NEED HIGH RESOLUTION LOGO

Similar documents
ALL700RM-230V INSTALLATION INSTRUCTIONS

ALL200RM/ALL200RM-CM

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

ALL W INSTALLATION INSTRUCTIONS

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Installation Instructions: Eco Linear High Bay

Electric Winch. Winch. Designed and Developed for Extreme Application. Months. Warranty. Waterproof Pendant Control. Easy Wiring Connection

HPS Fusion General Purpose Enclosed Transformer

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

HOBART Mobile diesel-driven 60 & 90 kva GPU Cummins QSB4.5 diesel engine ITW GSE Generator TIER 3 / EU STAGE 3A. It s all about connections

NI 9251 with mini XLR

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

Aerial Work Platform Super Series

Steel Outlet Boxes 4 11 /16" Welded

MF-PSMF Series - PTC Resettable Fuses

Model Numbers SAVI-NOTE75, SAVI-NOTE150

Valve Box Assembly for the High-Density Cooling Enclosure ARACVB1

Tanning Bed Transformers

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Go to to register your product and find more information.

Flexiguard Solutions. Unique solutions needs

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

MF4E MF4E

MaxLite LED Linear HighBay Fixtures

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

PV Vault Yielding safety quickly

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Metalux SNLED LENSED LED

HPS Fusion General Purpose Enclosed Transformer

PDU Input Power Cord. Before installation. Specifications

NEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Spec-Tech Industrial Electric

F261 Series Fluid Flow Switches

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Transfer switch OTEC and OTECSE open transition

LT Charging Cart for Laptops

SCXI Power Supply/Float Charger Installation Guide

EG80/EG145 INSTALLATION GUIDE

Operating Instructions and Parts Manual 3-1/2 ton Farm Jack Model FJ-3-1/2A

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

TC26-B Vehicle Sensor

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

Z-TECH FAN Z-TECH FAN WITH Z-CHILL. Features & SPECIFICATIONS

Sky FactoryTM. Classic w/ EcoSlim Electrical Instructions (HLG) Installation Instruction includes:

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

Cable Ladders with Troughs and Partitions

ONTRAC WIRE MESH CABLE TRAY SYSTEM

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Modular Enclosure Solutions RACK IQ - ENTERPRISE & HYPERSCALE DATA CENTER CABINETS

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

InfraStruXure PDU Power Cable

Power Distribution Units

BASKET TRAY SYSTEM WITH PREFAB FITTINGS

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

SPACEMASTER WIRE ROPE HOISTS

Metalux SNLED LENSED LED

ELECTRONIC OVERHEAD TRAVELLING CRANE DIMENSIONS & LOAD DATA

B BASIC HEAT TREATMENT CONSOLE


Installation Instructions: Read these instructions in its entirety before performing any installation work.

SELF CLIMBING HOIST Lighting Suspension

PROJECTOR WITH REMOTE CONTROL

INSTALLATION INSTRUCTIONS

Power and Cooling. Chassis Power System

Arial Regular 25pt. Learn Solar Installation From the Pros!

These documents contain additional information concerning related products from Rockwell Automation.

Product Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems

HW250 REV 8/16 TYPE SOOW. 600 Volt UL/CSA, -40 C to 90 C Black Jacket Flexible Copper Conductors

FLO Home TM G5 Model. Installation guide

Switch & Outlet Boxes Technical Data

ELITE SERIES R-410A Ready - Multi-Position

HPS Spartan Industrial Open Core & Coil Control Transformer

Pipe hanger solutions

Transfer switch OTEC open or delayed transition

Engine 3 Installation

IMPORTANT INFORMATION FOLLOW ALL INSTRUCTIONS

TREE ASSEMBLY INSTRUCTIONS

Connecting External Battery Cabinet(s) to the UNITY/I 9910-UPS

Installation Manual. For. PWC 3000 Boat Lifts

Installation Instructions: Read these instructions in its entirety before performing any installation work.

High Performance Axial Fans

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

Winch & Hoist. Markets and Applications Overview. Safety Reliability Efficiency Expertise Service

Power Distribution Units AP9560 & AP9561

LED IMPORTANT SAFETY INSTRUCTIONS

There s a Difference with Direct! Choose the Direct route. CHOOSE THE DIRECT ROUTE GUARANTEED QUALITY

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Please use the Q & A utility to ask us any questions concerning the material being presented.

