New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

Similar documents
New Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series

2 port pilot operated solenoid valve

Free position locking flat and compact cylinder UFCD Series

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

Energy efficiency and Flow

PD3/PDV3-20A/25A/40A Series

Balancing Unit BBS Series

HN B G1/US B G2/US B G3

Mechanical power cylinder

Super-Mini Complete with Easy-to-Use Functions. Guided Cylinder. STM Series GUIDED CYLINDER STM SERIES CC-884A 1

Light weight clamp cylinder CAC-N32/40 Series Light weight position locking clamp cylinder UCAC-N32/40 Series

New Products. Speed Control Valve with Adjusting Dial. DSC series SPEED CONTROL VALVE WITH ADJUSTING DIAL DSC SERIES. Visible Flow Rate!

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type

NO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

CVE2/CVSE2 CVE3/CVSE3

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

General purpose direct acting 2, 3 port solenoid valve

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

3 Port Solenoid Valve Direct Operated Poppet Type

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

AB41E4-Z Series. Pressure and explosion proof structure d2g4 (flame-proof grade 2, ignitability G4) NC (normally closed) type. Port size: Rc1/4, Rc3/8

Features. Maintenance is simplified with the separable scraper section adapter.

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Pilot Operated 2 Port Solenoid Valve for Dry Air

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

Pilot operated 2 port valve for dust collector control (pulsejet valve) Common specifications Air operated type. Solenoid valve mounted type Item OUT

Plug-in manifold W4G4 Series

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

Conventional specification. External Pilot air specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Pilot Operated 2 Port Solenoid Valve for Dry Air

2/2-way Solenoid Valve for liquids and gases

INSTRUCTION MANUAL FOR

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Series AV2000/3000/4000/5000

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Soft Start-up Valve. AV2000/3000/4000/5000 Series

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Vacuum pump system type

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Large flow rate with compact body

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

GUIDED CYLINDER STG SERIES

Exclusively for air pressure system and air-hydro circuit control

Series VP3145/3165/3185

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Direct acting 3-port valve 3Q Series

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Process Valve/Series VN

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

High Pressure Coolant Valve

Motorized Two-Way Ball Valve with Screwed-End Connection

Series variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance

SOLENOID VALVES SERIES

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Rubber Seal VP300/500/700

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Air Operated/External Pilot Solenoid

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

Exhaust Throttle (Needle) Valve ET

PDVE4 Series PDVE4 20A 3T AC100V. Explosion proof 2 port solenoid valve for dust collector control (explosion proof pulsejet valve)

ACTIVAL Two-way Ball Valve with Threaded-end Connection

SVR10 SVA10. External Pilot air specification. Conventional specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

Series VXR21/22/23. Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve. For Water and Oil

Compact direct acting precision regulator

Design and selection. Installation and adjustment

Speed Controller High Flow

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Digital display Pressure range ON/OFF output Linear output Model

Discrete air operated 2 port valve (compact cylinder valve) NC (normally closed) type

Transcription:

New Products Compact Pilot Operated Solenoid Valve for Water FWD Series New Product COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER Lightweight and large flow rate, low power consumption Improved corrosion resistance! 1/3 Reduced by (CKD comparison) PILOT OPERATED SOLENOID VALVE FOR WATER Refer to "Safety Precautions" on the rear side before use. CC-107A 3

Product lineup expanded to 2A! Eco-friendly CKD solenoid valve Ecology Low power consumption Power consumption Power consumption reduced to 4w! (DC) Compact and lightweight Product size 6 38 91mm (1A) Reduced by 1/3 (CKD comparison) Reduced by 1/3 (CKD comparison) Weight 390g (1A) Reduced by 1/3 (CKD comparison) Specially designed for water Improved corrosion resistance Uses specialized high corrosion proof magnetic material to improve corrosion resistance. Body material Brass (bronze) or stainless steel are available. Large flow rate Specially formed diaphragm provided Specially formed diaphragm enables handling of large flow despite its compact size Cv flow factor 6.0 (1A)

