Magnum Cv Valve Specifications. Magnum IT and Standard Configurations. imagination at work

Similar documents
COMMERCIAL CONTROL VALVES. Magnum Control Valve

255 Valve Specifications

Specifications. Autotrol 255 Valve. Autotrol 255 Series Valve Specifications. Flow Rates (Valve Only) Regeneration Operation

TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL

Performa Valve Specifications. 263 and 268 Configurations. imagination at work

Performa Valve Specifications. 263 and 268 Configurations. imagination at work

255 Valve Specifications

Logix Magnum IT and Cv Valves. Installation and Service Manual

Control Valves, Fittings and Accessories

AUTOTROL 742/762 CONTROL 255 & PERFORMA SERIES VALVES (263, 268, 268 FA)

COMMERCIAL UST ADD WATER BULLETIN; ISSUE 1

Control Valves, Fittings and Accessories

Operation Manual. 742/762 Control 255 and Performa Series Valves (263, 268, 268FA) For Sales & Service questions please contact your dealer:

Operation Manual. 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer:

Operation Manual. 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer:

AQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS

wd-2

Commercial Softeners

740/760 Control 255 and Performa Series Valves (268, 268FA)

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

Owner s Manual HELLENBRAND, INC.

3200ET TIMER. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

TNT SERIES WATER CONDITIONERS

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

AquaMatic Products. Valves, Stagers and Controllers OVERVIEW. GE Water & Process Technologies

Installation and Operations Manual

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

AquaMatic Control Valves, Stagers and Controllers

Model 7000XTR. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

ADVANCE. Backwashing Filters and Tannin Filter. Installation Instructions & Owner s Manual

Water Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS

Water Specialist CI Control Valve Programming and Cover Drawing Manual

Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI

Mark 33 Series. Control Valves Mark 33/39 Electric Motor Control Valves. Electric Motor Control Valves. Features. CRN Registration Number Available

Fleck Top Mount Section 1 Fiberglass Softeners

BNT 85 /185 Valve Operation Manual

A1 Commercial Grade Meters

AquaMatic Series. A100 and A200 Stager Controls

or OWNER S MANUAL MODEL R

BLAKE WATER SOLUTIONS U.S. NORTHEAST REGION DISTRIBUTION CATALOG REV 09/09

Water Specialist WS2H and WS3 Control Valve Manual

AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

Signature Series. Duplex Softener Service Manual

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES

General Operation. To set Time of Day. To set Time of Regeneration / Backwash

5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.

Water Specialist 1 Control Valve Series Model: WS1EI 1.25 Control Valve Series Model: WS1.25EI

G2 Industrial Grade Meters

PRESSURE GAGES AND TEST TAPS

P/N: (Rev. G 1/19/10)

Fleck Epoxy Lined Section 2 Steel Softeners

Installation Instructions & Owner s Manual LINDYSPRING LCR Series II Water Conditioners

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

WS1 & 1.25 Man u al. Introduction. The following general warnings and the specifications in Table 1 must appear in the OEM s System Manual.

INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES

Water Specialist PR Control Valve Programming and Cover Drawing Manual

Water Specialist igen Control Valve Programming and Cover Drawing Manual

NEW CHAPTER 1 CABINET SOFTENERS ARE YOU LOOKING FOR YOUR PERSONAL SOFTENER? 1. CABINET - PERSONALISED

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

OWNER S MANUAL FOR ALL GREENSAND SYSTEMS

IWT 565 Series Valve Operation Manual

ProFloSE. Downflow Brining Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

Features Globe Valve 2-Way & 3-Way Assembly Features:

SIATA VALVES & CONTROLLERS VERSATILITY AND RELIABILITY FOR WATER TREATMENT WATER PURIFICATION VALVES - SIATA

7 ZONE VALVES. Applications

TotalCare Series. Water Conditioners

Superior Water And Air OWNER S MANUAL Model 32-CL770 & 48-CL770

TECHNICAL DATA. Q= C v P S

MASTER. Water Conditioning Corp. Installation and Operation Manual. MCA Combination Series Residential Units

4-Way Mixing Panel Submittal - Page 1 of 6

Superior Water And Air

10 Fully Automatic Backwash Valve 1½ and Half Automatic Backwash Valves 1½ and 2, 3 and 4 Motorized 6-Way-Valves. Side Mount, Screw on top

CHAPTER 1 CABINET SOFTENERS 1. CABINET - PERSONALISED ARE YOU LOOKING FOR A PERSONAL SOFTENER?

