Suction Filters S8-455 SE56-560

Similar documents
High-pressure inline filter, flangeable

Inline filter. Features RE 51401/ Types 40 FLEN 0160 to 1000; 40 FLE 0045, 0055, 0120 to 0270

Replacement cartridge filter

Block mounting filter, lateral flange-mounting possible

Line filter. Features. RE 51400/01.09 Replaces: Types 40/100 LEN 0040 to 0400; 40/100 LE 0003, 0015, 0018

VacuClean Systematic Oil Treatment Patented

Low / Medium Pressure Duplex Filter Inline mounting. Type : 40/160-LD/LDN. Filters. Accumulators. Hydraulic Symbol. Technical Data

LowViscosity Housing Filter LVH-F

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

DT-350 In-Line Hydraulic Filter

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Change-Over Inline Filter AFLD to API 614

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Change-Over Pressure Filter DFDK

Breather filter. RE 51414/02.09 Replaces: Types BF 7 SL ; BS 7 SL ; BE 7 SL ; B 7 SL

LIQUID PURIFICATION SYSTEMS FLUSHING SYSTEMS & SERVICES

Process screen basket filter PRFS

Process Inline Filter Medium / High Pressure PFM / PFH

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Return Line Filter RF

Change-Over Inline Filter RFLD Welded Version

Pressure Filter DF...K P, DF...M P, Flange Mounted

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Oil Filter Module Pi 8300

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Oil Filter Module Pi 8300

Process Multi-Rheo Filter PMRF

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Inline Filter DMG DMG 080 DMG 045 DMG FILTER SPECIFICATIONS. Temperature range -10 C to +100 C Material of filter housing

Off-line Oil Filter Module Pi 8400

Return line and Suction Boost Filter RKM

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

Duplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100

Return Line Filter RF

ES 094 Tank top mounting Connection up to G1¼ Nominal flow rate up to 70 l/min

LMP series

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

Flow rates to 500 l/min

Duplex Filter Pi Features. Nominal pressure 25 bar (360 psi), nominal size 800 and 1400

Block mounting filter, for lateral flange-mounting

In line high pressure filters. HF 735 series

D e s c r i p t i o n

Process Inline Filter Protective filter PLF2-9HF

Line filter with filter element according to DIN 24550

MultiRheo Filter MRF 1/2/3/4/5/6/7

High Pressure Filter Pi 4230

Line filter Pi Features. Nominal pressure 16 bar (230 psi), nominal size 400 up to 6000

In line high pressure filters. HF 725 series

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

D e s c r i p t i o n

Return Line Filter RFM with 4-Hole Mounting

Series RFLD Duplex In-Line Filter

Process Inline Filter PLF1

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

Low Pressure Filter Pi 2000/Pi 2200

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

Change-Over Inline Filter RFLD Weld Version

NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports

Mobile Filter Units Pi 8100

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Duplex Filter Pi Features. Nominal pressure 10/16 bar (140/230 psi), nominal size 1250 up to 8000

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

NFH Low Pressure Filters

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

Series RFL In-Line Filter

Block mounting filter, for lateral flange-mounting

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Block mounting filter, for vertical flange-mounting

SRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction

MultiRheo Filter MRF 1/2/3/4/5/6/7

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

High Pressure Filter Pi 4230

Inline filter with filter element according to DIN 24550

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min

PRESSURE FILTER Series HPV DN 25 PN 420

Inline filter with filter element according to DIN 24550

HPK04 Max Flow: 120 gpm (454 lpm)

Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

HIGH PRESSURE FILTERS

LowViscosity Housing- Coalescer Diesel LVH-CD

Automatic back-flushing filter AutoFilt RF4

Return Line Filter RFM with 4-Hole Mounting

HIGH PRESSURE FILTERS

Transcription:

Industrial Filters ccumulators uction Filters 8-5 E56-56 Filters for installation in suction pipes uctions filters with housing for tank mounting uction filters with housing including automatic shut off valve. Nominal flow rate: 15-1 l/min up to E 4 Low pressure drop filter media available Quality assured!

uction Filters Performance Characteristics Oil viscosity 3,2 mm /sec 2 drop curves for wire mesh G 1 8-5 E56-56 Nominal flow rate: 15-1 l/min Operating temperature: -1 C up to +1 C up to E 4 pplication Filtration of liquids and lubricants. Filtration of liquids and gases. Filtration of industrial liquids. Direct installation in suction lines or tank mounting installation. specific gravity <,9 kg/dm3 Ordering Information Filter ssembly Kit E D E Nominal ize Type: 56 14 225 36 46 56 ccessories s For monitoring the filter element's contamination status, visual and visual/electrical indicators, with one or two switching points are available. Bypass Valve 8-5: bypass valve available E56-56: standard bypass valve with opening pressure of,3 bar included. To protect the pump against cavitation during start up and over pressurisation due to clogging. G 25 G 25 Nominal ize 8,, 175, 16, 75, 28, 28, 115, 5 = pipe thread = E flange F = square flange = standard 1... = standard adhesive T = 1 C O P O P = P= Buna N V= Viton for always for Filter Element always = standard Design Bypass Valve... = standard adhesive T = 1 C 1 =,3 bar C visual/electrical B,2 = l,2 H 32 P* C.2 = l,2 H 32 P* witching symbol witching symbol O = = V= non return valve,2 bar ize Volume Weight 1 in ltrs. in kg 1) 8 16 8-5 28 75 115 175 28 5 E 56 E E 14 E 225 E 36 E 46 E56 1) *P = Buna N, V = Viton also possible E 225, E 36, E 46, E 56 Filter witching ymbol B visual/electrical E 56, E, E 14 = standard E 56-56 = M 7 Dimensions 1 =,3 bar visual = Y= with add. strainer only for E 36 to E 56 on request G 13 G25 G4 G 13 G 2 G 25 G 3 G 35 G G 55 G 6 G 8 G 1 G 15 G 2 Design Bypass Valve... = standard material = uction Filter H1L G25 G4 G6 G8 V = nonwoven media, not cleanable V 25 V 4 V 8 P = paper, not cleanable P5 P1 P25 bsolute filtration grade (IO72)in µm H...L = micro glass-fibre, not cleanable H1L H3L H6L H1L H2L = micro glass-fibre, water absorbing, not cleanable 1 3 6 1 2 Filter ssembly = vacuum gauge B,2 = vacuum switch C,2 = vacuum switch 8, 16, 28,, 75, 1 15 175, 28, 5 Pleated design with optimised pleat density and various filter media. The filter element is the most important component of the filter in view of prolonged life and wear protection of the system. Oil cleanliness, the initial pressure drop and the dirt holding capacity are the most important criteria for selection. For further detailed information please refer our "s" brochure. proper filter selection is enabled by our "EPE - FILTERELECT" software. election of filter size: using the computer program "EPE - FILTERELECT or performance characteristics in this brochure. pecial designs available on request. Design 8-5 with pleated filter element an pipe thread connection. E56-56: filter head with screwable cover, bypass valve and outlet. Filter housing with filter element locator, filter inlet and return flow blockage for element service. : as per spare parts list in this brochure. E = uction Filter with housing 2),5,2,4,5,6,7 1,7,5,8 1,9 3,7 4, 4,8 1, 1,2 3, 7,5 8,7 9,1 6 2 3 2) 4 B1 B2 B3 B4 B5 B6 B7 B8 C1 C2 C3 C4 C5 C6 D1 Tank-Bore 12 13 35 95 17 6 13 135 21 54 18 17 28 25 125 96 22 32 18 266 119 31 42 281 155 31 188 361 58 24 ø 4 36 ø 57 55 ø 77 75 ø 18 15 ø 15 115 7 65 137 142 78 77 8 12 = weight including standard filter element = servicing height for filter element replacement ø 95,5 51 166 28 ø 74 89 112 14 146 17 77,8 154 13,2 ø 13 G 3/8 G 1/2 G 3/4 G 11/4 G 11/2 G2 G3 ø 11 G 11/2 ø11,5 M 12 ø12 DN 8 ø11 22 E4 M 16 ø1 3 psi