Compact Pilot Operated Solenoid Valve for Water XXXXX Series FWD Series NC (Normally closed) Port size: Rc1/4 to Rc1 Specifi cations Descriptions FWD11-8A FWD11-10A FWD11-1A FWD11-20A FWD11-2A Actuation Working fl uid NC (normally closed) Water (other than sewage, agricultural water, liquid manure, antifreeze) Working pressure differential range MPa 0.02 to 0.7 Max. working pressure MPa 0.7 Pressure resistance (water) MPa 1.0 Fluid temperature to 60 (no freezing) Ambient temperature -10 to 60 (no freezing of fl uid) Atmosphere Area without corrosive or explosive gases Valve structure Pilot operated poppet structure diaphragm structure Valve seat leakage cm 3 /min 0 (water pressure) (Note 1) Installation attitude Free Protection property IPX Port size Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 Orifi ce mm 1 (Note 2) 22 (Note 2) Cv fl ow factor 2.8 4.2 6.0 11.0 12.0 Weight g 340 320 390 730 90 Rated voltage 100VAC 0/60Hz, 200VAC 0/60Hz, 24VDC Allowable voltage fluctuation Rated voltage ±10% Apparent power VA At holding (0/60Hz): /4, at starting (0/60Hz): 9/8 At holding (0/60Hz): 9./7, at starting (0/60Hz): 23/20 Power consumption W AC(0/60Hz): 2.7/2, DC: 4 AC(0/60Hz): 4/3.2, DC: 4 Coil heat resistance class B Note 1: "Valve seat leakage 0 cm 3 /min" means that no water drip leaks for a minute. Note 2: Orifi ce diameter refers to the diameter of the valve seat section. 3

FWD Series How to order FWD11 1 A 0 2GS B AC100V Model no. A Port size B Thread type Note on model no. selection Note 1: For port size 8, 10, 1; refer to Pg 9. For port size 20, 2; refer to Pg11. Note 2: The rated voltage includes 110VAC 0/60 Hz and 220VAC 0/60 Hz. Contact CKD for more information. <Example of model number> FWD11-1A-02GSB-AC100V A Port size : 1/2 Internal structure and parts list C Body/sealant combination D Coil option E Mounting plate B Screw type : Rc screw C Body/sealant combination : Brass / PPS, NBR D Coil option : DIN terminal box with surge suppressor (pg 9) E Mounting plate : Mounting plate F Rated voltage : 100VAC 0/60 Hz, 110VAC 60 Hz F Rated voltage Note 2 Symbol A Port size FWD11-8, 10, 1 FWD11-20, 2 1 2 3 4 8 1/4 10 3/8 1 1/2 20 3/4 2 1 B Thread type A G N Rc G NPT C Body/sealant combination Body Description Seal 0 Brass / PPS (Port size: 8,10,1) Bronze / PPS (Port size: 20,2) NBR D Stainless steel/ PPS NBR D Coil option 2C Grommet lead wire 2CS Grommet lead wire with surge suppressor 2G With DIN terminal box (Note 1) 2GS DIN terminal box / with surge suppressor (Note 1) 2H DIN terminal box with light (Note 1) 2HS DIN terminal box and light, surge suppressor (Note 1) E Mounting plate Blank None B Mounting plate (Port size: only 8,10,1 are available) F Rated voltage AC100V 100VAC 0/60Hz, 110VAC 60Hz AC200V 200VAC 0/60Hz, 220VAC 60Hz DC24V 24VDC 1 2 3 4 9 6 7 8 9 10 11 6 7 10 11 12 12 13 8 13 4 No. Parts name Material No. Parts name Material 1 Core assembly SUS Stainless steel 8 Filter SUS Stainless steel 2 Shading coil *1 Cu (Ag for stainless steel body) Copper (Silver for stainless steel body) 9 Valve spring SUS Stainless steel 3 Coil Port size: 8,10,1; PPS/ NBR Polyphenylene sulfide/ nitrile rubber 10 Diaphragm assembly 4 Plunger SUS NBR Stainless, nitrile rubber Port size: 20, 2; SUS/NBR Stainless steal/ nitrile rubber Holder plate PPS Polyphenylene sulfi de 11 Valve body PPS Polyphenylene sulfide 6 Plunger spring SUS Stainless steel 12 Gasket NBR Nitrile rubber 7 Stuffi ng Assembly PPS SUS NBR Items inside parentheses are optional *1: Shading coil will not be used for DC coil. Polyphenylene sulfi de/ stainless steal/ nitrile rubber 13 Main body Port size: 8, 10, 1; C3771 (SCS13) Brass (stainless steel) Port size: 20, 2; CAC408 (SCS13) Bronze (stainless steel) Note: Material of thread is steel.