SF-0603SP150M SF-0603SP200M SF-0603SP250M

UL Listed TP408. KNOCKOUTS Cat. # Bracket Description Sides Bottom Unit Qty. Wt. Lbs. Per 100 TP408 Drawn 12 1 /2" 5 1 /2" 50 61

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

CUBEFuse. CUBEFuse catalog numbers (amps)

GROOVED COUPLINGS - STANDARD FLEXIBLE Model 101

HOVERTRAX 2.0 HOVERTRAX DLX 2.0 REPLACEMENT BATTERY PACK KIT

Subject: SPF 25A and 30A Product Update. Date: May 1, 2017

Transcription:

NEED HIGH RESOLUTION LOGO 1. Product Name Aladdin Light Lift 2. Manufacturer 61 Shields Road Huntsville, AL 35811 Phone: 256-429-9700 Fax: 256-429-9708 Email: chad@aladdinlightlift.com Web: www.aladdinlightlift.com 3. Product Description Basic Use For more than 25 years, has manufactured self-contained motorized winches engineered to raise and lower high bays, chandeliers and other lighting fixtures. The UL-listed lifts, available throughout the United States, Asia, Canada, Europe, Australia, Central America and South America, are suited for both new and existing construction. Aladdin Light Lifts lower high, hard-to-reach lighting to any height necessary for installation, maintenance or cleaning. In standard installations, the lift is installed directly above the light fixture; offset and remotely-mounted models are available when access above the fixture is limited. Aladdin Light Lifts are controlled by keyswitch or optional Smart- Lift. A controller option lowers as many as 25 Aladdin Light Lifts individually or simultaneously simplifying access and eliminating the need for scaffolding in high bay installations. Capable of supporting as much as 1000 lbs, Aladdin Light Lifts are ideal for plenum space installations and open air warehouses, hangars, office buildings, churches, gymnasiums and auditoriums. Types, Sizes See Table 1. Color, Finish Chassis and commercial model enclosures are laser cut and galvanized. The winch and pulley are zinc plated. The aircraft cable is galvanized steel. 07 Caption Composition and Materials ALL200, ALL200-CM, ALL200RM, ALL200RM-CM, ALL300, ALL300-CM, ALL300RM, ALL300RM-CM Motor: 115 volts, AC/DC, 50/60 hertz, 1/15 hp, 1.3 amp Winch: 4/1 gear ratio, zinc plated Frame: Galvanized Cable: 1/8" galvanized lay cable Electrical: Circuit boards rated min V-0, conformal coated; all components and board are UL listed and regulated Wiring: lead free, RoHS compliant; all wiring and harnesses are UL listed and regulated 4. Technical Data Applicable Standards ASTM International ASTM C897 Standard Specification for Aggregate for Job- Mixed Portland Cement-Based Plasters ALL700, ALL700-CM, ALL700RM, ALL700RM-CM, ALL1000, ALL1000-CM, ALL1000RM, ALL1000RM-CM Motor: 115 volt, AC, 60 hertz, 1/9 hp, 1.4 amp Winch: 15.4/1 gear ratio, zinc plated Frame: Galvanized Cable: 7/32" galvanized lay cable Electrical: Circuit boards rated min V-0, conformal coated; all components and board are UL listed and regulated Wiring: Lead free, ROHS compliant; all wiring and harnesses are UL listed 1

Table 1 Types and Sizes Model Application Lift Capacity Voltage Light Capacity Winch Cable Controller Controller Wire Dimensions Weight ALL200 Residential 200 lbs Option: 14" W x 19" L x 9" H 47 lbs ALL200-CM 200 lbs Option: ; ; 14" W x 20.5" L x 9" H 57 lbs ALL200-RM Residential 200 lbs Option: 14" W x 18" L x 9" H 57 lbs ALL200RM-CM 200 lbs t Option:, 14" W x 20.5" L x 9" H 67 lbs ALL300 Residential 300 lbs Option: 14" W x 19" L x 9" H 47 lbs ALL300-CM 300 lbs Option: ; 14" W x 20.5" L x 9" H 57 lbs ALL300-RM Residential 300 lbs Option: 14" W x 18" L x 9" H 57 lbs ALL300RM-CM 300 lbs Option:, 14" W x 20.5" L x 9" H 67 lbs. ALL700 Residential 700 lbs Option: 18" W x 27.5" L x 9" H 96 lbs ALL700-CM 700 lbs Option: Std: ; Option: 18" W x 29.5" L x 9" H 110 lbs ALL700RM Residential 700 lbs Option: 18" W x 27.5" L x 10" H 111 lbs ALL700RM-CM 700 lbs Option: Std: Option: 18" W x 29.5" L x 10" H 125 lbs ALL1000 Residential 1000 lbs Option: 18" W x 27.5" L x 9" H 98 lbs ALL1000-CM 1000 lbs Option: Std: ; Option: 18" W x 29.5" L x 9" H 112 lbs ALL1000-RM Residential 1000 lbs Option: Option: 100' 18" W x 27.5" L x 10" H 113 lbs ALL1000RM-CM 1000 lbs Option: Std: Option: Multi- Lift Option: 100' 18" W x 29.5" L x 10" H 127 lbs 2