uction Filters Performance Characteristics Oil viscosity 3,2 mm /sec 2 drop curves for wire mesh G 1 8-5 E56-56 Nominal flow rate: 15-1 l/min Operating temperature: -1 C up to +1 C up to E 4 pplication Filtration of liquids and lubricants. Filtration of liquids and gases. Filtration of industrial liquids. Direct installation in suction lines or tank mounting installation. specific gravity <,9 kg/dm3 Ordering Information Filter ssembly Kit E D E Nominal ize Type: 56 14 225 36 46 56 ccessories s For monitoring the filter element's contamination status, visual and visual/electrical indicators, with one or two switching points are available. Bypass Valve 8-5: bypass valve available E56-56: standard bypass valve with opening pressure of,3 bar included. To protect the pump against cavitation during start up and over pressurisation due to clogging. G 25 G 25 Nominal ize 8,, 175, 16, 75, 28, 28, 115, 5 = pipe thread = E flange F = square flange = standard 1... = standard adhesive T = 1 C O P O P = P= Buna N V= Viton for always for Filter Element always = standard Design Bypass Valve... = standard adhesive T = 1 C 1 =,3 bar C visual/electrical B,2 = l,2 H 32 P* C.2 = l,2 H 32 P* witching symbol witching symbol O = = V= non return valve,2 bar ize Volume Weight 1 in ltrs. in kg 1) 8 16 8-5 28 75 115 175 28 5 E 56 E E 14 E 225 E 36 E 46 E56 1) *P = Buna N, V = Viton also possible E 225, E 36, E 46, E 56 Filter witching ymbol B visual/electrical E 56, E, E 14 = standard E 56-56 = M 7 Dimensions 1 =,3 bar visual = Y= with add. strainer only for E 36 to E 56 on request G 13 G25 G4 G 13 G 2 G 25 G 3 G 35 G G 55 G 6 G 8 G 1 G 15 G 2 Design Bypass Valve... = standard material = uction Filter H1L G25 G4 G6 G8 V = nonwoven media, not cleanable V 25 V 4 V 8 P = paper, not cleanable P5 P1 P25 bsolute filtration grade (IO72)in µm H...L = micro glass-fibre, not cleanable H1L H3L H6L H1L H2L = micro glass-fibre, water absorbing, not cleanable 1 3 6 1 2 Filter ssembly = vacuum gauge B,2 = vacuum switch C,2 = vacuum switch 8, 16, 28,, 75, 1 15 175, 28, 5 Pleated design with optimised pleat density and various filter media. The filter element is the most important component of the filter in view of prolonged life and wear protection of the system. Oil cleanliness, the initial pressure drop and the dirt holding capacity are the most important criteria for selection. For further detailed information please refer our "s" brochure. proper filter selection is enabled by our "EPE - FILTERELECT" software. election of filter size: using the computer program "EPE - FILTERELECT or performance characteristics in this brochure. pecial designs available on request. Design 8-5 with pleated filter element an pipe thread connection. E56-56: filter head with screwable cover, bypass valve and outlet. Filter housing with filter element locator, filter inlet and return flow blockage for element service. : as per spare parts list in this brochure. E = uction Filter with housing 2),5,2,4,5,6,7 1,7,5,8 1,9 3,7 4, 4,8 1, 1,2 3, 7,5 8,7 9,1 6 2 3 2) 4 B1 B2 B3 B4 B5 B6 B7 B8 C1 C2 C3 C4 C5 C6 D1 Tank-Bore 12 13 35 95 17 6 13 135 21 54 18 17 28 25 125 96 22 32 18 266 119 31 42 281 155 31 188 361 58 24 ø 4 36 ø 57 55 ø 77 75 ø 18 15 ø 15 115 7 65 137 142 78 77 8 12 = weight including standard filter element = servicing height for filter element replacement ø 95,5 51 166 28 ø 74 89 112 14 146 17 77,8 154 13,2 ø 13 G 3/8 G 1/2 G 3/4 G 11/4 G 11/2 G2 G3 ø 11 G 11/2 ø11,5 M 12 ø12 DN 8 ø11 22 E4 M 16 ø1 3 psi