Dimensions (Port size 8A, 10A, 1A) FWD Series Dimensions Grommet lead wire type FWD11-8A/10A-*2C FWD11-1A-*2C 1. 19. 22 1. 19. 22 4 2-M depth 8 11 63. 8 18 38 2-A 6 2-M depth 8 28 14 66. 91 27 38 2-Rc1/2 Model no. A FWD11-8A Rc 1/4 FWD11-10A Rc 3/8 Dimensions with options (Port size 8A, 10A, 1A) Grommet lead wire with surge suppressor With DIN terminal box FWD11-8A/10A/1A-*2CS FWD11-8A/10A/1A-*2G/2GS/2H/2HS 26. 3 44 (38) Pg9 Mounting plate FWD11-8A/10A-**B 2 8 FWD11-1A-**B 2 8 62 0 70 8 2-ø6 2-ø6

FWD Series Dimensions (Port size 20A, 2A) Grommet lead wire type FWD11-20A-*2C FWD11-2A-*2C 18. 22. 28 18. 22. 28 80 32 2-Rc3/4 41 2-Rc1 3 3 Dimensions with options (Port size 20A, 2A) Grommet lead wire with surge suppressor With DIN terminal box FWD11-20A/2A-*2CS FWD11-20A/2A-*2G/2GS/2H/2HS 29. 8. 47 (42) 16. 20 91 118. 9 126 90 Pg11 6

Safety precautions Always read this section before starting use. When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured. It is important to select, use, handle, and maintain the product appropriately to ensure that the CKD product is used safely. Observe warnings and precautions to ensure device safety. Check that device safety is ensured, and manufacture a safe device. WARNING 1 This product is designed and manufactured as a general industrial machine part. It must be handled by an operator having suffi cient knowledge and experience in handling. 2 Use this product in accordance of specifi cations. This product must be used within its stated specifications. It must not be modifi ed or machined. This product is intended for use as a general-purpose industrial device or part. It is not intended for use outdoors or for use under the following conditions or environment. (Note that this product can be used when CKD is consulted prior to use and the customer consents to CKD product specifi cations. The customer must provide safety measures to avoid risks in the event of problems.) (1) Use for special applications including nuclear energy, railway, aircraft, marine vessel, vehicle, medicinal devices, devices or applications coming into contact with beverages or foodstuffs, amusement devices, emergency cutoff circuits, press machines, brake circuits, or safety devices or applications. (2) Use for applications where life or assets could be adversely affected, and special safety measures are required. 3 Observe corporate standards and regulations, etc., related to the safety of device design and control, etc. ISO4414, JIS B 8370 (pneumatic system rules) JFPS2008 (principles for pneumatic cylinder selection and use) Including High Pressure Gas Maintenance Law, Occupational Safety and Sanitation Laws, other safety rules, body standards and regulations, etc. 4 Do not handle, pipe, or remove devices before confi rming safety. (1)Inspect and service the machine and devices after confirming safety of the entire system related to this product. (2)Note that there may be hot or charged sections even after operation is stopped. (3) When inspecting or servicing the device, turn off the energy source (air supply or water supply), and turn off power to the facility. Discharge any compressed air from the system, and pay enough attention to possible water leakage and leakage of electricity. (4) When starting or restarting a machine or device that incorporates pneumatic components, make sure that the system safety, such as pop-out prevention measures, is secured. Observe warnings and cautions on the pages below to prevent accidents. The precautions are ranked as "DANGER", "WARNING" and "CAUTION" in this section. DANGER: When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries, or when there is a high degree of emergency to a warning. WARNING: When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries. CAUTION: When a dangerous situation may occur if handling is mistaken leading to minor injuries or physical damage. Note that some items described as "CAUTION" may lead to serious results depending on the situation. In any case, important information that must be observed is explained. Limited Warranty and Disclaimer 1 "Warranty Period" is one (1) year from the fi rst delivery to the customer. 2 In case any defect attributable to CKD is found during Warranty Period, CKD shall, at its own discretion, repair the defect or replace the relevant product in whole or in part, according to its own judgment. In no event CKD shall never be liable for the costs in relation to and the damages resulting from the (de) installation of the product. This Limited Warranty will not apply to: (1) Product abuse/misuse contrary to conditions/environment recommended in its catalogs/specifi cations. (2) Failure due to other causes. (3) Use other than original design purposes. (4) Third-party repair/modification. () Failure due to causes not foreseeable with technology at the time of delivery. (6) Failure attributable to force majeure. 3 4 IN NO EVENT SHALL CKD BE LIABLE FOR BUSINESS INTERRUPTIONS, LOSS OF PROFITS, PERSONAL INJURY, COSTS OF DELAY OR FOR ANY OTHER SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL LOSSES, COSTS OR DAMAGES. IN NO EVENT SHALL CKD BE LIABLE FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, notwithstanding any disclosure to CKD of the use to which the product is to be put. 7