Evolve ES Series. Water Softeners. For Models: ES-844 ES-948 ES-1044 ES-1248 ES-1354

MGTE Series 1 1/2 Metered & Time Clock

COMMERCIAL / INDUSTRIAL WATER SOFTENERS

Evolve ES Series. Water Softeners. For Models: ES-844 ES-948 ES-1044 ES-1248 ES-1354

TABLE OF CONTENTS. System Information...3. Pre-Installation Instructions...3. Installation Instructions Control Information...

NUGEN Pure Water Systems Fusion XT. Installation Instructions and Owners Manual

Water Specialist EE Control Valve Programming and Cover Drawing Manual

WATER SOFTENER SERIES DAY TIMER INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

Transfer switch GTEC open or delayed transition

65 Series. Valve Operation Manual

Fleck Fiberglass Section 9 Chloride Dealkalizers

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS

2inch Valve S D S D

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

Condensed Catalog 2006 North America

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

Always on the safe side. Made in Austria/Europe.

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

Zone Valves and Parts (Honeywell)

Technical Manual. Models: Standard Softeners High Efficiency Softeners Combination Softeners S150 S250 S250 OD S350 S550 S650 S650 OD Q850 Q850 OD

Owners Manual Installation Instructions. For Models PTCF PTCF PTCF

Product Data. Features/Benefits. 30HXA HXC Condenserless and Fluid-Cooled Chillers 50/60 Hz. 75 to 265 Tons (264 to 931 kw)

Transcription:

Magnum Cv Valve Specifications Magnum IT and Standard Configurations imagination at work

Specifications Flow Rates (Valve Only) Service @ 15 psi (1.03 ) drop....................... 76 (17.3 m 3 /hr) Backwash @ 25 psi (1.72 ) drop..................... 89 (20.2 m 3 /hr) Service................................................ Cv = 19.5 (Kv = 17) Backwash............................................. Cv = 17.8 (Kv = 19.9) Valve Connections/Dimensions Tank Thread........................................... 4-inch 8 UN Inlet/Outlet........................................... 2-inch: connections NPT or BSPT, Female, CPVC Brine Line............................................. 3/4-inch NPT Drain Line*............................................ 1-1/2-inch: connections for NPT or BSPT, Female, CPVC Riser Tube Diameter.................................. 1-1/2-inch Riser Installation...................................... Above top of tank 5/8-inch (±1/8-inch) Pilot Drain and Auxiliary Hydraulic Output............ 1/4-inch tube fitting *Valve installed drain flow controls available (5 40 ). If higher backwash flow is needed, an external flow control will be required. Design Specifications/Ratings Valve Body............................................ Noryl O-rings................................................ EPDM Injector............................................... 7 sizes available: 14, 16, 18, 21, 24, 30, 36 Working Pressure..................................... 25 psi 100 psi (1.72 6.9 ) Water Temperature................................... 35 100 F (2 38 C), 120 F (49 C) Ambient Options Top Mount or Side Mount Configuration Injector Performance Magnum Cv Injector 1000441 For 14-inch Tanks 3.50 Injector 1000442 For 16-inch Tanks 0.30 0.70 0.30 0.10 0.10 NOTE: Brine draw and rinse rates on empty tank. 2

Injector Performance Magnum Cv (cont d.) 3.50 Injector 1000443 For 18-inch Tanks 5.00 Injector 1000444 For 21-inch Tanks 0.70 4.00 0.30 0.10 Injector 1000445 For 24-inch Tanks Injector 1000446 For 30-inch Tanks 7.00 10.0 1.40 1.20 6.00 5.00 8.0 4.00 6.0 4.0 2.0 0.0 14.0 12.0 10.0 8.0 6.0 4.0 Injector 1000447 For 36-inch Tanks 2.0 0.0 Cartridge-style assembly for easy installation and cleaning of injectors, refill and brine screen features. NOTE: Brine draw and rinse rates on empty tank. 3

Valve Flow Rate Characteristics Magnum Cv C&I Valve (1-1/2 inch inlet) P R E S S U R E D R O P psi 240 35 220 30 200 180 25 160 140 20 120 100 15 80 10 60 40 5 20 0 0 m 3 /h MAGNUM Cv BACKWASH FLOW MAGNUM Cv SERVICE FLOW 0 10 20 30 40 50 60 70 80 90 100 0 2 4 6 8 10 12 14 16 18 20 22 F L O W R A T E Flow Sensor Options Internal Turbine Unit Normal Operating Range.............................. 2-80 (0.45-18.1 m 3 /hr) Peak Operating Range................................ 1-100 (0.22-22.7 m 3 /hr) Normal Accuracy Range.............................. ±3% External Flow Meter 2.0 Inch Normal Operating Range*............................. 2.0-225 ( - 51.0 m 3 /hr) Normal Accuracy Range.............................. ±3% Connections........................................... 2-inch: connections NPT or BSPT, Female, CPVC *Recommended maximum continuous duty flow rate of 2-inch turbine is 70% of maximum flow rate. 4