uction Filters Performance Characteristics Oil viscosity 3,2 mm /sec 2 drop curves for wire mesh G 1 8-5 E56-56 Nominal flow rate: 15-1 l/min Operating temperature: -1 C up to +1 C up to E 4 pplication Filtration of liquids and lubricants. Filtration of liquids and gases. Filtration of industrial liquids. Direct installation in suction lines or tank mounting installation. specific gravity <,9 kg/dm3 Ordering Information Filter ssembly Kit E D E Nominal ize Type: 56 14 225 36 46 56 ccessories s For monitoring the filter element's contamination status, visual and visual/electrical indicators, with one or two switching points are available. Bypass Valve 8-5: bypass valve available E56-56: standard bypass valve with opening pressure of,3 bar included. To protect the pump against cavitation during start up and over pressurisation due to clogging. G 25 G 25 Nominal ize 8,, 175, 16, 75, 28, 28, 115, 5 = pipe thread = E flange F = square flange = standard 1... = standard adhesive T = 1 C O P O P = P= Buna N V= Viton for always for Filter Element always = standard Design Bypass Valve... = standard adhesive T = 1 C 1 =,3 bar C visual/electrical B,2 = l,2 H 32 P* C.2 = l,2 H 32 P* witching symbol witching symbol O = = V= non return valve,2 bar ize Volume Weight 1 in ltrs. in kg 1) 8 16 8-5 28 75 115 175 28 5 E 56 E E 14 E 225 E 36 E 46 E56 1) *P = Buna N, V = Viton also possible E 225, E 36, E 46, E 56 Filter witching ymbol B visual/electrical E 56, E, E 14 = standard E 56-56 = M 7 Dimensions 1 =,3 bar visual = Y= with add. strainer only for E 36 to E 56 on request G 13 G25 G4 G 13 G 2 G 25 G 3 G 35 G G 55 G 6 G 8 G 1 G 15 G 2 Design Bypass Valve... = standard material = uction Filter H1L G25 G4 G6 G8 V = nonwoven media, not cleanable V 25 V 4 V 8 P = paper, not cleanable P5 P1 P25 bsolute filtration grade (IO72)in µm H...L = micro glass-fibre, not cleanable H1L H3L H6L H1L H2L = micro glass-fibre, water absorbing, not cleanable 1 3 6 1 2 Filter ssembly = vacuum gauge B,2 = vacuum switch C,2 = vacuum switch 8, 16, 28,, 75, 1 15 175, 28, 5 Pleated design with optimised pleat density and various filter media. The filter element is the most important component of the filter in view of prolonged life and wear protection of the system. Oil cleanliness, the initial pressure drop and the dirt holding capacity are the most important criteria for selection. For further detailed information please refer our "s" brochure. proper filter selection is enabled by our "EPE - FILTERELECT" software. election of filter size: using the computer program "EPE - FILTERELECT or performance characteristics in this brochure. pecial designs available on request. Design 8-5 with pleated filter element an pipe thread connection. E56-56: filter head with screwable cover, bypass valve and outlet. Filter housing with filter element locator, filter inlet and return flow blockage for element service. : as per spare parts list in this brochure. E = uction Filter with housing 2),5,2,4,5,6,7 1,7,5,8 1,9 3,7 4, 4,8 1, 1,2 3, 7,5 8,7 9,1 6 2 3 2) 4 B1 B2 B3 B4 B5 B6 B7 B8 C1 C2 C3 C4 C5 C6 D1 Tank-Bore 12 13 35 95 17 6 13 135 21 54 18 17 28 25 125 96 22 32 18 266 119 31 42 281 155 31 188 361 58 24 ø 4 36 ø 57 55 ø 77 75 ø 18 15 ø 15 115 7 65 137 142 78 77 8 12 = weight including standard filter element = servicing height for filter element replacement ø 95,5 51 166 28 ø 74 89 112 14 146 17 77,8 154 13,2 ø 13 G 3/8 G 1/2 G 3/4 G 11/4 G 11/2 G2 G3 ø 11 G 11/2 ø11,5 M 12 ø12 DN 8 ø11 22 E4 M 16 ø1 3 psi