Options Controller A touch panel unit that can automatically stop the lift at a desired height and then automatically stop at the ceiling when being raised Key-Switch Controller A controller that operates the light lift with the turning and holding of a key Controller A wall mounted, LCD Control Panel designed to operate up to 25 daisy-chained light lifts within a single room Voltage and residential models are light and motor packages. models are available with 208V, 240V or 277V Sloped ceiling adapter Torque reel mount and residential applications Configurations Aladdin Light Lifts are available in standard mount and remote mount, residential and commercial configurations. See Table 1. Benefits Allows safe and efficient light fixture service at floor level without the need for ladders or scaffolding Raises and lowers lighting with easy-to-use, single-switch or touch pad operations Reduces liability and cost of high bay maintenance Supports fixtures up to 1000 lbs Suited for residential and commercial installations UL and ULC listed Restrictions Mount lifts in a dry, accessible indoor location Do not install in an indoor pool area Install only with a single point hanging light fixture Do not transport humans or objects other than light fixtures Do not modify or install lifts with horizontal cable directional changes; all pulleys should be mounted in the same vertical plain Separate light and motor circuits 4. Technical Data Applicable Standards Canadian Standards Association (CSA) CSA-C22.2, No. 33 Construction and Test of Electric Cranes and Hoists Conformité Européenne/European Conformity (CE) European Committee for Standardization, European Committee for Electrotechnical Standardization Underwriters Laboratories (UL) UL 1340 Standard for Hoists CSA-C22.2, No. 33 Safety Code for Material Hoists Approvals, Certifications All models are UL listed for the U.S. and Canada 240 volt models are UL, ULC listed and additionally comply with CE standards Technical and Mechanical Properties Winch ALL200, ALL200-CM, ALL200RM, ALL200RM-CM, ALL300, ALL300-CM, ALL300RM, ALL300RM-CM winch: 4:1 gear ratio ALL700, ALL700-CM, ALL700RM, ALL700RM-CM, ALL1000, ALL1000-CM, ALL1000RM, ALL1000RM-CM winch: 15.4:1 gear ratio Electrical Conductivity Performance Wiring is lead-free and RoHS compliant All wiring and harnesses UL listed and regulated All units are hi-pot tested and built within local electrical code: UL listed for the U.S. and Canada Circuit boards rated min V-0 and conformal coated Components and board are UL listed and regulated 3

Standard mount Remote mount Flamespread/Smoke Performance Electrical contact plates and circuit board are 94VO; plastic enclosure on residential models are HB per UL Weight-bearing Information All models are 4:1 static weight bearing Motor Voltage, HP: ALL200, ALL200-CM, ALL200RM, ALL200RM-CM, ALL300, ALL300-CM, ALL300RM, ALL300RM-CM: 115 volt, AC/DC, 50/60 hertz, 1/15 hp, 1.3 amp ALL700, ALL700-CM, ALL700RM, ALL700RM-CM, ALL1000, ALL1000-CM, ALL1000RM, ALL1000RM-CM: 115 volt, AC, 60 hertz, 1/9 hp, 1.4 amp All models are lead free, ROHS compliant; all wiring and harnesses UL are listed and regulated 5. Installation Preparatory Work Deliver product in manufacturer's original, unopened, undamaged containers with identification labels intact. Store protected from exposure to harmful environmental conditions, frost-free and at temperature and humidity levels recommended by the manufacturer. Line voltage should be supplied for both light circuit and motor circuit. Also, location of fixture should be decided. Precautions Aladdin Light Lifts must be installed by licensed electricians and the installation instructions provided with each lift should be methodically followed. Methods For installation detail, refer to the manufacturer's instructions for the selected model or visit www.aladdinlightlift.com. Building Codes Ensure installation complies with the requirements of all applicable local, state and federal code jurisdictions. 6. Availability and Cost Aladdin Light Lifts are available worldwide. The product typically ships within 1-2 days and is in the hands of the end user within a week. Contact Aladdin Light Lift for availability and cost information within a specific region. 4

7. Warranty warrants its light lift unit for one year from the date of purchase. The warranty includes all parts, provided the unit is installed properly by a licensed electrician. Labor charges will be the responsibility of the purchaser. 8. Maintenance Aladdin Light Lifts require only occasional visual cable inspection by the facility manager or building/home owner. Aladdin Light Lifts should be serviced by licensed electricians. Technical support is available from the manufacturer, Monday- Friday, 8-4 CST. For questions or assistance, visit the Aladdin Light Lift website, www.aladdinlightlift.com or call the toll-free tech support number: 877-287-4601. 10. Filing Systems CMD Group CE UL (U.S. and Canada) Additional product information is available from the manufacturer upon request 9. Technical Services Technical assistance, including detailed information, product literature, test results, project lists and assistance in preparing project specifications is available from 5