAX Multi-Lite

Depress each tab as you pull the bezel off. The bezels are tight. L.H. shown.

Installation instructions, accessories. Body kit

EQUIPMENT Operation Manual

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel

HLS Watt Halogen Illuminator Service Manual

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

MIATECH SOLUTIONS, A PIECE OF THE PUZZLE. Bio Turbo 300. Bio Turbo 1000

WK2Jeeps.com FASCIA, Front - Removal

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

PHOTO-CATALYTIC AIR PURIFIER SYSTEMS

CUTMASTER, Why TRUE? THREE YEAR WARRANTY. Thermal Dynamics Professional: When cutting and welding is your business WHEN YOU NEED IT.

Owner s Manual. PowerVerterDC-to-AC Inverter

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

OWNER'S MANUAL POWER BOOSTER. Rechargeable 12 Volt DC power supply. Item # Enclose copy of original sales receipt

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

FastPrep FP120 Cell Disrupter INSTRUCTION MANUAL

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL

Gavita. The most powerful lighting on the market

OPERATION MANUAL. Manual for GW2 2-port and GW3 3-port Dispensers. Java Creations Iced Coffee & Java Works Creamery Classics machines

3.6.1 Brake Lamp Switch

SERVING MEALS WITH TOAST APPEAL.

Envirco BIOLOGICAL SAFETY CABINET

Transcription:

Instruction Manual TM UVC AUTOMATIC HEADPHONE SANITIZER Portable Automatic Sanitizer Never-Ending Learning Innovation 80 Little Falls Road, Fairfield, NJ 07004 1-800-631-0868 www.hamiltonbuhl.com

Warning: Warnings and Precautions Device uses Ultra Violet Lamps. Direct exposure can cause eye damage. Do not look directly at light. Do not operate without HEPA filters installed. WARNING UV LIGHT DO NOT LOOK DIRECTLY AT LIGHT UV! WARNING UV Light Hazard. Avoid looking directly at light 254 nm Product Description The HB Portable Automatic Sanitizer is a unique apparatus that automatically sanitizes headphones and small electronics with UVC radiation while they are not in use and safely out of the way. The equipment can be wall mounted or supplied in a special hand carry case. During the sterilization cycle, UVC light both direct and reflected off reflectors in each cage, passes though the cage and impinges on the headphone surfaces to sanitize them. During the sanitizing process the case is absolutely closed and is kept closed by built-in electronic latches. The sanitation process is fully automatic and fast, preset by a built-in timer, usually a minute or two, during which 99%+ of harmful pathogens get eliminated. Specification and Features Size: 22.75 L x 18.5 W x 8.6 H Weight: 21 lbs. unloaded - 28 lbs. loaded Power: 180 watt - input 120V. 60Hz Germicidal lamps: (4) 36 watt, T6, UVC 9000 HR life Filter: H10 HEPA, size 7.5 x 3.5 x 0.8 Operation: Auto start with timing relay cycle control Auxiliary AC outlet: 10 amp, 125 volt Safety: Dual interlock with magnetic lock - 20 lbs. holding force Input: 120v. 60Hz 2

Line cord: 12 foot IEC detachable stored in case Operation: Auto start with timing relay cycle control Storage compartments: 3 cul Pending/Patent Pending Rugged Portable Carry Case Design with Aluminum Components Rolling carry handle Safety Note Before doing any maintenance on the HygenX Sanitizer, always unplug the line cord. Care and Cleaning The HygenX Sanitizer is of durable construction but the UVC lamps are prone to breakage with excessive handling of the case. Avoid heavy impacts or dropping the case to prevent lamp damage. Cleaning the unit with soft cloth is recommended. Product Description 1. The HygenX Sanitizer is simple to use. Open the unit and remove the line cord and connect to the external connector. Place unit on stable surface and locate the unit within a safe distance for the line cord to be connected easily. 3

2. Place headphone to be sanitized onto one of the two racks provided as shown. Place headphones starting from back of rack moving towards front. It is recommended to drape the headphone line cords over the headphones to promote effective sanitation of all surfaces. 3. Once loaded make sure the unit plugged in for power and close completely (The unit will automatically turn on which is indicated by the sound of the fan operation and indicator light in the front of the unit) During the operation, the magnetic lock will retain the unit closed until the sanitizing cycle is complete (approximately 2 minutes). When the cycle is done, the unit automatically turns off allowing the case to be opened and reloaded for another group or just left stationary until needed. During periods of non-use, you should keep the case latches engaged and the unit unplugged. 4

Filter Replacement 1. The two HEPA filters are accessed from inside the case and can be removed by sliding them out of their holder. The intake filter can be removed by inserting a screw driver or small rod into the access hole located under the filter. The exhaust filter can be removed by sliding it out of the holder. Note: Do not operate the sanitizer without filters. Lamp Replacement 1. In the event a lamp needs to be replaced, unplug and open the case. To get access to the lamp, remove the cage by pushing down on the cage in the area of the tabs retaining the cage (image). When free, remove for clear lamp access. Pivot the lamp out of the retainer and pull out as shown (image). To install new lamp follow removal procedure in reverse. 5

Adding Rolling Attachment 1. Place the case in the vertical standing position. To attach the rolling handle, place the wheels with the nesting track facing the mounting rail extending off the lower part of the case. 2. Make sure the case rail engages from the top into the nesting track and then pivot the handle toward the case to allow the top handle track to connect with the upper rail on the case. 3. When the handle is fully against the body of the case, you can complete the attachment by pushing the extended locking latch downward the wheels until it snaps into place. 6

Removing Rolling Attachment 1. To remove the rolling handle press the tabs together on the opposite side of the latch. This is spring loaded and will release the handle from the upper rail allowing the rolling handle to be removed. Product Registration Instructions Visit: www.hamiltonbuhl.com WARRANT Y 1. Click on Customer Care 2. Click on Product Registration Icon 3. Please fill out all fields marked with * to register Warranty: Warranty begins the date item ships from our warehouse. All products, except for metal carts, have a one year warranty from original date of shipment, unless otherwise noted. Metal carts have a limited lifetime warranty on all housing components; however, carts have a one year warranty on any electrical / mechanical components. Our Mission: Since our founding in 1933, HamiltonBuhl continues to evolve as a leader in technology products for education and industry. Our products are embraced by educators, corporate trainers, presenters, government agencies, and hospitals for their daily presentation, from the classroom to the boardroom, HamiltonBuhl has the presentation product for you. 7

Never-Ending Learning Innovation 80 Little Falls Road, Fairfield, NJ 07004 1-800-631-0868 www.hamiltonbuhl.com HygenX-UVC 12/2016 v.1