pare Parts ize 56 14 225 36 46 56 Part Qty. Designation 1 1 2 1 3 1 4 1 5 1 6 1 7 1 Filter cover Filter head Filter element Profile seal Profile seal O-ring Plug Reduction for M 7 Buna N/Viton Buna N/Viton please indicate ordering information " Kit" 5.8 Part No. 7 Part No. 77 8 1 refer section "" please indicate ordering information " Kit" 9 1 1 1 11 1 12 1 Duplex fitting for I... Pressing with valve plastic luminium cast Fibre teel teel please indicate ordering information "Filter ssembly" please indicate ordering information "Filter ssembly" please indicate ordering information "" please indicate ordering information " Kit" please indicate ordering information " Kit" Part No. 1372 Part No. 1371 please indicate ordering information "Filter ssembly" Quality and tandardisation The development, manufacturing and assembly of EPE Industrial filters and filter elements is performed within the guidelines of a certified quality management system according to DIN EN IO 1. The calculation of strength and the filter tests are done in compliance to actual pressure vessel regulations and national & international standards. filter inspection by accredited certification bodies ( e.g. TÜV, GL, LR, LRI, B, BV, DNV, DRIRE, UDT etc. ) is possible on request.

Industrial Filters ccumulators Installation, tarting and Maintenance Filter Installation crew suction filter type 8-5 direct on pump suction line. Type E 56-56: remove dust protection plug from filter inlet. Mount filter assembly at tank using mounting device on the head (Part 2) considering and servicing length required for cleaning / replacing elements (Part 3 ). of Electrical Type: E 56-56: Connect indicator using the two wired cable. Please verify electrical ratings on the indicators name plate. tarting witch on system pump. Pay attention to pump noise, dismount filter assembly if necessary and check filtration grade and seals. Maintenance The filter element is clogged and needs to be replaced or cleaned if the vacuum gauge indicator moves into red alert range or the electrical switch is activated. ervice 8-5: switch off system, drain tank, disconnect suction filter from suction line. E 56-56: switch off system pump. Unscrew filter cover (Part 1), return flow blockage closes automatically, remove filter element from filter housing. Check filter housing inside and clean if necessary. Replace filter element H..-L, P... and V.... The filter element with G... media is cleanable. The efficiency of the cleaning process depends on the characteristics of contamination and the final pressure drop prior to servicing / cleaning the element. Install cleaned or replaced filter element. Check O-ring (Part 6 ) on filter head, replace in case of damage or wear. crew filter cover (Part 1) and tighten it at hexagon bolt using a suitable tool. Operate filter as described above. K. & H. Eppensteiner GmbH & Co. KG Hardtwaldstraße 43 D-68775 Ketsch/Rh. Postfach 112 D-68768 Ketsch/Rh. Telefon: 62 2 / 6 3- Telefax: 62 2 / 6 3-199 E-Mail: Eppensteiner@compuserve.com Internet: www.eppensteiner.de Technical modifications reserved! 2/1/1.99/6