Safety precautions Fluid control components: Warnings, cautions Always read this section before starting use. Refer to the "General Purpose Valves (Catalog No. CB-03-1SA)" for details on precautions for general purpose valves. Compact Pilot Operated Solenoid Valve for Water FWD Series Design & selection WARNING Working fl uid Do not use with any other fl uid than water. Working environment Do not use the product where the product is exposed to direct-sunlight or may come in contact with water or oil. Can not be used outdoors. CAUTION Designed for Safety About leakage current from other control device When using a programmable logic controller (PLC) to operate the solenoid valve, please ensure that the leakage current from the output of the PLC is within the range specifi ed below. Voltage AC DC Model no. 100V 200V 24V FWD 3mA or less 1.mA or less 1mA or less CR circuit Triac Programmable logic controller side C R Leakage current Solenoid valve CAUTION Installation Install in a manner tension will not be applied to the coil section lead wire. Hold the product body when carrying the product. (Do not hold onto the lead wire.) Installation & adjustment During use & maintenance Piping Dirt or foreign matter in fl uid may prevent the product from functioning correctly. Install a fi lter fi ner than 80 mesh. When the regulator and solenoid valve are directly connected, parts could mutually vibrate causing resonance and chattering. If the piping cross section on the fl uid supply side is restricted, operation may become unstable because of a differential pressure fault when the valve function. Use a pipe that matches the port size on the supply side. CAUTION During use Instantaneous leakage phenomenon When using the 2 port pilot operated solenoid valve, sudden application of pressure (e.g. starting up a pump) could momentarily open a closed valve and cause fl uid to leak. Operation Do not place a back pressure. There is a risk of malfunction. Water-hammer If you experience a water-hammer problem, please consider using CKD "WHL" or "RSV" solenoid valve or a motor valve. Differential pressure Keep the differential pressure 0.02 MPa or above between the primary and secondary sides with the valve open. Differential pressure will become diffi cult to generate between the primary and secondary in the following cases. If a restriction, such as a nozzle is attached to the secondary side. When valves are simultaneously opened in a state where multiple solenoid valves are piped in parallel. Assembling & Disassembling Tightening torque When disassembling or assembling, tighten using the values listed below. Presser plate set thread 0.63 to 0.77N m Body set thread 0.81 to 0.99N m (Port size: 8A, 10A, 1A) 1. to 1.8N m (Port size: 20A, 2A) 2012.9