Controller Options The Magnum is one of the most versatile valves on the market. GE Infrastructure offers two controller series to meet any application need. 900 Series The 962 series controller has a proven, 10-year track record with the Magnum. Fully programmable cycle times Control interlock cable for multiple tank applications Easy cycle indication on front of controller Battery backup and safe 12-volt operation Logix Series The Logix series offers the ultimate in control for the Magnum Cv valve. Simple 3-step programming and installation makes this electronic controller the industry leader. All-electronic control platform 24-hour super-capacitor backup no battery necessary Remote mount kit allows programming module to be installed up to 40 feet away Universal controller works on all Autotrol brand valves Automatic capacity calculations no math or salt tables necessary 12-volt operation 742 Time Clock Simple, economic electronic time clock (chronometric) 7- or 99-day regeneration setting Filter or conditioner setting in one control Fully programmable cycle times Salt setting in 1-pound increments (lbs/cu ft) Operates 255, 263, 268, 278, and Magnum IT with one controller 762 Demand Simple, economic electronic demand (volumetric) Calendar override 99 day 28-day variable reserve Filter or conditioner setting in one controller Automatic capacity calculations Fully programmable cycle times Salt setting in 1-pound increments (lbs/cu ft) Optional no-salt detector Operates 255, 263, 268, 278, and Magnum IT with one controller Electrical Specifications Controller Operating Voltage Input Supply Frequency Motor Input Voltage Electronics Operating Voltage (Logix Series) Control System Power Consumption 12 Volt AC (Requires use of GE Infrastructure supplied transformer) 50 or 60 Hz (Controller configuration dependent) 12 Volt AC 3.5 Volt AC 3 Watts average Transformer Specifications All Controllers All Controllers require the use of a GE Infrastructure supplied transformer. Transformer Output Voltage Transformer Input Options Transformer Plug Options 12 Volt AC 400mA 115 Volt AC 50/60 Hz; 230 Volt AC 50/60 Hz; 100 Volt AC 50/60 Hz Indoor North American Plug Outdoor North American (UL Listed for outdoor use) Japanese Plug Taiwan/Korea Plug Australian Plug United Kingdom Plug Mainland Europe Plug Additional transformers may be available call for more information 5

AUX. DRAIN Control valve manufactured by: North American Sales 5730 N. Glen Park Road Milwaukee, WI 53209-4403 USA (262) 238-4400 Phone (262) 238-4402 Fax For More Information: Call GE Infrastructure Water & Process Technologies; Household Water Group at (262) 238-4400 or (800) 279-9404, or visit www.gewater.com/equipment/valve/index.jsp Magnum Cv Valve Outline Dimensions 1-1/2-inch Magnum Cv 2-inch Magnum IT.493 6.5 cm) 22.796 (57.90 cm) 7.500 (19.05 cm) 6.493 (16.5 cm) 27.224 13.993 4.429 4.500 22.796 (57.90 cm) 4.500 7.500 (19.05 cm) 6.493 (16.5 cm) 3.993 (10.14 cm) 13.481 (34.24 cm) 9.000 (22.86 cm) 3.993 (10.14 cm) 8.680 (22.04 cm) 11.471 (29.13 cm) 8.680 (22.04 cm) 11.471 (29.13 cm) 1.376 4.018 (1 cm) (7.15 cm) 19.500 (49.53 cm) 1.113 (2.82 cm) 7.000 (17.78 15.539 cm) 14.000 (39.47 cm) (35.56 cm) 13.481 (34.24 cm) 9.000 (22.86 cm) 4.018 (1 cm) (7.15 cm) 3.993 (10.14 cm) 1.113 1.113 (2.82 cm) 15.539 15.539 (39.47 cm) 13.481 9.000 4.429 8.680 (22.04 cm) 11.471 (29.13 cm) 8.710 19.500 (49.53 cm) 14.000 (35.56 cm) 7.000 (17.78 cm) 4.018 (1 cm) (7.15 cm) 1.113 (2.82 cm) 15.539 7.000 (39.47 cm) 6.500 9.750 16.250 3.998 2005, General Electric Company. Printed in USA, P/N 1017972 Rev. E